• Title/Summary/Keyword: material homogeneity

Search Result 160, Processing Time 0.026 seconds

A Study of Material Characteristics of 120mm-Thick SM490TMC Plate (SM490TMC 극후판재 120mm의 소재특성에 관한 연구)

  • Kim, Sang Seup;Lee, Cheol Ho;Lee, Eun Taik;Han, Tae Ho;Choi, Young Han;Kim, Jong Rak
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.5
    • /
    • pp.313-323
    • /
    • 2016
  • Seven types of tests were conducted to experimentally evaluate the material properties of ultral-thick (or 120mm-thick) SM490TMC plate. The investigation of through-thickness properties was among the most significant considerations. All chemical and mechanical test results showed the through-thickness homogeneity as required and conformed to the KS(Korean industrial Standards), although the thickness was 1.5 times thicker than the thickness limit (80mm) imposed by Steel Structure Design Code. No reduction in the yield strength of 120mm-thick SM490TMC plate is recommended for design.

Comparison of Three Different Helmet Bolus Device for Total Scalp Irradiation (Total Scalp의 방사선 치료 시 Helmet Bolus 제작방법에 관한 연구)

  • Song, Yong-Min;Kim, Jong-Sik;Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young;Park, Su-Yeon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.31-37
    • /
    • 2012
  • Purpose: This study evaluated the usefulness of Helmet bolus device using Bolx-II, paraffin wax, solid thermoplastic material in total scalp irradiation. Materials and Methods: Using Rando phantom, we applied Bolx-II (Action Products, USA), paraffin wax (Densply, USA), solid thermoplastic material (Med-Tec, USA) on the whole scalp to make helmet bolus device. Computed tomography (GE, Ultra Light Speed16) images were acquired at 5 mm thickness. Then, we set up the optimum treatment plan and analyzed the variation in density of each bolus (Philips, Pinnacle). To evaluate the dose distribution, Dose-homogeneity index (DHI, $D_{90}/D_{10}$) and Conformity index (CI, $V_{95}/TV$) of Clinical Target Volume (CTV) using Dose-Volume Histogram (DVH) and $V_{20}$, $V_{30}$ of normal brain tissues. we assessed the efficiency of production process by measuring total time taken to produce. Thermoluminescent dosimeters (TLD) were used to verify the accuracy. Results: Density variation value of Bolx-II, paraffin wax, solid thermoplastic material turned out to be $0.952{\pm}0.13g/cm^3$, $0.842{\pm}0.17g/cm^3$, $0.908{\pm}0.24g/cm^3$, respectively. The DHI and CI of each helmet bolus device which used Bolx-II, paraffin wax, solid thermoplastic material were 0.89, 0.85, 0.77 and 0.86, 0.78, 0.74, respectively. The result of Bolx-II was the best. $V_{20}$ and $V_{30}$ of brain tissues were 11.50%, 10.80%, 10.07% and 7.62%, 7.40%, 7.31%, respectively. It took 30, 120, 90 minutes to produce. The measured TLD results were within ${\pm}7%$ of the planned values. Conclusion: The application of helmet bolus which used Bolx-II during total scalp irradiation not only improves homogeneity and conformity of Clinical Target Volume but also takes short time and the production method is simple. Thus, the helmet bolus which used Bolx-II is considered to be useful for the clinical trials.

  • PDF

A theoretical approach in 2d-space with applications of the periodic wave solutions in the elastic body

  • Ramady, Ahmed;Mahmoud, S.R.;Atia, H.A.
    • Membrane and Water Treatment
    • /
    • v.11 no.4
    • /
    • pp.295-302
    • /
    • 2020
  • In this paper, theoretical approach with applications of the periodic wave solutions in an elastic material is applied by study the effect of initial stress, and rotation, on the radial displacement and the corresponding stresses in non-homogeneous orthotropic material. An Analytical solution for the elastodynamic equation has obtained concerning the component of displacement. The variations of stresses and displacements have shown graphically. Comparisons with previously published results in the absence of initial stress, rotation and non-homogeneity have made. Finally, numerical results have given and illustrated graphically for each case considered.

The Influence of Drawing Parameters on Sausaging and Critical Current of Bi-2223/Ag HTS Wires. (Bi-2223/Ag 고온 초전도 선재의 임계전류 및 소세징에 미치는 인발 조건의 영향)

  • 하홍수;오상수;하동우;김상철;권영길;류강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.488-491
    • /
    • 2000
  • Bi-2223/Ag superconducting wires have been mainly prepared by a powder-in-tube method. The drawing and the rolling are main processes to increase the core density and wire length. In the fabrication of long wire, especially, the drawing should be precisely controlled to assure the filament homogeneity. In this paper, the influences of drawing die angle, bearing length and reduction ratio on the sausaging and the critical current density of the wire are investigated. Single cored and multi-filamentary wires are fabricated by PIT method with different conditions. The core densities and sausaging in the wires are investigated and are discussed regarding their relationship to the I$_{c}$. It was made clear that the geometry of drawing die is sensitively dependent on the sausaging. The improvement of I$_{c}$ was achieved by reducing the die angle and high core density.ity.

  • PDF

$I_c$ Degradation Behavior in YBCO Coated Conductors under Torsional Strain (YBCO 박막도체의 비틀림 변형률에 따른 임계전류 열화거동)

  • Shin, Hyung-Seop;Dizon, John Ryan C;Kim, Tae-Young;Ko, Rock-Kil;Oh, Sang-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.93-94
    • /
    • 2006
  • The $I_c$ degradation behavior of YBCO CC tapes due to torsional deformation has been investigated. Particularly, the influence of torsion angle on the $I_c$ in HTS tapes was examined at 77K (self-field). At low torsional angles or shear strains, the $I_c$ degradation was small and gradual. Also, a good consistency of the $I_c$ degradation behaviors was found along the longitudinal direction under torsion when multiple voltage terminals were adopted for investigating the homogeneity of the $I_c$ degradation.

  • PDF

Development of a Nutritional Supplement Certified Reference Material for Elemental Analysis

  • Lee, Jong Wha;Heo, Sung Woo;Kim, Hwijin;Lim, Youngran;Lee, Kyoung-Seok;Yim, Yong-Hyeon
    • Mass Spectrometry Letters
    • /
    • v.9 no.4
    • /
    • pp.105-109
    • /
    • 2018
  • A certified reference material (CRM) for the analysis of inorganic nutrients in nutritional supplements has been developed. Accurate mass fractions of chromium (Cr), iron (Fe), copper (Cu), and zinc (Zn) were determined by isotope dilution inductively coupled plasma mass spectrometry (ID ICP/MS). The measurement results were used to assign certified values for the CRM, which were metrologically traceable to the definitions of the measurement units in the International System of Units (SI). Production of a candidate reference material (RM) and the certification processes are summarized. Each nutrient in the CRM showed good homogeneity, which was estimated using relative standard deviations of the measurement results of twelve bottles in a batch. This CRM is expected to be an important reference to improve reliability and comparability of nutrient analyses in nutritional supplements and related samples in analytical laboratories.

Preparation and Certification of Rice Flour Reference Materials for Trace Elements Analysis (미량원소분석을 위한 쌀분말 기준물질의 제조 및 검정)

  • Cho, Kyung-Haeng;Park, Chang-Joon;Woo, Jin-Choon;Suh, Jung-Ki;Han, Myung-Sub;Lee, Jong-Hae
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.271-280
    • /
    • 1998
  • Rice flour reference materials were prepared from the unpolished rice grown in Korea and certified for elemental composition. The reference materials consist of two samples containing normal and high level. The reference material at elevated level was prepared by spiking to the normal rice flour six toxic elements of As, Cd, Cu, Cr, Hg, Pb with $1.0{\mu}g/g$ on a dry weight basis. Homogeneity of the prepared materials was evaluated through the determination of Ca, Cu, Fe, Mn, Zn by instrumental neutron activation analysis (INAA) and atomic absorption spectrometry (AAS). Small variance of elemental composition among interbottled samples assured homogeneity of the prepared materials. The materials were decomposed by high pressure digestion and microwave digestion method. INAA, AAS, inductively coupled plasma-atomic absorption spectrometry (ICP-AES), ICP-mass spectrometry (MS) and vapour generation techniques were employed to analyze the reference materials. From this independent analytical results, the certified or reference values are determined for As, Ca, Cd, Cr, Cu, Fe, Hg, K, Mg, Mn, Mo, Na, P, Pb, Se, Zn.

  • PDF

Evaluation of thermal stability of quasi-isotropic composite/polymeric cylindrical structures under extreme climatic conditions

  • Gadalla, Mohamed;El Kadi, Hany
    • Structural Engineering and Mechanics
    • /
    • v.32 no.3
    • /
    • pp.429-445
    • /
    • 2009
  • Thermal stability of quasi-isotropic composite and polymeric structures is considered one of the most important criteria in predicting life span of building structures. The outdoor applications of these structures have raised some legitimate concerns about their durability including moisture resistance and thermal stability. Exposure of such quasi-isotropic composite/polymeric structures to various and severe climatic conditions such as heat flux and frigid climate would change the material behavior and thermal viability and may lead to the degradation of material properties and building durability. This paper presents an analytical model for the generalized problem. This model accommodates the non-linearity and the non-homogeneity of the internal heat generated within the structure and the changes, modification to the material constants, and the structural size. The paper also investigates the effect of the incorporation of the temperature and/or material constant sensitive internal heat generation with four encountered climatic conditions on thermal stability of infinite cylindrical quasi-isotropic composite/polymeric structures. This can eventually result in the failure of such structures. Detailed critical analyses for four case studies which consider the population of the internal heat generation, cylindrical size, material constants, and four different climatic conditions are carried out. For each case of the proposed boundary conditions, the critical thermal stability parameter is determined. The results of this paper indicate that the thermal stability parameter is critically dependent on the cylinder size, material constants/selection, the convective heat transfer coefficient, subjected heat flux and other constants accrued from the structure environment.

Dynamic response of non-uniform Timoshenko beams made of axially FGM subjected to multiple moving point loads

  • Gan, Buntara S.;Trinh, Thanh-Huong;Le, Thi-Ha;Nguyen, Dinh-Kien
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.981-995
    • /
    • 2015
  • This paper presents a finite element procedure for dynamic analysis of non-uniform Timoshenko beams made of axially Functionally Graded Material (FGM) under multiple moving point loads. The material properties are assumed to vary continuously in the longitudinal direction according to a predefined power law equation. A beam element, taking the effects of shear deformation and cross-sectional variation into account, is formulated by using exact polynomials derived from the governing differential equations of a uniform homogenous Timoshenko beam element. The dynamic responses of the beams are computed by using the implicit Newmark method. The numerical results show that the dynamic characteristics of the beams are greatly influenced by the number of moving point loads. The effects of the distance between the loads, material non-homogeneity, section profiles as well as aspect ratio on the dynamic responses of the beams are also investigated in detail and highlighted.

Characterization of MAl2O4:Eu2+(M=Sr,Ba,Ca) Synthesised by Sol-gel Method (졸겔법으로 합성된 Mal2O4:Eu2+(M=Sr,Ba,Ca)의 특성)

  • Lim, Kyu;Kim, Young-Hyun;Lee, Hyung-Jik;Kim, Sei-Ki;Lee, Hyung-Bock
    • Journal of the Korean Ceramic Society
    • /
    • v.46 no.6
    • /
    • pp.679-684
    • /
    • 2009
  • Phosphors of $Eu^{2+}$ doped alkaline earth aluminates MA$l_2O_4:Eu^{2+}$ (M=Sr, Ba, Ca) have been prepared by sol-gel process and their characterization of photoluminescence and photocurrent properties have been performed. The phosphors prepared by sol-gel process, due to its advantage of better homogeneity and low synthetic temperature, was synthesized as single phases at lower temperature than the solid-state process; $800{\sim}1000{^{\circ}C}$ for 6 h under mild reduction atmosphere (Ar- 3% $H_2$). It was confirmed that SrA$l_2O_4:Eu^{2+}$ composition revealed the most excellent properties in the brightness and photocurrent.