• Title/Summary/Keyword: material transport

Search Result 1,165, Processing Time 0.023 seconds

Understanding the Flow Properties by a Numerical Modeling in the South Sea of Korea (수치모델을 이용한 한국 남해의 유동특성 이해)

  • Bae, Sang-Wan;Kim, Dong-Sun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.4
    • /
    • pp.295-307
    • /
    • 2012
  • In order to understand the flow properties of the South Sea of Korea, tidal currents, wind-driven currents, density-driven currents and residual flows were investigated by using 3-dimensional numerical model(POM). In offshore regions, tide-induced residual current tends to flow eastward during the spring tide and westward during the neap tide. Total residual flow is irregular due to the bottom topography in the coastal area. The density-driven currents in the coastal area showed to be relatively weak, with little seasonal differences. The special tendency was apparent in the open sea. That is, the flow in the offshore regions showed results similar to that of the Tsushima current. The wind-driven currents in the coastal area showed to be much stronger than in offshore regions. Vertically, the flow of the surface layer was much stronger than that of the bottom layer. Through these results, material transport and diffusion in the south coast, as a basis for predicting the spread of use is expected to be available.

Preliminary Leak-before Break Assessment of Intermediate Heat Transport System Hot-Leg of a Prototype Generation IV Sodium-cooled Fast Reactor (소듐냉각고속로 원형로 중간열전달계통 고온배관의 파단전누설 예비평가)

  • Lee, Sa Yong;Kim, Nak Hyun;Koo, Gyeong Hoi;Kim, Sung Kyun;Kim, Yoon Jea
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.126-133
    • /
    • 2016
  • Recently, the research and development of Sodium-cooled Fast Reactors (SFRs) have made progresses. However, liquid sodium, the coolant of an SFR, is chemically unstable and sodium fire can be occurred when liquid sodium leaks from sodium pipe. To reduce the damage by the sodium fire, many fire walls and fire extinguishers are needed for SFRs. LBB concept in SFR might reduce the scale of sodium fire and decrease or eliminate fire walls and fire extinguishers. Therefore, LBB concept can contribute to improve economic efficiency and to strengthen defense-in depth safety. The LBB assessment procedure has been well established, and has been used significantly in light water reactors (LWRs). However, an LBB assessment of an SFR is more complicated because SFRs are operated in elevated temperature regions. In such a region, because creep damage may occur in a material, thereby growing defects, an LBB assessment of an SFR should consider elevated temperature effects. The procedure and method for this purpose are provided in RCC-MRx A16, which is a French code. In this study, LBB assessment was performed for PGSFR IHTS hot-leg pipe according to RCC-MRx A16 and the applicability of the code was discussed.

A Study on Monte Carlo Simulation by Beam Scattering in Resin of New Austria Tunnel Method for Safety of Industrial Disaster (산업재해 안전을 위한 New Austria Tunnel Method 수지에서 빔산란에 관한 Monte Carlo 시뮬레이션에 관한 연구)

  • Kim, Ki-Jun;Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.473-479
    • /
    • 2012
  • The influences of scatterer and absorber in turbid material by light scattering were interpreted for the scattered intensity and wavelength. The molecular properties have been studied by Monte Carlo simulation in resin of New Austria Tunnel Method. It has been found that the effects of optical properties in scattering media could be investigated by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Monte Carlo Simulation method for modelling of light transport in the civil engineering and construction field was applied. The results using a phantom were discussed that the distance from source to detector is closer, and scattering intensity is stronger with those obtained through Monte Carlo Simulation. It may also aid in designing the best model for coatings and corrosion for the durability of metal constructions.

Development of ACBIO: A Biosphere Template Using AMBER for a Potential Radioactive Waste Repository (AMBER를 이용한 방사성폐기물처분장 생태계 평가 템플릿 ACBIO 개발)

  • Lee Youn-Myoung;Hwang Yongsoo;Kang Chul-Hyung;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.3
    • /
    • pp.213-229
    • /
    • 2005
  • Nuclides in radioactive wastes are assumed to be transported in the geosphere by groundwater and probably discharged into the biosphere. Quantitative evaluation of doses to human beings due to nuclide transport in the geosphere and through the various pathways in the biosphere is the final step of safety assessment of the radioactive waste repository. To calculate the flux to dose conversion factors (DCFs) for nuclides appearing at GBIs with their decay chains, a template ACBIO which is an AMBER case file based on mathematical model for the mass transfer coefficients between the compartments has been developed considering material balance among the compartments in biosphere and then implementing to AMBER, a general and flexible software tool that allows to build dynamic compartment models. An illustrative calculation with ACBIO is shown.

  • PDF

Transport and Distribution of Calcium Salt in Tofu Manufacturing Process -Part I. Conductometric Measurement of Calcium Salt in Tofu and Drained Solution- (두부제조공정(製造工程)중 Calcium 염(鹽)의 행동(行動)과 분포(分布) -제1보(第一報). 전기전도도법(電氣傳導度法)에 의한 두부 및 순물의 Calcium 농도 측정방법(測定方法)-)

  • Yim, Sang-Bin;Lee, Choon-Ki;Chun, Jae-Kum
    • Applied Biological Chemistry
    • /
    • v.28 no.1
    • /
    • pp.8-12
    • /
    • 1985
  • For measuring calcium content during the manufacturing process of Tofu, conductometric electrodes were made with the copper plate, and the results were compared with chemical analysis methods. Three types of plate material (I, II, III) for electrode were tested to apply for measuring $CaCl_2$ content in solution, drained solution from Tofu and in agar-agar gel ana Tofu. Empirical linear correlation equations between conductivity (Y, mho) and calcium content (C, Mole $\bar{C}$, mg% wet basis) were obtained for the quick estimation of calcium content during Tofu processings. Equations with plate II type electrode were Y=0.6364C+0.0775 for drained solution with r=0.99, and $Y=7.1503{\times}10^{-5}\bar{C}-2.9895{\times}10^{-3}$ for Tofu with r=0.91,respectively.

  • PDF

2-Wavelength Organic Light-Emitting Diodes Using Bebq2 Selectively Doped with (pq)2Ir(acac) (Bebq2에 (pq)2Ir(acac)가 선택 도핑된 2-파장 유기발광다이오드)

  • Kim, Min-Young;Ji, Hyun-Jin;Jang, Ji-Geun
    • Korean Journal of Materials Research
    • /
    • v.21 no.4
    • /
    • pp.212-215
    • /
    • 2011
  • New organic light-emitting diodes with structure of indium-tin-oxide[ITO]/N,N'-diphenyl-N, N'-bis-[4-(phenyl-m-tolvlamino)-phenyl]-biphenyl-4,4'-diamine[DNTPD]/1,1-bis-(di-4-poly-aminophenyl) cyclohexane[TAPC]/bis(10-hydroxy-benzo(h)quinolinato)beryllium[Bebq2]/Bebq2:iridium(III)bis(2-phenylquinoline-N,C2')acetylacetonate[(pq)2Ir(acac)]/ET-137[electron transport material from SFC Co]/LiF/Al using the selective doping of 5%-(pq)2Ir(acac) in a single Bebq2 host in the two wavelength (green, orange) emitter formation were proposed and characterized. In the experiments, with a 300${\AA}$-thick undoped emitter of Bebq2, two kinds of devices with the doped emitter thicknesses of 20${\AA}$ and 40${\AA}$ in the Bebq2:(pq)2Ir(acac) were fabricated. The device with a 20${\AA}$-thick doped emitter is referred to as "D-1" and the device with a 4${\AA}$-thick doped emitter is referred to as "D-2". Under an applied voltage of 9V, the luminance of D-1 and D-2 were 7780 $cd/m^2$ and 6620 $cd/m^2$, respectively. The electroluminescent spectrum of each fabricated device showed peak emissions at the same two wavelengths: 508 nm and 596 nm. However, the relative intensity of 596 nm to 508 nm at those wavelengths was higher in the D-2 than in the D-1. The D-1 and D-2 devices showed maximum current efficiencies of 5.2 cd/A and 6.0 cd/A, and color coordinates of (0.31, 0.50) and (0.37, 0.48) on the Commission Internationale de I'Eclairage[CIE] chart, respectively.

Syntheses of Improved Polymer/Organic Materials for Electroluminescence(EL) Device and Electro-Optical Characteristics(Ⅱ) Properties of EL Device using Squarylium Dye as Emitting Material (고기능 EL소자용 고분자/유기 재료의 합성 및 전기 광학적 특성(Ⅱ) Squarylium 색소를 이용한 EL소자의 특성)

  • Kim, Sung Hoon;Bae, Jin Seok;Hwang, Seok Hwan;Park, Lee Soon
    • Journal of the Korean Chemical Society
    • /
    • v.41 no.3
    • /
    • pp.144-149
    • /
    • 1997
  • Organic electroluminescence devices(ELD) were fabricated using by molecularly doped method with N,N'-diphenyl-N,N'-bis(3-methylphenyl)-1,1'-biphenyl-4,4'-diamine(TPD) as a hole transport agent, squarylium dye as an emitting agent, and side chain liquid crystalline polymer(MCH) as matrix for TPD. An indium-tin-oxide(ITO) coated glass and an Mg electrode were used as the hole and the electron injecting electrode, respectively. The highest stability of ELD was obtained by spin coating method using dichloroethane as a solvent at a polymer/TPD concentration of 0.005 wt%. For the EL cell with ITO/polymer-TPD/SQ dye/Mg structure, we achieved light red luminescence at a current of 102 mA/$cm^2$ with an applied voltage of 23 V.

  • PDF

Occupational radiation exposure control analyses of 14 MeV neutron generator facility: A neutronic assessment for the biological and local shield design

  • Swami, H.L.;Vala, S.;Abhangi, M.;Kumar, Ratnesh;Danani, C.;Kumar, R.;Srinivasan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1784-1791
    • /
    • 2020
  • The 14 MeV neutron generator facility is being developed by the Institute for Plasma Research India to conduct the lab scale experiments related to Indian breeding blanket system for ITER and DEMO. It will also be utilized for material testing, shielding experiments and development of fusion diagnostics. Occupational radiation exposure control is necessary for the all kind of nuclear facilities to get the operational licensing from governing authorities and nuclear regulatory bodies. In the same way, the radiation exposure for the 14 MeV neutron generator facility at the occupational worker area and accessible zones for general workers should be under the permissible limit of AERB India. The generator is designed for the yield of 1012 n/s. The shielding assessment has been made to estimate the radiation dose during the operational time of the neutron generator. The facility has many utilities and constraints like ventilation ducts, accessible doors, accessibility of neutron generator components and to conduct the experiments which make the shielding assessment challenging to provide proper safety for occupational workers and the general public. The neutron and gamma dose rates have been estimated using the MCNP radiation transport code and ENDF -VII nuclear data libraries. The ICRP-74 fluence to dose conversion coefficients has been used for the assessment. The annual radiation exposure has been assessed by considering 500 h per year operational time. The provision of local shield near to neutron generator has been also evaluated to reduce the annual radiation doses. The comprehensive results of radiation shielding capability of neutron generator building and local shield design have been presented in the paper along with detailed maps of radiation field.

Hierarchical Porous 3D gel of the Co3O4/graphene with Enhanced Catalytic Performance for Green Catalysis (녹색 촉매반응을 위한 코발트 옥사이드/그래핀의 계층적 다공성 3D 젤)

  • Jeong, Jae-Min;Jang, Sukhyeun;Kim, Yunsu;Kim, Hyun Bin;Kim, Do Hyun
    • Korean Chemical Engineering Research
    • /
    • v.56 no.3
    • /
    • pp.404-409
    • /
    • 2018
  • The integration of organic and inorganic building blocks into hierarchical porous architectures makes potentially desirable catalytic material in many catalytic applications due to their combination of dissimilar components and well-constructed reactant transport path. In this study, we prepared the hierarchical porous $Co_3O_4@graphene$ 3D gel by hydrothermal method to achieve high catalytic performance in PET glycolysis reaction. Obtained $Co_3O_4@graphene$ 3D gel consisted of interconnected networks of $Co_3O_4$ and graphene sheets, providing large number of accessible active sites for efficient catalytic reaction. These structural merits from synergistic effect of $Co_3O_4$ and graphene gave a high performance in the PET degradation reaction giving high conversion yield of BHET, fast degradation rate of PET, and remarkable stability.

Clogging Phenomenon and Drainage Capacity of Tunnel Filters (터널필터재의 폐색현상과 배수성능 평가)

  • 이인모;유승헌;박광준;이석원;김홍택
    • Journal of the Korean Geotechnical Society
    • /
    • v.15 no.5
    • /
    • pp.3-18
    • /
    • 1999
  • The geotextile filter, which is installed between the ground and the lining and used as a tunnel drainage system, should have sufficient groundwater drainage capacity so that water pressure does not act on the lining. The clogging may have a serious effect on the long term behaviour of geotextile filters. Two typical weathered residual soils in Korea, Shinnae-dong soil and Poi-dong soil, were chosen to investigate the in-plane flow characteristics of the soils with varying degree of compressive stresses applied on the geotextiles and with various conditions of hydraulic gradient. The Shinnae-dong soil is a relatively coarse material classified as'SW-SM'; on the other hand, the Poi-dong soil is much finer and is classified as'SC'. Based on the comparison of the $O_{95}$ of geotextile to the $D_{15}$ of residual soils, existing clogging criteria were reviewed, and a tentative clogging criterion for the in-plane flow of the residual soil through filters was proposed. The Shinnae-dong soil showed noticeable clogging phenomenon, while the clogging of the Poi-dong soil was not so serious. The Poi-dong soil seemed to be hindered in particle transport by its cohesiveness.

  • PDF