• 제목/요약/키워드: man-machine interface(MMI)

검색결과 65건 처리시간 0.027초

TENSION LEVELLER 상태감시 및 진단시스템 개발 (Development of Tension Leveller Condition Monitoring and Diagnosis System)

  • 신남호;김수광;최석욱
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.350-354
    • /
    • 1995
  • The Tension Leveller of Cold Rolling Mill In POSCO performs levelling the strip in high speed line. But minor variations in operating condition of driving machines such as motor, gear box, and support bearings, a small gap-variation of supporter and strip slip by poor roll revolutions can cause serious problems in the quality of strip. In this study, firstly, A condition monitoring standard for each sensor is made through with the detail analysis of vibration and strip slip. Secondly, An automatic monitoring and diagnosing system was developed to monitor the condition of Tension Leveller, and diagnose the cause of abnormal condition. Finally, A diagnosing algorithm for abnormal condition and man-machine interface (MMI) for easy operation are developed.

  • PDF

원자력 발전소 환경 디자인 설계를 위한 인체측정에 대한 연구 (Anthropometric Data Collection for MCR Environment Design of Nuclear Power Plant)

  • 차우창
    • 시스템엔지니어링학술지
    • /
    • 제6권1호
    • /
    • pp.47-52
    • /
    • 2010
  • Human Factors Engineering (HFE) for Main Control Room (MCR) of Nuclear Power Plant (NPP) has been applied to optimize the design and operation of Man-Machine Interface (MMI) between operators and their equipment in consideration of physical, psychological and cognitive aspects. However, it has been observed that operators complain about environmental discomfort in the MCR since the operators in the MCR experience excessive stress due to the environmental factors such as inappropriate interior and lighting system. Since the HFE is an essential factor for the high fidelity performance of operators in the MCR, the adequate MCR environment design with HFE rules and guidelines is as much important to enhance the operability and reliability of the MCRs. Therefore, there has been a strong need to design a pleasant environment for the MCR to improve human performance of the operators.

  • PDF

발전소용 분산제어 시스템의 개발

  • 문봉채
    • 전기의세계
    • /
    • 제41권9호
    • /
    • pp.23-37
    • /
    • 1992
  • 본 고에서는 분산제어 시스템의 일반적인 요건 및 기능, 시스템 구조에 대하여 정리해 보고, 발전소용 분산제어 시스템으로써 국내 최초의 개발품이 될 KEDIC 시스템의 구성과 기능들을 살펴본 후 선진제품과 대등한 수준 더 나아가 앞서 수준으로 가기위해 노력해야 할 향후 과제들을 설정해 보았다. 기술 대형화 및 종합화 측면에서 분산제어 시스템의 기구 기술, 아날로그 및 디지탈 하드웨어 기술, 현장의 엔지니어링 기술, 프로세스 제어기술, Field Bus 및 LAN(Local Area Network)등의 통신기술, GUI로 대표되는 MMI(Man-Machine Interface) 기술, 기타 소프트웨어적으로 현장 데이타 및 운전 지원 데이타 관리에 필요한 데이타베이스 관리 기술과 실시간 처리기술 등이 통합되어 있다. 따라서 요소기술의 확보 혹은 기술 수준의 향상에 꾸준한 관심을 기울여야 함은 물론이거니와 무엇보다도 요소기술 변화에 대응할 수 있는 시스템 통합기술력 배양에 노력을 기울여야 할것이다.

  • PDF

765KV 변전설비 운전중 상태감시 및 진단을 위한 전문가시스템 개발 (Development of Expert System to Diagnose and Monitor 765KV Power Apparatus in On-line Condition)

  • 최인혁;권동진;정길조;유연표;김광화;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.699-701
    • /
    • 2001
  • The expert system monitoring and diagnosing 765kV power apparatus was described in this paper. To develop this expert system, we studied the knowledge bases and data bases for 765kV transformer and GIS. In order to make the reliable inference of knowledge base and the good MMI(Man Machine Interface), the data bases were consisted of the tables of power apparatus information, limit level value, measured input data, inference result and diagnosis result. The knowledge base had various rules to infer the conditions of transformer and GIS. We applied both the forward chaining and backward chaining methods to these rules of system for good inferences. This paper describes the applied methods for expert system. Also, this developed system was tested with dissolved gas analyzing result and the result was shown.

  • PDF

이기종 물관리자동화시스템의 통합 방안 (Integration Method in Different Kind of TM/TC System)

  • 고광돈;권순국;임창영;곽영철;김동주
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.231-234
    • /
    • 2003
  • The Closed Control System, which uses exclusive network and protocol, have been adopted in TM/TC systems. However, the Closed Control System is known that it is not able to support the integration in the water management automation. There are two methods in integration solution in different types of TM/TC System. One solution is hardware system integration that is very expensive and impractical. The other solution is software system integration that uses OLE for Process Control(OPC). In this study, we recommend OPC solution, for KARICO water management, that is the practical and efficient. KARICO is using OPC technology in MMI(Man machine Interface) and water management program. Through this technology, the real-time status of reservoir, pumping station and canal can be achieved without difficulty.

  • PDF

배전급 전력케이블 장기열화설비 자동화시스템 구축에 관한 연구 (A Study on Constructing the Automatic Control System of the Power Cable lest Facility)

  • 강문호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.512-514
    • /
    • 2004
  • 배전급 전력케이블의 장기수명특성 평가를 위한 기초자료를 확보하기 위해 고창 배전 실증시험장내에 장기열화시험을 수행할 수 있는 실증시험설비가 구축되었다. 이 설비를 안전하고 효과적으로 관리 운영하기 위해 원격감시제어기능, 자동운전기능 및 열화데이터의 효과적이 처리기능이 포함된 장기열화설비 자동화시스템의 구축이 필요하였다. 따라서 본 논문에서는 새롭게 개정된 한전 표준구매규격과 참고규격인 개정판 AEIC CS5 규격에 맞게 구축된 배전급 전력케이블 장기 열화시험설비를 원격감시제어, 자동운전 및 열화 데이터의 저장 및 처리가 가능한 전력케이블 장기열화설비 자동화시스템의 하드웨어 구성 및 MMI (Man-Machine Interface)화면의 구성방안에 대하여 기술하였다. 본 자동화시스템을 이용해 기존의 간이 차수형 CNCV케이블의 AEIC규격 수트리시험을 안전하게 수행하였다.

  • PDF

MMIS 모사설비의 응용 소프트웨어 개발 프로세스 (Development Process of Application Software for MMIS Simulation Facility)

  • 박근옥;이종복;이준구
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2002년도 추계학술대회 논문집
    • /
    • pp.47-51
    • /
    • 2002
  • 전 규모에서 소규모에 이르는 MMIS(Man Machine Interface System) 모사설비는 실제의 원자력발전소에 사용될 MMIS를 응용 소프트웨어로 구동되는 모사환경을 통하여 사전에 시험 및 검증할 목적으로 사용된다. 기존의 MMIS 모사설비 개발은 잘 정의된 개발 프로세스에 기반을 두지 않고 프로젝트 관리자 또는 개발 담당자의 경험과 직관에 의존하여 수행되었다. 이로 인하여 MMIS 모사설비의 개발 일정이 지연되거나 개발의 결과가 초기목표를 만족하지 못하는 불만족 사항이 나타났다. 본 연구는 MMIS 모사설비의 응용 소프트웨어 개발을 위한 프로세스를 정의하고 이에 따라 설비개발을 진행하였다. 개발 프로세서는 계획 단계, 설계 및 구현단계, 시험단계의 세 부분으로 구성하였다. 본 논문에서는 MMIS 모사설비에 요구되는 일반적인 성능특성요건과 개발공정요건을 살펴보고, 본 연구가 정립한 응용 소프트웨어 개발의 프로세스 및 각 프로세서에서의 공정활동을 제시한다.

  • PDF

TCP/IP Protocol을 이용한 원격 감시용 계측 시스템 개발에 관한 연구 (A Study of Development of a Remote Monitoring Data Acquisition System using TCP/IP Protocol)

  • 문경록;이주열;김재문
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(5)
    • /
    • pp.173-176
    • /
    • 2002
  • DAS(Data Acquisition System) as a ground support equipment has played a critical role in proving the status of ready-to-fire of a rocket system before launch. But it is hard to implement and place a real-time measuring system in a control room at a long distance from the vehicle. In this paper DAS is introduced by being located at the LEC(Launch Equipment Container)[1], 50 meters away from the rocket and connected to remote monitoring system via fiber optics with TCP/IP protocol by means of client/server algorithm. Therefore real-time data acquisition and storage are guaranteed and a convenient and useful MMI (Man-Machine Interface) can be developed.

  • PDF

중소형 일체형 원자로의 MMIS 설계를 위한 인간공학 현안추적시스템

  • 박근옥;구인수;이철권;박희윤
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.323-328
    • /
    • 1997
  • 중소형 일체형 원자로의 MMIS(Man-Machine Interface System) 설계개발 과정에 활용할 목적으로 관계형 데이터베이스 기반의 인간공학 현안추적시스템을 개발하였다. 동 시스템은 MMIS의 설계 진행과정에서 발견되는 인간공학적 문제점들이 합당할만한 수준으로 해결될 때까지 추적하고 관리하는데 사용된다. NUREG-0711(HFEPRM : Human Factors Engineering Program Review Model)에서는 원자력발전소를 설계함에 있어서 인간공학 현안추적시스템을 유지하고 운영할 것을 요구하고 있다. 본 연구에서 개발한 시스템은 NUREG-0711의 요구사항을 수용할 뿐만 아니라 서류문서형태에 전적으로 의존하는 현안추적시스템을 운영할 때 발생할 수 있는 비효율성, 즉 시간과 경비의 소요, 문서관리의 부담, 중복된 문서내용 등과 같은 부작용을 해소시켜 준다. 또한, MMIS 설계와 관련된 설계조직 구성원들이 인간공학 현안의 내용과 해결 진척사항에 대한 전반적인 정보를 효과적으로 획득하게 지원한다.

  • PDF

DCS-GRAPHIC 설계로 인한 원자력발전소 터빈운전원의 운전능력 향상

  • 박종범;양승권
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.401-406
    • /
    • 1997
  • 발전소 기동 및 저출력 운전시 원자력발전소(PWR) 터빈운전원(T/O)들은 증기발생기 수위제어를 위해 배전반(MCR)에 증기발생기 수위제어 관련 경험이 있는 운전원 3명 이상이 좁은 보드앞에서 각자 S/G A, B, C의 주요 파라미터들을 감시하며 수동운전하게 된다. 이렇게 운전원들이 많은 위험부담을 안고 수동운전하는 이유는 증기발생기 수위제어는 증기발생기 내부의 광역수위 측정범위가 약 14.2(m)이고, 주요 제어변수를 측정하는 협역수위는 약 3.2(m)로 매우 적어서 물의 Swell, Shrink 현상과 급수온도의 영향으로 제어하기 매우 어렵기 때문이다. 그러나 DCS(Distributed Control System)내의 한 부분인 공정감시제어를 위한 MMI(Man Machine Interface) Software를 사용하면 한사람이 증기발생기 수위제어 전 계통의 감시 및 제어가 가능하게 된다. 또한 과거나 현재의 변화 추이 및 문제점 분석은 물론, 계통의 결함 발생시 경보가 발생하여 경보발생 화면을 선택할 경우 어느 부분에서 결함이 발생했는지를 보여준다. 만약 이 화면을 운전원이 아닌 현장 Engineer가 보았을 경우는 결함부분의 확인 및 결함카드 보수가 가능하여 운전원들의 작업부담 감소와 이로 인한 다른 계통 점검 시간을 충분히 확보할 수 있다.

  • PDF