• Title/Summary/Keyword: mass operator

Search Result 72, Processing Time 0.341 seconds

Simulation of Multiple Steam Generator Tube Rupture (SGTR) Event Scenario

  • Seul Kwang Won;Bang Young Seok;Kim In Goo;Yonomoto Taisuke;Anoda Yoshinari
    • Nuclear Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.179-190
    • /
    • 2003
  • The multiple steam generator tube rupture (SGTR) event scenario with available safety systems was experimentally and analytically evaluated. The experiment was conducted on the large scaled test facility to simulate the multiple SGTR event and investigate the effectiveness of operator actions. As a result, it indicated that the opening of pressurizer power operated relief valve was significantly effective in quickly terminating the primary-to-secondary break flow even for the 6.5 tubes rupture. In the analysis, the recent version of RELAP5 code was assessed with the test data. It indicated that the calculations agreed well with the measured data and that the plant responses such as the water level and relief valve cycling in the damaged steam generator were reasonably predicted. Finally, sensitivity study on the number of ruptured tubes up to 10 tubes was performed to investigate the coolant release into atmosphere. It indicated that the integrated steam mass released was not significantly varied with the number of ruptured tubes although the damaged steam generator was overfilled for more than 3 tubes rupture. These findings are expected to provide useful information in understanding and evaluating the plant ability to mitigate the consequence of multiple SGTR event.

Numerical and experimental study on dynamic response of moored spar-type scale platform for floating offshore wind turbine

  • Choi, E.Y.;Cho, J.R.;Cho, Y.U.;Jeong, W.B.;Lee, S.B.;Hong, S.P.;Chun, H.H.
    • Structural Engineering and Mechanics
    • /
    • v.54 no.5
    • /
    • pp.909-922
    • /
    • 2015
  • The dynamic response and the mooring line tension of a 1/75 scale model of spar-type platform for 2.5 MW floating offshore wind turbine subject to one-dimensional regular harmonic wave are investigated numerically and verified by experiment. The upper part of wind turbine which is composed of three rotor blades, hub and nacelle is modeled as a lumped mass the scale model and three mooring lines are pre-tensioned by means of linear springs. The coupled fluid-rigid body interaction is numerically simulated by a coupled FEM-cable dynamics code, while the experiment is performed in a wave tank with the specially-designed vision and data acquisition system. The time responses of surge, heave and pitch motions of the scale platform and the mooring line tensions are obtained numerically and the frequency domain-converted RAOs are compared with the experiment.

Development of Feed Controller Using Synchronization Algorithm (동기화 알고리즘을 이용한 피드컨트롤러 개발)

  • Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.19 no.4
    • /
    • pp.162-166
    • /
    • 2018
  • Companies that use automatic feeder systems use multiple feeders in close proximity to each other for mass production. Unlike when the feeder is used independently, it does not oscillate to a value that is set to offset or freeze due to symbiosis caused by asynchronous forces hitting each other. This may result in the shipment being damaged by hitting each other or thrown to one side, preventing the transport from being moved to the next process. Whenever an unstable resonance occurs, the operator must reset the value of each feed controller or operate it several times. To address these problems, this paper proposes synchronization algorithm suitable for feed controllers using multiple units and tests are used to confirm performance improvements.

A Study of a Hydraulic Excavator's Test to Verify of Payload Estimation by Bucket's Motion Equation (유압 굴착기 실험을 통한 작업량 추정법 확인에 관한 연구)

  • Jeong, Hwang Hun;Lee, Min Su;Shin, Young Il
    • Journal of Drive and Control
    • /
    • v.19 no.2
    • /
    • pp.11-16
    • /
    • 2022
  • It is important to measure the excavator's work productivity that estimates the bucket's payloads on a process. If the bucket isn't filled at every working cycle, the excavator's operator has to drive the machine more to achieve his work quota. If bucket is filled over with the load, the other way around, the transferred object has to spread out on the workplace. That causes additional work to clean the site. This paper proposes a method that can estimate the bucket's payload to improve the excavator's work productivity. This method assumes that the excavator is a lumped mass system. And it uses a 3 points angle (boom link, arm link, swing) and 2 points pressure (boom cylinder's input port and output port) of measurable data. Depending on assumptions, the bucket's payload can be calculated by the payload's motion equation. And this suggested method can be verified by simple experiments.

Comparing validity of using Body Mass Index, Waist to Hip Ratio, and Waist Circumference to Cardiovascular Risk Factors of Middle Aged Koreans (한국중년층에서 체질량지수, 허리-엉덩이둘레비, 및 허리둘레의 심장혈관계질환 위험인자 타당도 비교)

  • Mun, Hyeon-Gyeong;Kim, Yu-Jin
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.3
    • /
    • pp.365-374
    • /
    • 2005
  • This study was conducted to compare the validity of obese index among body mass index(BMI), waist to hip ratio(WHR), and waist circumference(WC) and to determine which is the best in relation to cardiovascular risk factors of middle aged Korean(40-64yr).Data from the 1998 Korean Health and Nutrition Survey were used(N=3380). Anthropometric indices and cardiovascular risk factors were measured. Chi-square test, analysis of variance following duncan's multiple range test, partial correlation analysis, and Receiver Operator characteristic(ROC) curves were used in the analysis. There was a significant increasing trend in WHR, systolic blood pressure(SBP), high density lipoprotein cholesterol(HDL), and fasting blood sugar(FBS) with age categories of male and in BMI, WC, WHR, diastolic blood pressure(DBP), SBP, total cholesterol(TC), low density lipoprotein cholesterol(LDL), triglycerol(TG), and FBS with those of female. Specially female had the characteristics of upper body fat and systolic blood pressure risk(p<0.05). Proportions of subjects with lifestyle factors related to cardiovascular risk in overweight or upper body fat group were higher than that of normal group. Higher proportions of subjects were practiced exercise in upper body fat group of male than in other groups. Among 7 cardiovascular risk factors in partial correlation analysis, BMI had the highest correlation coefficient in 6 risk factors in male, whereas WC in 4 risk factors in female. Mean of each obese index according to cardiovascular risk groups except smoker was higher than that of normal(p<0.05). These trends were shown in upper body fat group and female. In ROC analysis of 12 risk factors and health conditions, the largest area under curve among obese indices for risk factors were BMI in male and WHR in female. The optimal cutoff values of each index(BMI: WHR: WC) for one or more cardiovascular risk factors were 23.13: 0.89: 85.35 in male and 23.57: 0.84: 78.35 in female. The results showed that cardiovascular risk factors were prevalent in middle aged Koreans within normal limits of obese indices like another Asians. For the identification of cardiovascular risk factors of middle aged Koreans, BMI for men and WHR for women are appropriate indices. But it is recommended that BMI, WHR, and WC, all three indices should be considered, when using these indices.

  • PDF

Application of Point Shearwave Elastography to Breast Ultrasonography: Initial Experience Using "S-Shearwave" in Differential Diagnosis (Point Shearwave Elastography의 유방 초음파에서의 적용: "S-Shearwave"를 이용한 감별진단의 초기경험)

  • Myung Hwan Lee;Eun-Kyung Kim;Eun Ju Lee;Ha Yan Kim;Jung Hyun Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.157-165
    • /
    • 2020
  • Purpose To evaluate the optimal measurement location, cut-off value, and diagnostic performance of S-Shearwave in differential diagnosis of breast masses seen on ultrasonography (US). Materials and Methods During the study period, 225 breast masses in 197 women were included. S-Shearwave measurements were made by applying a square region-of-interest automatically generated by the US machine. Shearwave elasticity was measured three times at four different locations of the mass, and the highest shearwave elasticity was used for calculating the optimal cut-off value. Diagnostic performance was evaluated by using the area under the receiving operator characteristic curve (AUC). Results Of the 225 breast masses, 156 (69.3%) were benign and 69 (30.7%) were malignant. Mean S-Shearwave values were significantly higher for malignant masses (108.0 ± 70.0 kPa vs. 43.4 ± 38.3 kPa; p < 0.001). No significant differences were seen among AUC values at different measurement locations. With a cut-off value of 41.9 kPa, S-Shearwave showed 85.7% sensitivity, 63.9% specificity, 70.7% accuracy, and positive and negative predictive values of 51.7% and 90.8%, respectively. The AUCs for US and S-Shearwave did not show significant differences (p = 0.179). Conclusion S-Shearwave shows comparable diagnostic performance to that of grayscale US that can be applied for differential diagnosis of breast masses seen on US.

Pure additive contribution of genetic variants to a risk prediction model using propensity score matching: application to type 2 diabetes

  • Park, Chanwoo;Jiang, Nan;Park, Taesung
    • Genomics & Informatics
    • /
    • v.17 no.4
    • /
    • pp.47.1-47.12
    • /
    • 2019
  • The achievements of genome-wide association studies have suggested ways to predict diseases, such as type 2 diabetes (T2D), using single-nucleotide polymorphisms (SNPs). Most T2D risk prediction models have used SNPs in combination with demographic variables. However, it is difficult to evaluate the pure additive contribution of genetic variants to classically used demographic models. Since prediction models include some heritable traits, such as body mass index, the contribution of SNPs using unmatched case-control samples may be underestimated. In this article, we propose a method that uses propensity score matching to avoid underestimation by matching case and control samples, thereby determining the pure additive contribution of SNPs. To illustrate the proposed propensity score matching method, we used SNP data from the Korea Association Resources project and reported SNPs from the genome-wide association study catalog. We selected various SNP sets via stepwise logistic regression (SLR), least absolute shrinkage and selection operator (LASSO), and the elastic-net (EN) algorithm. Using these SNP sets, we made predictions using SLR, LASSO, and EN as logistic regression modeling techniques. The accuracy of the predictions was compared in terms of area under the receiver operating characteristic curve (AUC). The contribution of SNPs to T2D was evaluated by the difference in the AUC between models using only demographic variables and models that included the SNPs. The largest difference among our models showed that the AUC of the model using genetic variants with demographic variables could be 0.107 higher than that of the corresponding model using only demographic variables.

A Development of a Guiding System for the High-Speed Self-Align Cable Winding (고속 자동정렬 케이블 와인딩을 위한 가이딩 시스템 개발)

  • 이창우;강현규;지혁종;안영세;신기현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.478-482
    • /
    • 2002
  • Recently, the demand for the optical cable is rapidly glowing because the number of internet user increases and high speed internet data transmission is required. To meet this demand, it is necessary to have a sufficient manufacturing capability for mass and high-quality production. But the present optical cable winding system has some serious problems such that the optical cable of radius (6 mm -40 mm) is often piled up and collapsed usually at the edge of the bobbin in the process of the cable winding. It is often necessary to have an additional operator in order to adjust the cable, which causes the productivity decrease. In order to improve a performance of cable winding system which deals with relatively thick cable( radius : 6 mm -40 mm ), we developed a new guiding system for a high-speed self-align cable winding. First of all, the winding mechanism was analyzed. Synchronization logics for the motions of winding, traversing, and the guiding were created and implemented by using the PLC and guiding system controller in a prototype cable winding system manufactured in the CILS( Computer Integrated Large scale System ) lab. An experimental verification was carried out to validate the logic. Results showed that the winding system with the developed guiding system outperformed in reducing pile-up and collapse in the high-speed winding(up to 300 mm/s) compared with the system without the guiding system.

  • PDF

Measurement of Body Fat by Impedance Technique (임피던스 방법을 이용한 체지방 측정)

  • Kim, Deok-Won;Song, Chul-Gyu;Hwang, Soo-Kwan
    • Journal of Biomedical Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.133-140
    • /
    • 1992
  • Bioelectrical Impedance method for measuring human body composition is based upon the principle that the electrical conductivity of the fat-free mass (FFM) is far greater than that of the (at. Deter- mination o( impedance was nlade in 30 healthy and obese men aged $40.9{\pm}14.7$yr (mean${\pm}$SD) and 25 healthy and obese women aged $44.0{\pm}10.2$ yr. A commercial impedance body fat analyzer was used with a four electrode arrangement that introduced a painless constant current(ImA at 50 kHz) into the body. Linear relationships were found between impudence values and FFM(r=-0.786) and between weight and FFM(r=0.837). Signigicant increases in the correlation coefficients were ob served when the predicator Hta/z was regressed against FFM(r=0.912) where Ht Is height and Z Is impedance. A linear regression equation, FFM=0.586(Htf/z) +0.317(Weight) -1.674(r=0.977), was found. The correlation coefficient of % body fat between the impedance and infrared methods was 0.898. These data Indicate that the bioelectrical impedance technique is a reliable and valld approach for the estimation of human body composition. This method Is safe, noninvasivr, prouides rapld measure menu, requires little operator skill and subject cooperation, and Os portable. Finally measurement of percent body fat was made possible using both the regression equation and a developed impedance measuring device which measures impedance between wrist and ankle.

  • PDF

Application of fluorescent particles as a tracer to detect the membrane surface damage in a pilot scale membrane bioreactor (형광입자를 이용한 분리막 표면 검측 방법의 파일럿 규모 플랜트 적용)

  • Kim, Choah;Kim, Hee Jun;Cho, Jinwoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.33-40
    • /
    • 2016
  • In this study, a fluorescent silica nano particle is used as the surrogate for challenging test of membrane surface integrity. The particles are functionalized by a fluorescent dying agent so that as an ultraviolet light is imposed a bright fluorescent image from the particles can be taken. If a membrane surface is damaged and has a compromised part larger than the size of surrogate the fluorescent particles would pass through and contained in the permeate. An operator can directly notice whether the membrane surface is damaged or not by detecting a fluorescent image taken from the permeate. Additionally, the size of compromised part is estimated through analysing the fluorescent image in which we surmise the mass of particles included in the permeate by calculating an average RGB value of the image. The pilot scale experiments showed that this method could be applied successfully to determine if a membrane surface had a damaged parts regardless of the test condition. In the testing on the actual damaged area of $4.712mm^2$, the lowest error of estimating the damaged area was -1.32% with the surrogate concentration of 80 mg/L, flux of $40L/m^2/hr$ for 25 minutes of detection. A further study is still going on to increase the lowest detection limit and thus decrease the error of estimation.