• 제목/요약/키워드: maximum allowable load

검색결과 138건 처리시간 0.023초

엘리베이터 설치 작업용 시스템 비계의 구조 성능 평가 (Structural Performance Evaluation of System Scaffolding for Elevator Installation Work)

  • 황종문;이기열
    • 한국안전학회지
    • /
    • 제38권3호
    • /
    • pp.61-68
    • /
    • 2023
  • This study performed a structural performance evaluation of a system scaffolding for elevator installation work developed in previous studies. The structural performance was evaluated via a structural test conducted to apply the working load specified in the design standard. The deflection of the horizontal member and the stress of each member constituting the system scaffolding were measured. Consequently, the structural safety evaluation including structural behavior and required performance was performed using the deflection and stresses measured from the structural test. The structural test and safety evaluation results based on the heavy working load corresponding to the design load indicated that the deflection, which is the performance criterion of the horizontal member, did not exceed the allowable value. Further, each member's stress, which is a safety evaluation indicator, did not exceed the allowable strength for both horizontal and vertical members with bending behavior and fordable bracing with tensile behavior, while also satisfying the required safety factor. In addition, the results confirmed the safety against deformation, partial damage, and destruction owing to excessive and maximum load. Therefore, the system scaffolding developed in this study satisfies both the structural performance and safety required by the design standards; thus, it can be applied to elevator installation work sites.

원통형 저장탱크의 음향방출시험 (Acoustic Emission Testing in Cylindrical-Type Storage Tank)

  • 권정락;류근준;이태희;김지윤
    • 한국가스학회지
    • /
    • 제4권1호
    • /
    • pp.9-15
    • /
    • 2000
  • 원통형 톨루엔 저장탱크의 구조결함을 조사하기 위하여 음향방출시험을 수행하였다. 원통형 저장탱크는 고장력강으로 제작되었으며, 최근에 저장탱크의 하부 1 및 2단은 전면 보수되었다. 음향방출은 최대설계하중의 $75{\~}84\%$ 레벨영역에서 하중절차에 따라 실시간으로 모니터링 되었다. 시험결과는 순수 음향방출뿐만 아니라 유사 음향방출특성도 보여준다. 밸브잡음으로 판단되는 유사 방출들은 하중과는 무관하게 밸브잠금과정에서 과도적으로 발생되었다. 충수과정에서 발생된 순수 음향방출들은 결함에 기인하며, $75{\~}84\%$의 시험하중영역에서는 성장을 하지 않는 것으로 평가되었다. 이 결함들은 활성센서들을 중심으로 수행된 방사선시험을 통하여 용접균열과 기공인 것으로 밝혀졌다.

  • PDF

압축력을 받는 선체판의 경계조건에 따른 탄소성거동에 관한 연구 (A Study on the Elasto-Plasticity Behaviour of a Ship's Plate under Thrust According to Boundary Condition)

  • 고재용;박주신;박성현
    • 해양환경안전학회지
    • /
    • 제10권1호
    • /
    • pp.29-33
    • /
    • 2004
  • 지금까지의 강구조설계에서는 일반적인 탄성좌굴개념을 적용하고 있다. 왜냐하면 현재까지의 실적선의 데이터와 경험적인 방법에 의해 도출된 여러 가지 룰에 의한 데이터가 상당히 신뢰할만한 정도를 갖고 있기 때문이라고 판단하기 때문이다. 그러나, 최근들어 판두께가 박판인 고장력강재가 선체에 폭넓게 사용되어지면서 탄성좌굴발생 시점이 빨라졌으며 이에따른 탄소성거동을 정확히 예측할 필요성이 대두되고 있다. 이에 본 연구에서는 선체의 이중저 판넬구조에서 압축하중을 받을때의 실제판부재의 주변지지조건을 네가지로 이성화하여 해석하였으며, 이때 실제 필연적으로 존재하게 되는 열가공에 의한 비대칭형 초기처짐을 적용하였고, 비선형해석기법으로서는 Arc-length method를 적용하였고 해석코드는 범용유한요소법 소프트웨어로 잘 알려진 ANSYS를 사용하였다.

  • PDF

축방향 인장력을 받는 더블앵글 접합부의 강성 및 강도 예측모델 (Prediction Models for the Stiffness and the Strength of a Double Angle Connection Subjected to Tension)

  • 양재근;이길영;천지원
    • 한국강구조학회 논문집
    • /
    • 제19권2호
    • /
    • pp.201-210
    • /
    • 2007
  • 더블앵글 접합부는 충분한 강성 및 강도를 갖추어 작용하중을 잘 지탱할 수 있도록 설계되어야 한다. 따라서 구조설계자는 더블앵글 접합부의 강성 및 강도에 영향을 미치는 여러 변수들을 파악하여 접합부 설계에 반영하여야 한다. 본 연구는 볼트 게이지 거리 및 볼트 개수 등의 변수가 축방향 인장력을 받는 더블앵글 접합부의 강성 및 강도에 미치는 영향을 파악하기 위하여 진행하였다. 이를 위하여 6개의 접합부 시험체를 제작하여 접합부 실험을 수행하였고, 접합부의 하중-변위 관계 곡선을 획득하였다. 또한, 접합부 실험결과를 바탕으로 축방향 인장력을 받는 더블앵글 접합부의 초기강성 및 설계하중을 예측할 수 있는 해석모델도 제안하였다. 이러한 접합부 강성 및 강도 예측모델은 지렛대 작용 효과의 영향도 고려하여 제안되었다.

원전 엘보우의 성능기반 안전여유도 분석 (Investigation of the Performance Based Structural Safety Factor of Elbows in Nuclear Power Plants)

  • 이성호;박치용;박재학
    • 대한기계학회논문집A
    • /
    • 제33권8호
    • /
    • pp.826-831
    • /
    • 2009
  • The piping systems in nuclear power plant are composed of various typed pipes such as straight, elbow pipe, branch and reducer etc. The elbow is connected from straight pipe to another pipes in order to establish the complicated piping system. Elbow is one of very important components considering management of wall thinning degradation. It is however applied by various loads such as system pressure, earthquake, postulated break loading and many transient loads, which provoke simply the internal pressure, bending and torsional stress. In this study, firstly pipes in the secondary system of the nuclear power plant are classified as pipe size and type for selecting the investigating range. Next, a large number of finite element analysis considering the all typed dimensions of commercial pipe has been performed to find out the behavior of TES(twice elastic slop) plastic load of elbows, which is based on evaluation of the structural safety factor. Finally performance based structural safety factor was investigated comparing with maximum allowable load by construction code.

Geogrid로 보강된 점토지반에 축조된 대상기초의 반복하중하에서의 침하거동 (Settlement Behavior of Strip Foundation on Geogrid Reinforced Clay under Cyclic Loading)

  • 신은철;다스브라지앰
    • 한국지반공학회지:지반
    • /
    • 제11권3호
    • /
    • pp.27-36
    • /
    • 1995
  • 지오흐리드로 보강된 포화점토상에 축조된 줄기초가 낮은 빈도의 반복하중을 받았을시 발생 되는 열구침하량을 산정하기위한 실내모형 실험을 실시하였다. 실험을 실시하는 과정에서 초기 단계에는 기초에 허용정적 하중을 가하였고 연속적으로 반복하중을 가하였다. 정적하중과 반복 하중강도에 따른 기초의 최대영구침하량에 관하여 기술하였다.

  • PDF

Design Re-engineering of the Lower Support Structure of the APR1400 Reactor Internals

  • Tung, Nguyen Anh;Namgung, Ihn
    • 시스템엔지니어링학술지
    • /
    • 제13권1호
    • /
    • pp.25-31
    • /
    • 2017
  • This paper aims to evaluate the conservatism in the design of APR1400 (Advanced Pressurized water Reactor 1400 designed by KHNP) reactor internals component, the LSS (Lower Support Structure). Re-engineering of the LSS is done based on the system design condition data and applicable ASME code that was used for the original APR1400 design. Systems engineering approach is applied to design the LSS of APR1400 without refering APR1400 LSS dimensional parameters and tries to verify important design parameters of APR1400 LSS as well as the validity of the re-engineering design process as independent verification method of reactor component design. Systems engineering approach applied in this study following V-model approach. The re-engineered LSS design showed more than enough conservatism for static loading case. The maximum deflection of LSS is under 1mm (calculated value is 0.25mm) from 4000 mm diameter of LSS. Hence the deflection can be ignored in other reactor internals for structural integrity assessment. Especially the effect of LSS deflection on fuel assembly can be minimized and which is one of the main requirements of LSS design. It also showed that the maximum stress intensity is 2.36MPa for the allowable stress intensity of 60.1 MPa. The stress resulted from the static load is also very small compared to the maximum allowable stress intensity, hence there is more than enough conservatism in the LSS design.

소형 사보니우스형 수직축 풍력발전기의 내진검증 (Seismic Qualification Analysis of a Small Savonius Style Vertical Axis Wind Turbine)

  • 최영휴;강민규;박성훈
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.122-129
    • /
    • 2018
  • This study conducted a seismic qualification analysis of small savonius style vertical axis wind turbine(VAWT) using finite element method(FEM). The modal analysis was performed on the wind turbine structure to check the occurrence of resonance caused by the rotation of gearbox and windmill blades. Next, it conducted a seismic response spectrum analysis due to horizontal and vertical seismic load of required response spectrum of safe shutdown earthquake with 5 % damping(RRS/SSE 5%) of KS C IEC 61400 and conducted a static analysis due to deadweight and wind load. The total maximum stress of the VAWT structure was calculated by adding the maximum stresses due to each load case using the square root of the sum of the squares(SRSS) method. Finally, the structural safety of the VAWT structure was verified by comparing the total maximum stress and the allowable stress.

Determination of minimum depth of prestressed concrete I-Girder bridge for different design truck

  • Atmaca, Barbaros
    • Computers and Concrete
    • /
    • 제24권4호
    • /
    • pp.303-311
    • /
    • 2019
  • The depth of superstructure is the summation of the height of girders and the thickness of the deck floor. In this study, it is aim to determine the maximum span length of girders and minimum depth of the superstructure of prestressed concrete I-girder bridge. For this purpose the superstructure of the bridge with the width of 10m and the thickness of the deck floor of 0.175m, which the girders length was changed by two meter increments between 15m and 35m, was taken into account. Twelve different girders with heights of 60, 75, 90, 100, 110, 120, 130, 140, 150, 160, 170 and 180 cm, which are frequently used in Turkey, were chosen as girder type. The analyses of the superstructure of prestressed concrete I girder bridge was conducted with I-CAD software. In the analyses AASHTO LRFD (2012) conditions were taken into account a great extent. The dead loads of the structural and non-structural elements forming the bridge superstructure, prestressing force, standard truck load, equivalent lane load and pedestrian load were taken into consideration. HL93, design truck of AASHTO and also H30S24 design truck of Turkish Code were selected as vehicular live load. The allowable concrete stress limit, the number of prestressed strands, the number of debonded strands and the deflection parameters obtained from analyses were compared with the limit values found in AASHTO LRFD (2012) to determine the suitability of the girders. At the end of the study maximum span length of girders and equation using for calculation for minimum depth of the superstructure of prestressed concrete I-girder bridge were proposed.

경량 복합패널의 면내 전단 성능 평가 (Evaluation on In-plane Shear Strength of Lightweight Composite Panels)

  • 황문영;강수민;이병연;김성태
    • 한국산학기술학회논문지
    • /
    • 제20권1호
    • /
    • pp.9-20
    • /
    • 2019
  • 국내에서의 지진과 같은 자연재해의 발생횟수가 증가하고 있다. 이에 따라 재해, 재난 환경에 적합한 임시거주공간 혹은 피난시설의 필요성이 증대되고 있다. 본 연구에서는 경량 복합패널을 이용하여 기존 피난시설과는 차별화된 구호주거를 제작하고자 하였다. 이를 위해 경량 복합패널에 대한 구조적 성능을 검증하고자 하였으며, 패널에 대한 성능 시험 방법 중 ASTM E72 기준에 따른 면내 전단 강도 실험을 진행하였다. 실험 결과, 각 실험체가 면내 하중을 받을 때의 최대하중을 알아내었다. 모든 실험체는 가력 부분의 패널이 찢어지면서 실험이 종료되었다. 실험체의 초기 강성은 계산을 통해 예측한 강성과 일치하였다. 하지만 패널의 특성인 국부적인 찌그러짐과 찢어짐으로 인해 강성저하와 최종파괴가 발생하였다. 개구부가 있는 실험체들은 개구부의 위치와 형태에 따라 기본 실험체와 강성과 강도에서 차이를 보였다. 또한 모든 실험 결과를 종합하여 패널이 받는 최대하중과 힘을 받는 면적이 비례한다는 것을 확인하였다. 이를 통해 실험체들의 극한전단응력을 계산하였으며, 평균 극한전단응력을 산정하였다. 경량 복합패널의 평균 극한전단응력은 $0.047N/mm^2$이며, 이 값을 통해 패널의 면적에 따른 허용하중을 합리적으로 예측할 수 있는 근거를 제시하였다.