• 제목/요약/키워드: matlab/simulink

검색결과 1,126건 처리시간 0.028초

전자식 비례 압력제어밸브 내 오일 오염 입자 제거 제어 알고리즘 검증 (Verification of Control Algorithm for Removing Oil Contaminant Factor from Proportional Pressure Control Valve)

  • 천수환;박진감;장경제;심성보;장민호;이진웅
    • 드라이브 ㆍ 컨트롤
    • /
    • 제18권4호
    • /
    • pp.1-8
    • /
    • 2021
  • An electro proportional pressure control valve is mainly used to control the clutch of an agricultural tractor's automatic transmission. During transmission, the operating, hydraulic oil is mix with many kinds of contaminants. The contaminants can be trapped between the valve body and spool of the proportional pressure control valve leading to abnormal operating conditions and finally critical damage to the transmission hydraulic system. The present study aimed to verify the valve control algorithm as a basic study of developing control logic that removes contaminants between the spool and the body of the proportional pressure control valve. To develop the algorithm, MATLAB/SIMULINK was used. PWM method was used to control the applied solenoid coil current. The effectiveness of the algorithm was verified by comparing the actual pressure of the normal valve with the actual pressure of the abnormal valve. Based on the present study findings, when the algorithm was applied, the response of the valve pressure according to the current became stable and oil contaminated particles were removed. In the future study, the control algorithm will be optimized for the stability of the proportional pressure reducing valve, and it will be verified in consideration with the driving of the clutch.

활성슬러지 공정을 위한 모델링과 지능제어의 적용 (Modeling and Intelligent Control for Activated Sludge Process)

  • 천성표;김봉철;김성신;김창원;김상현;우혜진
    • 대한환경공학회지
    • /
    • 제22권10호
    • /
    • pp.1905-1919
    • /
    • 2000
  • 활성슬러지 공정에 기반을 둔 연속식반응기는 시스템이 가진 고유한 비선형성뿐만 아니라 계절, 기후 등의 환경변화에 따른 유입수의 유량 및 특성 등의 외부적인 조건의 변화를 고려하여 제어하여야 한다. 수학적 모델링 과정에서 고려하지 못했거나 무시되었던 부분을 포함한 시스템에 관련된 특징과 한정된 공간에서 기본적인 제어방법에 의한 현재의 운전방법을 고려하여 불 때 활성슬러지 공정은 개선할 수 있는 여지가 많다. 또한 숙련된 운전자의 지식을 구현할 수 있는 지능제어기법을 적용하여 전체적인 공정의 효율 향상을 도모할 수 있다. 제어방법의 적용에 앞서 제어대상공정인 활성슬러지 공정을 분석하여 이를 $Matlab^{(R)}5.3/Simulink^{(R)}3.0$을 이용하여 연속식반응기 모델을 구현하였다. IWA(International Water Association)와 COST(European Cooperation in the field of Scientific and Technical Research)에서 제시한 정상상태의 유입수 특성을 이용하여 모델의 정확성을 검증하였다. 본 논문에서는 이미 현장에서 사용중인 제어기법의 구현 및 성능 평가뿐만 아니라 다양한 고급제어기법들을 적용하여 새롭게 제안한 제어기법들이 실제 폐수처리장에 적용가능한지 여부를 검증하였다. 제어방법으로는 현장에서 일반적으로 사용되고 있는 비례-적분-미분제어기(Proportional-Integral-Derivative Controller; PID controller)와 PID제어기가 가진 장점과 퍼지 논리 제어기법이 가진 장점을 결합함과 동시에 제어기의 성능 향상 및 경제성을 높일 수 있는 퍼지 PID이득 조절기(fuzzy PID gain tuner)와 퍼지 셋포인트 변환기(fuzzy setpoint changer)를 적용하여 봄으로써 외란에 대해 강인한 제어기 설계의 가능성을 검증하였다.

  • PDF

외란의 변화가 있는 PMSM의 강인하고 정밀한 위치 제어에 대한 연구 (A Study on Robust and Precise Position Control of PMSM under Disturbance Variation)

  • 이익선;여원석;정성철;박건호;고종선
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1423-1433
    • /
    • 2018
  • Recently, a permanent magnet synchronous motor of middle and small-capacity has high torque, high precision control and acceleration / deceleration characteristics. But existing control has several problems that include unpredictable disturbances and parameter changes in the high accuracy and rigidity control industry or nonlinear dynamic characteristics not considered in the driving part. In addition, in the drive method for the control of low-vibration and high-precision, the process of connecting the permanent magnet synchronous motor and the load may cause the response characteristic of the system to become very unstable, to cause vibration, and to overload the system. In order to solve these problems, various studies such as adaptive control, optimal control, robust control and artificial neural network have been actively conducted. In this paper, an incremental encoder of the permanent magnet synchronous motor is used to detect the position of the rotor. And the position of the detected rotor is used for low vibration and high precision position control. As the controller, we propose augmented state feedback control with a speed observer and first order deadbeat disturbance observer. The augmented state feedback controller performs control that the position of the rotor reaches the reference position quickly and precisely. The addition of the speed observer to this augmented state feedback controller compensates for the drop in speed response characteristics by using the previously calculated speed value for the control. The first order deadbeat disturbance observer performs control to reduce the vibration of the motor by compensating for the vibrating component or disturbance that the mechanism has. Since the deadbeat disturbance observer has a characteristic of being vulnerable to noise, it is supplemented by moving average filter method to reduce the influence of the noise. Thus, the new controller with the first order deadbeat disturbance observer can perform more robustness and precise the position control for the influence of large inertial load and natural frequency. The simulation stability and efficiency has been obtained through C language and Matlab Simulink. In addition, the experiment of actual 2.5[kW] permanent magnet synchronous motor was verified.

Control and Analysis of an Integrated Bidirectional DC/AC and DC/DC Converters for Plug-In Hybrid Electric Vehicle Applications

  • Hegazy, Omar;Van Mierlo, Joeri;Lataire, Philippe
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.408-417
    • /
    • 2011
  • The plug-in hybrid electric vehicles (PHEVs) are specialized hybrid electric vehicles that have the potential to obtain enough energy for average daily commuting from batteries. The PHEV battery would be recharged from the power grid at home or at work and would thus allow for a reduction in the overall fuel consumption. This paper proposes an integrated power electronics interface for PHEVs, which consists of a novel Eight-Switch Inverter (ESI) and an interleaved DC/DC converter, in order to reduce the cost, the mass and the size of the power electronics unit (PEU) with high performance at any operating mode. In the proposed configuration, a novel Eight-Switch Inverter (ESI) is able to function as a bidirectional single-phase AC/DC battery charger/ vehicle to grid (V2G) and to transfer electrical energy between the DC-link (connected to the battery) and the electric traction system as DC/AC inverter. In addition, a bidirectional-interleaved DC/DC converter with dual-loop controller is proposed for interfacing the ESI to a low-voltage battery pack in order to minimize the ripple of the battery current and to improve the efficiency of the DC system with lower inductor size. To validate the performance of the proposed configuration, the indirect field-oriented control (IFOC) based on particle swarm optimization (PSO) is proposed to optimize the efficiency of the AC drive system in PHEVs. The maximum efficiency of the motor is obtained by the evaluation of optimal rotor flux at any operating point, where the PSO is applied to evaluate the optimal flux. Moreover, an improved AC/DC controller based Proportional-Resonant Control (PRC) is proposed in order to reduce the THD of the input current in charger/V2G modes. The proposed configuration is analyzed and its performance is validated using simulated results obtained in MATLAB/ SIMULINK. Furthermore, it is experimentally validated with results obtained from the prototypes that have been developed and built in the laboratory based on TMS320F2808 DSP.

파력발전용 선형발전시스템의 벡터제어 (Vector Control for Wave Power Generation System using Permanent Magnet Linear Synchronous Generator)

  • 박준성;현병조;윤준보;이주;최장영;최종수;홍기용
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제19권2호
    • /
    • pp.120-128
    • /
    • 2016
  • 파력발전은 파도의 위치에너지와 운동에너지를 이용한 발전방식으로 본 논문에서는 선형동기발전기를 이용한 파력발전시스템에 대하여 연구를 진행하였다. 파력 발전시스템을 분석하기 위해서는 부이의 운동과 부이와 연결과 발전기의 운동을 모델링하는 것이 매우 중요하다. 본 논문에서는 발전시스템의 분석을 위하여 선형발전기와 컨버터 시스템의 모델링을 진행하였다. 선형발전기와 컨버터 시스템의 전압 방정식 및 부이의 운동방정식을 이용하여 2상 회전좌표계에서의 벡터제어기법을 적용하여 댐핑기반의 제어기 구성을 제안한다. 파도 에너지로부터 전기에너지를 추출하기 위해서 파력발전기의 전류제어를 통해 댐핑을 적절히 조절할 수 있는 벡터제어기법 구성에 대해 제안한다. 최종적으로 제안된 제어기의 검증을 위하여 MATLAB/Simulink를 이용한 2상 회전좌표계에서의 벡터제어기의 시뮬레이션을 수행하였으며 선형 발전기 축소모델와 PCS 축소모델을 통한 실험을 수행하였다.

삼상 다중 접지 배전계통에서 활선로 추적 방법 (Live Lines Tracing Method in Power Distribution System with 3-phase-4 wires)

  • 정언붕;변희정;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.559-562
    • /
    • 2017
  • 도심에서 배전선로는 지중과 가공 선로의 구성, 연가, 건물과 나무로 인한 시야 방해로 추적하기가 어렵다. 이러한 3상 4선식 배전계통에서 특정 수용가가 어떤 변압기 또는 어떤 선로로부터 공급되는지를 결정하는 것이 현장의 전기 기술자에게 어려운 문제다. 배전선로 사이의 부하 평형 등을 위해 선로의 정확한 추적기술이 필요하다. 기존의 임펄스 전류를 사선에 주입하는 방식과는 다르게 활선에 고주파 신호를 주입하는 식별 방법을 제안한다. 배전선로에 고주파 전력 신호를 주입하여 분석 한 결과 고주파 신호는 배전선에서 전달 능력에 한계 능력을 갖는다. 보통 배전계통의 전력 변압기는 그러한 고주파 신호의 전달을 차폐하게 된다. 이러한 전송제한 특성을 사용하여 변압기와 배전선로를 식별하는 방법을 제안한다. 측정 배전선로의 양단에서 전기신호에 대한 동일 선로 여부를 판별하는 방식이다. 어려운 점은 원격 두 지점이 동기화되어야 하는데, 동기화 시간을 제공하는 GPS를 사용하지 않고 두 지점에 동기화를 달성한다. 새로운 형태의 선로 및 변압기 식별시스템을 설계 및 구현한다. 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위해서 일반 상업용 건물에서 실험이 행하여진다.

  • PDF