• Title/Summary/Keyword: material-independent

Search Result 744, Processing Time 0.024 seconds

Study on 6 MV Photon beam Dosimetry by Asymmetric Collimator Variation of Linear Accelerator (6MV 선형가속기의 비대칭 조사야의 변화에 따른 선량분포)

  • Yoon, Joo-Ho;Lee, Chul-Soo;Yum, Ha-Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.12 no.1
    • /
    • pp.91-104
    • /
    • 2000
  • Recently linear accelerator in radiation therapy in asymmetric field has been easily used since the improvement and capability of asymmetrical field adjustment attached to the machine. It has been thought there have been some significant errors in dose calculation when asymmetrical radiation fields have been utilized in practice of radiation treatments if the fundamental data for dose calculation have been measured in symmetrical standard fields. This study investigated how much the measured data of dose distributions and their isodose curves are different between in asymmetrical and symmetrical standard fields, and how much there difference affect the error in dose calculation in conventional method measured in symmetrical standard field. The distributions of radiation dose were measured by photon diode detector in the water phantom (RFA-300P, Scanditronix, Sweden) as tissue equivalent material on utilization of 6 MV linear accelerator with source surface distance (SSD) 1000 mm. The photon diode detector has the velocity of 1 mm per second from water surface to 250 mm depth in the field size of $40mm{\times}40mm\;to\;250mm{\times}250mm\;symmetric\;field\;and\;40mm{\times}20mm\;to\;250mm{\times}125mm$ asymmetrical fields. The measurements of percent depth dose (PDD) and subsequent plotting of their isodose curves were performed from water surface to 250mm dmm from Y-center axis in $100mm{\times}50mm$ field in order to absence the variability of depth dose according to increasing field sizes and their affects to plotted isodose curves. The difference of PDD between symmetric and asymmetric field was maximum $4.1\%\;decrease\;in\;40mm{\times}20mm\;field,\;maximum\;6.6\%\;decrease\;in\;100mm{\times}50mm\;and\;maximum\;10.2\%\;decrease\;200mm{\times}100mm$, the larger decrease difference of PDD as the greater field size and as greater the depth, The difference of PDD between asymmetrical field and equivalent square field showed maximum $2.4\%\;decrease\;in\;60mm{\times}30mm\;field,\;maximum\;4.8\%\;decrease\;in\;150mm{\times}75mm\;and\;maximum\;6.1\%\;decrease\;in\;250mm{\times}125mm$, and the larger decreased differenced PDD as the greater field size and as greater the depth, these differences of PDD were out of $5\%$ of dose calculation as defined by international Commission on radiation unit and Measurements(ICRU). In the dose distribution of asymmetrical field (half beam) the plotted isodose curves were observed to have deviations by decreased PDD as greater as the blocking of the beam moved closer to the central axis, and as the asymmetrical field increased by moving the block 10 mm keeping away from the central axis, the PDD increased and plotted isodose curves were gradually more flattened, due to reduced amount of the primary beam and the fraction of low energy soft radiations by passing thougepth in asymmetrical field by moving independent jaw each 10 h beam flattening filter. As asymmetrical radiation field as half beam radiation technique is used, the radiation dosimetry calculated in utilizing the fundamental data which measured in standard symmetrical field should be converted on bases of nearly measured data in asymmetrical field, measured beam data flies of various asymmetrical field in various energy and be necessary in each institution.

  • PDF

Clinical Analysis of Contralateral Bulla of Lung on HRCT in the Patients Having Video-Assisted Thoracoscopic Surgery for Unilateral Primary Spontaneous Pneumothorax (자연 기흉 수술 환자에서 반대편 폐기포에 대한 임상적 고찰)

  • Shin, Dong-Il;Oh, Tae-Yoon;Chang, Woon-Ha;Kim, Jung-Tae;Jeong, Young-Kyun
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.687-693
    • /
    • 2010
  • Background: It is controversial whether the presence of bullae on the contralateral lung on HRCT plays a role in occurrence of contralateral primary spontaneous pneumothorax. We analyzed the significance of bullae on the contralateral lung and the risk factors associated with contralateral occurrence of primary spontaneous pneumothorax. Material and Method: Three hundred ninety four patients who were undergone Video-Assisted Thoracoscopic Surgery for primary spontaneous pneumothorax between January 2004 and December 2009 were reviewed. The clinical features, HRCT and treatment of these patients were analyzed retrospectively. Result: Twenty eight of 394 patients had contralateral occurrence (7.10%). The average time was $13.06{\pm}9.79$ months. A presence of contralateral bullae of lung on HRCT may not seem to be significant for occurrence of contralateral primary spontaneous pneumothorax (p=0.059). But bullae numbers were much more in contralateral pneumothorax patients (p=0.011). Younger than 20, being underweight (Body Mass Index < $18.5 kg/m^2$) are independent risk factors for contralateral occurrence (odds ratio, 5.075 (1.679~5.339), 2.366 (1.048~5.339) respectively). Conclusion: The presence of bullae on the contralateral lung on HRCT was not significantly influenced the occurrence of contralateral primary spontaneous pneumothorax. However, age, body mass index, and the number of bullae were significant factors for the contralateral pneumothorax. We suggest that those high risk patients may require special attentions and general supportive care to prevent occurrence of contralateral primary spontaneous pneumothorax during the follow-up.

A Study on Dosimetry for Small Fields of Photon Beam (광자선 소조사면의 선량 측정에 관한 연구)

  • 강위생;하성환;박찬일
    • Progress in Medical Physics
    • /
    • v.5 no.2
    • /
    • pp.57-68
    • /
    • 1994
  • Purpose : The purposes are to discuss the reason to measure dose distributions of circular small fields for stereotactic radiosurgery based on medical linear accelerator, finding of beam axis, and considering points on dosimetry using home-made small water phantom, and to report dosimetric results of 10MV X-ray of Clinac-18, like as TMR, OAR and field size factor required for treatment planning. Method and material : Dose-response linearity and dose-rate dependence of a p-type silicon (Si) diode, of which size and sensitivity are proper for small field dosimetry, are determined by means of measurement. Two water tanks being same in shape and size, with internal dimension, 30${\times}$30${\times}$30cm$^3$ were home-made with acrylic plates and connected by a hose. One of them a used as a water phantom and the other as a device to control depth of the Si detector in the phantom. Two orthogonal dose profiles at a specified depth were used to determine beam axis. TMR's of 4 circular cones, 10, 20, 30 and 40mm at 100cm SAD were measured, and OAR's of them were measured at 4 depths, d$\sub$max/, 6, 10, 15cm at 100cm SCD. Field size factor (FSF) defined by the ratio of D$\sub$max/ of a given cone at SAD to MU were also measured. Result : The dose-response linearity of the Si detector was almost perfect. Its sensitivity decreased with increasing dose rate but stable for high dose rate like as 100MU/min and higher even though dose out of field could be a little bit overestimated because of low dose rate. Method determining beam axis by two orthogonal profiles was simple and gave 0.05mm accuracy. Adjustment of depth of the detector in a water phantom by insertion and remove of some acryl pates under an auxiliary water tank was also simple and accurate. TMR, OAR and FSF measured by Si detector were sufficiently accurate for application to treatment planning of linac-based stereotactic radiosurgery. OAR in field was nearly independent of depth. Conclusion : The Si detector was appropriate for dosimetry of small circular fields for linac-based stereotactic radiosurgery. The beam axis could be determined by two orthogonal dose profiles. The adjustment of depth of the detector in water was possible by addition or removal of some acryl plates under the auxiliary water tank and simple. TMR, OAR and FSF were accurate enough to apply to stereotactic radiosurgery planning. OAR data at one depth are sufficient for radiosurgery planning.

  • PDF

Value of Bone Scan in Addition to F-18 FDG PET/CT and Characteristics of Discordant lesions between F-18 FDG PET/CT and Bone Scan in the Spinal Bony Metastasis (척추골전이에 있어 F-18 FDG PET/CT에 대한 골스캔의 추가적 역할 및 F-18 FDG PET/CT와 골스캔간에 불일치 병소에 대한 연구)

  • Jun, Sung-Min;Nam, Hyun-Yeol;Kim, In-Ju;Kim, Yong-Ki;Kim, Ju-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.218-228
    • /
    • 2008
  • Purpose: Our purpose was to evaluate spinal bony metastasis which could be missed on an F-18 FDG PET/CT (FDG PET/CT) alone, and to characterize discordant metastatic lesions between FDG PET/CT and bone scan. Material and Methods: FDG PET/CT and bone scans of 43 patients with spinal bony metastasis were analyzed retrospectively. A McNemar test was performed comparing the FDG PET/CT alone to the FDG PET/CT plus bone scan in the spinal bony metastases. A one-way chi-square test was performed to characterize the metastases that were missed on the FDG PET/CT alone. To evaluate discordant lesions between FDG PET/CT and bone scan, we performed logistic regression analyses. The independent variables were sites (cervical, thoracic, and lumbar), size (large and small), and maximum SUVs, and the dependant variable was bone scan uptake (positive and negative MDP uptake). Results: A significant difference was found between the FDG PET/CT alone and the FDG PET/CT combined with the bone scan (p < 0.01). Using the FDG PET/CT only, diffuse osteoblastic metastasis was missed with a significantly higher frequency (p = 0.04). In the univariate analysis, cervical vertebra and small size were related to negative MDP uptake, and thoracic vertebra and large size were related to positive MDP uptake. However, in the multivariate analysis, only the large size was related to positive MDP uptake. Conclusion: A bone scan in addition to the FDG PET/CT increased the ability to evaluate spinal bony metastases, especially for diffuse osteoblastic metastasis. Large metastasis was related to positive bone scan uptake in spinal bony metastasis.

A Study on the Direction of Private Investigation System - Focus on the bill proposal in 2012·2013 (민간조사제도의 도입 방향에 관한 연구 - 제19대 국회 발의 법안을 중심으로(2012년·2013년))

  • Cho, Min-Sang;Oh, Youn-Sung
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.525-559
    • /
    • 2013
  • Modern society has been exposed to various dangers and crimes in the process of globalization, informationization, decentralization etc. along with the development of material civilization under rapid changing societal environment. These factors are exerting a lot of effects in public security environments, as result there are gradual interest about crime and crime prevention. Realization of responsibility who take charge of social safety, from public security to private security, appears important topic at the moment. The positive point of view which private security industry is responsible to cope with security spheres instead of public security has been emerged from the reason that the public security has limitation to solve security problems for themselves. It is the time to make effort to compromise the public security and the private security industry to forecast social change and prevent dangers in the advance. In Korea, there has been close cooperation between public security and private security for decades. Strongly emerging and interesting sphere is "Private Investigation(Private Detective)" in Korea at present. There has been some proposed legislations of private investigation for decreasing burden of public security and social sympathy about possibility of private investigation system is increasing now. In this study, we focused on the introduction of private investigation system through the analysis of bill proposals for last 14 years, for instance historical aspects, contents, the differences among bill proposals. Among these, a comparison on bill proposals of the 19th National Assembly's during 2012 - 2013 were analysed mainly. We examined the importance point at issue items for introduction of private investigation system. Suggestions for introduction of private investigation system is as follows. The necessity of independent bill for developmental private investigation system is needed and the main body should be a juristic person instead of a individual for the public interest and responsibility. For the good service of private investigation and to prevent the unqualified person become a private investigator, the recruiting system and examination of private investigator should be prepared well and take into consideration anticipated problems. Also the necessity of definite jurisdiction department's appointment to divide responsibility in operation.

  • PDF

Effect of Preoperative White Blood Cell Count on Postoperative Course in Patients with Coronary Artery Bypass Grafting (관상동맥우회술 환자에서 술 전 백혈구 수치가 수술 후 경과에 미치는 영향)

  • Son Kuk Hui;Kim Jae Ho;Kim Joung Taek;Yoon Yong Han;Kim Kwang Ho;Baek Wan Ki
    • Journal of Chest Surgery
    • /
    • v.38 no.10 s.255
    • /
    • pp.669-674
    • /
    • 2005
  • Background: There are several studies that report the relationship between leukocytosis and cardiovascular disease mortality. Most of these studies stand on the basis that atherosclerosis is mediated by inflammatory process. By the same token, preoperative white blood cell count is suggested as an independent predictable factor of postoperative mortality and morbidity in coronary artery bypass grafting. The purpose of this study is to define the influence of preoperative white blood cell count on postoperative morbidity and mortality after coronary artery bypass grafting. Material and Method: The medical records of the 133 patients who had undergone isolated coronary artery bypass grafting at Inha University Hospital from 1996 to 2003 were reviewed. Patients were evenly divided into four groups, and named as group A, B, C, and D respectively based on their preoperative white blood cell count in ascending order. The number of patients in each group were 33 with exception of 34 in group A. The range of white blood cell count were from $1.3\times10^3/{\mu}L\;to\;5.9\times10^3/{\mu}L\;in\;group\;A,\; from\;6.0\times10^3/{\mu}L\;to\;7.0\times10^3/{\mu}L\;in\;group\;B,\;from\;7.1\times10^3/{\mu}L\;to\;8.9\times10^3/{\mu}L$ in group C, and from $8.9\times10^3/{\mu}L\;to\;16.9\times10^3/{\mu}L$ in group D. Result: The number of patients with recent myocardial infarction was 0 in group A, $2(6.1\%)$ in group B, $4(12.1\%)$ in group C, and $8(24.3\%)$ in D group, showing proportional increase to the white blood cell count (p<0.01). There were six postoperative deaths; $1(2.9\%)$ in group A, $1(3.0\%)$ in group B, $2(2.6\%)$ in group C, and $2(6.1\%)$ in group D (p=0.44), showing no significant difference between the groups. Postoperative wound infection occurred in 3 patients; all 3 patients were in group D, showing that postoperative wound infection is closely related to the preoperative white blood cell count. Conclusion: The association between preoperative white blood cell count and postoperative mortality could not be defined. The incidence of postoperative wound infection was found to be proportional to the preoperative white blood cell counts.

Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images (CT 영상 및 몬테칼로 계산에 기반한 근접 방사선치료계획의 선량분포 평가 방법 연구)

  • Cheong, Kwang-Ho;Lee, Me-Yeon;Kang, Sei-Kwon;Bae, Hoon-Sik;Park, So-Ah;Kim, Kyoung-Joo;Hwang, Tae-Jin;Oh, Do-Hoon
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.253-260
    • /
    • 2010
  • Most brachytherapy treatment planning systems employ a dosimetry formalism based on the AAPM TG-43 report which does not appropriately consider tissue heterogeneity. In this study we aimed to set up a simple Monte Carlo-based intracavitary high-dose-rate brachytherapy (IC-HDRB) plan verification platform, focusing particularly on the robustness of the direct Monte Carlo dose calculation using material and density information derived from CT images. CT images of slab phantoms and a uterine cervical cancer patient were used for brachytherapy plans based on the Plato (Nucletron, Netherlands) brachytherapy planning system. Monte Carlo simulations were implemented using the parameters from the Plato system and compared with the EBT film dosimetry and conventional dose computations. EGSnrc based DOSXYZnrc code was used for Monte Carlo simulations. Each $^{192}Ir$ source of the afterloader was approximately modeled as a parallel-piped shape inside the converted CT data set whose voxel size was $2{\times}2{\times}2\;mm^3$. Bracytherapy dose calculations based on the TG-43 showed good agreement with the Monte Carlo results in a homogeneous media whose density was close to water, but there were significant errors in high-density materials. For a patient case, A and B point dose differences were less than 3%, while the mean dose discrepancy was as much as 5%. Conventional dose computation methods might underdose the targets by not accounting for the effects of high-density materials. The proposed platform was shown to be feasible and to have good dose calculation accuracy. One should be careful when confirming the plan using a conventional brachytherapy dose computation method, and moreover, an independent dose verification system as developed in this study might be helpful.

Approach to improve construction management using Information Technology (IT) (정보기술(IT) 기반을 통한 시공관리 선진화 방안)

  • Lee Woo-Bang;Moon Jin-Yeong;Moon Byeong-Suk
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.115-122
    • /
    • 2002
  • There is various points that should be improved in Fairness such as our contract practice to propose construction projects, project managing and the stakeholders' way of thinking and culture. We consider that the revision of construction related provisions and systems is required but even more, an overall change in business management through the implementation of Integrated Construction Information Management System that will enable the owner, which drives the project, and contractor sharing construction information is required. To mange construction related information in an integrated manner, designing information should be smoothly transferred to purchasing information, and changes are required in order to move ahead to process-oriented work system. Finally information created from various construction organizations should be delivered in an aligned and standardized manner as well. The domestic Nuclear Power Plant Construction has been accepting various technology transfers from U.S, France, Canada and UK, which enabled us to self-support technology and recently even proceeded to the phase exporting our technology to others. However, continuous effort is required to improve internal business efficiency and to respond to external environmental change such aselectricity market deregulation. Recently, in accordance with the result in number of CEO's intention to make progress in IT and improve business efficiency, the number of enterprises introducing Enterprise Resource Planning is increasing. ERP is an innovative tool which changes the way of performing work from organization and department orientation to process-orientation in order to optimize the resources, such as human and material resources, through out the Enterprise by performing BPR which will maximize overall business efficiency of the enterprise, such includes not only construction management, but also business management. KHNP continued to performing large scaled construction projects such as nuclear power plant construction for past 30 years and took the initiatives of large scale project management and Quality management ability in domestic industry by having independent capability of over all construction planning, purchasing and, construction and start up management etc. To maintain our leading position of improving construction management technology based on our accumulated project management experience and technology, KHNP included construction into our ERP project in purpose of innovating construction business. We would like to discuss the characteristics of nuclear construction business, project management system, information system infrastructure and information sharing system among construction related entities, and implementation practices for information system, and consider how to resolve our practice that should be improved in this thesis.

  • PDF

Verification of Skin Dose in Tomotherapy Using the Developed Phantom for Image Based Radiation Treatment System (영상 기반 치료 장비용 팬톰을 이용한 토모테라피 피부 선량 검증)

  • Park, Ji-Yeon;Chang, Ji-Na;Oh, Seung-Jong;Kang, Dae-Gyu;Jung, Won-Gyun;Lee, Jeong-Woo;Jang, Hong-Suk;Kim, Hoi-Nam;Park, Hae-Jin;Kim, Sung-Hwan;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.88-96
    • /
    • 2009
  • Radiation treatment for skin cancer has recently increased in tomotherapy. It was reported that required dose could be delivered with homogeneous dose distribution to the target without field matching using electron and photon beam. Therapeutic beam of tomotherapy, however, has several different physical characteristic and irradiation of helical beam is involved in the mechanically dynamic factors. Thus verification of skin dose is requisite using independent tools with additional verification method. Modified phantom for dose measurement was developed and skin dose verification was performed using inserted thermoluminescent dosimeters (TLDs) and GafChromic EBT films. As the homogeneous dose was delivered to the region including surface and 6 mm depth, measured dose using films showed about average 2% lower dose than calculated one in treatment planning system. Region indicating about 14% higher and lower absorbed dose was verified on measured dose distribution. Uniformity of dose distribution on films decreased as compared with that of calculated results. Dose variation affected by inhomogeneous material, Teflon, little showed. In regard to the measured dose and its distribution in tomotherapy, verification of skin dose through measurement is required before the radiation treatment for the target located at the curved surface or superficial depth.

  • PDF

Is Video-assisted Thoracoscopic Resection for Treating Apical Neurogenic Tumors Always Safe? (흉강 첨부 양성 신경종의 흉강경을 이용한 절제술: 언제나 안전하게 시행할 수 있나?)

  • Cho, Deog Gon;Jo, Min Seop;Kang, Chul Ung;Cho, Kyu Do;Choi, Si Young;Park, Jae Kil;Jo, Keon Hyeon
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.72-78
    • /
    • 2009
  • Background: Mediastinal neurogenic tumors are generally benign lesions and they are ideal candidates for performing resection via video-assisted thoracoscopic surgery (VATS). However, benign neurogenic tumors at the thoracic apex present technical problems for the surgeon because of the limited exposure of the neurovascular structures, and the optimal way to surgically access these tumors is still a matter of debate. This study aims to clarify the feasibility and safety of the VATS approach for performing surgical resection of benign apical neurogenic tumors (ANT). Material and Method: From January 1996 to September 2008, 31 patients with benign ANT (15 males/16 females, mean age: 45 years, range: 8~73), were operated on by various surgical methods: 14 VATS, 10 lateral thoracotomies, 6 cervical or cervicothoracic incisions and 1 median sternotomy. 3 patients had associated von Recklinhausen's disease. The perioperative variables and complications were retrospectively reviewed according to the surgical approaches, and the surgical results of VATS were compared with those of the other invasive surgeries. Result: In the VATS group, the histologic diagnosis was schwannoma in 9 cases, neurofibroma in 4 cases and ganglioneuroma in 1 case, and the median tumor size was 4.3 cm (range: 1.2~7.0 cm). The operation time, amount of chest tube drainage and the postoperative stay in the VATS group were significantly less than that in the other invasive surgical group (p<0.05). No conversion thoracotomy was required. There were 2 cases of Hornor's syndrome and 2 brachial plexus neuropathies in the VATS group; there was 1 case of Honor's syndrome, 1 brachial plexus neuropathy, 1 vocal cord palsy and 2 non-neurologic complications in the invasive surgical group, and all the complications developed postoperatively. The operative method was an independent predictor for postoperative neuropathies in the VATS group (that is, non-enucleation of the tumor) (p=0.029). Conclusion: The VATS approach for treating benign ANT is a less invasive, safe and feasible method. Enucleation of the tumor during the VATS procedure may be an important technique to decrease the postoperative neurological complications.