• Title/Summary/Keyword: maximum ductility

Search Result 334, Processing Time 0.031 seconds

Comparison between ACI 318-05 and Eurocode 2 (EC2-94) in flexural concrete design

  • Hawileh, Rami A.;Malhas, Faris A.;Rahman, Adeeb
    • Structural Engineering and Mechanics
    • /
    • v.32 no.6
    • /
    • pp.705-724
    • /
    • 2009
  • The two major widely used building design code documents of reinforced concrete structures are the ACI 318-05 and Eurocode for the Design of Concrete Structures EC2. Therefore, a thorough comparative analysis of the provisions of these codes is required to confirm their validity and identify discrepancies in either code. In this context, provisions of flexural computations would be particularly attractive for detailed comparison. The provisions of safety concepts, design assumptions, cross-sectional moment capacity, ductility, minimum and maximum reinforcement ratios, and load safety factors of both the ACI 318-05 and EC2 is conducted with parametric analysis. In order to conduct the comparison successfully, the parameters and procedures of EC2 were reformatted and defined in terms of those of ACI 318-05. This paper concluded that although the adopted rationale and methodology of computing the design strength is significantly different between the two codes, the overall EC2 flexural provisions are slightly more conservative with a little of practical difference than those of ACI 318-05. In addition, for the limit of maximum reinforcement ratio, EC2 assures higher sectional ductility than ACI 318-05. Overall, EC2 provisions provide a higher safety factor than those of ACI 318-05 for low values of Live/Dead load ratios. As the ratio increases the difference between the two codes decreases and becomes almost negligible for ratios higher than 4.

Experimental and analytical assessment of SRF and aramid composites in retrofitting RC columns

  • Dang, Hoang V.;Shin, Myoungsu;Han, Sang Whan;Lee, Kihak
    • Earthquakes and Structures
    • /
    • v.7 no.5
    • /
    • pp.797-815
    • /
    • 2014
  • This research aimed to investigate retrofitting methods for damaged RC columns with SRF (Super Reinforced with Flexibility) and aramid composites and their impacts on the seismic responses. In the first stage, two original (undamaged) column specimens, designed to have a flexural- or shear-controlled failure mechanism, were tested under quasi-static lateral cyclic and constant axial loads to failure. Afterwards, the damaged column specimens were retrofitted, utilizing SRF composites and aramid rods for the flexural-controlled specimen and only SRF composites for the shear-controlled specimen. In the second stage, the retrofitted column specimens were tested again under the same conditions as the first stage. The hysteretic responses such as strength, ductility and energy dissipation were discussed and compared to clarify the specific effects of each retrofitting material on the seismic performances. Generally, SRF composites contributed greatly to the ductility of the specimens, especially for the shear-controlled specimen before retrofitting, in which twice the deformation capacity was obtained in the retrofitted specimen. The shear-controlled specimen also experienced a flexural failure mechanism after retrofitting. In addition, aramid rods moderately fortified the specimen in terms of the maximum shear strength. The maximum strength of the aramid-retrofitted specimen was 12% higher than the specimen without aramid rods. In addition, an analytical modeling of the undamaged specimens was conducted using Response-2000 and Zeus Nonlinear in order to further validate the experimental results.

Improvement and Evaluation for Seismic Resistant Capacity of Reinforced Concrete Shear wall with Connection Types and Diagonal Reinforcement (철근콘크리트 전단벽의 접합방식과 대각보강에 따른 내진성능 평가 및 개선)

  • Shin, Jong-Hack;Ha, Gee-Joo;An, Joon-Suk;Ju, Jung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.3 no.3
    • /
    • pp.139-147
    • /
    • 1999
  • Six reinforced concrete shear wall, constructured with fully rigid, slit, and infilled types, were tested under both vertical and cyclic loadings. Experimental programs were carried out to evaluate the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility, under load reversals. All the specimens were modeled in one-third scale size. Based on the test results, the following conclusions can be made. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crushing due to slippage prevention of boundary region and reduction of diagonal tension rathar than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by l.14 times and l.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF

Comparison of Steel Fiber Reinforced Column Capacity Using Ordinary and High Strength Concrete (콘크리트 강도에 따른 강섬유 보강기둥의 성능비교)

  • 장극관;이현호;문상덕
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.23-28
    • /
    • 2001
  • Since the steel fiber used in concrete to improve shear and ductility capacity, a number of laboratory tests have been studied to define shear strengthening effect according steel fiber contents in concrete. This study investigates shear strengthening effect of steel fiber in RC columns according to compression strength of concrete. From the structural performance test, following conclusions can be made; the maximum enhancement of shear strengthening effect can be achieved at about 1.0 %~l.5 % of steel fiber contents in comparison with shear capacity ratio, and ductility capacity slightly improved as steel fiber contents increased.

  • PDF

Strengthening Effects of Slabs by Aramid Fiber Sheet (아라미드섬유 쉬트에 의한 슬래브의 보강효과)

  • Yeon, Kyu-Seok;Kang, Young-Sug;Kim, Hyung-Woo;Lee, Youn-Su;Kim, Nam-Gil
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.105-113
    • /
    • 1999
  • This study was conducted to evaluate the structural behaviors of Aramid fiber sheet reinforced slabs. Seven concrete slabs with $45{\times}8.5{\times}200cm$ were made for this experiment one slab with out being reinforced completely loaded until failure and the maximum load was obtained from this test. 70% of the maximum load was applied to 3 Aramid fiber sheet reinforced slabs after cracking and to the rest of 3 Aramid fiber sheet reinforced slabs without loading and cracking. Test results shows that maximum loading flexural rigidity and ductility for the Araimid fiber sheet reinforced slabs after initial cracking are similar as those for the Armied fiber sheet reinforced slabs without loading and cracking.

Novel steel bracket and haunch hybrid system for post-earthquake retrofit of damaged exterior beam-column sub-assemblages

  • Kanchanadevi, A.;Ramanjaneyulu, K.
    • Structural Engineering and Mechanics
    • /
    • v.73 no.3
    • /
    • pp.239-257
    • /
    • 2020
  • In the present study, an innovative steel bracket and haunch hybrid scheme is devised, for retrofitting of earthquake damaged deficient beam-column sub-assemblages. Formulations are presented for evaluating haunch force factor under combined load case of lateral and gravity loads for the design of double haunch retrofit. The strength hierarchies of control and retrofitted beam-column sub-assemblages are established to showcase the efficacy of the retrofit in reversing the undesirable strength hierarchy. Further, the efficacy of the proposed retrofit scheme is demonstrated through experimental investigations carried out on gravity load designed (GLD), non-ductile and ductile detailed beam-column sub-assemblages which were damaged under reverse cyclic loading. The maximum load carried by repaired and retrofitted GLD specimen in positive and negative cycle is 12% and 28% respectively higher than that of the control GLD specimen. Further, the retrofitted GLD specimen sustained load up to drift ratio of 5.88% compared with 2.94% drift sustained by control GLD specimen. Repaired and retrofitted non-ductile specimen, could attain the displacement ductility of three during positive cycle of loading and showed improved ductility well above the expected displacement ductility of three during negative cycle. The hybrid haunch retrofit restored the load carrying capacity of damaged ductile specimen to the original level of control specimen and improved the ductility closer to the expected displacement ductility of five. The total cumulative energy dissipated by repaired and retrofitted GLD, non-ductile and ductile specimens are respectively 6.5 times, 2.31 times, 1.21 times that of the corresponding undamaged control specimens. Further, the damage indices of the repaired and retrofitted specimens are found to be lower than that of the corresponding control specimens. The novel and innovative steel bracket and haunch hybrid retrofit scheme proposed in the present study demonstrated its effectiveness by attaining the required displacement ductility and load carrying capacity and would be an excellent candidate for post-earthquake retrofit of damaged existing RC structures designed according to different design evolutions.

Analytical Study on Ductility Index of Reinforced Concrete Flexural Members (철근 콘크리트 휨부재의 연성지수에 관한 해석적 연구)

  • Lee, Jae Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.391-402
    • /
    • 1994
  • One of the most important design concept for reinforced concrete structures is to achieve a ductile failure mode, and also moment redistribution for economic design is possible in case that adequate ductility is provided. Flexural ductility index is, therefore, used as a reference for possibility of moment redistribution as well as for prediction of flexural behavior of designed R.C. structures. Ductility index equations, however, provide approximate values due to the linear concrete compressive stress assumption at the tension steel yielding state. Theoretically more exact ductility index is calculated by a numerical analysis with the realistic stress-strain curves for concrete and steel to be compared with the result from tire ductility index equations. Variation of ductility index for the selected variables and the reasonable maximum tension steel ratio for doubly reinforced section are investigated. A moment-curvature curve model is also proposed for future research on moment redistribution.

  • PDF

Design for moment redistribution in FRP plated RC beams

  • Oehlers, Deric John;Hasketta, Matthew;Mohamed Ali, M.S.
    • Structural Engineering and Mechanics
    • /
    • v.38 no.6
    • /
    • pp.697-714
    • /
    • 2011
  • Assessing the ductility of reinforced concrete sections and members has been a complex and intractable problem for many years. Given the complexity in estimating ductility, members are often designed specifically for strength whilst ductility is provided implicitly through the use of ductile steel reinforcing bars and by ensuring that concrete crushing provides the ultimate limit state. As such, the empirical hinge length and neutral axis depth approaches have been sufficient to estimate ductility and moment redistribution within the bounds of the test regimes from which they were derived. However, being empirical, these methods do not have a sound structural mechanics background and consequently have severe limitations when brittle materials are used and when concrete crushing may not occur. Structural mechanics based approaches to estimating rotational capacities and rotation requirements for given amounts of moment redistribution have shown that FRP plated reinforced concrete (RC) sections can have significant moment redistribution capacities. In this paper, the concept of moment redistribution in beams is explained and it is shown specifically how an existing RC member can be retrofitted with FRP plates for both strength and ductility requirements. Furthermore, it is also shown how ductility through moment redistribution can be used to maximise the increase in strength of a member. The concept of primary and secondary hinges is also introduced and it is shown how the response of the non-hinge region influences the redistribution capacity of the primary hinges, and that for maximum moment redistribution to occur the non-hinge region needs to remain elastic.

Evaluation of Seismic Performance for Reinforced Concrete Piers Using Capacity Spectrum Method (역량스펙트럼 방법을 이용한 철근 콘크리트 교각의 내진성능 평가)

  • Song, Jong-Keol;Chang, Dong-Huy;Chung, Yeong-Hwa
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.185-194
    • /
    • 2004
  • To evaluate seismic performance of reinforced concrete piers two procedures for capacity spectrum method are presented. The capacity spectrum procedures include the reduction factor-ductility-period($R_{\mu}-{\mu}-T$)relationship in order to construct the inelastic demand spectra from the elastic demand spectra. Application of the procedures are illustrated by example analysis. Maximum displacements estimated by the procedures are compared to those by inelastic time history analysis for several artificial earthquakes. The results show that the maximum displacements estimated by the procedures are, on overall, smaller than those by the inelastic time history analysis.

  • PDF

Evaluation and Improvement of Structural Performance of Reinforced Shear Walls Under Load Reversals (철근콘크리트 내진벽의 구조성능 평가 및 개선)

  • 신종학;하기주;안준석;주정준
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.683-688
    • /
    • 1999
  • The purpose of this study is to develop and evaluate the structural performance of various shear walls, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. For the diagonal reinforced slit and infilled shear wall specimens, it was found that the failure mode shows very effective crack control and crashing due to slippage prevention of boundary region and reduction of diagonal tension rather than the brittle shear and diagonal tension failure. The ductility of specimens designed by the diagonal reinforcement for the slit and infilled shear wall was increased 1.72~1.81 times in comparison with the fully rigid shear wall frame. Maximum horizontal load-carrying capacity of specimens designed by the diagonal reinforcement ratio the slit and infilled shear wall was increased respectively by 1.14 times and 1.49 times in comparison with the standard fully rigid shear wall frame.

  • PDF