• Title/Summary/Keyword: marginal effect

Search Result 527, Processing Time 0.027 seconds

Effect of cement space on marginal and internal fit of a zirconia core fabricated using by additive manufacturing (시멘트 공간이 적층 가공으로 제작한 지르코니아 하부구조물의 변연 및 내면 적합도에 미치는 영향)

  • Ji-Won Min;Se-Yeon Kim;Jae-Hong Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Purpose: The goal of this study was to determine the clinical acceptability of various cement space settings for the marginal and internal fit of a zirconia core manufactured using additive manufacturing. Methods: The maxillary right incisor served as the master model. After scanning the maxillary right incisor with a dental 3D (three-dimensional) scanner, the stereo lithography file was created using different cement space settings of 40, 120, and 200 ㎛ using computer-aided design software (Dental System 2018; 3Shape). The marginal and internal fit of the 3 groups were determined using the silicon replica technique. Measurement points were divided into the following three categories: margin, axial wall, and incisal. To ensure more accurate measurements, these three measurement points were divided into 8 points. The Shapiro-Wilk, one-way ANOVA, and Tukey's honestly significant difference test (for all tests α=0.05) were the statistical analyses that were included in the study. Results: The CS (cement space)-200 group had better marginal and internal fit than the CS-40 and CS-120 groups, and there were statistically significant differences at the marginal and incisal points, except for the axial wall points. CS-200 group, both marginal and internal fit were within 120 ㎛, which is the clinically acceptable value. Conclusion: This study suggests that a 200 ㎛ cement space setting is ideal for optimal marginal and internal fit of 3D-printed ceramic crowns.

Effects of Some Liming Materials Application on the Alleviation of the Symptoms of Mn Toxicity Inculding Marginal Leaf Chlorosis (석회류제의 시용이 엽연형 황피발생 억제에 미치는 영향)

  • Lee, Tae-Su;Kim, Myeong-Su;Hong, Sun-Geun
    • Journal of Ginseng Research
    • /
    • v.14 no.1
    • /
    • pp.44-49
    • /
    • 1990
  • Effect of liming material application on the prevention or cure of Mn toxicity symptoms including marginal leaf chlorosis in 3-year-old ginseng plants grown in acidic soils were investigated. It was found that the ratio of Fe to Mn was above about 0.5 and the ratio of Mn to Fe was below about 2.00 in 4-year old ginseng leaves when liming materials were applied in field experiments. It was apparent that the occurrence of marginal leaf chlorosis was decreasing affected by application of Ca, Mg and Fe. The appearance of marginal leaf chlorosis was decreased to about 78 percent in 4-year-old ginseng and to about 69 percent in 5-year-old ginseng, and then the fresh root weight was increased up to 66 percent in 4-year ginseng plants.

  • PDF

Effect of Dietary Fat and Marginal Tocopherol Supplement on Plasma Lipid, Tocopherol Contet and Fatty acid Composition of Rat Tissues (식이지방과 Tocopherol 첨가가 혈액의 지질 및 조직의 Tocopherol 함량과 지방산조성에 미치는 영향)

  • 남정혜
    • Journal of Nutrition and Health
    • /
    • v.19 no.5
    • /
    • pp.304-314
    • /
    • 1986
  • To observe the effect of the different level of PUFA and marginal tocopherol supplement on HDL-chol, tissue tocopherol content and fatty acid composition, the rats were supplied either safflower oil or conconut oil with or without tocopherol supplement to the experimental diet. Plasma tocopherol level was not greatly influenced by the different dietary fat and similar effect was observed in the liver but not in the adipose tissue. HDL-chol level was reduced in the high PUFA diet regardless of tocopherol content. No effect by tocopherol supplement was observed in the fatty acid composition of liver and adipose tissue lipid in both dietary PUFA levels . There was also no increase in the content of tissue polyenoid acid by tocopherol in the high PUFA diet . Fatty acid composition of tissue lipid was rather more influenced by dietary fat. Lauric and myristic acid contents were higher in the low PUFA diet and linoleic acd and total polynoic acid content were higher in the high PUFA diet. With tocopherol supplement tocopherol /PUFA ratio of tissue was increased but the ratio of high PUFA diet was significantly lower than that of low PUFA diet. Marginal tocopherol supplement could not reduce the peroxidizability index of high PUFA diet.

  • PDF

Influence of crown-to-implant ratio on periimplant marginal bone loss in the posterior region: a five-year retrospective study

  • Lee, Kyung-Jin;Kim, Yong-Gun;Park, Jin-Woo;Lee, Jae-Mok;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.6
    • /
    • pp.231-236
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the influence of the crown-to-implant (C/I) ratio on the change in marginal bone level around the implant and to determine the site-related factors influencing the relationship between the C/I ratio and periimplant marginal bone loss. Methods: A total of 259 implants from 175 patients were evaluated at a mean follow-up of five years. Implants were divided into two groups according to their C/I ratios: ${\leq}$ 1, and >1. Site-related factors having an influence on the relationship between C/I ratio and periimplant marginal bone loss were analyzed according to the implant location, implant diameter, implant manufacturer, prosthesis type, and guided bone regeneration (GBR) procedure. Results: It was found that 1) implants with a C/I ratio below 1 exhibited greater periimplant marginal bone loss than implants with a C/I ratio more than 1, 2) site-related factors had an effect on periimplant marginal bone loss, except for the implant system used, 3) the C/I ratio was the factor having more dominant influence on periimplant marginal bone loss, compared with implant diameter, prosthesis type, implant location, and GBR procedure, 4) implants with a C/I ratio below 1 showed greater periimplant marginal bone loss than implants with a C/I ratio greater than 1 in the maxilla, but not in the mandible, 5) and periimplant marginal bone loss was more affected by the implant system than the C/I ratio. Conclusions: Within the limitations of this study, implants with a higher C/I ratio exhibited less marginal bone loss than implants with a lower C/I ratio in the posterior regions. The C/I ratio was a more dominant factor affecting periimplant marginal bone loss in the maxilla than the mandible. Meanwhile, the implant system was a more dominant factor influencing periimplant marginal bone loss than the C/I ratio.

A Case Report on Extranodal Marginal Zone B Cell of Mucosa-associated Lymphoid Tissue (MALT) Type Lymphoma Treated with Hangam-dan (항암단을 투여 받은 림프절 외 변연부 B세포 림프종 환자에 대한 증례보고)

  • Han, Sung-Soo;Cho, Chong-Kwan;Lee, Yeon-Weol;Yoo, Hwa-Seung
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.810-818
    • /
    • 2008
  • Objective : The aim of this case report is to drive further studies evaluating the effectiveness of Korean oriental medicine on extranodal marginal zone B cells of MALT (mucosa-associated lymphoid tissue) type lymphoma. Methods : This case report is about a patient who was diagnosed with extranodal marginal zone B cell of MALT type lymphoma, who refused chemotherapy and preferred to be treated with Korean oriental medicine. Neck, chest abdomen & pelvis with enhanced computed tomography (CT) and positron emission tomography computed tomography (PET-CT) were performed to evaluate the anticancer effect of Hangam-dan (HAD). Results : The patient diagnosed with MALT showed partial response after receiving 17 months of Korean oriental medical treatment. Neck, chest, abdomen & pelvic CT and PET-CT show decrease in size. Conclusion : This case report shows a possibility that Korean oriental treatment could offer potential benefits for patients with extranodal marginal zone B cell of MALT type lymphoma.

  • PDF

Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods

  • Kaleli, Necati;Ural, Cagri;Us, Yesim Olcer
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.124-130
    • /
    • 2020
  • PURPOSE. The aim of this in vitro study was to evaluate the effect of sintering procedures on marginal discrepancies of fixed partial metal frameworks fabricated using different sintering-based computer-aided design and computer/aided manufacturing (CAD/CAM) techniques. MATERIALS AND METHODS. Forty resin die models of prepared premolar and molar abutment teeth were fabricated using a three-dimensional (3D) printer and divided into four groups (n = 10) according to the fabrication method of metal frameworks used: HM (via hard milling), SM (via soft metal milling), L25 (via direct metal laser melting [DMLM] with a 25 ㎛ layer thickness), and L50 (via direct DMLM with a 50 ㎛ layer thickness). After the metal frameworks were fabricated and cemented, five vertical marginal discrepancy measurements were recorded in each site (i.e., buccal, facing the pontic, lingual, and facing away from the pontic) of both abutment teeth under a stereomicroscope (×40). Data were statistically analyzed at a significance level of 0.05. RESULTS. No statistically significant differences (P>.05) were found among the four axial sites of metal frameworks fabricated by sintering-based CAD/CAM techniques. The HM and L25 groups showed significantly (P<.001) lower marginal discrepancy values than the SM and L50 groups. CONCLUSION. Marginal discrepancy in the sites facing the pontic was not influenced by the type of sintering procedure. All fabrication methods exhibited clinically acceptable results in terms of marginal discrepancies.

Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems

  • Ha, Seok-Joon;Cho, Jin-Hyun
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.6
    • /
    • pp.439-448
    • /
    • 2016
  • PURPOSE. The purposes of this study are to evaluate the internal and marginal adaptation of two widely used CAD/CAM systems and to study the effect of porcelain press veneering process on the prosthesis adaptation. MATERIALS AND METHODS. Molar of a lower jaw typodont resin model was prepared by adjusting a 1.0 mm circumferential chamfer, an occlusal reduction of 2.0 mm, and a $5^{\circ}$ convergence angle and was duplicated as an abrasion-resistant master die. The monolithic crowns and copings were fabricated with two different CAD/CAM system-Ceramil and Zirkonzahn systems. Two kinds of non-destructive analysis methods are used in this study. First, weight technique was used to determine the overall fitting accuracy. And, to evaluate internal and marginal fit of specific part, replica technique procedures were performed. RESULTS. The silicone weight for the cement space of monolithic crowns and copings manufactured with Ceramil system was significantly higher than that from Zirkonzahn system. This gap might cause the differences in the silicone weight because the prostheses were manufactured according to the recommendation of each system. Marginal discrepancies of copings made with Ceramil system were between 106 and $117{\mu}m$ and those from Zirkonzahn system were between 111 and $115{\mu}m$. Marginal discrepancies of copings made with Ceramil system were between 101 and $131{\mu}m$ and those from Zirkonzahn system were between 116 and $131{\mu}m$. CONCLUSION. Marginal discrepancy was relatively lower in Ceramil system and internal gap was smaller in Zirkonzahn system. There were significant differences in the internal gap of monolithic crown and coping among the 2 CAD/CAM systems. Marginal discrepancy produced from the 2 CAD/CAM systems were within a reported clinically acceptable range of marginal discrepancy.

INFLUENCE OF LOW-INTENSITY CURING AND POLISHING PERIOD ON MARGINAL LEAKAGE OF COMPOSITE (광중합형 레진에서 초기 저광도 광중합 및 연마 시기가 변연부 미세 누출에 미치는 영향)

  • Lee, Sang-Hoon;Jeong, Il-Young;Roh, Byoung-Duck
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.85-90
    • /
    • 2000
  • For more esthetic treatments the use of composite in molar areas are increasing. But polymerzation shrinkage that cause marginal leakage and cuspal deflection has been the problems of composites. The purpose of this study is to compare the effect of low intensity curing and polishing period on marginal leakage. Cavities were prepared on the buccal or lingual surface of forty five sound extracted human teeth and etching, application of bonding agent and filling of composite was done. Group 1 was light cured at intensity of 600$mW/cm^2$ for 41 seconds and polished. Group 2 was light cured at intensity of 300$mW/cm^2$ for 2 seconds and polished and after polishing it was light cured for 40 seconds at 600$mW/cm^2$. Group 3 was light cured at intensity of 300$mW/cm^2$ for 2 seconds and waited for 5 minutes and after curing at 600$mW/cm^2$ for 40 seconds polishing was done. The specimens were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles and immersed in 2% methylene blue solution for 24 hours. Composite-tooth interface was examined under stereobinocular microscope for dye penetration. The results were as follows : 1. Group which were cured at low intensity and polished after curing at high intensity showed less marginal leakage than group which were cured at high intensity for 41 seconds(p<0.05). 2. Marginal leakage between group which were cured at low intensity and polished immediately and group which were cured at high intensity for 41 second were not significantly different. Light curing at low intensity can reduce marginal leakage but polishing immediately after curing at low intensity for short time can affect marginal leakage.

  • PDF

Long-term effect of implant-abutment connection type on marginal bone loss and survival of dental implants

  • Young-Min Kim;Jong-Bin Lee;Heung-Sik Um;Beom-Seok Chang;Jae-Kwan Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.496-508
    • /
    • 2022
  • Purpose: This study aimed to compare the long-term survival rate and peri-implant marginal bone loss between different types of dental implant-abutment connections. Methods: Implants with external or internal abutment connections, which were fitted at Gangneung-Wonju National University Dental Hospital from November 2011 to December 2015 and followed up for >5 years, were retrospectively investigated. Cumulative survival rates were evaluated for >5 years, and peri-implant marginal bone loss was evaluated at 1- and 5-year follow-up examinations after functional loading. Results: The 8-year cumulative survival rates were 93.3% and 90.7% in the external and internal connection types, respectively (P=0.353). The mean values of marginal bone loss were 1.23 mm (external) and 0.72 mm (internal) (P<0.001) after 1 year of loading, and 1.20 mm and 1.00 mm for external and internal abutment connections, respectively (P=0.137) after 5 years. Implant length (longer, P=0.018), smoking status (heavy, P=0.001), and prosthetic type (bridge, P=0.004) were associated with significantly greater marginal bone loss, and the use of screw-cement-retained prosthesis was significantly associated (P=0.027) with less marginal bone loss. Conclusions: There was no significant difference in the cumulative survival rate between implants with external and internal abutment connections. After 1 year of loading, marginal bone loss was greater around the implants with an external abutment connection. However, no significant difference between the external and internal connection groups was found after 5 years. Both types of abutment connections are viable treatment options for the reconstruction of partially edentulous ridges.

Influence of final crystallization process on precision of fit of monolithic CAD/CAM-generated restorations by lithium disilicate: A comparative study (리튬 디실리케이트 최종 결정화 과정이 CAD/CAM으로 제조된 수복물의 적합도에 미치는 영향)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.4
    • /
    • pp.271-278
    • /
    • 2019
  • Purpose: To quantify the effect of the crystallization process on lithium disilicate ceramic crowns that are fabricated using a computer-aided design/computer-aided manufacturing(CAD/CAM) system, and to determine whether they are clinically acceptable by comparing values before and after the crystallization process. Methods: The maxillary first molar was selected as the abutment for the experiments. Ten working models were prepared. Marginal and internal gap of 4 groups of lithium disilicate crowns(n=10) fabricated with conventional method. Comparison was performed using the silicone replica technique and 3D superimposition analysis. The marginal and internal gaps of the restoration were measured before and after the crystallization process of this prosthesis. The average value of each part(the average of values measured before and after the crystallization) was statistically analyzed using paired t-test(α=0.05). Results: The results from the second phase of this research, which compared the average value of the gap between the marginal and internal fits of the lithium disilicate single crown before and after the crystallization process, indicated that the marginal gap was larger and the internal gap was smaller after the crystallization process, and this difference was statistically significant (P<0.05) in all the parts evaluated. Conclusion: While the shrinkage that occurs during crystallization does affect the marginal and internal fit of the prosthesis, it cannot be concluded to be a major effect because the resultant distortion was within the clinically acceptable range.