• 제목/요약/키워드: masticatory mucosa

검색결과 14건 처리시간 0.034초

구개 및 치아 형태와 구개부 저작점막의 두께와의 연관성 (Relationship between The Shape of Palatal Vault and Tooth and The Thickness of Palatal Masticatory Mucosa)

  • 석화숙;이만섭;권영혁;박준봉
    • Journal of Periodontal and Implant Science
    • /
    • 제33권3호
    • /
    • pp.519-531
    • /
    • 2003
  • The aim of present investigation was to clinically measure the thickness of palatal masticatory mucosa in the hard palate as potential donor site for mucogingival surgery, to determine the relation to shape of palatal vault, form of tooth, gender, and to serve the clinical criteria t o choose the proper surgical technique. 84(mean age:25yrs) systemically and periodontally healthy volunteers participated in this study and 18 standard measurement points were defined in the hard palate, located on 3 lies which ran at different distances parallel to the gingival margin. 6 positions were designated on each of these 3 lines between the level of canine and 2nd molar and a bone sounding technique using a periodontal probe with minimal local anesthesia was utilized to assess the thickness of palatal masticatory mucosa. Student t-test was used to determine the difference in mucosal thickness between 2 groups gender, shape of palatal vault (high palatal vault vs. low palatal vault), tooth form (short-wide vs. long narrow) The result of this study were as follows: 1. Soft tissue thickness progressively increased in sites further away from the gingival margin (p<0.01). 2. Depending on position, in line a and line c the masticatory mucosal thickness increased from Ca to M2(p<0.01), but in line b the thickness increased from Ca to P2, and decreased to M1 and increased again to M2. 3. Gender did not influence the thickness of masticatory mucosa. 4. Palatal vault shape was associated with the thickness of masticatory mucosa. Thickness of low palatal vault group was thicker than high palatal group between P2 and M2 position. 5. Form of tooth did not influence the thickness of masticatory mucosa. In conclusion, palatal vault shape was associated with the thickness of masticatory mucosa. So, mucogingival surgery can be considered as a treatment modality in high palatal vault group. But, Gender and tooth form did not influence the thickness of masticatory mucosa.

구개 저작 점막의 두께에 대한 연구 (The thickness of palatal masticatory mucosa)

  • 한광희;김동진;윤정호;정의원;김창성;조규성;채중규;김종관;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.573-580
    • /
    • 2004
  • The Palatal masticatory mucosa was widely used as a donor site in periodontal and implant surgery. but there were relatively few studies investigating the thickness of the palatal mucosa in dentate subjects. The purpose of this study was to study the thickness of palatal masticatory mucosa in korean subjects by direct clinical technique. Forty systemically and periodontally healthy subjects(20 males:20 females) participated in this study. A bone sounding method using a periodontal probe with minimal anesthesia and a prepared clear acrylic stent was utilized to assess the thickness of palatal mucosa at 24 measurement points defined according to the gingival margin and mid palatal suture. The results are as follows; 1. Mean thickness of palatal masticatory mucosa was $3.5{\pm}0.4mm$. and no gender differences were identified in the thickness of palatal masticatory mucosa. 2. The thickness of palatal masticatory mucosa increased from canine to second molar area(with the exception of the first molar area). canine and first molar areas were significantly thinner than other areas(P<0.05). 3. The thickness of palatal masticatory mucosa significantly increased in the sites farther from the gingival margin towarding the mid-palate(P<0.05). The results suggest that within the limits of the present study, premolar area appears to be the most appropriate donor site for soft tissue grafting procedures.

전산화단층촬영법을 통한 한국인의 구개 저작 점막 두께에 대한 연구 (Measurement of soft tissue thickness on posterior palatal area by using computerized tomography in Korean population)

  • 송지은;채경준;정의원;김창성;최성호;조규성;김종관;채중규
    • Journal of Periodontal and Implant Science
    • /
    • 제37권1호
    • /
    • pp.103-113
    • /
    • 2007
  • The purpose of this study was to measure the thickness of masticatory mucosa in the hard palate as a donor site for mucogingival surgery by using computerized tomography(CT), Thickness measurements were performed in 84 adult patients who took CT on maxilla for implant surgery and 24 standard measurement points were defined in the hard palate according to the gingival margin and mid palatal suture. Radiographic measurements were utilized after calibration for standardization. Data were analyzed to determine the differences in mucosal thickness by gender, age, tooth positions and depth of palatal vault. The results of this study were as follows: 1. Mean thickness of palatal masticatory mucosa was $3.93{\pm}0.6mm$ and females had significantly thinner mean masticatory mucosa($3.76{\pm}0.56mm$) than males($4.04{\pm}0.6mm$)(p<0.05). 2. The thickness of palatal masticatory mucosa increased by aging. 3. Depending on position, masticatory mucosa thickness increased from canine to premeolar, but decreased at the first molar, and increased again in the second molar region(p<0.0001). 4. No significant difference in mean thickness of palatal masticatory mucosa were indentified between low palatal vault group and high palatal vault group(p>0.05). The results suggest that canine and premolar area appears to be the most appropriate donor site for soft tissue grafting procedure. The measurement of the thickness of palatal masticatory mucosa by using computerized tomography can offer useful information clinically but further studies in as-sessing the validity and reliability of the method using computerized tomography is needed.

건강한 한국 성인에서 경구개와 상악결절 부위 저작점막의 두께 측정 (The Thickness Measurement of Masticatory Mucosa on the Hard Palate and Maxillary Tuberosity in Healthy Korean Adults)

  • 조익현;박정미;장문택;김형섭;김현철
    • Journal of Periodontal and Implant Science
    • /
    • 제31권3호
    • /
    • pp.641-649
    • /
    • 2001
  • The aim of present study was to assess the thickness of masticatory mucosa on the hard palate and tuberosity as a potential donor site for mucogingival surgery. Thickness measurement was performed in 30 dental college students who are periodontally healthy, with a recently developed, ultrasonic device(SDM). The mean age of study subjects was 23.7(range 21-29) years old and the subjects were composed of 18 males and 12 females. Eighteen standard measurement points were defined on the hard palate, located on 3 lines which ran at different distances parallel to the gingival margin. Six positions were designated on each of these 3 lines between the level of the canine and the second molar. On the tuberosity, 6 standard measurement points were defined, located on 2 lines running parallel to the gingival margin at different distances. Data were analyzed to determine differences in gender, between different positions, and between lines, by an analysis of variance. The results showed that the mucosa of the tuberosity was significantly thicker than that of the hard palate region. Gender did not influence the thickness of masticatory mucosa, either on the hard palate or the tuberosity. On the hard palate, mucosa thickness increased as the distance from the marginal gingiva increased. The mucosa over the palatal root of the maxillary first molar was significantly thinner than that at all other positions on the hard palate. Measurement error at palate was 0.25mm, at tuberosity 0.51mm. No difference in the thickness of masticatory mucosa on palate and tuberosity was found between men and women. On the hard palate, soft tissue thickness progressively increased in sites further from the gingival margin. Therefore, we may harvest more thicker graft on the tuberosity that has more masticatory mucosa thickness than hard palate, however the width may not be sufficient for using.

  • PDF

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;최대균
    • 대한치과보철학회지
    • /
    • 제36권2호
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구 (A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE)

  • 권긍록;박남수;최대균
    • 대한치과보철학회지
    • /
    • 제34권3호
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구 (A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS)

  • 백진;박남수
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF

완전 무치악 환자에서 하악 흡착 의치를 통한 총의치 수복 증례 (Complete denture rehabilitation of edentulous patient using mandibular suction denture: a clinical report)

  • 임서련;서윤희;김현영;송영균;이준석
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.346-351
    • /
    • 2014
  • 흡착 의치는 의치상연 주위 전체를 가동 점막으로 봉쇄하여 연하나 교합 시 의치상 내면에 일시적으로 음압을 형성하여 의치의 유지와 안정을 강화한다. 본 증례의 환자는 81세의 남자 환자로 새로운 의치를 제작하고 싶다는 주소로 내원하였다. 의치의 유지와 저작 효율에 대한 환자의 높은 요구도를 고려하여 흡착 의치를 통한 총의치 제작을 계획하였다. 하악 후구치 융기 부위를 가압하지 않은 채로 예비 인상을 채득 후 상하악 진단모형을 제작하였다. 이후 개인 트레이 제작 후 최종 인상 채득과 동시에 고딕 아치 기록을 시행하여 중심위 및 수직 고경을 채득하였으며, 상악에는 해부학적 치아, 하악에는 비해부학적 치아를 배열하여 설측 교합을 형성하였다. 이상과 같이 완전 무치악 환자에서 하악 흡착 의치를 통한 총의치 수복은 만족스러운 유지와 기능을 회복할 수 있었기에 본 증례를 보고하고자 한다.