• Title/Summary/Keyword: manufactured device

Search Result 627, Processing Time 0.039 seconds

Electronic Properties of MIM Structure for application in Communication Device (통신소자 응용을 위한 MIM 구조 유기박막의 전자특성)

  • Choi, Young-Il;Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1279-1282
    • /
    • 2005
  • Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. MDC flowing across monolayers is analyzed using a rod-like molecular model. LB layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Au/Arachidic acid/Al, the number of accumulated layers are $3{\sim}9$. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from -3 to +3[V].

  • PDF

Deposition Transfer and Electrical Properties of Arachidic Acid Multilayer Manufacture by LB Method (LB법으로 제작한 Arachidic Acid 다층막의 누적전이와 전기특성)

  • Song, Jin-Won;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.11-14
    • /
    • 2001
  • We give pressure stimulation into organic thin films and then manufacture a device under the accumulation condition that the state surface pressure is 30[mN/m]. LB layers of Arac. acid deposited by LB method were deposited onto slide glass as Y-type film. The physicochemical properties of the LB films were examined by UV absorption spectrum, SEM and AFM. The structure of manufactured device is Au/arachidic acid/Al. the number of accumulated layers are 3~9. Also. we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from -3 to +3[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

A Study on Electrical Characteristics of Organic Thin Film (유기박막의 전기적 특성 연구)

  • Choi Yong-Sung;Song Jin-Won;Moon Jong-Dae;Lee Kyung-Sup
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.10
    • /
    • pp.953-959
    • /
    • 2006
  • Langmuir-Blodgett(LB)layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Au/arachidic acid/Al, the number of accumulated layers are $9{\sim}21$. Also, we then examined of the Metal-Insulator-Metal(MIM) device by means of I-V. The I-V characteristics of the device are measured from -3 to +3 V. The insulation property of a thin film is better as the distance between electrodes is larger.

A Study on the Electrical Properties of PBLG and PBDG monolayers (PBLG와 PBDG단분자막의 전기특성에 관한 연구)

  • Kim, Beyung-Geun;Cho, Su-Young;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.92-94
    • /
    • 2003
  • Recently, the study on development of electrical and electronic device is done to get miniature, high degrees of integration and efficiency by using inorganic materials, the study of Langmuir-Boldgett(LB) method that uses organic materials because of the limitation for the ultra small size. In this paper, detected displacement current using PBLG and PBDG, deposition and observed the electrical characteristics to each 1, 3, 5, 7, 9 layers by LB method. Maximum value of change ratio of displacement current by the detected speed and temperature appeared almost lineally, could confirm that it are in comparison relation each other speed-temperature and displacement current. The structure of manufactured device is MIM. Also, we then examined of the MIM device by means of I-V. The I-V characteristic of the device is measured from 0 to +2[V]. The insulation property of a thin film is better as the distance between electrodes is larger.

  • PDF

Analysis of Hematoporphyrin Derivative by Design and Manufacture of High Resolution Charge Coupled Device in Spectrometry (분광기에 고 분해능 Charge Coupled Device의 설계 및 제작에 의한 Hematoporphyrin Derivative의 분석)

  • Kim, Ki-Jun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.22 no.1
    • /
    • pp.77-83
    • /
    • 2005
  • The influence of fluorescence, scattering, and absorbance in turbid material by light scattering was interpreted by the scattered fluorescence intensity and wavelength. The effect of optical property in scattering media was investigated. It is very important to study the charge coupled device(CCD) in spectrometry because we can use the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy. CCD is very essential to study the molecular structure and medical engineering combined laser spectroscopy in the modem physical and chemistry. Accordingly, this study has designed and manufactured the electromagnetic spectrometry with CCD, and has analyzed the hematoporphyrin derivative.

Development of A Wearable Input Device Recognizing Human Hand and Finger Motions as A New Mobile Input Device

  • Dae H. Won;Lee, Ho G.;Kim, Jin-Y;Park, Jong H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.153.3-153
    • /
    • 2001
  • Recently, the researches on the mobile computing technologies for palm computers, PDA´s and wearable computers became very active. In the development of mobile devices, one of the key technologies is the human interface. So, this paper suggests a new input device for PDA´s and wearable computers so-called key-glove. The design methods of key-glove are discussed in this paper and we manufactured the key-glove which recognizes that character is typed in though the hand´s movements analysis and is designed as an input device for wearable computers and virtual environment. Also, we are executes a performance test for alphanumeric data entry, command entry and X-Y pointer input. In the results, we are confirmed in its ...

  • PDF

Development of an Improved RF Dosimeter (개량된 비접촉형 RF 선량계 구현)

  • Son, Jong-Dea;Lee, Seung-Min;Lee, Heung-Ho;Lee, Nam-Ho;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.540-543
    • /
    • 2003
  • This paper presents design and manufacture of RF type non-contact radiological dosage measuring device. It also concerns on the broad out-line and the ways of improvement about RF type non-contact radiation measuring device. Measuring radiological dosage with non-contact RF, the stability and efficiency of the measure have been improved by reforming constant current circuit. Furthermore, applying communication protocol in process makes it possible to achieve faster and more accurate communication than old circuit. On the base of those, RF type non-contact radiological dosage measuring device which consists of radiological dosage measuring module and Reader module has been designed and manufactured. While testing communication against embodied device, the possibility of the field application could be confirmed.

  • PDF

Force Feedback Control of 3 DOF Haptic Device Utilizing Electrorheological Fluid (ER 유체를 이용한 3 자유도 햅틱 장치의 힘 반향 제어)

  • Han, Y.M.;Kang, P.S.;Choi, S.B.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.213-216
    • /
    • 2005
  • This paper presents force feedback control performance of a 3DOF haptic device that can be used for minimally invasive surgery (MIS). As a first step, a 3DOF electrorheological (ER) joint is designed using a spherical mechanism. And it is optimized based on the mathematical torque modeling. Subsequently, the master haptic device is manufactured by the spherical joint. In order to achieve desired force trajectories, model based compensation strategy is adopted for the ER master. Therefore, Preisach model fur the PMA-based ER fluid is identified using experimental first order descending (FOD) curves. A compensation strategy is then formulated through the model inversion to achieve desired force at the ER master. Tracking control performances for sinusoidal force trajectory are presented, and their tracking errors are evaluated.

  • PDF

Characterization of photonic quantum ring devices manufactured using wet etching process (습식 식각 공정을 이용하여 제작된 광양자테 소자의 특성 분석)

  • Kim, Kyoung-Bo;Lee, Jongpil;Kim, Moojin
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.6
    • /
    • pp.28-34
    • /
    • 2020
  • A structure in which GaAs and AlGaAs epilayers are formed with a metal organic chemical vapor deposition equipment on a GaAs wafer similar to the structure of making a vertical cavity surface emitting laser is used. Photonic Quantum Ring (PQR) devices that are naturally generated by 3D resonance are manufactured by chemically assisted ion beam etching technology, which is a dry etching method. A new technology that can be fabricated has been studied, and as a result, the possibility of wet etching of a solution containing phosphoric acid, hydrogen peroxide and methanol was investigated, and the device fabrication by applying this method are also discussed. In addition, the spectrum of the fabricated optical device was measured, and the results were theoretically analyzed and compared with the wavelength value obtained by the measurement. It is expected that the PQR device will be able to model cells in a three-dimensional shape or be applied to the display field.

A Study on the X-ray Image Reading of Radiological Dispersal Device (방사능 폭발물의 X-ray 영상판독에 관한 연구)

  • Geun-Woo Jeong;Kyong-Jin Park
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.2_2
    • /
    • pp.437-443
    • /
    • 2024
  • The purpose of radiological Dispersal Device(RDD) is to kill people by explosives and to cause radiation exposure by dispersing radioactive materials. And It is a form of explosive that combines radioactive materials such as Co-60 and Ir-192 with improvised explosives. In this study, we tested and evaluated whether it was possible to read the internal structure of an explosive using X-rays in a radioactive explosive situation. The improvised explosive device was manufactured using 2 lb of model TNT explosives, one practice detonator, one 9V battery, and a timer switch in a leather briefcase measuring 41×35×10 cm3. The radioactive material used was the Co-60 source used in the low-level gamma ray irradiation device operated at the Advanced Radiation Research Institute of the Korea Atomic Energy Research Institute. The radiation dose used was gamma ray energy of 1.17 MeV and 1.33 MeV from a Co-60 source of 2208 Ci. The dose rates are divided into 0.5, 1, 2, and 4 Gy/h, and the exposure time was divided into 1, 3, 5, and 10 minutes. Co-60 source was mixed with the manufactured explosive and X-ray image reading was performed. As a result of the experiment, the X-ray image appeared black in all conditions divided by dose rate and time, and it was impossible to confirm the internal structure of the explosive. This is because γ-rays emitted from radioactive explosives have higher energy and stronger penetrating power than X-rays, so it is believed that imaging using X-rays is limited By blackening the film. The results of this study are expected to be used as basic data for research and development of X-ray imaging that can read the internal structure of explosives in radioactive explosive situations.