• Title/Summary/Keyword: manhole

Search Result 121, Processing Time 0.031 seconds

A Study on Design of Vacuum Silo for Batch Treatment System for Dredged Soil (준설토 일괄처리시스템을 위한 진공사이로 설계에 관한 연구)

  • Kim, Yong-Seok;Yang, Hae-Rim;Kim, Hac-Sun;Jeoung, Chan-Se;Yang, Soon-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.5
    • /
    • pp.571-577
    • /
    • 2012
  • In this study, a small movable batch treatment system for dredging soil deposited in a rain water tube is proposed; further, a vacuum silo sorting separation device with a vacuum silo, first-stage sorting separator, and conveyor is designed. The vacuum silo sorting separation device also consists of a storage tank, transferring screw, vacuum gate, screen bar, screen bar cleaner, and vacuum discharging device. In view of the fact that the flow of drawn air in the storage tank is a major factor influencing the sorting separation performance, the optimum shape of the tank is determined by CFD flow analysis. In addition, by using CAE structure analysis, the safety of a storage tank made of boards is examined. The specifications of the vacuum silo sorting separation device are determined by conducting mechanical and dynamic simulations of the driving mechanism of the vacuum silo sorting separation device through 3D-CAD modeling. Following this study, we will design a drum-screen-type second sorter, a decanter-type dehydration device, and waste water tank and pump as a secondary device. Further, on the basis of this design, we will construct a prototype model and carry out a field test.

Dynamic Analysis of Buried Pipelines with Manhole during a Soil Liquefaction Process (흙의 액화과정에 따른 맨홀이 있는 지하 매설관의 동적해석)

  • Shim, Jae Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 1991
  • Recently, researches for buried lifelines such as pipelines have been carried out to provide for safe design. On of the major causes to the damage of buried pipelines has been soil liquefaction. Analytical models have been presented to compare with the results from recent model experiment under a soil liquefaction environment induced by seismic shaking table. The analytical results were more than two times those those of experimental measurement. Thus the objective of this study is to introduce a rigorous nonlinear analysis of equation of motion with more realistic parameters which are dynamic soil and water pressure, dynamic subgrade reaction coefficient, and damping coefficient for soil liquefaction environment.

  • PDF

Design Development of Street Furniture for Improvement of Urban Environment - Focusing on "Y" District, a part of the Seoul Design Street Project -

  • Kim, Kook-Sun
    • Journal of the Korea Furniture Society
    • /
    • v.20 no.6
    • /
    • pp.581-589
    • /
    • 2009
  • Under 'The Design Street' Project, one of the urban environment improvement projects of Seoul, the facilities on the street have been greatly varied in terms of design. In addition, the municipal authority has pushed each district to develop its own identity based on the integrated design of the city. This study was aimed to propose a design which could solve the current problem in street furniture in terms of environmental improvement through an analysis on current street conditions in "Y" District as a part of Seoul Design Street Project. It has attempted to propose 11 street furnitures based on the basic strategy of 'Soft City' which has been promoted by Seoul City in accordance with the Seoul Public Facility Guidelines as 1. Airy Design, 2. Integrated Design, 3. Collaborative Design and 4. Sustainable Design. Among them, for the total design in Seoul six facilities - kiosk, manhole, traffic signal controller, public phone, road sign and waste receptacle were proposed by Seoul City have been accepted. For local differentiation, on the contrary, five items - planter bench, bollard, lifter, bike rack and fence have been newly designed and proposed. Furthermore, it is essential to carry out systematic supervision and continuous management on the detail design and construction of current regional design development projects.

  • PDF

A Study on the Development of Grating Structure for Drain of Water (도로 배수용 그레이팅 구조의 개선에 관한 연구)

  • Kim Key-Sun;Lee Eun-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.531-538
    • /
    • 2006
  • Grating is an installed structure on the road for drain. This paper proposes a new product which can prevent the accumulation of earth and sand through the improvement of Grating structure. There were usually harmful insects and bad smell because of accumulated garbage in the frame of previous product. The product had a reverse-flowing sewage due to the bad draining in case of rain. The whole thing of the existing Grating installed with the one set of frame and main body should be changed when it was damaged. This study is to develop a structure which can separate grating main body from frame and grating main body can equip and separate after fixing frame to the manhole with cement. also install jig for the loss prevention and change for the better.

  • PDF

A Study on the Heat Transfer Analysis based on Insulation Thickness Variation of Cable Splice Part (지중케이블 접속부의 절연층 두께변화에 따른 열해석 연구)

  • 최규식
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.246-255
    • /
    • 1998
  • The cable cooling through installing the cooling pipe along the transmission cable becomes universal in foreign leading countries, especially in Japan, and, there are so many study results inside and outside of the country. However, the remarkable study result for cooling method of cable splice part is not achieved in spite of its importance. This paper is, therefore, carrys out detailed heat transfer analysis of existing 154kV underground cable-splice, depending on the insulation thickness variation when it is installed in manhole of tunnel whose temperature is maintained as $10^{\circ}C$ using refrigerator. This paper study also the cooling method of underground cable splice based on this result.

  • PDF

The Assessment of Wastewater Treatment and Management Using Performance Indicators and Cluster Analysis (수행능 지표(Performance Indicator)와 군집분석을 이용한 하수도시설 및 운영 평가)

  • Kim, Shin-Geol;Choi, Tae-Yong;Koo, Ja-Yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.2
    • /
    • pp.165-175
    • /
    • 2007
  • Performance indicators haven't been used for the assessment of the wastewater treatment facility or management in Korea yet, therefore they are going to be important parts in wastewater utilities because they are used to understand present situation and to compare one with other wastewater utilities. In this study, we used performance indicators to assess the condition of wastewater utilities and they were divided into four categories (A, B, C, and D). A category represented the condition of the planning & construction and composed of wastewater supply, disaster defence and employees. B category represented maintenance of wastewater utilities and were composed of manhole, sewer, and technical employees. C category showed the operation efficiency of wastewater utilities and D category represented the environmental load. To analyze the situation of wastewater utilities overall, cluster analysis was performed using four categori' es indicators. And CCC (Cubic Clustering Criterion) and R-square were used to decide the proper number of clusters, and wastewater utilities of 48 cities were divided into 5 groups(I, II, III, IV, and V groups). Each cluster was analyzed by average and standard deviation to understand the situation of wastewater utilities. A group analysis showed that IV and V clusters were insufficient, B group showed that I and IV groups were insufficient, C group showed all clusters are above average, and D group was also like C group.

Analysis of Hydraulic Similarity at Surcharged Square Manhole (과부하 사각형 맨홀에서의 수리학적 상사성 분석)

  • Kim, Jung-Soo;Yoon, Young-Noah;Han, Chyung-Such;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.510-514
    • /
    • 2008
  • 우수 관거 시스템에서 맨홀의 설치 시 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 수두손실의 발생이 필연적일 수밖에 없다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 고려하여 설계를 수행하고 있으며, 맨홀에서의 수두 손실은 거의 대부분 고려되지 않고 있다. 단지 맨홀에서의 수두손실을 저감하기 위하여 하수도시설기준(환경부, 2005)상의 단차 및 인버트 규정만 있을 뿐, 우수 관거 설계에 직접적으로 필요한 적절한 맨홀의 손실계수가 제시되지 않고 있는 실정이다. 국외에서는 축소 수리 모형을 이용한 실험과 수치해석 기법 등을 이용하여 맨홀에서의 손실계수를 산정하는 연구가 꾸준히 진행되어 왔으나 국내에서는 맨홀의 손실계수 산정에 관한 연구가 미흡한 실정이며, 더욱이 맨홀에서의 손실계수 산정을 위한 상사성 적용에 관한 연구는 전무한 실정이다. 그러므로 본 연구에서는 맨홀의 축척 변화에 따른 손실계수의 변화를 분석하기 위하여 하수도시설기준(환경부, 2005)의 특 1호(사각형) 맨홀을 각각 1/2과 1/5로 축소 제작하고, 수리실험 장치를 제작하였다. Froude 상사 법칙을 적용하여 1/2의 축소 모형의 실험 조건을 1/5 축소 모형의 값으로 환산하였으며, 각 축소 모형에 대한 수리 실험을 실시하였다. 과부하된 맨홀의 손실계수를 예측하는데 Froude 상사법칙의 사용 가능성을 확인 하였으며, 1/2 축소 모형과 1/5 축소 모형에서 산정된 손실계수 값이 0.45로 일치하고 있으므로 우수 관거 시스템의 맨홀 설계 시, 축소 수리 모형실험에서 산정된 손실계수의 직접적인 적용이 가능하다고 판단된다.

  • PDF

Calculation of Head Loss Coefficient at Surcharged Circular Manhole Using Fluent Model (Fluent 모형을 이용한 과부하 원형 맨홀에서의 손실계수 계산)

  • Kim, Jung-Soo;Kim, Jong-Woo;Kim, Hyung-Min;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1828-1832
    • /
    • 2008
  • 우수 관거 시스템에서 흐름은 중력에 의해서 흐르고 개수로 흐름과 같이 처리된다. 그러나 유입유량이 관거의 만관 상태를 초과하거나 하류 흐름의 제한 때문에 발생하는 역류의 영향을 받는다면, 우수 관거 시스템은 과부하(surcharge) 상태의 압력흐름이 된다. 개수로 상태에서 맨홀에서의 수두 손실은 일반적으로 무시되지만, 과부하 맨홀에서의 수두손실은 중요하며, 우수 관거 시스템의 전체 손실에 중요한 부분을 차지하게 된다. 이러한 현상은 여러 개의 맨홀을 가지는 우수 관거 시스템에서 특히 중요한 사항이 된다. 현재 계획 또는 설계단계에서 수행되고 있는 관거 시설의 수리계산에서는 연결관의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 수두손실은 고려되지 않는 실정이다. 본 연구에서는 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 모형을 이용하여 과부하 원형 맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 계산된 손실계수는 수리모형 실험을 통하여 산정된 손실계수와 비교하였다. 수치 모형에 의해서 산정된 손실계수 값이 수리모형 실험에 의해서 산정된 손실계수 값보다 약간 크게 산정되었다. 앞으로 난류 모형의 매개 변수들의 조정을 통한 정확한 수치모의 연구가 필요하다고 판단된다.

  • PDF

Research and Development of Electrode Surface Inspection System (전극 표면 검사 장치 연구 개발)

  • Oh, Choonsuk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.123-128
    • /
    • 2016
  • In manufacturing processing of a secondary battery, the visual inspection system is studied and developed to check the surface defects of the electrode plates. It consists of two parts, one is the hardware control and the other software implementation. The former is made up to the system configuration and the design of the optical system, the illuminations and the controllers. The latter is the detection algorithms of the surface defects. This system achieves the quality improvement of the electrode process and the price competitiveness. By using the proposed defects detection algorithms this system demonstrates the high reliability of spot, line, manhole, extraneous substance, scratch, and crater defect of a electrode plate surface.

A study on the Effect of SOB(Sulfur-Oxidizing Bacteria) Media on the Removal of Hydrogen Sulfide in Water of Septic Tank (SOB(Sulfur Oxidizing Bacteria) Media가 정화조의 수중황화수소 제거에 미치는 영향에 관한 연구)

  • Song, Homyeon;Cho, Jeongil;Kim, Taeksoo;Kwon, Sucheol;Yu, Hyeongsik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.59-67
    • /
    • 2013
  • The odor occurring in the sewage system induces the displeasure, the disgust such as the headache, the vomit, etc. and increases the spiritual stress and disturbs the pleasant life of residents. These odors occur mainly in the area of combined sewage system treatment, being created in the personal sewage treatment plant such as septic tank and are incoming to sewage pipes and emitted to the outside through the manhole and the receiver, etc.; and this causes odors to the people. The Hydrogen Sulfide, the Methyl Mercaptan, the Ammonia, etc. are materials causing the odor, the more serious issue of odor is occurring since the septic tank of degradation process is being applied. The primary cause of odor is the decomposition of human feces in the septic tanks and sewage disposal facilities. The purpose of this study is reduction of hydrogen sulfide using air supplying and SOB(Sulfur-Oxidizing Bacteria). As a result of this study of the air supply system and the SOB media equipment by air supply, in case the air is injected to SOB media compared to the injection of air only, the removal efficiency the hydrogen sulfide was average 3.4 times higher.