• Title/Summary/Keyword: maximum blood pressure

Search Result 141, Processing Time 0.026 seconds

On Employing Nonparametric Bootstrap Technique in Oscillometric Blood Pressure Measurement for Confidence Interval Estimation

  • Lee, Yong-Kook;Lee, Im-Bong;Chang, Joon-Hyuk;Lee, Soo-Jeong
    • Journal of Korea Multimedia Society
    • /
    • v.17 no.2
    • /
    • pp.200-207
    • /
    • 2014
  • Blood pressure (BP) is an important vital signal for determining the health of an individual subject. Although estimation of mean arterial blood pressure is possible using oscillometric blood pressure techniques, there are no established techniques in the literature for obtaining confidence interval (CI) for systolic blood pressure (SBP) and diastolic blood pressure (DBP) estimates obtained from such BP measurements. This paper proposes a nonparametric bootstrap technique to obtain CI with a small number of the BP measurements. The proposed algorithm uses pseudo measurements employing nonparametric bootstrap technique to derive the pseudo maximum amplitudes (PMA) and the pseudo envelopes (PE). The SBP and DBP are then derived using the new relationships between PMA and PE and the CIs for such estimates. Application of the proposed method on an experimental dataset of 85 patients with five sets of measurements for each patient has yielded a smaller Cl than the conventional student t-method.

The Blood Pressure Response during Graded Exercise Test in Obese Adults

  • Shin, Kyung-A
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.215-222
    • /
    • 2017
  • Obesity has been directly associated with the development of hypertension and cardiovascular disease. The purpose of this study was to investigate the blood pressure response during graded exercise test in obese adults. 189 subjects (age: $47.96{\pm}10.23$) were assigned to two groups: non-obese group (N=105, BMI: $22.05{\pm}1.57$, waist circumference: $76.90{\pm}6.17$) and obese group (N=84, BMI: $26.96{\pm}2.51$, waist circumference: $88.29{\pm}6.41$). The subjects underwent health screening and exercise treadmill test from January 2012 to December 2014. Graded exercise test was performed according to the Bruce protocol. Exercise duration (P=0.046) and METs (P=0.015) were significantly lower in obese group than non-obese group. There was no difference in the rate of change in blood pressure response between obese group and non-obese group during exercise, and the recovery rate of systolic blood pressure was delayed in the obese group compared to non-obese group in the first recovery period (P=0.020). The significant factors of increasing rate of change in maximum systolic blood pressure was waist (P=0.046) and hip circumference (P=0.008). In conclusion, these results demonstrate that, for hypertension prevention in obese adults, waist and hip circumference levels should be managed within normal range.

Change of blood pressure end vasorelaxation on EAE-induced lewis rat

  • Bong su Kang;Park, Young shim;In hoi Huh
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.04a
    • /
    • pp.194-194
    • /
    • 1996
  • Pathogenesis of experimental allergic encephalomyelitis was involved with infection, inflammatory reaction, immune reaction etc. We studied on relation of blood vessel system and EAE. So, we measured blood pressure, heart rate and relaxation of isolated blood vessel in control and EAE-induced lewis rats. Blood pressure was decreased before EAE clinical sign (0-20day), but was increased from 23day. In isolated blood vessel, acetylcholine-treated relaxation was different on control, maximum EAE stage, recovery stage. Acetylcholine-treated relaxation was reduced 30% in recovery stage. but, sodium nitroprusside had similar relaxation reaction.

  • PDF

The Effects of Regular Pilates Exercise on Blood pressure and Pulmonary Variables (규칙적인 필라테스 운동이 심혈관 및 호흡 변인에 미치는 영향)

  • Lee, Gyu-Chang;Lee, Dong-Yeop;Yu, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3088-3095
    • /
    • 2011
  • The purpose of this study was to investigate the effects of Pilates exercises on the improvement of blood pressure and respiratory function. 36 subjects which were randomly divided into Pilates exercises group(n=18) and control group(n=18). Subjects in the Pilates exercises group were regularly participated in Pilates exercise program for 8 weeks. We were measured the blood pressure and respiratory function such as blood pressure, VO2max, METs, and Anaerobic threshold at before and after the experiment. After 8 weeks, in Pilate exercises group, there were significant improvement on blood pressure and respiratory function except the diastolic blood pressure. And subjects participated in Pilates exercise group were significantly improved compared to control group on systolic blood pressure, VO2max, METs, and Anaerobic threshold. But in control group, there were no significant differences. In conclusion, regular participation in Pilates exercises improved the blood pressure and respiratory function. These results suggest that Pilates exercise is the method that replace aerobic exercise.

Implementation of the Blood Pressure and Blood Flow Variation Rate Detection System using Impedance Method (임피던스법을 이용한 혈압 및 혈류 변화량 검출 시스템 구현)

  • Ro, Jung-Hoon;Bae, Jin-Woo;Ye, Soo-Young;Shin, Bum-Joo;Jeon, Gye-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1926-1938
    • /
    • 2009
  • In this study, detection system of the blood flow variation rate was implemented using the variation effect of bio electric impedance at time of the blood pressure measurement by means of impedance method. The blood pressure measurement was performed by the oscillometric method. The mean arterial pressure was calculated using maximum amplitude algorithm. The systolic and diastolic pressure were estimated by establishment of the various characteristic ratio according to mean arterial pressure range. Alternative static current source and lock_in amplifier were introduced to impedance measurement. The variation of blood volume was measured using variation bio impedance according to induced cuff pressure at measuring area.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Correlation of Peak Time Shift in Blood Pressure Waveform and PPG Based on Compliance Change Analysis in RLC Windkessel Model

  • Choi, Wonsuk;Cho, Jin-Ho
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.529-537
    • /
    • 2017
  • We explored how changes in blood vessel compliance affected the systolic rise time (SRT) of the maximum blood pressure (BP) peak wave and the diastolic fall time (DFT) of the minimal BP peak wave, compared to photoplethysmograpic (PPG) parameters, using a two-compartment, second-order, arterial Windkessel model. We employed earlier two-compartment Windkessel models and the components thereof to construct equivalent blood vessel circuits, and reproduced BP waveforms using PSpice technology. The SRT and DFT values were obtained via circuit simulation, considering variations in compliance (the dominant influence on blood vessel parameters attributable to BP changes). And then performed regression analysis to identify how compliance affected the SRT and DFT. We compared the SRTs and DFTs of BP waves to the PPG values by reference to BP changes in each subject. We confirmed that the time-shift propensities of BP waves and the PPG data were highly consistent. However, the time shifts differed significantly among subjects. These simulation and experimental results allowed us to construct an initial trend curve of individual BP peak time (measured via wrist PPG evaluations at three arm positions) that facilitated accurate individual BP estimations.

A Numerical Analysis on the Motion of Mechanical Heart Valve(MHV) and Characteristics of Blood Flow in an Elastic Blood Vessel (탄성혈관 내 기계식 인공심장판막(MHV)의 거동 및 혈액 유동 특성에 관한 수치해석적 연구)

  • Bang Jin-Seok;Choi Choeng-Ryul;Kim Chang-Nyung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.154-161
    • /
    • 2005
  • In this study, the leaflet motion of a mechanical heart valve and the characteristics of two-dimensional transient blood flow in an elastic blood vessel have been numerically investigated by using fluid-structure interaction method. Here, blood has been assumed as a Newtonian, incompressible fluid. Pressure profiles have been used as boundary conditions at the ventricle and the aorta. As a result, closing motion of the leaflet is faster than opening one. While opening angles of leaflet grow up, vortex is detected at the sinus and backward of the leaflets. When the leaflet is fully closed, vortex is detected at the ventricle and at that moment maximum displacement of the elastic blood vessel is observed in the vicinity of the sinus region. Maximum displacement is caused in association with the blood flow that is oriented toward the elastic blood vessel.

A Study on Effect of Residual Stress on Stress Distribution of Arterial Walls Under High Blood Pressure (잔류응력 효과를 고려한 고혈압 상태에 있는 혈관벽 내의 응력분포에 대한 연구)

  • Choi, Jae-Woo;Choi, Deok-Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1219-1227
    • /
    • 2011
  • Due to recent changes in living conditions, people who suffer from vascular disease have been increasing. As a result, several kinds of procedures to treat diseases of the blood vessels are being carried out and the epidemiological analysis and interpretation is needed. In this paper, the mechanical behavior of blood vessels based on hyperelastic model were evaluated. The stress distributions in the arterial walls subjected to both normal blood pressure and high blood pressure are studied along with different opening angles representing as the effect of the residual stress. As a result, when applied to residual stress effects in blood vessels to act maximum stress compared to as the absence of residual stress effect about 50% stresses can be reduced. When high blood pressure was the normal blood pressure acting on the blood vessel wall that twice stress can be confirmed.

Maximum exercise in 20 men Common carotid artery blood flow velocity impact (20대 남성에서 최대운동이 뇌로가는 혈관인 총경동맥 혈류 속도에 미치는 영향)

  • Kim, Ji-Won
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.5-12
    • /
    • 2009
  • Arterial blood from the heart chonggyeong passed directly to the cerebral arteries and the blood circulation is important, especially in arteries that prevent blood flow there are several variables. Among the variables the average flow velocity, pulse index, and blood flow resistance and which variables, double maekbakjisuna systolic and diastolic blood flow resistance index at the maximum rate and blood pressure associated with this because they are important variables, The change of variables such as speed noehyeolryu There are observations about the non-invasive ultrasound measurements using Doppler noehyeolryu uses. Up to 20 men in the exercise of noeroganeun hyeolryuin chonggyeong arteries to increase blood flow rates can be found.

  • PDF