• Title/Summary/Keyword: materials penetration loss

Search Result 39, Processing Time 0.032 seconds

Performance Analysis of Communication Systems with Penetration Loss of Building Materials in Pico-cell Environment (실내 피코셀 환경에서 건물 재질의 투과손실을 고려한 통신 시스템의 성능 분석)

  • Lee Yang-Sun;Kang Heau-Jo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.920-926
    • /
    • 2005
  • In this paper, we analyzed the effect by building materials in the case of floor cell design and the penetration loss value by material in each frequency bands through an experiment in high building. Specially, the penetration loss measured about interference signal that is received to direct path, interference signal and flowed in slant path. Also, we analyzed system performance according to path of standard Cell received interference signal.

Influence of supplementary cementitious materials on strength and durability characteristics of concrete

  • Praveen Kumar, V.V.;Ravi Prasad, D.
    • Advances in concrete construction
    • /
    • v.7 no.2
    • /
    • pp.75-85
    • /
    • 2019
  • The present study is focused on the mechanical and durability properties of ternary blended cement concrete mix of different grades 30 MPa, 50 MPa and 70 MPa. Three mineral admixtures (fly ash, silica fume and lime sludge) were used as a partial replacement of cement in the preparation of blended concrete mix. The durability of ternary blended cement concrete mix was studied by exposing it to acids HCl and $H_2SO_4$ at 5% concentration. Acid mass loss factors (AMLF), acid strength loss factor (ASLF) and acid durability factor (ADF) were determined, and the results were compared with the control mix. Chloride ions penetration was investigated by conducting rapid chlorination penetration test and accelerated corrosion penetration test on control mix and ternary blended cement concrete. From the results, it was evident that the usage of these mineral admixtures is having a beneficiary role on the strength as well as durability properties. The results inferred that the utilization of these materials as a partial replacement of cement have significantly enhanced the compressive strength of blended concrete mix in 30 MPa, 50 MPa and 70 MPa by 42.95%, 32.48% and 22.79%. The blended concrete mix shown greater resistance to acid attack compared to control mix concrete. Chloride ion ingress of the blended cement concrete mix was low compared to control mix implying the beneficiary role of mineral admixtures.

Development of GMAW Process with Twin Torch for Wide Overlay using Compound Filler Plate (분말 용가재판을 사용한 광폭 오버레이용 트윈토치 GMAW 공정개발)

  • Hwang, Kyu-Min;Kim, Sung-Deok;Jung, Byung-Ho;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.26 no.4
    • /
    • pp.44-49
    • /
    • 2008
  • Generally, wear plate is steel plate having improved surface contact strength and impact strength by surface hardening which is welded using materials with good corrosion resistance, wear resistance and thermal resistance property. CFP GMAW(Compound Filler Plate Gas Metal Arc Welding) is the cladding method using GMAW with the CFP, which is bound with waterglass, on the substrate. It has advantages of reducing compound powder loss, uniform penetration, and preventing hardness decrease. To develope mass production technique of CFP GMAW process for production of high quality wear plate, the method for controling shallow penetration and increasing productivity is required. In this study, twin torch method applied to CFP GMAW process for increasing productivity. And the method was developed by controling penetration control, CFP dry time, gas formation flux and water glass concentration. As a result, applying twin torch method to CFP GMAW process was possible and high quality wide bead could be made without overlap joint.

Relationships between dielectric properties and characteristics of impregnated and activated samples of potassium carbonate-and sodium hydroxide-modified palm kernel shell for microwave- assisted activation

  • Alias, Norulaina;Zaini, Muhammad Abbas Ahmad;Kamaruddin, Mohd Johari
    • Carbon letters
    • /
    • v.24
    • /
    • pp.62-72
    • /
    • 2017
  • The aim of this work was to evaluate the dielectric properties of impregnated and activated palm kernel shells (PKSs) samples using two activating agents, potassium carbonate ($K_2CO_3$) and sodium hydroxide (NaOH), at three impregnation ratios. The materials were characterized by moisture content, carbon content, ash content, thermal profile and functional groups. The dielectric properties were examined using an open-ended coaxial probe method at various microwave frequencies (1-6 GHz) and temperatures (25, 35, and $45^{\circ}C$). The results show that the dielectric properties varied with frequency, temperature, moisture content, carbon content and mass ratio of the ionic solids. PKSK1.75 (PKS impregnated with $K_2CO_3$ at a mass ratio of 1.75) and PKSN1.5 (PKS impregnated with NaOH at a mass ratio of 1.5) exhibited a high loss tangent ($tan{\delta}$) indicating the effectiveness of these materials to be heated by microwaves. $K_2CO_3$ and NaOH can act as a microwave absorber to enhance the efficiency of microwave heating for low loss PKSs. Materials with a high moisture content exhibit a high loss tangent but low penetration depth. The interplay of multiple operating frequencies is suggested to promote better microwave heating by considering the changes in the materials characteristics.

The Corrosion Behavior of Li/K Carbonate Melts with CaCO3 Additives on Separator Plate in the Molten Carbonate Fuel Cell in the Anode Environments

  • Cho, Kyehyun;Lee, Chul-Hwan;Sung, Zu-Hwan
    • Corrosion Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.129-136
    • /
    • 2006
  • High temperature corrosion behavior of AISI-type 316L stainless steel for the MCFC(molten carbonate fuel cell) bipolar application was studied by immersion test and penetration attack method in anode environment ($650^{\circ}C$, $Li_2CO_3/K_2CO_3=62/38$ mol%, $H_2/CO_2=80/20$ vol%) without or with different $CaCO_3$ content. Not only immersion test method but also morphological observation of samples in the carbonate melts are adopted as experimental methods. With aid of the morphological observation of cross section of samples immersed in a carbonate melt was possible to obtain penetration attack. The concentration effect of $CaCO_3$ inhibitor was investigated in order to verify the optimum concentration for practical application in MCFC stack operation. The corrosion rate in the presence of $CaCO_3$ was proven to be decreased as a function of $CaCO_3$ concentration. The corrosion rate in the presence of $CaCO_3$ was measured with a value of 6.9 mpy which is 2.4 times lower than that of inhibitor-free electrolyte. The cross section microscopy revealed that the internal penetration by oxidation in molten carbonate is very severe. In this case, the attack was occurred not only dissolution loss in the electrolyte by corrosion reaction but also weight gain through oxide layer by internal penetration.

Investigation of Likelihood of Cracking in Reinforced Concrete Bridge Decks

  • ElSafty, Adel;Abdel-Mohti, Ahmed
    • International Journal of Concrete Structures and Materials
    • /
    • v.7 no.1
    • /
    • pp.79-93
    • /
    • 2013
  • One of the biggest problems affecting bridges is the transverse cracking and deterioration of concrete bridge decks. The causes of early age cracking are primarily attributed to plastic shrinkage, temperature effects, autogenous shrinkage, and drying shrinkage. The cracks can be influenced by material characteristics, casting sequence, formwork, climate conditions, geometry, and time dependent factors. The cracking of bridge decks not only creates unsightly aesthetic condition but also greatly reduces durability. It leads to a loss of functionality, loss of stiffness, and ultimately loss of structural safety. This investigation consists of field, laboratory, and analytical phases. The experimental and field testing investigate the early age transverse cracking of bridge decks and evaluate the use of sealant materials. The research identifies suitable materials, for crack sealing, with an ability to span cracks of various widths and to achieve performance criteria such as penetration depth, bond strength, and elongation. This paper also analytically examines the effect of a wide range of parameters on the development of cracking such as the number of spans, the span length, girder spacing, deck thickness, concrete compressive strength, dead load, hydration, temperature, shrinkage, and creep. The importance of each parameter is identified and then evaluated. Also, the AASHTO Standard Specification limits liveload deflections to L/800 for ordinary bridges and L/1000 for bridges in urban areas that are subject to pedestrian use. The deflection is found to be an important parameter to affect cracking. A set of recommendations to limit the transverse deck cracks in bridge decks is also presented.

Dielectric Properties of Fresh Ginseng Determined by an Open-Ended Coaxial Probe Technique (수삼의 마이크로파 유전특성)

  • Hong, Seok-In;Lee, Boo-Yong;Park, Dong-June;Oh, Seung-Yong
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.470-474
    • /
    • 1996
  • The dielectric properties, dielectric constant (${\varepsilon}‘$) and loss factor (${\varepsilon}’$), of skin and pulp of fresh ginseng were measured from $25^{\circ}C$ to $67^{\circ}C$ using an open-ended coaxial probe technique for 915 MHz and 2450 MHz. Pulp and skin had dielectric constant of $30{\sim}64$ and loss factor between 10 and 20, each variable having a respective frequency dependence typical of materials with high water content. Although the loss factor was nearly constant, the dielectric constant increased as moisture content increased. The dielectric constant of ginseng pulp increased as temperature increased (temperature ${\leq}56^{\circ}C$), but any significant differences were not found in skin dielectric properties. Penetration depth for fresh ginseng were about 2 cm at 91.5 MHz and 1cm at 2450 MHz.

  • PDF

Durability Properties and Microstructure of Ground Granulated Blast Furnace Slag Cement Concrete

  • Divsholi, Bahador Sabet;Lim, Tze Yang Darren;Teng, Susanto
    • International Journal of Concrete Structures and Materials
    • /
    • v.8 no.2
    • /
    • pp.157-164
    • /
    • 2014
  • Ground granulated blast-furnace slag (GGBS) is a green construction material used to produce durable concrete. The secondary pozzolanic reactions can result in reduced pore connectivity; therefore, replacing partial amount of Portland cement (PC) with GGBS can significantly reduce the risk of sulfate attack, alkali-silica reactions and chloride penetration. However, it may also reduce the concrete resistance against carbonation. Due to the time consuming process of concrete carbonation, many researchers have used accelerated carbonation test to shorten the experimental time. However, there are always some uncertainties in the accelerated carbonation test results. Most importantly, the moisture content and moisture profile of the concrete before the carbonation test can significantly affect the test results. In this work, more than 200 samples with various water-cementitious material ratios and various replacement percentages of GGBS were cast. The compressive strength, electrical resistivity, chloride permeability and carbonation tests were conducted. The moisture loss and microstructure of concrete were studied. The partial replacement of PC with GGBS produced considerable improvement on various properties of concrete.

An analysis of the ion penetration phenomena in amorphous $Se_{75}Ge_{25}$ thin film (비정질 $Se_{75}Ge_{25}$박막으로의 이온침투 현상 해석)

  • 이현용;정홍배
    • Electrical & Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.389-396
    • /
    • 1994
  • The bilayer film of Ag/a-S $e_{75.G}$ $e_{25}$ and the monolayer film of a-S $e_{75.G}$ $e_{25}$ act as a negative-type and a positive-type resist in focused ion beam lithography, respectively. Using a model which takes into account the ion stopping power, the ion projected range, the ion concentration implanted into resists and the ion transmission coefficient, etc., the ion resist parameters are calculated for a broad range of ion energies and implanted doses. Ion sources of A $r^{+}$, S $i^{++}$ and G $a^{+}$ are used to expose resists. As the calculated results, the energy loss per unit distance by Ga'$^{+}$ ion is about 10$^{3}$[keV/.mu.M] and nearly constant for all energy range. Especially, the projected range and struggling for 80[keV] G $a^{+}$ ion energy are 0.0425[.mu.m] and 0.020[.mu.m], , respectively and the resist thickness of a-S $e_{75}$ G $e_{25}$ to minimize the ion penetration rate into a substrate is 0.118[.mu.m].u.m]..u.m].

  • PDF

Comparison of Heating Behavior of Various Susceptor-embedded Thermoplastic Polyurethane Adhesive Films via Induction Heating (다양한 발열체가 분산된 폴리우레탄 접착 필름의 유도가열 거동 비교)

  • Kwon, Yongsung;Bae, Duckhwan;Shon, MinYoung
    • Composites Research
    • /
    • v.30 no.3
    • /
    • pp.181-187
    • /
    • 2017
  • The effect of nanoscopic and microscopic Fe, $Fe_3O_4$, and Ni particles and their shapes and substrate materials on the heating behavior of thermoplastic polyurethane (TPU) adhesive films was investigated via induction heating. The heat generation tendency of $Fe_3O_4$ particles was higher than that shown by Fe and Ni particles in the TPU adhesive films. When the Fe and Ni particle size was larger than the penetration skin depth, the initial heating rate and maximum temperature increased with an increase in the particle size. This is attributed to the eddy current heat loss. The heating behavior of the TPU films with Ni particles of different shapes was examined, and different hysteresis heat losses were observed depending on the particle shape. Consequently, the flake-shaped Ni particles showed the most favorable heat generation because of the largest hysteresis loss. The substrate materials also affected the heating behavior of the TPU adhesive films in an induction heating system, and the thermal conductivity of the substrate materials was determined to be the main factor affecting the heating behavior.