• 제목/요약/키워드: maintenance dose

검색결과 169건 처리시간 0.028초

N-methyl-D-aspartate (NMDA) and Non-NMDA Receptors are Involved in the Production and Maintenance of Nociceptive Responses by Intraplantar Injection of Bee Venom and Melittin in the Rat

  • Kim, Jae-Hwa;Shin, Hong-Kee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제9권3호
    • /
    • pp.179-186
    • /
    • 2005
  • Whole bee venom (WBV) and its major component, melittin, have been reported to induce long-lasting spontaneous flinchings and hyperalgesia. The current study was designed to elucidate the peripheral and spinal mechanisms of N-methyl-D-aspartate (NMDA) and non-NMDA receptors by which intraplantar (i.pl.) injection of WBV and melittin induced nociceptive responses. Changes in mechanical threshold and flinching behaviors were measured after the injection of WBV (0.04 mg or 0.1 mg/paw) and melittin (0.02 mg or 0.05 mg/paw) into the mid-plantar area of a rat hindpaw. MK-801 and CNQX (6-cyano-7-nitroquinoxaline-2,3-dione disodium) were administered intrathecally (i.t. $10{\mu}g$) or i.pl.($15{\mu}g$) 15 min before or i.t. 60 min after i.pl. WBV and melittin injection. Intrathecal pre- and postadministration of MK-801 and CNQX significantly attenuated the ability of high dose WBV and melittin to reduce paw withdrawal threshold (PWT). In the rat injected with low dose, but not high dose, of WBV and melittin, i.pl. injection of MK-801 effectively suppressed the decrease of PWTs only at the later time-points, but the inhibitory effect of CNQX (i.pl.) was significant at all time-point after the injection of low dose melittin. High dose WBV- and melittin-induced spontaneous flinchings were significantly suppressed by i.t. administration of MK-801 and CNQX, and low dose WBV- and melittin-induced flinchings were significantly reduced only by intraplantarly administered CNQX, but not by MK-801. These experimental flinchings suggest that spinal, and partial peripheral mechanisms of NMDA and non-NMDA receptors are involved in the development and maintenance of WBV- and melittin-induced nociceptive responses.

원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석 (An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.176-183
    • /
    • 2009
  • 원전 계획예방정비기간 증기발생기 수실작업 등은 매우 높은 방사선량율을 보이는 지역으로, 짧은 시간 동안 작업으로 종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉작업을 하는 손 부위에서 고피폭이 예상된다. 이런 점을 고려하여 2004년 수행된 국내 원전의 복수선량계 알고리즘 적용성 시험의 TLD 판독결과를 이용하여 고피폭 접촉 작업의 방사선장을 분석하였다. 그 결과, 원전 고피폭 접촉작업의 입사방사선장은 고에너지 광자(High Energy Photon Field)에 의한 피폭으로 해석되었다. 한편 2009년 울진 4호기 계획예방정비기간 S/G 정비작업과 월성 1호기 압력관 교체작업에 참여한 방사선작업종사자에 대해 말단선량 현황과 방사선장을 분석하기위한 현장시험을 실시하였다. 그 결과 입사방사선장은 고에너지 방사선장으로 확인되었다.

한국인 소아에서 만성 기능성 변비치료 시 전해질이 함유되지 않은 PEG 4000의 유지용량 (Maintenance dose of electrolyte free polyethylene glycol (PEG) 4000 in Korean children with chronic functional constipation)

  • 이소희;배선환
    • Clinical and Experimental Pediatrics
    • /
    • 제50권12호
    • /
    • pp.1212-1216
    • /
    • 2007
  • 목 적 : 최근들어 전해질이 함유되지 않은 PEG 4000제재는 변비 치료제로 성인이나 소아에서 새롭게 사용되기 시작하였다. 본 연구는 한국인 소아 만성기능성 변비 환아 치료 시 유지요법 단계에서 전해질이 함유되지 않은 PEG 4000제재의 연령 및 체중별 적정 투여 시작 량을 추정함과 동시에 그 효과 및 안정성을 평가하였다. 방 법 : 2005년 8월부터 2007년 6월까지 건국대학교 서울병원 소아과에서 만성 기능성 변비로 진단하고 분변박힘 제거과정을 마친 후 PEG4000을 3개월 이상 사용한 환아 가운데 41명을 대상으로 하였다. 배변을 편하게 하면서 배변 횟수가 주당 5-6회 이상이면서 변 굳기가 정상(보통변 또는 무른변)인 상태가 2개월 이상 유지되는 초기용량을 효과적 유지요법 용량으로 정의하였다. 약제사용에 대한 배변내용(배변횟수, 변의 굳기, 배변시 출혈 등)의 분석은 부모나 환아가 작성한 배변일기의 기록을 바탕으로 시행되었다. 약제 사용과 관련된 부작용은 임상적 및 진단검사의학적으로 관찰하였다. 결 과 : 전체 환아를 대상으로 분석된 효과적 유지요법의 평균 용량은 $0.55{\pm}0.16g/kg/day$(0.25-0.86) 이었다. 환아의 연령에 따라 3-5세, 6-8세, 9-13세의 세 집단으로 나누어 효과적 유지요법의 평균 용량을 구하였을 때, 각각 $0.60{\pm}0.15$(0.33-0.86), $0.57{\pm}0.16$(0.38-0.76), $0.44{\pm}0.14$(0.25-0.70) g/kg/day 이었으며, 이들 사이에는 통계적으로 유의한 차이를 보였다(P=0.024). 체중에 따라서 효과적 유지용량을 산출하였을 때, 30 kg 미만인 군의 효과적 유지요법의 평균 용량은 $0.62{\pm}0.14g/kg/day$(0.33-0.86) 이었으며, 30 kg 이상인 군의 효과적 유지요법의 평균 용량은 $0.41{\pm}0.10g/kg/day$(0.25-0.65)이었으며, 통계적으로 유의한 차이를 보였다(P=0.001). 유지요법동안 공복 복용 시 속이 쓰리다고 호소한 한명의 경우 외에는 임상적으로 부작용은 관찰되지 않았다. 결 론 : 한국인 소아에서 만성 기능성 변비치료 시 전해질이 함유되지 않은 PEG 4000제재는 안전하고 효과적이다. 유지용량은 0.55 g/kg/day로 시작하는 것이 적절한 것으로 생각되고, 이는 환아의 연령이나 체중을 바탕으로 조정되어질 수 있다.

고방사선장내 작업 로봇용 이중 방사선 감지 시스템 (A Dual Radiation Monitoring System Ror Robot Working in High Radiation Field)

  • 이남호;조재완;김승호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.556-558
    • /
    • 2005
  • The effect of high irradiation on inspection systems in a nuclear power plant can be severe, especially to electronic components such as control hoards. The effect may lead to a critical malfunction or trouble to a underwater robot for inspection and maintenance of nuclear reactor. However, if information on the total accumulated dose on the sensitive parts of the robot is available, a prediction of robot's behavior in radiation environments becomes possible. To know how much radiation the robot has encountered, a dosimeter to measure the total accumulated dose is necessary. This paper describes the development effort of a dual radiation monitoring system using a SiC diode as a dose-rate meter and a p-type power MOSFET as a dose meter. This attempt using two sensors which detect same radiation improves reliability and stability at high intensity radiation detection in nuclear facilities. It uses the concept of diversity and redundancy.

전신성 건선환자의 광선치료 후의 임상적 특성에 대한 고찰 (Treatment Result of Photochemotherapy for Systemic Psoriasis Patients)

  • 조은정;이충휘
    • 한국전문물리치료학회지
    • /
    • 제3권1호
    • /
    • pp.73-79
    • /
    • 1996
  • Photochemotherapy(UVA with 8-methoxypsoralen) was given to 30 patients with systemic psoriasis. The results of clearing and long-term(6-month) interval maintenance were reported. Clearing requirements were in general similar to these reported by Melski and Burger. The skin of the 14 patients (46.6%) recovered good skin condition by a once weekly maintenance dose. This result was better than that reported by other authors. 1. During initial treatment period, average number of treatment was 27.3 and average duration treatment was 24.8 weeks. 2. The factors to quit treatment were motion decrease, moving to the remote area, complications, etc. 3. Number of patient who received maintenance treatment was 14. 4. The complications reported from the patients were hyperpigmentation, nausea, headache, pruritis, vomiting, gastritis.

  • PDF

Radiation Measurement of a Operational CANDU Reactor Fuel Handling Machine using Semiconductor Sensors (ICCAS 2003)

  • Lee, Nam-Ho;Kim, Seung-Ho;Kim, Yang-Mo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1220-1224
    • /
    • 2003
  • In this paper, we measured the radiation dose of a fuel handling machine of the CANDU type Wolsong nuclear reactor directly during operation, in spite of the high radiation level. In this paper we will describe the sensor development, measurement techniques, and results of our study. For this study, we used specially developed semiconductor sensors and matching dosimetry techniques for the mixed radiation field. MOSFET dosimeters with a thin oxide, that are tuned to a high dose, were used to measure the ionizing radiation dose. Silicon diode dosimeters with an optimum area to thickness ratio were used for the radiation damage measurements. The sensors are able to distinguish neutrons from gamma/X-rays. To measure the radiation dose, electronic sensor modules were installed on two locations of the fuel handling machine. The measurements were performed throughout one reactor maintenance cycle. The resultant annual cumulative dose of gamma/X-rays on the two spots of the fuel handling machine were 18.47 Mrad and 76.50 Mrad, and those of the neutrons were 17.51 krad and 60.67 krad. The measured radiation level is high enough to degrade certain cable insulation materials that may result in electrical insulation failure.

  • PDF

OPERATIONAL EXPERIENCE OF A TWO-DOSIMETER ALGORITHM FOR BETTER ESTIMATION OF EFFECTIVE DOSE AT KOREAN NUCLEAR POWER PLANTS

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.165-169
    • /
    • 2009
  • Two dosimeters are provided to radiation workers participating in tasks where high radiation exposure is expected during maintenance at nuclear power plants. At Korean nuclear power plants, two dosimeters are currently provided for tasks where exposure rates exceed 1 mSv/hr, the difference of equivalent dose to specific parts of the body is more than 30% and an exposure of more than 2 mSv is expected in a single task. These conditions for the provisioning of two dosimeters are based on previous field test results, and it is recommended that the dosimeters be worn on the chest and back. It was also found that the workers felt it was more convenient when they wore two dosimeters on chest and back rather than on chest and head. After the application of previous field test results to practice, it was found that the calculated effective dose for workers during radiation work was lower than the maximum dose of chest or back dosimeter by approximately 10%-30%. This performance is regarded not only to meet the international guideline but also to provide convenience for workers during radiation work.

Use of Rank Sum Method in Identifying High Occupational Dose Jobs for ALARA Implementation

  • Cho, Yeong-Ho;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.444-451
    • /
    • 1998
  • The cost-effective reduction of occupational radiation exposure (ORE) dose at a nuclear power plant could not be achieved without going through an extensive analysis of accumulated ORE dose data of existing plants. It is necessary to identify what are high ORE jobs for ALARA implementation. In this study, the Rank Sum Method (RSM) is used in identifying high ORE jobs. As a case study, the database of ORE-related maintenance and repair jobs for Kori Units 3 and 4 is used for assessment, and top twenty high ORE jobs are identified. The results are also verified and validated using the Friedman test, and RSM is found to be a very efficient way of analyzing the data.

  • PDF

인조판막 이식후의 난소혈종 1예 (Ovarian Hematoma After Double Valve Replacement -A Report of Case-)

  • 안광필;노준량;김종환;서경필;이영균
    • Journal of Chest Surgery
    • /
    • 제9권2호
    • /
    • pp.215-219
    • /
    • 1976
  • Anticoagulation therapy with Warfarin and Dipyridamole is useful after prosthetic heart valve replacement for the prevention of thromboembolic accidents. Here presented a case of right ovarian hematoma, 41 years old, female who has been already treated double valve replacement due to mitral insufficiency with 27 mm $Bj{\ddot{o}}rk-Shiley$ mitral, and 29 mm Hancock tricuspid valve successfully on 27th, April, 1976. Just after the operation, patient was treated the anticoagulation therapy with Dipyridamole 300 mg, and Heparin, and later switched to Warfarin 3.75 mg or 5 mg po, as the maintenance dose. Three and half months after the anticoagulation therapy, patient complained the lower abdominal pain and vaginal spotting and which revealed right ovarian hematoma due to ovulation, manifested due to anticoagulation therapy. Patient was discharged postoperative 15 th day with the maintenance dose 5 mg Warfarin and Dipyridamole 300mg po to maintain the prothrombin time 30%, after the uterus and both. ovaries and both adnexae are resected out for the prevention of the further hemorrhage of ovary.

  • PDF