• Title/Summary/Keyword: marA

Search Result 861, Processing Time 0.027 seconds

Effect of cone-beam computed tomography metal artefact reduction on incomplete subtle vertical root fractures

  • Andrea Huey Tsu Wang;Francine Kuhl Panzarella;Carlos Eduardo Fontana;Jose Luiz Cintra Junqueira;Carlos Eduardo da Silveira Bueno
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.11-19
    • /
    • 2023
  • Purpose: This study compared the accuracy of detection of incomplete vertical root fractures (VRFs) in filled and unfilled teeth on cone-beam computed tomography images with and without a metal artefact reduction (MAR) algorithm. Materials and Methods: Forty single-rooted maxillary premolars were selected and, after endodontic instrumentation, were categorized as unfilled teeth without fractures, filled teeth without fractures, unfilled teeth with fractures, or filled teeth with fractures. Each VRF was artificially created and confirmed by operative microscopy. The teeth were randomly arranged, and images were acquired with and without the MAR algorithm. The images were evaluated with OnDemand software (Cybermed Inc., Seoul, Korea). After training, 2 blinded observers each assessed the images for the presence and absence of VRFs 2 times separated by a 1-week interval. P-values<0.05 were considered to indicate significance. Results: Of the 4 protocols, unfilled teeth analysed with the MAR algorithm had the highest accuracy of incomplete VRF diagnosis (0.65), while unfilled teeth reviewed without MAR were associated with the least accurate diagnosis (0.55). With MAR, an unfilled tooth with an incomplete VRF was 4 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition, while without MAR, an unfilled tooth with an incomplete VRF was 2.28 times more likely to be identified as having an incomplete VRF than an unfilled tooth without this condition. Conclusion: The use of the MAR algorithm increased the diagnostic accuracy in the detection of incomplete VRF on images of unfilled teeth.

Vertical root fracture diagnosis in teeth with metallic posts: Impact of metal artifact reduction and sharpening filters

  • Debora Costa Ruiz;Lucas P. Lopes Rosado;Rocharles Cavalcante Fontenele;Amanda Farias-Gomes;Deborah Queiroz Freitas
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.139-145
    • /
    • 2024
  • Purpose: This study examined the influence of a metal artifact reduction (MAR) tool, sharpening filters, and their combination on the diagnosis of vertical root fracture (VRF) in teeth with metallic posts using cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human premolars - 9 with VRF and 11 without - were individually placed in a human mandible. A metallic post composed of a cobalt-chromium alloy was inserted into the root canal of each tooth. CBCT scans were then acquired under the following parameters: 8 mA, a 5×5 cm field of view, a voxel size of 0.085 mm, 90 kVp, and with MAR either enabled or disabled. Five oral and maxillofacial radiologists independently evaluated the CBCT exams under each MAR mode and across 3 sharpening filter conditions: no filter, Sharpen 1×, and Sharpen 2×. The diagnostic performance was quantified by the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. These metrics were compared using 2-way analysis of variance with a significance level of α=5%. Intra- and inter-examiner agreement were assessed using the weighted kappa test. Results: Neither MAR nor the application of sharpening filters significantly impacted AUC or specificity (P>0.05). However, sensitivity increased when MAR was combined with Sharpen 1× and Sharpen 2× (P=0.015). The intra-examiner agreement ranged from fair to substantial (0.34-0.66), while the inter-examiner agreement ranged from fair to moderate (0.27-0.41). Conclusion: MAR in conjunction with sharpening filters improved VRF detection; therefore, their combined use is recommended in cases of suspected VRF.

Effect of object position in the field of view and application of a metal artifact reduction algorithm on the detection of vertical root fractures on cone-beam computed tomography scans: An in vitro study

  • Nikbin, Ava;Kajan, Zahra Dalili;Taramsari, Mehran;Khosravifard, Negar
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.245-254
    • /
    • 2018
  • Purpose: To assess the effects of object position in the field of view (FOV) and application of a metal artifact reduction (MAR) algorithm on the diagnostic accuracy of cone-beam computed tomography (CBCT) for the detection of vertical root fractures(VRFs). Materials and Methods: Sixty human single-canal premolars received root canal treatment. VRFs were induced in 30 endodontically treated teeth. The teeth were then divided into 4 groups, with 2 groups receiving metal posts and the remaining 2 only having an empty post space. The roots from different groups were mounted in a phantom made of cow rib bone, and CBCT scans were obtained for the 4 different groups. Three observers evaluated the images independently. Results: The highest frequency of correct diagnoses of VRFs was obtained with the object positioned centrally in the FOV, using the MAR algorithm. Peripheral positioning of the object without the MAR algorithm yielded the highest sensitivity for the first observer (66.7%). For the second and third observers, a central position improved sensitivity, with or without the MAR algorithm. In the presence of metal posts, central positioning of the object in the FOV significantly increased the diagnostic sensitivity and accuracy compared to peripheral positioning. Conclusion: Diagnostic accuracy was higher with central positioning than with peripheral positioning, irrespective of whether the MAR algorithm was applied. However, the effect of the MAR algorithm was more significant with central positioning than with peripheral positioning of the object in the FOV. The clinical experience and expertise of the observers may serve as a confounder in this respect.

Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study

  • Larissa Pereira Lagos de Melo;Polyane Mazucatto Queiroz;Larissa Moreira-Souza;Mariana Rocha Nadaes;Gustavo Machado Santaella;Matheus Lima Oliveira;Deborah Queiroz Freitas
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.16.1-16.11
    • /
    • 2023
  • Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.

Evaluation of Metal Artifact Reduction for Orthopedic Implants (O-MAR) on Radiotherapy Treatment Planning (방사선 치료 계획 시 O-MAR (Metal Artifact Reduction for Orthopedic Implants) 적용의 유용성 평가)

  • Won, Huisu;Hong, Joowan;Kim, Sunyoung;Choi, Jaehyock;Cho, Jaehwan;Yang, Hanjoon;Lee, Jin;Lee, Sunyeob;Park, Cheolsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.217-223
    • /
    • 2014
  • The aim of this study is evaluation of dose distribution on radiation therapy planning system with the CT image of high-density material inserted phantom. Gammex 467 Tissue Characterization Phantom is used to acquire an image similar to the human tissues and insert a Titanium to generate metal artifact. The acquired images were reconstructed with Metal Artifact Reduction for Orthopedic Implants (O-MAR). By using the treatment planning system, the volume was analyzed and dose distribution was extracted. Photon dose distribution in linear accelerator was measured by the $MapCHECK^{TM}$ and compared with planned and measured dose distributions. In result of the comparative analysis, when artifact is generated by Titanium, The volume applied O-MAR was increased 6.8% to BR-12 Breast and 40.2% to LV 1 Liver. After O-MAR was used, Dose distribution was higher 1.4 to 1.6% than before. Consequently, The artifact caused by metal objects should be removed if possible, and after that used in the radiotherapy treatment plan can be considered to reduce errors.

Image Evaluation by Metallic Hip Prosthesis in Computed Tomography Examination (컴퓨터단층촬영검사에서 고관절 삽입물에 의한 영상평가)

  • Min, Byung-In;Im, In-Chul
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.281-288
    • /
    • 2022
  • In this study, four algorithms (Soft, Standard, Detail, Bone) were used for general CT scan (Before MAR) images and MAR (After MAR) images for patients with metal implants inserted into the hip joint. was applied to compare and analyze Noise, SNR, and CNR to find out the optimal algorithm for quantitative evaluation. As the analysis method, Image J program, which can calculate image analysis and area and pixel values on the image reconstructed with four algorithms, was used. In order to obtain Noise, SNR, and CNR, the HU mean value and HU SD value were obtained by designating the bone (ischium) closest to the metal implant in the image for the measurement site, and the background noise was the surrounding muscle. The region of interest (ROI) was equally designated as 15 × 15 mm in consideration of the size of the bone, and the values of SNR and CNR were calculated according to the given equation. As a result, for noise, After MAR and Soft algorithms showed the lowest noise, and SNR and CNR showed the highest for Before MAR and Soft algorithms. Therefore, the soft algorithm is judged to be the most appropriate algorithm for metal implant hip joint CT.

Undecided inference using logistic regression for credit evaluation (신용평가에서 로지스틱 회귀를 이용한 미결정자 추론)

  • Hong, Chong-Sun;Jung, Min-Sub
    • Journal of the Korean Data and Information Science Society
    • /
    • v.22 no.2
    • /
    • pp.149-157
    • /
    • 2011
  • Undecided inference could be regarded as a missing data problem such as MARand MNAR. Under the assumption of MAR, undecided inference make use of logistic regression model. The probability of default for the undecided group is obtained with regression coefficient vectors for the decided group and compare with the probability of default for the decided group. And under the assumption of MNAR, undecide dinference make use of logistic regression model with additional feature random vector. Simulation results based on two kinds of real data are obtained and compared. It is found that the misclassification rates are not much different from the rate of rawdata under the assumption of MAR. However the misclassification rates under the assumption of MNAR are less than those under the assumption of MAR, and as the ratio of the undecided group is increasing, the misclassification rates is decreasing.

Drought Analysis of Nakdong River Basin Based on Multivariate Stochastic Models (다변량 추계학적 모형을 이용한 낙동강 유역의 가뭄해석에 관한 연구)

  • Heo, Jun-Haeng;Kim, Gyeong-Deok;Jo, Won-Cheol
    • Journal of Korea Water Resources Association
    • /
    • v.30 no.2
    • /
    • pp.155-163
    • /
    • 1997
  • In this study, drought analysis of annual flows of Jindong, Hyunpoong, and Waekwan stations located at Nakdong River Basins was performed based on multivariate stochastic models. The stochastic models used were multivariate autoregressive model (MAR) and multivariate contemporaneous (MCAR) model. MCAR(1) and MAR(1) models were selected to be a appropriate models for these stations based on skewness test of normality, test of uncorrelated residuals, and correlograms of the residual series of each model. The statistics generated by MCAR(1) model and MAR(1) model resembled very closely those computed from historical series. The drought characteristics such as run len호, run sum, and run intensity were fairly well reproduced for the various lengths of generated annual flows based on the MCAR(1) and MAR(1) models. Thus, these drought characteristics may give the important informations in planning mid or long term water supplying systems.

  • PDF

The Influence of Carcass Traits on Carcass Price in Mature Hanwoo Cow (한우 암소에서 도체형질과 도체가격간의 상관관계)

  • Kim, Dae-Jung;Lee, Chang-Woo;Lee, Chae-Young;Kim, Jong-Bok
    • Journal of Animal Science and Technology
    • /
    • v.52 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • We investigated the influence of carcass traits on carcass price for Hanwoo cow using multiple regression and path analyses. Data for carcass traits and price were collected on mature Hanwoo cow raised in private farms in Kangwon province that were slaughtered in 2008. A total of 96 animals with the average slaughter age of 51 months were used in the current study. Of the carcass traits studied, marbling score (MAR), dressing percentage (DP), and eye-muscle area (EMA) showed moderate and positive correlations with auction price (AP), while correlation coefficients of meat yield index (MINDEX) with AP were low or even negligible. In multiple regression analyses of AP and carcass price (CP) on cold carcass weight (CWT), back fat thickness (BFT), EMA, MAR, and DP, estimates of $R^2$ were 69.86 and 85.43%, respectively. Partial regression coefficients for CWT, BFT, EMA, MAR and DP were -0.028, -0.106, 0.107, 0.814, and 0.075 in the equation of AP and 0.561, -0.060, 0.083, 0.590, and 0.051 in the equation of CP. In path analyses, MAR's total contribution on the variation of AP was largest (0.667), and the total contributions of MAR and CWT on the variation of CP were 0.403 and 0.397. The current study suggested that marbling was the most influential trait on the variation of auction price, and marbling and cold carcass weight were critical traits on the variation of carcass price.

MarSel : LD based tagSNP Selection System for Large-scale SNP Haplotype Dataset (MarSel : 대용량 SNP 일배체형 데이터에 대한 연관불균형기반의 tagSNP 선택 시스템)

  • Kim Sang-Jun;Yeo Sang-Soo;Kim Sung-Kwon
    • The KIPS Transactions:PartA
    • /
    • v.13A no.1 s.98
    • /
    • pp.79-86
    • /
    • 2006
  • Recently the tagSNP selection problem has been researched for reducing the cost of association studies between human's diversities and SNPs. General approach for this problem is that all of SNPs are separated into appropriate blocks and then tagSNPs are chosen in each block. Marsel in this paper is the system that involved the concept of linkage disequilibrium for overcoming the problem that the existing block partitioning approaches have short of biological meanings. In most approaches, the contiguous regions, which recombinations have LD coefficient |D'| and then tagSNP selection step is performed. And MarSel guarantees the minimum tagSNP selection using entropy-based optimal selection algorithm when tagSNPs are chosen in each block, and enables chromosome-level association studies using efficient memory management technique when input is very large-scale dataset that is impossible to be processed in the existing systems.