• Title/Summary/Keyword: master file

검색결과 63건 처리시간 0.027초

Ubiquitous Workspace Synchronization in a Cloud-based Framework (클라우드 기반 프레임워크에서 유비쿼터스 워크스페이스 동기화)

  • Elijorde, Frank I.;Yang, Hyunho;Lee, Jaewan
    • Journal of Internet Computing and Services
    • /
    • 제14권1호
    • /
    • pp.53-62
    • /
    • 2013
  • It is common among users to have multiple computing devices as well as to access their files or do work at different locations. To achieve file consistency as well as mobility in this scenario, an efficient approach for workspace synchronization should be used. However, file synchronization alone cannot guarantee the mobility of work environment which allows activities to be resumed at any place and time. This paper proposes a ubiquitous synchronization approach which provides cloud-based access to a user's workspace. Efficient synchronization is achieved by combining session monitoring with file system management. Experimental results show that the proposed mechanism outperforms Cloud Master-replica Synchronization in terms of number of I/O operations, CPU utilization, as well as the average and maximum latencies in responding to client requests.

A Bilateral Teleoperation Control Scheme for 2-DOF Manipulators with High Reduction Ratio Joints

  • Ahn, Sung-Ho;Yoon, Ji-Sup;Lee, Sang-Jeong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.519-519
    • /
    • 2000
  • Since the dynamics of the slave manipulator with high reduction ratio joints is likely to be much slower than that of the master manipulator, the control input the slave manipulator is so frequently saturated. This paper proposes a bilateral teleoperation control scheme for 2-DOF manipulators with high reduction ratio joints, which can effectively compensate the control input saturation. In the proposed scheme, the controllers of the slave manipulator are designed with an anti-windup feature and forces caused by the saturation are reflected to the operator holding the operating handle of the master manipulator. When the control input of the slave manipulator is saturated, the master manipulator moves slowly file to tile reflected forces. In this way, the position tracking performance of the slave manipulator with high reduction ratio joints can be enhanced regardless of saturation. The proposed scheme is shown to give excellent position tracking performance through a series of experiments.

  • PDF

An Analysis of the Structural Characteristics of the UDC Standard Edition (UDC 표준판의 구조적 특성 분석)

  • Lee, Chang-Soo
    • Journal of Korean Library and Information Science Society
    • /
    • 제39권3호
    • /
    • pp.299-320
    • /
    • 2008
  • This study examined the historical background and structural characteristics of the UDC(Universal Decimal Classification) standard edition which has been created from the entire content of the Master Reference File database. We made a comparison of the structural characteristics between UDC standard edition and Korean abridged edition. UDC is a hybrid of two kinds of documentary classification scheme, that is enumerative and analytico-synthetic, and its structure reflects this feature. It is found that UDC standard edition extended the universality and synthetic method using its auxiliary tables compare to Korean abridged edition.

  • PDF

Application of Group Master Cache for the Integrated Environment of SAN and NAS (Group Master Cache를 활용한 SAN과 NAS의 통합 방안)

  • Lee, Won-Bok;Park, Jin-Won
    • Journal of the Korea Society for Simulation
    • /
    • 제16권2호
    • /
    • pp.9-15
    • /
    • 2007
  • As the Internet grows and the mass multimedia data become popular, the storage system migrates from DAS, where the storage and the server are directly connected, to SAN and NAS. SAN connects the storages with a separate network, and NAS provides only file services, connects the storages with IP network. However, SAN and NAS can not fulfill the needs for companies if used separately, thus are asked to be integrated. In this research, we propose an efficient data sharing method which employees the concept of GMC, Croup Master Cache for the integrated environment of SAN and NAS. GMC is based on MCI, Metadata server and Cluster system Integration, but tries to solve the high expansion cost problem with MCI. We introduce the basic concept of GMC, compare the performance of GMC with that of MCI using computer simulation.

  • PDF

Evaluation of apical canal shapes produced sequentially during instrumentation with stainless steel hand and Ni-Ti rotary instruments using micro-computed tomography

  • Lee, Woo-Jin;Baek, Seung-Ho;Bae, Kwang-Sik
    • Proceedings of the KACD Conference
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.597-598
    • /
    • 2003
  • I. Objectives Endodontic success depends on thoroughly cleaned and completely obturated root canal system. Effective cleaning and obturation will be achieved by well shaped canal. Numerous methodologies evaluating the efficacy and safety of canal preparation has been developed and the use of micro-computed tomography(MCT) in endodontic research is one of the latest innovations. This scientific tools could overcome the inherent limitations of other methodologies, and possesses the ability to visualize morphological characteristics in a detailed and accurate manner without destruction of the tooth and offers reproducible data in all three dimensions. The purpose of this study was to determine the optimal master apical file size with less transportation and more efficiency in removing the infected dentin. For this purpose we evaluated the transportation of canal center and change of untouched area after preparation sequentially from #25 file through #40 file with 3 different instruments:Stainless steel(SS) K-type hand instruments(MANI, Japan), ProFile.04 instruments (Dentply Tulsa Dental, USA) and Lightspeed instruments(Lightspeed Technology, San Antonio, USA) using micro-computed tomography.(omitted)

  • PDF

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

EFFECTIVENESS OF CUSTOMIZED MASTER CONE ON APICAL SEALING IN VARIOUS APICAL SIZE OF PREPARED ROOT CANALS (근단부 크기에 따른 customized master cone의 치근단 밀폐효과에 관한 연구)

  • Hong, Hye-Young;Choi, Ho-Young;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • 제27권1호
    • /
    • pp.66-76
    • /
    • 2002
  • The purpose of this study is to evaluate the effectiveness of customized master cone on apical sealing in various apical size of prepared root canals, that is MAF(Master Apical File) and to know at which apical size the apical leakage is to be significantly reduced using customized master cone. 120 extracted single rooted premolars were divided into four groups according to their apical size(MAF), #30, 40, 50 and 60. And then, each group was subdivided into three in accordance with three obturation methods, lateral condensation with standardized master cone, lateral condensation with chloroform-dipped customized master cone, and continuous wave of obturation technique. Resorcinol-formaldehyde resin was used for the microleakage test of this study. Teeth were sectioned horizontally at 1.5mm(Level 1), 2.5mm(Level 2), and 3.5mm(Level 3) from the anatomical root apex using low speed microtome. All sections were examined under $\times$40 magnification with a stereomicroscope, photographed, and then scanned. With the scanned images, resin-infiltrated area presenting the microleakage was calculated using SigmaScan/Image, and the ratio of leakage to the total root canal area of each group was analyzed statistically(one way ANOVA). The results were as follows ; 1. In groups of MAF #30, there was no significant difference of mean leakage ratio among three obturation methods at all three levels. 2. In groups of MAF #40, the group using lateral condensation with customized master cone had the low-est mean leakage ratio at all three levels, but there was no significant difference among three obturation techniques. 3. In groups of MAF #50, the mean leakage ratio of the group using lateral condensation with standard master cone was the highest among those of three obturation techniques at level 1, and this difference was statistically significant(p<0.05). 4 In groups of MAF #60, the groups using lateral condensation with standard master cone had also the highest mean leakage ratio at all levels, but there was no significant difference at level 1 and 2. At level 3, the leakage of the group using lateral condensation with standard master cone was significantly higher than that of the group using continuous wave of obturation(p<0.05). The results of this study suggested that the obturation method using customized master cone or the continuous wave of obturation is more effective for apical sealing than that using standardized master cone when MAF is larger than #50.

Calculated Critical Masses for Spherical Plutonium Core with Various Spherical Reflectors

  • Kim, Dong-Hoon
    • Nuclear Engineering and Technology
    • /
    • 제4권4호
    • /
    • pp.273-279
    • /
    • 1972
  • Requirements necessary for the construction of a fast critical assembly in this country are briefly reviewed. The critial masses of a spherical plutonium core with various spherical reflectors and its thicknesses are calculated using IDX, which is a computer code written for fast reactor analysis. The compilation of this code was made on CDC 3300/Master and UNIVAC 1106/EXEC 8. The calculated results are completely depicted, and compared with other results in this report. The Russian formatted 29 group cross section set generated by ETOX-2 using ENDF/B Version II file at Hanford is used in the calculations.

  • PDF

Accuracy of implant digital scans with different intraoral scanbody shapes and library merging according to different oral exposure height (구내 스캔바디의 형태에 따른 임플란트의 디지털 스캔 정확도 및 구강 내 노출 높이에 따른 라이브러리 중첩 정확도 비교 연구)

  • Jeong, Byungjoon;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제59권1호
    • /
    • pp.27-35
    • /
    • 2021
  • Purpose: The purpose of this study is to compare the accuracy of digital scans of implants according to different shapes of scanbodies, and to compare the accuracy of library merging according to different oral exposure height. Materials and methods: A master model with a single tooth edentulous site was prepared. For the first experiment, three types of intraoral scanbodies were prepared, divided into three groups, and the following experiments were conducted for each group: An internal hex implant was placed. The master model with the scanbody connected was scanned with a model scanner, and a master reference file (control group) was created. 10 files (experimental group) were created by performing 10 consecutive scans with an intraoral scanner. After superimposing the control and experimental groups, the following values were calculated: 1) Distance deviation of a designated point on the scanbody 2) Angle deviation of the major axis of the scanbody. For the second experiment, the scanbody scan data were prepared in 6 different heights. Library files were merged with each of the scan data. The distance and angular deviation were calculated using the 7 mm scan data as control group. Results: In the first experiment, there were no significant differences between A and B (P=.278), B and C (P=.568), and C and A (P=.711) in the distance deviations. There were no significant differences between A and B (P=.568), B and C (P=.546), and C and A (P=.112) in the angular deviations. Also, the scanbody showed significantly higher library merging accuracy in the groups with high oral exposure height (P<.5). Conclusion: There were no significant differences in scan accuracy according to the different shapes of scanbodies, and the accuracy of library merging increased according to exposure height of the scanbody in the oral cavity.

Healing of STEP AP214 Automotive CAD Data (STEP AP214 자동차 설계 데이터 정리 시스템)

  • 양정삼;한순흥
    • Korean Journal of Computational Design and Engineering
    • /
    • 제7권3호
    • /
    • pp.170-176
    • /
    • 2002
  • To exchange CAD data between heterogeneous CAD systems, we generally use a neutral format especially STEP, which is the international standard (ISO-10303) for product model data exchange. AP214 (Application Protocol) for the automotive industry not only takes into account geometry and organizational data, but also provides a classification mechanism for product modeling. When reading a STEP file during a design process that is exported from other CAD systems, it is a burden to a designer to go through the tedious process of removing duplicate or non-manifold entities, adjusting parts, and rearranging text. We analyze the structure of AP214 and develop a healing tool to solve the following problem. Without the assembly information in the Master workspace of CATIA, or to read a STEP file from Pro/Engineer, a designer should do a repetitive process of disintegrating an assembly into parts one by one. We have developed a post-processing tool for STEP AP214 that separates out a part from an assembly model and adjusts superfluous or useless entities using the ACIS kernel.