• Title/Summary/Keyword: maxillary sinus augmentation

Search Result 117, Processing Time 0.032 seconds

Study on the position of the posterior superior alveolar artery in relation to the performance of the maxillary sinus bone graft procedure in a Korean population

  • Park, Woo-Hyun;Choi, So-Young;Kim, Chin-Soo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.2
    • /
    • pp.71-77
    • /
    • 2012
  • Objectives: This study sought to investigate the positioning of the posterior superior alveolar artery in relation to the performance of the maxillary sinus bone graft procedure in a Korean population. Materials and Methods: We identified the position of the posterior superior alveolar artery relative to 93 maxillary sinuses in 58 patients and determined the distance from the inferior border of the artery in the premolar and molar areas to the alveolar ridge and sinus floor. Results: The mean distance from the alveolar ridge to the posterior superior alveolar artery in the dentate group ($20.62{\pm}3.05mm$ in the premolar region, $17.50{\pm}2.84mm$ in the molar region) was greater than as compared to the edentulous group ($18.83{\pm}2.79mm$ in the premolar region, $15.50{\pm}1.64mm$ in the molar region), and this difference was statistically significant (P<0.05). In contrast, there was no statistically significant difference (P>0.05) between the mean distance from the sinus floor to the posterior superior alveolar artery in the dentate group ($8.21{\pm}2.79mm$ in the premolar region, $7.52{\pm}2.07mm$ in the molar region) or in the edentulous group ($7.75{\pm}3.31mm$ in the premolar region, $7.97{\pm}2.31mm$ in the molar region). Conclusion: Prior to surgery, it is important to evaluate the position of the posterior superior maxillary artery by using computed tomography scans. The premolar area is safer than the molar area for performing the maxillary sinus bone graft without bleeding.

MORPHOMETRICS OF ALVEOLAR PROCESS AND ANATOMICAL STRUCTURES AROUND INFERIOR MAXILLARY SINUS FOR MAXILLARY IMPLANTATION (임플랜트 시술을 위한 치조돌기와 상악동 주변 구조물의 형태계측적 연구)

  • Park, Ju-Jin;Lee, Young-Soo;Paik, Doo-Jin;Park, Won-Hee;Yoo, Dong-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.228-239
    • /
    • 2007
  • Statement of problem: Following tooth loss, the edentulous alveolar process of maxilla is affected by irreversible reabsorption process, with progressive sinus pneumatization leads to leaving inadquate bone height for placement of endosseous implants. Grafting the floor of maxillary sinus by sinus lifting surgery and augmentation of autologous bone or alternative bone material is a method of attaining sufficient bone height for maxillary implants placement and has proven to be a highty successful. Purpose: This study was undertaken to clarify the morphometric characteristics of inferior maxillary sinus and alveolar process for installation of implants. Material and method: Nineteen skulls (37 sinuses, 10M / 9F) obtained from the collection of the department of anatomy and cell biology of Hanyang medical school were studied. The mean age of the deceased was 69.9 years (range 44 to 88 years). The distance between alveolar border and inferior sinus margin at each tooth, the height of alveolar process and the thickness of cortical bone of the outer and inner table of alveolar process and the inferior wall of maxillary sinus were measured. Results and Conclusion: 1. The septum of inferior maxillary sinus were observe 28 sides (76.%) and located at the third molar (52.6%) and the second molar (26.3%). The deepest points of inferior border of maxillary sinus were located the first or second molar. The distance between alveolar margin and the deepest point of inferior maxillary sinus is $9.7{\pm}4.9mm$. 2. The length of the outer table of alveolar process were $4.9\sim28.2mm$ and the shortest point was between the first and the second molors. The thickness of them were $0.9\sim3.2mm$. The length of the inner table of alveolar process were $7.4\sim25.8mm$ and the shortest point was between the first and the second molars. The thickness of the were $0.9\sim4.6mm$. The results of this study are useful anatomical data for installing of maxillary implants.

Histologic evaluation of low-intensity pulsed ultrasound effects on bone regeneration in sinus lift

  • Kim, Sang-Hun;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.6
    • /
    • pp.271-275
    • /
    • 2010
  • Purpose: Many techniques have been described for achieving vertical augmentation of the maxillary sinus. The aim of this study is to evaluate the effect of low-intensity pulsed ultrasound (LIPUS) to enhance bone regeneration after sinus floor elevation. Methods: The sinus lifting technique was performed through a lateral approach on 8 different sites of 5 patients (3 males and 2 females) and their mean age was 45.7 years old. The sites were randomly assigned to the control or test groups. The control group had 4 sites that received lateral sinus lifting procedure only, while the test group had 4 sites that received LIPUS application after the lateral sinus lifting procedure. 24-32 weeks (an average of 29 weeks) postoperatively, new bone formation in the augmented sinus sites was evaluated through histologic and histomorphometric analyses of the biopsy specimens obtained during implant placement. Results: In the test group, the mean percentage of newly formed bone was $19.0{\pm}2.8$%. In the control group, the mean percentage of newly formed bone was $15.2{\pm}3.1$%. The percentage of newly formed bone was approximately 4% higher in those cases where the sinus was treated by LIPUS than the percentage in those cases where it was not used. The difference was statistically significant. Conclusions: Within the scope of this study, low-intensity pulsed ultrasound application after sinus lifting appeared to have a significant effect on the development of new bone formation.

New bone formation in the maxillary sinus without bone grafts:Covering of lateral window with non-resorbable membrane or bony window (골이식재를 사용하지 않은 상악동 거상술:골창의 패쇄방법에 따른 치험례)

  • Son, Dong-Seok;Lee, Ji-Su;An, Mi-Ra;Sin, Hong-In
    • The Journal of the Korean dental association
    • /
    • v.46 no.4
    • /
    • pp.222-231
    • /
    • 2008
  • Various maxillary sinus floor augmentation techniques were common performed and in the most cases, many kinds of bone graft materials were used. The graft materials are autogenous bone or other biomaterials of human, animal or synthetic origin. But these cases report describes a new surgical technique by which dental implants are inserted in a void space created by elevating the sinus membrane without additional graft material in atrophic posterior maxilla. We created lateral bony window using piezoelectric device and elevated the schneiderian membrane in five patients and was repositioned with bony window in five patients, without any bone graft. From the clinical and histological results, it is found there is potential capacity for bone formation and placement of implants in the maxillary sinus without the use of bone grafts or bone substitutes.

  • PDF

Clinical Availability of Waters' Projection in Sinus Elevation Procedures (상악동 거상술 시 Waters' Projection의 유용성에 대한 임상적 연구)

  • Seo, Mi Hyun;Kim, Soung Min;Ha, Ji Young;Lee, Jeong Keun;Myoung, Hoon;Lee, Jong Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.2
    • /
    • pp.88-93
    • /
    • 2013
  • Purpose: Maxillary sinus elevation has been widely used to enable insertion of endosseous implants in severely resorbed maxilla. Maxillary sinusitis after this procedure was considered to be the major drawback, therefore, preoperative evaluation of paranasal sinus is considered to be important. In order to evaluate the condition of the sinus, we used Waters' projection. In this study, asymptomatic patients were evaluated by Waters' view, and compared to timing to assess the sinus cavity. Methods: The retrospective study was based on 14 patients who were performed sinus elevation surgery in Seoul National University Dental Hospital. These patients did not show any signs of maxillary sinusitis. These patients were taken Waters' view at preoperative, postoperative 1 day, 3 months, 6 months. In Waters' view, presence of air fluid level, radiopacity of sinus wall, or radiopacity of entire maxillary sinus were evaluated. The density, and sinus dimension changes were assessed using Adobe Photoshop CS5$^{(R)}$ (Adobe Systems Inc., San Jose, CA, USA). Results: Findings of Waters views in patients with clear maxillary sinus at preoperative time were followed by elevated sinus floor with transplanted bone, mucosal swelling, and air fluid level. At postoperative 3 months, and 6 months, the radiographic findings were similar to preoperative state. By contrast, patients with preoperative mucosal swelling, or haziness in sinus cavity showed radiopacity entire sinus in Waters' view. In cases of the patients who were treated with simultaneous treatment to mucosal swelling, good status of sinus cavity were found. Conclusion: Although Waters' projections provide the limited information, and is less sensitive method compared with computed tomography, it is simple, easy, and economical method to assess of maxillary sinus. We suggest using Waters' view as radiographic routine tool for evaluation of sinus condition, especially in the sinus elevation surgery.

Sinus augmentation using rhBMP-2-loaded synthetic bone substitute with simultaneous implant placement in rabbits

  • Joo, Myung-Jae;Cha, Jae-Kook;Lim, Hyun-Chang;Choi, Seong-Ho;Jung, Ui-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.2
    • /
    • pp.86-95
    • /
    • 2017
  • Purpose: The aim of this study was to determine the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded synthetic bone substitute on implants that were simultaneously placed with sinus augmentation in rabbits. Methods: In this study, a circular access window was prepared in the maxillary sinus of rabbits (n=5) for a bone graft around an implant (${\varnothing}3{\times}6mm$) that was simultaneously placed anterior to the window. Synthetic bone substitute loaded with rhBMP-2 was placed on one side of the sinus to form the experimental group, and saline-soaked synthetic bone substitute was placed on the other side of the sinus to form the control group. After 4 weeks, sections were obtained for analysis by micro-computed tomography and histology. Results: Volumetric analysis showed that the median amount of newly formed bone was significantly greater in the BMP group than in the control group ($51.6mm^3$ and $46.6mm^3$, respectively; P=0.019). In the histometric analysis, the osseointegration height was also significantly greater in the BMP group at the medial surface of the implant (5.2 mm and 4.3 mm, respectively; P=0.037). Conclusions: In conclusion, an implant simultaneously placed with sinus augmentation using rhBMP-2-loaded synthetic bone substitute can be successfully osseointegrated, even when only a limited bone height is available during the early stage of healing.

THE GRAFT HEIGHT CHANGES AFTER SINUS AUGMENTATION PROCEDURES USING DEPROTEINIZED BOVINE BONE MINERAL AND BETA-TRICALCIUM PHOSPHATE - A RETROSPECTIVE COMPARATIVE STUDY USING PANORAMIC RADIOGRAPHY (탈단백 우골과 제3인산칼슘을 이용한 상악동 골이식 후 이식재의 높이 변화 - 파노라마 방사선 사진을 이용한 후향적 대조 연구)

  • Kim, Jong-Sik;Park, Tae-Il;Seo, Hyun-Soo;Song, Yun-Jung;Hong, Soon-Min;Choi, Mee-Ra;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.4
    • /
    • pp.468-474
    • /
    • 2008
  • Purpose: Previous clinical investigations of sinus floor augmentation have demonstrated repneumatization of grafted sinus. The aim of this study is to evaluate and compare the height changes of sinus floor after grafting with deprotenized bovine bone mineral (DBBM) and beta tricalcium phosphate (TCP). Materials and methods: 34 sinuses in 28 patients were augmented with 100% DBBM or 100% TCP through lateral approaches. Sinusgraft height was measured before, immediately after, and 6 months after bone graft with panoramic radiography. Result: After 6 months, the decreases of graft heights were 14.53% for DBBM group and 15.15% for TCP group. There was no statistically significant difference. Discussion and Conclusion: Long-term stability of sinus-graft height represents an important factor for implant success. After the uses of DBBM and TCP for maxillary sinus floor augmentations, acceptable graft height maintenances were observed.

Radiographic study of the distribution of maxillary intraosseous vascular canal in Koreans

  • Lee, JuHyon;Kang, Nara;Moon, Young-Mi;Pang, Eun-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.1.1-1.4
    • /
    • 2016
  • Background: This study aimed to investigate the distribution and prevalence of intraosseous loop (anastomosis between posterior superior alveolar artery and infraorbital artery) in Koreans detected on computed tomography (CT) images taken prior to sinus augmentation surgery. Methods: From the 177 patients who underwent sinus augmentation with lateral approach at Ewha Womans University Department of Implant Dentistry, 284 CT scans were evaluated. The canal height (CH), ridge height (RH), and canal height from the sinus floor (CHS) were measured on para-axial views at the first premolar, first molar, and second molar. The horizontal positions of the bony canals in the lateral wall were also classified. One-way analysis of variance (ANOVA) and t test were used to estimate the statistical differences (p < 0.05). Results: The intraosseous loops were detected in 92 CT scans (32 %). The mean vertical height of the bony canals from the alveolar crest (CH) was $23.45{\pm}2.81$, $15.92{\pm}2.65$, and $16.61{\pm}2.92mm$ at the second premolar, first molar, and second molar, respectively. In the horizontal positions of the bony canals, intraosseous type was the most predominant. The canal heights more than 15 mm and less than 17 mm were most prevalent (33.7 %) and those under 13 mm were 12.0 %. Conclusions: The radiographic findings in this study could be used to decide the lateral osteotomy line avoiding potential vascular complication. However, only one third of the canals could be detected in CT scans; a precaution should be taken for the possibility of severe bleeding during lateral osteotomy.