• Title/Summary/Keyword: maximum length

Search Result 3,059, Processing Time 0.032 seconds

Asymptotic Distributions of Maximum Queue Lengths for M/G/1 and GI/M/i Systems

  • Park, You-Sung
    • Journal of the Korean Statistical Society
    • /
    • v.24 no.1
    • /
    • pp.19-29
    • /
    • 1995
  • In this paper, we investigate the asymptotic distributions of maximum queue length for M/G/1 and GI/M/1 systems which are positive recurrent. It is well knwon that for any positive recurrent queueing systems, the distributions of their maxima linearly normalized do not have non-degenerate limits. We show, however, that by concerning an array of queueing processes limiting behaviors of these maximum queue lengths can be established under certain conditions.

  • PDF

The Influence of Step Length at Different Walking Speed on the Moment of the Lower Limb Joint (보행속도에 따른 보폭변화가 하지관절 모멘트에 미치는 영향)

  • Kim, Ro-Bin;Jin, Young-Wan;Moon, Gon-Sung
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.93-102
    • /
    • 2005
  • The purpose of this study was to examine the effect of step length on the joint moment. The subjects were 4 undergraduate and graduate students in their 20s with normal legs. The subjects were individually tested by the running timer at the walking speed of 0.67m/s, 134m/s, and 2.46m/s. The step length was regulated to -10% of normal, normal and +10% of normal step length using foot print. The walking performances of each subjects were filmed using a high speed video camera. The raw data were analyzed by LabVIEW Graphical Program and these data were analyzed by ANOVAs and Scheffe. The results of this study were as follows: The maximum dorsiflexion moment of the ankle joint increased as the step length increased only at the fast walking speed. Although there wasn't significant difference shown in the plantar flexion moment, regular pattern in the plantar flexion moment which increased as the step length increased was found. The first maximum extension moment of the knee joint increased only at the normal walking speed, but there appeared no significant difference in the maximum flexion and second extension moment. The maximum extension moment of the hip joint increased at the normal and fast walking speed. Although there wasn't significant difference, regular pattern in flexion moment which increased as the step length increased was found.

In Vivo Three-Dimensional Evaluation of the Functional Length of Glenohumeral Ligaments

  • Yang, Chen;Goto, Akira;Sahara, Wataru;Koishi, Hayato;Yoshikawa, Hideki;Sugamoto, Kazuomi
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2009.03a
    • /
    • pp.43-43
    • /
    • 2009
  • Glenohumeral ligaments play an important role in stabilizing the shoulder. However, it is impossible to know how they function in vivo during shoulder motion. To help elucidate this stabilizing role, we conducted in vivo three-dimensional kinematics of the normal shoulder joint using a markerless bone-registration technique. Magnetic resonance images of 14 shoulder joints of 7 healthy volunteers were acquired for 7 isometric abduction positions between $0^{\circ}$ and $180^{\circ}$. We then calculated three-dimensional shortest paths between the origin and insertion of each ligament based on anatomical study in each abduction position. At $0^{\circ}$ of abduction, the posterior band of the coracohumeral ligament displayed the maximum length. At $30^{\circ}$ of abduction, the superior glenohumeral ligament displayed the maximum length. At $60^{\circ}$ of abduction, the anterior band of the coracohumeral ligament and the middle glenohumeral ligament displayed the maximum length. At $120^{\circ}$ of abduction, the anterior band of the inferior glenohumeral ligament displayed the maximum length. We think that the maximum length of these results is an important influence on the function of the soft tissue stabilizer.

  • PDF

A COMPARATIVE STUDY ON THE SEVERAL FACIAL MEASUREMENT METHOD FOR VERTICAL DIMENSION (수직고경 설정을 위한 안면 계측방법에 관한 비교 연구)

  • Park, Jong-Hwan;Oh, Sang-Chun;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.75-84
    • /
    • 1995
  • This study was designed as a reference of vertical dimension in prosthetic treatment. The author analyzed six facial measurements, namely, (1) the height of lower face at maximum intercuspal position, (2) the height of lower face at resting position, (3) midface, (4) external ear and lateral wall of orbit, (5) interpupillary distance, (6) distance between pupil and mouth in the 100 Won-kwang Univ. Dental collage students(50 : male, 50 : female), who have normal occlusion, no posterior prosthesis, no experience of orthodontic treatment, and no deformity of facial soft tissue and no temporomandibular dysfunction. The results of this study were as follows : 1. The length of midface was shortest and the inter-pupillary distance was longest in both male and female. 2. The length difference with the length of midface and lower face at maximum intercuspal position was 5.64mm in male and 2.23mm in female, so the lower face was longer, 3. The facial measuring component, similar to lower face at maximum intercuspation, was the length of between medial wall of external ear and lateral wall of orbit. It's difference was 1.3mm in male, 1.77mm in female, and the lower face was shorter. 4. The difference of lower facial length in resting position and maximum intercuspation was 2.48mm in male, 2.24mm in female, the length of resting position was therefore longer. 5. The most clost correlation with the height of maximum intercuspal positioning lower face was resting lower face in both groups.

  • PDF

Influence of moisture content on main mechanical properties of expansive soil and deformation of non-equal-length double-row piles: A case study

  • Wei, Meng;Liao, Fengfan;Zhou, Kerui;Yan, Shichun;Liu, Jianguo;Wang, Peng
    • Geomechanics and Engineering
    • /
    • v.30 no.2
    • /
    • pp.139-151
    • /
    • 2022
  • The mechanical properties of expansive soil are very unstable, highly sensitive to water, and thus easy to cause major engineering accidents. In this paper, the expansive soil foundation pit project of the East Huada Square in the eastern suburb of Chengdu was studied, the moisture content of the expansive soil was considered as an important factor that affecting the mechanics properties of expansive soil and the stability of the non-equal-length double-row piles in the foundation pit support. Three groups of direct shear tests were carried out and the quantitative relationships between the moisture content and shear strength τ, cohesion c, internal friction angle φ were obtained. The effect of cohesion and internal friction angle on the maximum displacement and the maximum bending moment of piles were analyzed by the finite element software MIDAS/GTS (Geotechnical and Tunnel Analysis System). Results show that the higher the moisture content, the smaller the matrix suction, and the smaller the shear strength; the cohesion and the internal friction angle are exponentially related to the moisture content, and both are negatively correlated. The maximum displacement and the maximum bending moment of the non-equal length double-row piles decrease with the increase of the cohesion and the internal friction angle. When the cohesion is greater than 33 kPa or the internal friction angle is greater than 25.5°, the maximum displacement and maximum bending moment of the piles are relatively small, however, once crossing the points (the corresponding moisture content value is 24.4%), the maximum displacement and the maximum bending moment will increase significantly. Therefore, in order to ensure the stability and safety of the foundation pit support structure of the East Huada Square, the moisture content of the expansive soil should not exceed 24.4%.

Effects of Eccentric Exercise on Torque-Angle Relationship of Human Tibialis anterior In-vivo (신장성 수축 운동에 의한 인체 하지 전경골근의 족배굴곡 토크-발목 각도 특성 변화)

  • Lee, Hae-Dong;Kim, Seung-Jae;Yasuo, Kawakami
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1575-1579
    • /
    • 2008
  • The purpose of this study was to investigate how maximum-effort eccentric exercise over different contraction ranges affects the characteristics of torque-angle relationship of human ankle plantarflexor in-vivo. Subjects were randomly assigned in two groups. One group (n=6) performed 120 maximum-effort eccentric ankle dorsiflexion contractions at short muscle length (ankle range of motion from -5 to 15 deg) and the other group (n=6) at long (ankle range of motion from 10 to 30 deg) muscle length. Eccentric exercise decreased the maximum isometric ankle plantarflexion torque ${\sim}40%$. It was found that the optimum ankle joint angle changed from 7.5 deg to 11.1 deg and 10.1 deg, shifted toward the longer muscle length, regardless of the exercise range. The results of this study suggest that eccentric exercise alters the characteristics of torqueangle relationship of the muscle but there is no differential effect of the eccentric contraction range.

  • PDF

A Study on the Pattern-making for Korean Glove - Focusing on Pattern-making for Glove - (한국인을 위한 장갑 패턴 고찰 (2) - 장갑 원형 설계를 중심으로 -)

  • Ryu, Kyoung-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.17 no.6
    • /
    • pp.981-991
    • /
    • 2009
  • The purpose of this study was to develop the pattern-making for Korean glove. To develop the pattern-making for glove this study comprehensive list of candidate hand data was reviewed and the manufacturers(career over th 15 years) were interviewed on the method of glove. The results of regression analysis(hand data) were as follows (unit: cm): wrist thumb tip length = middle finger length + 3.22, hand bread = 1.25 $\times$ middle finger length + 2.18, middle finger breadth at dist = 0.23 $\times$ index finger circumference + 0.4, maximum hand circumference = 3.15 $\times$ index finger circumference + 4.13, middle finger circumference = 0.91 $\times$ index finger circumference + 0.47, maximum hand thickness = 0.69 $\times$ index finger circumference -0.02. Hand measurements for glove pattern-making were developed: There were palmar hand length, hand circumference, index finger circumference and middle finger length.

  • PDF

Kinematic GPS Positioning with Baseline Length Constraint Using the Maximum Possibility Estimation Method

  • Wang, Xinzhou;Xu, Chengquan
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.247-250
    • /
    • 2006
  • Based on the possibility theory and the fuzzy set, the Maximum Possibility Estimation method and its applications in kinematic GPS positioning are presented in this paper. Firstly, the principle and the optimal criterion of the Maximum Possibility Estimation method are explained. Secondly, the kinematic GPS positioning model of single epoch single frequency with baseline length constraint is developed. Then, the authors introduce the artificial immune algorithm and use this algorithm to search the global optimum of the Maximum Possibility Estimation model. The results of some examples show that the method is efficient for kinematic GPS positioning.

  • PDF

A Study on Floating Collar of Dragged Gears (인망그물의 부양깃판에 관하여)

  • 장지원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 1986
  • In order to improve the net-mouth height of dragged gears, the authors devised models of floatingcollars of nylon cloth instead of floats and experimented with 4 types-A type (length 65em, breadth 3em), B type (length 65em, breadth 4em), C type (length 65em, breadth 5em) and D type (length 65 em, breadth 6em) attached respectively to the front edge of square of a model net after preliminary experimentation. These various types of floating collars were experimented in a circulating water channel to evaluate the characteristics of net-mouth height and hydrodynamic resistance and the effect of the length of bridles were also examined. The results obtained were as follows: 1. In case of attaching floats, the model net-mouth height reduced from 80 em to 20 em when current velocity was increased from 0.25m/see to 1m/sec. 2. In case of attaching floating collars, the model net-mouth heights were maintained 70 em, 71 em, 80 em, 78 em in maximum and 55 em, 63 em, 69 em, 73 em in minimum respectively even the current volocity was increased from 0.25 m/see to 1 m/see. 3. The model net-mouth height was reduced to 10 em maximum according to the current velocity and types of floating collars when the bridles were shortened 3~4 mm in length. 4. Hydrodynamic resistance of D type only was increased to 700 g in maximum and those of A, B, C type were reduced to 460 g in maximum at current velocity beyond 0.5 m/ see when bridles were shortened 3-4 mm in length. 5. But the model net-mouth heights became higher in accordance with breadth of floating coliars, B type was the best for this model net in case that hydrodynamic resistance was taken into account.

  • PDF

Changes in Body Surface Lines Caused By Lower Limb Movements in Designing Slacks (II) (슬랙스 설계를 위한 하지동작에 따른 체표선 변화 2)

  • Cho Sung-Hee
    • Korean Journal of Human Ecology
    • /
    • v.7 no.3
    • /
    • pp.35-48
    • /
    • 2004
  • In this study, by determining lower limb movements which cause significant changes in body surface lines, body parts with the greatest maximum expansion and contraction rate respectively were illustrated in descending order. Using unmarried female university students aged 18 - 24 as subjects, a total of 32 body surface categories (15 body surface lines and 17 body surface segment lines) were measured in one static and 9 movement poses. In particular, expansion and contraction levels and rates were measured and used in the analysis. The analysis first involved the calculation of the average measurement per body part in body surface line in static pose as well as of the average expansion and contraction levels and rates in 9 lower limb movements. Two-way MANOVA and multiple comparison analysis (Tukey) were conducted on movements and individual somatotypes regarding measurement per body part and expansion and contraction rates. Movements which cause measurements of body surface lines differed significantly in body surface line in static pose versus in movement were then identified. Among average expansion and contraction rates in such movements, maximum average expansion and contraction levels, maximum average expansion and contraction rate, and classes of expansion and contraction rate were determined per body part. The results of this study are as follows. First, 5 lower limb movements; F2, F5, F6, F7, F8, which caused significant changes in body surface lines were determined and illustrated in table 4. Second, the levels, rates, and classes of expansion and contraction rate per body part are illustrated in Tables 5 and 6. Body parts with the greatest maximum expansion rate were, in descending order: upper segment of center back leg line, upper segment of inner leg line, middle segment of center front leg line, posterior crotch length, anterior knee girth, anterior thigh girth, center back leg line, girth at crotch height, anterior midway thigh girth, hip girth, anterior crotch length, knee girth, waist girth, inner leg line, thigh girth, and crotch length. Those with the greatest maximum contraction rate were, in descending order: anterior crotch length, upper segment of center front leg line, lower segment of center back leg line, center front leg line, and posterior thigh girth. The maximum expansion rates and maximum contraction rates, which ranged from 2.05 to $35.95\%$ and from -0.20 to $-30.16\%$ respectively, were classified per body part into 4 ABCD classes. The body part with maximum expansion was the upper segment of the center back leg line at vertical body surface line, expanding by $35.95\%$ or 16.03cm in F5 flexion movement. In contrast, the body part with maximum contraction was the anterior crotch length at vertical body surface line, contracting by $-30.16\%$ or -10.54cm in F5 flexion movement. Both, however, were the body parts to expand or contract the most among all horizontal and vertical body surface lines.

  • PDF