• Title/Summary/Keyword: materials flow

Search Result 3,928, Processing Time 0.036 seconds

Functional MRI of Visual cortex in the Patients with Occipital Lobe Ischemia (후두엽의 허혈성 뇌졸중 환자에서 시각피질의 기능적 자기공명영상)

  • 이영준;정태섭;윤영수;한승한;조영재;배준호
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.173-178
    • /
    • 1999
  • Purpose : To evaluate the usefulness of functional MRI (fMRI) of visual cortex in patients with ischemic infarction in the occipital lobe. Materials and Methods : Four patients with the symptoms and signs of visual cortical ischemia were included. Functional MRI was performed by 2D-FLASH technique with the parameter of 90/56msec TR/TE, $40^{\circ}$ flip angle, $240{\times}240{\;}FOV,{\;}64{\times}128$ matrix number, 8.32 seconds acquisition time, 8mm slice thickness. An axial slice including both visual cortices was selected and alternative activation and resting of the visual cortex was performed using red color photostimulator. all patients undertook visual field test, and vascular abnormality was examined by MRA (n=4) and DSA (n=2). fMRI results were compared with the results of a visual field test, conventional MRI and cerebral angiography. Results : On fMRI, decreased activity of the visual cortex was found in the occipital lobe corresponding to stenosis of the posterior cerebral artery or its branch noted on angiogram. However, 2 of 4 patients showed no abnormal findings on conventional MRI. Visual field defect was noted in 3 patients, one and of whom showed no abnormality on conventional MRI and diffusion-weighted image, but revealed decreased activity in the corresponding visual cortex on fMRI. Conclusion : fMRI may be a sensitive method for detection of the status of decreased blood flow or vascular reserve which other methods can not.

  • PDF

Synthesis of d- and l-Form of $^{99m}Tc$-HMPAO, and Comparison of Brain Uptake ($^{99m}Tc$-HMPAO의 광학이성체 d-, l-Form의 합성과 뇌섭취율 비교)

  • Kang, Chan-Soon;Chang, Young-Soo;Jeong, Jae-Min;Lee, Dong-Soo;Chung, June-Key;Lee, Kang-Choon;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.69-74
    • /
    • 2001
  • Purpose: $^{99m}Tc$-HMPAO is a radiopharmaceutical for imaging cerebral blood flow. HMPAO (RR, SS)-4.8-diaza-3,6,6,9-tetramethylundecan-2,10- dione bisoxime) has three stereoismers such as, meso-. d-, and l-HMPAO. Techentium complexes of meso-HMPAO and d,l-HMPAO are known to have different in vivo brain uptakes. In this study, enantiomers of HMPAO (d-HMPAO and l-HMPAO) were separated from d,l-HMPAO. These enantiomers were labeled with $^{99m}Tc$ and the biodistribution studies were performed in mice. Materials and Methods: An intermediate imine product was produced from 2,3-butanedione monooxime and 2,2-dimethyl-1,3-propanediamine (54% yield) and was reduced into a mixture of three isomers (35% yield). The meso-isomer was separated from d,l-mixture by repeated fractional crystallization (11 % yield). The d- and l-enantiomers were subsequently separated by co-crystallization with optical isomers of tartaric acid (25% and 5% yield. respectively). Each enantiomeric HMPAO was labeled with $^{99m}Tc$ by reacting with $SnCI_2{\cdot}2H_2O\;and\;^{99m}Tc$-pertechnetate. Biodistribution study was performed 1 hr after tail vein injection to ICR mice. Results: Radiochemical purities of each compound were over 80%. In biodistribution study. the brain uptakes of d,l- d- and l-form were 1.34, 1.12 and 1.67% ID/g, respectively. In case of l-lsomer the brain uptake was higher (1.5 fold) than d-isomer. Conclusion: We successfully purified each enantiomeric HMPAO. In biodistribution study of stereoismers of $^{99m}Tc$-HMPAO in mice, l-HMPAO may show better brain image than d,l-HMPAO which was supplied in a commercial kit.

  • PDF

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF

Physical Environment Changes in the Keum River Estuary by the Dyke Gate Operation: II. Salinity Structure and Estuary Type (하구언 수문작동으로 인한 금강 하구역의 물리적 환경변화: II. 염분구조와 하구유형)

  • Lee, Sang-Ho;Kwon, Hyo-Keun;Choi, Hyun-Yong;Yang, Jae-Sam;Choi, Jin-Yong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.4
    • /
    • pp.255-265
    • /
    • 1999
  • CTD castings and current observations are taken in June, July and October, 1997 and May and July, 1998 to investigate the effect of the Keum River dyke on the structure of physical properties and the type of the Keum River estuary. Tide and tidal current relation shows that the ebbing is longer than the flooding by 1.5 hours with the early current reversing before high tide. In the rainy season (May to July), frequent large fresh water discharge during the ebbing from the dyke changes vertical salinity difference and time variation of salinity greatly near the head of the estuary, where salinity becomes lower than 2‰ in summer fresh water flooding. Halocline developed by the fresh water discharge makes two-layer structure, of which strength and depth increase in the low tide. The relationship between tide phase and surface salinity variation shows the phase lag of 2.5 hours near the head of the estuary but the standing wave relation down the estuary. This phase lag implies that a low salinity water diluted by the fresh water discharge for 2-3 hours in the ebb period moves with tidal excursion. In the dry season, vertical salinity difference reduces significantly. We calculate stratification and circulation parameters using the observed salinity structure, surface current and fresh water discharge. The Keum River estuary shows a partially mixed type, changing the stratification parameter from the rainy to the dry season. Mean flows of observed tidal current at lower and upper layer are landward and seaward, which are consistent with the circulation of a partially mixed estuary. Based upon the estuary type and circulation we suggest that the suspended materials will move toward the upstream due to low-layer mean flow and then the Keum River estuary will be a deposit environment.

  • PDF

Crossed Cerebellar and Cerebral Cortical Diaschisis in Basal Ganglia Hemorrhage (기저핵 출혈에 의한 교차 소뇌 해리 현상)

  • Lim, Joon-Seok;Ryu, Young-Hoon;Kim, Hee-Joung;Lee, Byung-Hee;Kim, Byung-Moon;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.397-402
    • /
    • 1998
  • Purpose: The purpose of this study was to evaluate the phenomenon of diaschisis in the cerebellum and cerebral cortex in patients with pure basal ganglia hemorrhage using cerebral blood flow SPECT. Materials and Methods: Twelve patients with pure basal ganglia hemorrhage were studied with Tc-99m ECD brain SPECT. Asymmetric index (AI) was calculated in the cerebellum and cerebral cortical regions as |$C_R-C_L$/$(C_R-C_L){\times}200$, where $C_R$and $C_L$ are the mean reconstructed counts for the right and left ROIs, respectively. Hypoperfusion was considered to be present when AI was greater than mean +2 SD of 20 control subjects. Results: Mean AI of the cerebellum and cerebral cortical regions in patients with pure basal ganglia hemorrhage was significantly higher than normal controls (p<0.05): Cerebellum ($18.68{\pm}8.94$ vs $4.35{\pm}0.94$, $mean{\pm}SD$), thalamus ($31.91{\pm}10.61$ vs $2.57{\pm}1.45$), basal ganglia ($35.94{\pm}16.15$ vs $4.34{\pm}2.08$), parietal ($18.94{\pm}10.69$ vs $3.24{\pm}0.87$), frontal ($13.60{\pm}10.5$ vs $4.02{\pm}2.04$) and temporal cortex ($15.92{\pm}11.95$ vs $5.13{\pm}1.69$). Ten of the 12 patients had significant hypoperfusion in the contralateral cerebellum. Hypoperfusion was also shown in the ipsilateral thalamus (n=12), ipsilateral parietal (n=12), frontal (n=6) and temporal cortex (n=10). Conclusion: Crossed cerebellar diaschisis (CCD) and cortical diaschisis may frequently occur in patients with pure basal ganglia hemorrhage, suggesting that CCD can develop without the interruption of corticopontocerebellar pathway.

  • PDF

Petrochemical study on the Daejeon-sa basalt in the Mt. Juwang area, Cheongsong (청송 주왕산지역 대전사 현무암의 암석화학적 연구)

  • 윤성효;이문원;고정선;김영라;안지영
    • The Journal of the Petrological Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.84-98
    • /
    • 2000
  • Daejeon-sa basalt in the Mt. Juwang area composed of 12 basalt flows alternate with 9 peperites and each basalt and peperite has the variety of thickness. Peperites yielded in Daejeon-sa basalt are mixed of basalt with reddish shale, of which textural type is globular peperite. Basalts yielded in Daejeon-sa basalt are massive basalt without vesicule, although sometimes vesicules are founded in upper within a flow unit. The basalt has mainly pseudomorph of olivine as phenocryst, and also plagioclase and clinopyroxene phenocryst. Matrix is mainly subophitic texture. The plotting result on the TAS diagram shows these basalts belong to the sub-alkaline, and it can be subdivided into calc-alkaline series on the basis of the diagram of Si02 vs. K20 and of alkali index vs. A1203 diagram. According to plots of wt.% oxides vs. wt.% MgO, abundances of A1203 and CaO increase with decreasing MgO while F ~ dOecre~ase . With decreasing MgO compatible elements decrease while incompatible elements increase. In spider diagram of MORB-normalized trace element patterns, HFS elements are nearly similiar with MORB, but LIL elements are enriched. Especially, contents of Ce, F: and Sm are enriched but Nb is depleted. In the chondrite-normalized REE patterns light REEs are enriched than heavy REEs. Tectomagmatic discrimination diagrams shows basalts in the study area are formed in the tectonomagmatic environment of subduction zone under continental margin. This result accord with characters of chemical composition mentioned above. Cr vs. Y diagram and CeM, vs. Ce diagram show that the primary magma of the basalts may formed by the about 15% partial melting of garnet-peridotite in the mantle wedge. After then, Daejeon-sa basalts may formed from evolved magma undergone mainly olivine fractional crystallization and contarnination of crustal materials before eruption.

  • PDF

The Application of Operations Research to Librarianship : Some Research Directions (운영연구(OR)의 도서관응용 -그 몇가지 잠재적응용분야에 대하여-)

  • Choi Sung Jin
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.4
    • /
    • pp.43-71
    • /
    • 1975
  • Operations research has developed rapidly since its origins in World War II. Practitioners of O. R. have contributed to almost every aspect of government and business. More recently, a number of operations researchers have turned their attention to library and information systems, and the author believes that significant research has resulted. It is the purpose of this essay to introduce the library audience to some of these accomplishments, to present some of the author's hypotheses on the subject of library management to which he belives O. R. has great potential, and to suggest some future research directions. Some problem areas in librianship where O. R. may play a part have been discussed and are summarized below. (1) Library location. It is usually necessary to make balance between accessibility and cost In location problems. Many mathematical methods are available for identifying the optimal locations once the balance between these two criteria has been decided. The major difficulties lie in relating cost to size and in taking future change into account when discriminating possible solutions. (2) Planning new facilities. Standard approaches to using mathematical models for simple investment decisions are well established. If the problem is one of choosing the most economical way of achieving a certain objective, one may compare th althenatives by using one of the discounted cash flow techniques. In other situations it may be necessary to use of cost-benefit approach. (3) Allocating library resources. In order to allocate the resources to best advantage the librarian needs to know how the effectiveness of the services he offers depends on the way he puts his resources. The O. R. approach to the problems is to construct a model representing effectiveness as a mathematical function of levels of different inputs(e.g., numbers of people in different jobs, acquisitions of different types, physical resources). (4) Long term planning. Resource allocation problems are generally concerned with up to one and a half years ahead. The longer term certainly offers both greater freedom of action and greater uncertainty. Thus it is difficult to generalize about long term planning problems. In other fields, however, O. R. has made a significant contribution to long range planning and it is likely to have one to make in librarianship as well. (5) Public relations. It is generally accepted that actual and potential users are too ignorant both of the range of library services provided and of how to make use of them. How should services be brought to the attention of potential users? The answer seems to lie in obtaining empirical evidence by controlled experiments in which a group of libraries participated. (6) Acquisition policy. In comparing alternative policies for acquisition of materials one needs to know the implications of each service which depends on the stock. Second is the relative importance to be ascribed to each service for each class of user. By reducing the level of the first, formal models will allow the librarian to concentrate his attention upon the value judgements which will be necessary for the second. (7) Loan policy. The approach to choosing between loan policies is much the same as the previous approach. (8) Manpower planning. For large library systems one should consider constructing models which will permit the skills necessary in the future with predictions of the skills that will be available, so as to allow informed decisions. (9) Management information system for libraries. A great deal of data can be available in libraries as a by-product of all recording activities. It is particularly tempting when procedures are computerized to make summary statistics available as a management information system. The values of information to particular decisions that may have to be taken future is best assessed in terms of a model of the relevant problem. (10) Management gaming. One of the most common uses of a management game is as a means of developing staff's to take decisions. The value of such exercises depends upon the validity of the computerized model. If the model were sufficiently simple to take the form of a mathematical equation, decision-makers would probably able to learn adequately from a graph. More complex situations require simulation models. (11) Diagnostics tools. Libraries are sufficiently complex systems that it would be useful to have available simple means of telling whether performance could be regarded as satisfactory which, if it could not, would also provide pointers to what was wrong. (12) Data banks. It would appear to be worth considering establishing a bank for certain types of data. It certain items on questionnaires were to take a standard form, a greater pool of data would de available for various analysis. (13) Effectiveness measures. The meaning of a library performance measure is not readily interpreted. Each measure must itself be assessed in relation to the corresponding measures for earlier periods of time and a standard measure that may be a corresponding measure in another library, the 'norm', the 'best practice', or user expectations.

  • PDF

A Study on the Frequency of Occurrence of the Aortic Dissection using CT (CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰)

  • Dong, Kyung-Rae;Choi, Sung-Kwan;Jang, Young-Ill;Ro, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • Purpose: Aortic Dissection is very dangerous, prognostic disease, which the bloodstream flow out of the true lumen of the aorta by the bursting of aortic intima resulting in a rapid dissociation of inner and outer layer from the media. It is difficult to diagnose aortic dissection clinically by normal X-ray. This study was to investigate the occurrence frequency by age and number of patients who are identified to be aortic dissection by CT (Computed Tomography) scan. Materials and methods: We investigated the trend of yearly fluctuation, gender, age, and department of clinical research of the 112 patients who conducted CT scan in C- University Hospital for two years from January 2005 to December 2006. The MIP and SSD which reconstructed CT image and the VRT image were obtained for the accurate observation. The result was investigated by comparing normal X-ray and CT scan. Results and Conclusion: 1. The yearly check of 112 patients conducted CT scan showed 37 people (41.9%) in 2005, and it was increased to 65 (58.1%) in 2006 by 1.4 times. 2. The gender distribution of patients given a CT scan showed 45 males (40.1%), and female 67 (59.9 %). The aortic dissection patients were 9 (20%) out of 45 males, 21 (31.3%) out of 67 females and women were 1.6 times more than men. Women are also 1.5 times more than men in the number of examinee. 3. The age distribution of patient's who conducted CT scan revealed that there was no patient under 30 years old while 88.3% of all patients were through 41 to 80 years old. The higher the age was, the higher the occurrence of aortic dissection was. The difference in the occurrence frequency of age was statistically significant (p<0.01). 4. The departments that requested CT scan were the emergency department 46 (41.1%), circulatory internal medicine 37 (33.0%), chest surgery 13 (11.6%), and others 6 (14.3%). The combined ratio of emergency medicine and circulatory internal medicine was 74.1% of all. The results show that the aortic dissection is a very dangerous disease whose patients visit mainly via the emergency room. 5. The aortic dissection patients had normal X-ray readings in 22 (73.3%) out of 30, and only 8 (26.7 percent) are abnormal in the X-ray diagnosis. Therefore, the CT scan needs to be enforced in order to assess accurately the disease of aortic dissection.

  • PDF

Functional MRI of Visual Cortex: Correlation between Photic Stimulator Size and Cortex Activation (시각피질의 기능적 MR 연구: 광자극 크기와 피질 활성화와의 관계)

  • 김경숙;이호규;최충곤;서대철
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.114-118
    • /
    • 1997
  • Purpose: Functional MR imaging is the method of demonstrating changes in regional cerebral blood flow produced by sensory, motor, and any other tasks. Functional MR of visual cortex is performed as a patient stares a photic stimulation, so adaptable photic stimulation is necessary. The purpose of this study is to evaluate whether the size of photic stimulator can affect the degree of visual cortex activation. Materials and Methods: Functional MR imaging was performed in 5 volunteers with normal visual acuity. Photic stimulator was made by 39 light-emitting diodes on a plate, operating at 8Hz. The sizes of photic stimulator were full field, half field and focal central field. The MR imager was Siemens 1.5-T Magnetom Vision system, using standard head coil. Functional MRI utilized EPI sequence (TR/TE= 1.0/51. Omsec, matrix $No.=98{\times}128$, slice thickness=8mm) with 3sets of 6 imaging during stimulation and 6 imaging during rest, all 36 scannings were obtained. Activation images were obtained using postprocessing software(statistical analysis by Z-score), and these images were combined with T-1 weighted anatomical images. The activated signals were quantified by numbering the activated pixels, and activation a index was obtained by dividing the pixel number of each stimulator size with the sum of the pixel number of 3 study using 3 kinds of stimulators. The correlation between the activation index and the stimulator size was analysed. Results: Mean increase of signal intensities on the activation area using full field photic stimulator was about 9.6%. The activation index was greatest on full field, second on half field and smallest on focal central field in 4. The index of half field was greater than that of full field in 1. The ranges of activation index were full field 43-73%(mean 55%), half field 22-40 %(mean 32%), and focal central field 5-24%(mean 13%). Conclusion: The degree of visual cortex activation increases with the size of photic stimulator.

  • PDF

Optical Properties of SiNx Thin Films Grown by PECVD at 200℃ (200℃의 저온에서 PECVD 기법으로 성장한 SiNx 박막의 열처리에 따른 광학적 특성 변화 규명)

  • Lee, Kyung-Su;Kim, Eun-Kyeom;Son, Dae-Ho;Kim, Jeong-Ho;Yim, Tae-Kyung;An, Seung-Man;Park, Kyoung-Wan
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.1
    • /
    • pp.42-49
    • /
    • 2011
  • We deposited $SiN_x$ thin films by using PECVD technique at $200^{\circ}C$ with various flow ratios of the $SiH_4/N_2$ gases. The photoluminescence measurements revealed that the maximum emission wavelength shifted to long wavelength as the ratio increased, however, positions of the several peak wavelengths, such as 1.9, 2.2, 2.4, and 3.1 eV, were independent on the ratio. Changes of the photoluminescence spectra were measured in the $N_{2}-$, $H_{2}-$, and $O_2$-annealed films. The luminescence intensities increased after the annealing process. In particular, the maximum emission wavelength shifted to short wavelength after $H_{2}-$ or $O_2$-annealing. But there were still several peaks on the spectra of all annealed films, several peak positions remained to be unchanged after the annealing. As for the light emission mechanism, we have considered the defect states of the Si- and N- dangling bonds in the $SiN_x$ energy gap, so that the energy transitions from/to the conduction/valence bands and the defect states in the gap were attributed to the light emission in the $SiN_x$ films. The experimental results point to the possibility of a Si-based light emission materials for flexible Si-based electro-optic devices.