• Title/Summary/Keyword: material matrix

Search Result 1,848, Processing Time 0.028 seconds

Electrical Properties of Organic/lnorganic Hybrid Composites for Insulation materials (유기/무기 복합 절연재료의 전기적 특성)

  • 깅상철;김현석;옥정빈;안명진;박도현;이건주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.78-83
    • /
    • 2001
  • In this work, the surface of inorganic fillers were modified with some functional groups such as stearic acid, aliphatic long chain, vinylsilane and aminosilane to control the interaction between inorganic fillers and polymer matrix. Ethylene-vinyl acetate copolymers (EVA) with various amount of vinyl-acetate content and copolyether-ester elastomer were used as polymer matrix. The addition of inorganic fillers increases flame retardancy, but results in steep drop of electrical and mechanical properties, which may be caused by the defect in the interface between organic/inorganic hybrid composites. The hybrid composites are found to show better mechanical properties and higher volume resistivities as inorganic fillers are well dispersed and have good adhesion with polymer matrix. Also, the most effective type of functional group coated on fillers depends on the chemical structure of polymer.

  • PDF

Sound Absorption Performance of a Helmholtz Resonator combined with Porous Materials (흡음재가 조합된 헬름홀츠 공명기의 흡음성능)

  • Lee, Young-Chul;Lee, Sun-Ki;Song, Hwa-Young;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.280-285
    • /
    • 2008
  • The helmholtz resonator with the perforated neck has demerits that the absorption performance is not so outstanding in an anti-resonance frequency and high frequency bandwidth. In order to overcome these problems, in the paper, a resonator combined with porous material is proposed. The absorption performances of resonators are measured by two-microphone method and estimated by transfer matrix method. The experimentally measured values of normal absorption coefficients agree well with the corresponding values from the transfer matrix method. Because of the porous material, it is shown that the absorption performance have been significantly improved in the anti-resonance frequency and high frequency bandwidth.

  • PDF

A Study on the Micro-mechanical Characteristics of Vacuum Hot Pressed Titanium Metal Matrix Composites (고온진공가압 티타늄 금속기 복합재료의 미시-기계적 특성에 관한 연구)

  • 하태준;김태원
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.207-210
    • /
    • 2003
  • Vacuum hot pressing has been used for the development of Ti-MMCs using foil-fiber-foil method, and subsequent micro-mechanical characteristics of the composites are evaluated by means of several experimental processes. As shown by the results, fiber strength degradation occurs during the consolidation, and particularly residual stresses results from the thermal expansion mismatch between fiber and matrix materials during cooling process are incorporated in the changes of mechanical properties of the composites. In industrial applications, the processing conditions avoiding micro-material failures are important together with the properties of finished products, and therefore should be included in the assesment of the material characterization.

  • PDF

A Study on the Improvement of Microcrack Resistance of Carbon/Epoxy Composites at Cryogenic Temperature (극저온에서 탄소 섬유/에폭시 복합재료의 군열 저항성 향상에 관한 연구)

  • Hong, Joong-Sik;Kim, Myung-Gon;Kim, Chun-Gon;Kong, Cheol-Won
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.49-52
    • /
    • 2005
  • In the development of a propellant tank using liquid oxygen and liquid hydrogen, the improvement of microcrack resistance of carbon/epoxy composites is necessary for the application of a composite material to tank structures. In this research, two types of carbon/epoxy composites with different matrix systems were tested to measure interlaminar shear strength (ILSS), one of the material properties to evaluate fiber-matrix interface adhesion indirectly. Short beam specimens were tested inside an environmental chamber at room temperature(RT) and at cryogenic temperature( - 150 $^{\circ}C$) respectively. Results showed that the matrix system with large amount of bisphenol-A and CTBN modified rubber had good performance at cryogenic temperature.

  • PDF

A Study on the Sound Absorption Performance of a Helmholtz Resonator Combined with Porous Materials (흡음재가 조합된 헬름홀츠 공명기의 흡음성능에 관한 연구)

  • Lee, Dong-Hoon;Song, Hwa-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.628-633
    • /
    • 2009
  • The helmholtz resonator with the perforated neck has demerits that the absorption performance is not so outstanding in an anti-resonance frequency and high frequency bandwidth. In order to overcome these problems, in the paper, a resonator combined with porous material is proposed. The absorption performances of resonators are measured by two-microphone method and estimated by transfer matrix method. The experimentally measured values of normal absorption coefficients agree well with the corresponding values from the transfer matrix method. Because of the porous material, it is shown that the absorption performance have been significantly improved in the anti-resonance frequency and high frequency bandwidth.

Electrical Discharge Machining of Alumina Ceramic Matrix Composites Containing Electro-conductive Titanium Carbide as a Second Phase (도전성 탄화티타늄 이차상을 포함하는 산화알루니늄기 세라믹 복합체의 방전가공)

  • 윤존도;왕덕현;안영철;고철호
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.10
    • /
    • pp.1092-1098
    • /
    • 1997
  • Electrical discharge machining (EDM) was attempted on a ceramic matrix composite containing non-conductive alumina as a matrix and conductive titania as a second phase, and was found successful. As the current or duty factor increased, the material removal rate (MRR) increased and the surface roughness also increased. The EDMed surface was covered with a number of craters of a circular shape having 100-200 microns of diameter. The melting and evaporation was suggested for the EDM mechanism. The bending strength decreased 44% after EDM, but the Weibull modulus increased more than twice. Combination of EDM and barre이 polishing resulted in the maintenance of the bending strength level. Temperature distribution near a spark in the sample was computer-simulated by use of finite element method, and was found to have similar shape to the one which the observed craters have.

  • PDF

The Strength Characteristics of Polymer Composites Injection Parts for Lightness and Safety (경량화와 안전을 위한 폴리머 복합재료 사출품의 강도특성)

  • Yun, Yeo-Kwon;Kim, Jin-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.4
    • /
    • pp.101-108
    • /
    • 2011
  • In this paper deals with strength of glass fiber reinforced plastics produced by shouting machine was investigated by universal testing instrument. We can obtain following results by performing the strength evaluation of polymer composite material according as varied environment temperature. The effect of environmental temperature on Strength properties was more sensitive in the weld specimen than parent. When changed environmental temperature, variation of strength in the parent was much bigger than it of weld specimen, that is, matrix in the parent, orientation in the specimen ware more sensitive to environmental strength. Tensile strength of polycarbonate matrix was similar regardless of mold temperature.

Design of the Self-Calibrated OJA Converter with Current Source Matrix Stricture (셀프 캘리브레이션 기법을 이용한 행렬 디코딩 D/A 컨버터의 설계에 관한 연구)

  • 임현욱;강호철;김순도;성만영
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.243-246
    • /
    • 1998
  • This paper presents a 6-bit self-calibrated D/A converter designed with current cell matrix structure. This structure is based on the current-cell matrix configuration using a regulated gate cascode current cell with 3-way switch. using from CMOS process and 5V power supply, the simulated conversion rate is 45.78MHz and the average mismatching properties among current sources are reduced to 0.02% and 0.005%, respectively when 1% and 0.5% errors of current sources are considered.

  • PDF

The role of softening in the numerical analysis of R.C. framed structures

  • Bontempi, Franco;Malerba, Pier Giorgio
    • Structural Engineering and Mechanics
    • /
    • v.5 no.6
    • /
    • pp.785-801
    • /
    • 1997
  • Reinforced Concrete beams with tension and compression softening material constitutive laws are studied. Energy-based and non-local regularisation techniques are presented and applied to a R.C. element. The element characteristics (sectional tangent stiffness matrix, element tangent stiffness matrix restoring forces) are directly derived from their symbolic expressions through numerical integration. In this way the same spatial grid allows us to obtain a non-local strain estimate and also to sample the contributions to the element stiffness matrix. Three examples show the spurious behaviors due to the strain localization and the stabilization effects given by the regularisation techniques, both in the case of tension and compression softening. The possibility to overestimate the ultimate load level when the non-local strain measure is applied to a non softening material is shown.

Dissolution Characterstics of Indomethacin Microcapsules Prepared Using Gelatin-Gum Arabic Complex Coacervation (젤라틴-아리비아고무를 써서 製造한 인도메타신 마이크로캅셀의 용출 특성)

  • Ku, Young-Soon;Kim, Hwa-Yeon
    • YAKHAK HOEJI
    • /
    • v.28 no.4
    • /
    • pp.223-229
    • /
    • 1984
  • Microcapsules of indomethacin were prepared by the complex coacervation technique using gelatin-gum arabic as the wall-forming material. The effects of varying drug-to-matrix ratios and formalization time, and hydroxy propyl cellulose (HPC) added on the release of drug from microcapsules were studied. As the amount of wall-forming material increased, the drug content in the microcapsules decreased and the release of drug from microcapsules was retarded. The drug content was lower in the HPC added microcapsules than that in the microcapsules was retarded. The drug content was lower in the HPC added microcapsules than that in the microcapsules without HPC and the microcapsules with 1:4 drug-to-matrix ratio showed the slowest release. The release rate of the drug from microcapsules with 1:2 drug-to-matrix was delayed according to the increase of formalization time and the microcapsules formalized for 24hr showed ratio the most retardation.

  • PDF