• Title/Summary/Keyword: matched file

Search Result 18, Processing Time 0.022 seconds

A Robust Approach of Regression-Based Statistical Matching for Continuous Data

  • Sohn, Soon-Cheol;Jhun, Myoung-Shic
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.2
    • /
    • pp.331-339
    • /
    • 2012
  • Statistical matching is a methodology used to merge microdata from two (or more) files into a single matched file, the variants of which have been extensively studied. Among existing studies, we focused on Moriarity and Scheuren's (2001) method, which is a representative method of statistical matching for continuous data. We examined this method and proposed a revision to it by using a robust approach in the regression step of the procedure. We evaluated the efficiency of our revised method through simulation studies using both simulated and real data, which showed that the proposed method has distinct advantages over existing alternatives.

Assessment of postoperative pain after single-visit root canal treatment using rotary and reciprocating file systems: an in vivo study

  • Shaik, Reshma Parveen;Chukka, Ram Sunil;Bandlapally, Anila;Vemuri, Sayesh;Bolla, Nagesh;Basam, Ram Chowdary;Tammineedi, Sravanthi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.4
    • /
    • pp.267-275
    • /
    • 2022
  • Background: Various instrument kinematics used in single-visit endodontics influence the occurrence of pain after endodontic therapy. This study aimed to evaluate the occurrence of pain after mechanical instrumentation with Hyflex EDM (HEDM) and WaveOne Gold (WOG) during single-visit endodontic therapy. Methods: Sixty patients diagnosed with asymptomatic irreversible pulpitis and normal apical tissues in mandibular premolar teeth were included in the study for single-visit root canal therapy. The patients were divided into two groups (n = 30) according to the rotary instrument used during root canal preparation (group A [HEDM] and group B [WOG]). Pain was evaluated after endodontic therapy at 8, 24, and 48 h intervals using the visual analog scale (VAS). Data obtained were analyzed using the chi-square test, independent t-test, MannWhitney U test, and Wilcoxon matched-pairs test. Results: Statistically significant differences were observed between the two groups (P < 0.001) at 8, 24, and 48 h, with WOG exhibiting less pain than HEDM files. Conclusion: Postoperative pain was lower in the WOG file system than in the HEDM file system after single-visit root canal therapy at 8, 24, and 48 h.

A Pattern Summary System Using BLAST for Sequence Analysis

  • Choi, Han-Suk;Kim, Dong-Wook;Ryu, Tae-W.
    • Genomics & Informatics
    • /
    • v.4 no.4
    • /
    • pp.173-181
    • /
    • 2006
  • Pattern finding is one of the important tasks in a protein or DNA sequence analysis. Alignment is the widely used technique for finding patterns in sequence analysis. BLAST (Basic Local Alignment Search Tool) is one of the most popularly used tools in bio-informatics to explore available DNA or protein sequence databases. BLAST may generate a huge output for a large sequence data that contains various sequence patterns. However, BLAST does not provide a tool to summarize and analyze the patterns or matched alignments in the BLAST output file. BLAST lacks of general and robust parsing tools to extract the essential information out from its output. This paper presents a pattern summary system which is a powerful and comprehensive tool for discovering pattern structures in huge amount of sequence data in the BLAST. The pattern summary system can identify clusters of patterns, extract the cluster pattern sequences from the subject database of BLAST, and display the clusters graphically to show the distribution of clusters in the subject database.

Storing and Retrieving Motion Capture Data based on Motion Capture Markup Language and Fuzzy Search (MCML 기반 모션캡처 데이터 저장 및 퍼지 기반 모션 검색 기법)

  • Lee, Sung-Joo;Chung, Hyun-Sook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.2
    • /
    • pp.270-275
    • /
    • 2007
  • Motion capture technology is widely used for manufacturing animation since it produces high quality character motion similar to the actual motion of the human body. However, motion capture has a significant weakness due to the lack of an industry wide standard for archiving and retrieving motion capture data. In this paper, we propose a framework to integrate, store and retrieve heterogeneous motion capture data files effectively. We define a standard format for integrating different motion capture file formats. Our standard format is called MCML (Motion Capture Markup Language). It is a markup language based on XML (eXtensible Markup Language). The purpose of MCML is not only to facilitate the conversion or integration of different formats, but also to allow for greater reusability of motion capture data, through the construction of a motion database storing the MCML documents. We propose a fuzzy string searching method to retrieve certain MCML documents including strings approximately matched with keywords. The method can be used to retrieve desired series of frames included in MCML documents not entire MCML documents.

X-Ray Diffraction Analysis of Various Calcium Silicate-Based Materials

  • An, So-Youn;Lee, Myung-Jin;Shim, Youn-Soo
    • Journal of dental hygiene science
    • /
    • v.22 no.3
    • /
    • pp.191-198
    • /
    • 2022
  • Background: The purpose of this study was to evaluate the composition of the crystal phases of various calcium silicate-based materials (CSMs): ProRoot white MTA (mineral trioxide aggregate) (WMTA), Ortho MTA (OM), Endocem MTA (EM), Retro MTA (RM), Endocem Zr (EN-Z), BiodentineTM (BD), EZ-sealTM (EZ), and OrthoMTA III (OM3). Methods: In a sample holder, 5 g of the powder sample was placed and the top surface of the material was packed flat using a sterilized glass slide. The prepared slides were mounted on an X-ray diffraction (XRD) instrument (D8 Advance; Bruker AXS GmbH, Germany). The X-ray beam 2θ angle range was set at 10~90° and scanned at 1.2° per minute. The Cu X-ray source set to operate at 40 kV and 40 mA in the continuous mode. The peaks in the diffraction pattern of each sample were analyzed using the software Diffrac (version 2.1). Then, the peaks were compared and matched with those of standard materials in the corresponding Powder Diffraction File (PDF-2, JCPDS International Center for Diffraction Data). A powder samples of the materials were analyzed using XRD and the peaks in diffraction pattern were compared to the Powder Diffraction File data. Results: Eight CSMs showed a similar diffraction pattern because their main component was calcium silicate. Eight CSMs showed similar diffraction peaks because calcium silicate was their main component. Two components were observed to have been added as radiopacifiers: bismuth oxide was detected in WMTA, OM, and EM while zirconium oxide was detected in RM, EN-Z, BD, EZ, and OM3. Unusual patterns were detected for the new material, OM3, which had strong peaks at low angles. Conclusion: It was caused by the presence of Brushite, which is believed to have resulted in crystal growth in a particular direction for a specific purpose.

An Automated Draft Report Generator for Peripheral Blood Smear Examinations Based on Complete Blood Count Parameters

  • Kim, Young-gon;Kwon, Jung Ah;Moon, Yeonsook;Park, Seong Jun;Kim, Sangwook;Lee, Hyun-A;Ko, Sun-Young;Chang, Eun-Ah;Nam, Myung-Hyun;Lim, Chae Seung;Yoon, Soo-Young
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.512-517
    • /
    • 2018
  • Background: Complete blood count (CBC) results play an important role in peripheral blood smear (PBS) examinations. Many descriptions in PBS reports may simply be translated from CBC parameters. We developed a computer program that automatically generates a PBS draft report based on CBC parameters and age- and sex-matched reference ranges. Methods: The Java programming language was used to develop a computer program that supports a graphical user interface. Four hematology analyzers from three different laboratories were tested: Sysmex XE-5000 (Sysmex, Kobe, Japan), Sysmex XN-9000 (Sysmex), DxH800 (Beckman Coulter, Brea, CA, USA), and ADVIA 2120i (Siemens Healthcare Diagnostics, Eschborn, Germany). Input data files containing 862 CBC results were generated from hematology analyzers, middlewares, or laboratory information systems. The draft reports were compared with the content of input data files. Results: We developed a computer program that reads CBC results from a data file and automatically writes a draft PBS report. Age- and sex-matched reference ranges can be automatically applied. After examining PBS, users can modify the draft report based on microscopic findings. Recommendations such as suggestions for further evaluations are also provided based on morphological findings, and they can be modified by users. The program was compatible with all four hematology analyzers tested. Conclusions: Our program is expected to reduce the time required to manually incorporate CBC results into PBS reports. Systematic inclusion of CBC results could help improve the reliability and sensitivity of PBS examinations.

A Novel Query-by-Singing/Humming Method by Estimating Matching Positions Based on Multi-layered Perceptron

  • Pham, Tuyen Danh;Nam, Gi Pyo;Shin, Kwang Yong;Park, Kang Ryoung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.7
    • /
    • pp.1657-1670
    • /
    • 2013
  • The increase in the number of music files in smart phone and MP3 player makes it difficult to find the music files which people want. So, Query-by-Singing/Humming (QbSH) systems have been developed to retrieve music from a user's humming or singing without having to know detailed information about the title or singer of song. Most previous researches on QbSH have been conducted using musical instrument digital interface (MIDI) files as reference songs. However, the production of MIDI files is a time-consuming process. In addition, more and more music files are newly published with the development of music market. Consequently, the method of using the more common MPEG-1 audio layer 3 (MP3) files for reference songs is considered as an alternative. However, there is little previous research on QbSH with MP3 files because an MP3 file has a different waveform due to background music and multiple (polyphonic) melodies compared to the humming/singing query. To overcome these problems, we propose a new QbSH method using MP3 files on mobile device. This research is novel in four ways. First, this is the first research on QbSH using MP3 files as reference songs. Second, the start and end positions on the MP3 file to be matched are estimated by using multi-layered perceptron (MLP) prior to performing the matching with humming/singing query file. Third, for more accurate results, four MLPs are used, which produce the start and end positions for dynamic time warping (DTW) matching algorithm, and those for chroma-based DTW algorithm, respectively. Fourth, two matching scores by the DTW and chroma-based DTW algorithms are combined by using PRODUCT rule, through which a higher matching accuracy is obtained. Experimental results with AFA MP3 database show that the accuracy (Top 1 accuracy of 98%, with an MRR of 0.989) of the proposed method is much higher than that of other methods. We also showed the effectiveness of the proposed system on consumer mobile device.

Evaluation of the Usefulness of Patient Customized Shielding Block Made with 3D Printer in the Skin Cancer Electron Beam Therapy (전자선치료 시 3D 프린터로 제작한 환자 맞춤형 차폐체의 유용성 평가)

  • Ahn, Ki-Song;Jung, Woo-Chan;Kim, Dae-Hyun;Kim, Moo-Sub;Yoon, Do-Kun;Shim, Jae-Goo;Suh, Tae-Suk
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.447-454
    • /
    • 2019
  • In order to improve and supplement the shielding method for electron beam treatment, we designed a patient-specific shielding method using a 3D printer, and evaluated the usefulness by comparing and analyzing the distribution of electron beam doses to adjacent organs. In order to treat 5 cm sized superficial tumors around the lens, a CT Simulator was used to scan the Alderson Rando phantom and the DICOM file was converted into an STL file. The converted STL file was used to design a patient-specific shield and mold that matched the body surface contour of the treatment site. The thickness of the shield was 1 cm and 1.5 cm, and the mold was printed using a 3D printer, and the patient customized shielding block (PCSB) was fabricated with a cerrobend alloy with a thickness of 1 cm and 1.5 cm. The dosimetry was performed by attaching an EBT3 film on the surface of the Alderson Rando phantom eyelid and measuring the dose of 6, 9, and 12 MeV electron beams on the film using four shielding methods. Shielding rates were 83.89%, 87.14%, 87.39% at 6, 9, and 12 MeV without shielding, 1 cm (92.04%, 87.48%, 86.49%), 1.5 cm (91.13%, 91.88% with PSCB), 92.66%) The shielding rate was measured as 1 cm (90.7%, 92.23%, 88.08%) and 1.5 cm (88.31%, 90.66%, 91.81%) when the shielding block and the patient-specific shield were used together. PCSB fabrication improves shielding efficiency over conventional shielding methods. Therefore, PSCB may be useful for clinical application.

Direct Slicing with Optimum Number of Contour Points

  • Gupta Tanay;Chandila Parveen Kumar;Tripathi Vyomkesh;Choudhury Asimava Roy
    • International Journal of CAD/CAM
    • /
    • v.4 no.1
    • /
    • pp.33-45
    • /
    • 2004
  • In this work, a rational procedure has been formulated for the selection of points approximating slice contours cut in LOM (Laminated Object manufacturing) with first order approximation. It is suggested that the number of points representing a slice contour can be 'minimised' or 'optmised' by equating the horizontal chordal deviation (HCD) to the user-defined surface form tolerance. It has been shown that such optimization leads to substantial reduction in slice height calculations and NC codes file size for cutting out the slices. Due to optimization, the number of contour points varies from layer to layer, so that points on successive layer contours have to be matched by four sided ruled surface patches and triangular patches. The technological problems associated with the cutting out of triangular patches have been addressed. A robust algorithm has been developed for the determination of slice height for optimum and arbitrary numbers of contour points with different strategies for error calculations. It has been shown that optimisation may even lead to detection and appropriate representation of elusive surface features. An index of optimisation has been defined and calculations of the same have been tabulated.

Implementation of an indoor wireless modem using direct sequence spectrum technology (직접시퀀스 대역 확산 방식을 이용한 실내 무선 모뎀의 구현)

  • 박병훈;김호준;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2141-2152
    • /
    • 1998
  • In this paper, we design and implement an indoor wireless modem using small signal of ISM band regulation, which can tranceive reliable data streams. We use direct sequence spead spectrum (DS-SS) signaling with synchronous BPSK and QPSK modulation, convolutional coding with viterbi decoding. The radio frequency module uses frequency devision duplexing in 900 MHz band, and the digital module is implemented with FPGAs for the purpose fo ASIC design. The perfomrance of our own acquistion and tracking circuit consisting digital matched filter and decision logic is proved by experiments, and the possibility of file transfer at indoor environment with the entrie system that the modem is connected the PC through RS-232C port is verified.

  • PDF