• 제목/요약/키워드: main tunnels

검색결과 116건 처리시간 0.02초

서울시 지하철 2호선 본선구간의 입자상물질 농도 특성 및 미세분진의 오염지도 개발 (Characterizing Par ticle Matter on the Main Section of the Seoul Subway Line-2 and Developing Fine Particle Pollution Map)

  • 이은선;박민빈;이태정;김신도;박덕신;김동술
    • 한국대기환경학회지
    • /
    • 제32권2호
    • /
    • pp.216-232
    • /
    • 2016
  • In present, the Seoul City is undergoing traffic congestion problems caused by rapid urbanization and population growth. Thus the City government has reorganized the mass transportation system since 2004 and the subway has become a very important means for public transit. Since the subway system is typically a closed environment, the indoor air quality issues have often raised by the public. Especially since a huge amount of PM (particulate matter) is emitted from ground tunnels passing through the subway train, it is now necessary to assess the characteristics and behaviors of fine PM inside the tunnel. In this study, the concentration patterns of $PM_1$, $PM_{2.5}$, and $PM_{10}$ in the Seoul subway line-2 were analyzed by real-time measurement during winter (Jan 13, 2015) and summer (Aug 7, 2015). The line-2 consisting of 51 stations is the most busy circular line in Seoul having the railway of 60.2 km length. The the one-day average $PM_{10}$ concentrations were $148{\mu}g/m^3$ in winter and $66.3{\mu}g/m^3$ in summer and $PM_{2.5}$ concentrations were $118{\mu}g/m^3$ and $58.5{\mu}g/m^3$, respectively. The $PM_{2.5}/PM_{10}$ ratio in the underground tunnel was lower than the outdoor ratio and also the ratio in summer is higher than in winter. Further the study examined structural types of underground subsections to explain the patterns of elevated PM concentrations in the line-2. The subsections showing high PM concentration have longer track, shorter curvature radius, and farther from the outdoor stations. We also estimated the outdoor PM concentrations near each station by a spatial statistical analysis using the $PM_{10}$ data obtained from the 40 Seoul Monitoring Sites, and further we calculated $PM_{2.5}/PM_{10}$ and $PM_1/PM_{10}$ mass ratios near the outdoor subway stations by using our observed outdoor $PM_1$, $PM_{2.5}$, and $PM_{10}$ data. Finally, we could develop pollution maps for outdoor $PM_1$ and $PM_{2.5}$ near the line-2 by using the kriging method in spatial analysis. This methodology may help to utilize existing $PM_{10}$ database when managing and control fine particle problems in Korea.

논문 취소: 터널형 구조물의 방재시설 가동에 따른 화재연기 거동에 관한 수치 해석적 연구 (Retraction: A numerical study on the fire smoke behavior by operating the fire prevention system in tunnel-type structure)

  • 이호형;최판규;이상돈;허원호;조종복
    • 한국터널지하공간학회 논문집
    • /
    • 제21권1호
    • /
    • pp.189-199
    • /
    • 2019
  • 본 연구에서는 배연댐퍼 또는 제트팬과 같은 방재시설이 설치된 터널형 구조물(방음터널)에 대하여 방재시설 가동에 따른 화재연기의 거동을 수치해석적으로 고찰하고 해석결과를 비교 검토하여 다음과 같은 결론을 얻었다. 화재차량 천장부 개방 유무에 따라 방음터널 내 화재양상이 확연하게 달라지는 것을 확인하였으며, 방음터널의 주요 자재인 PC와 PMMA의 임계온도를 초과하지 않는 것으로 나타났다. 또한 배연댐퍼의 설치간격에 따른 해석결과, 방음터널 내 발생하는 최대 온도가 미설치시에는 최대 $552^{\circ}C$인 반면, 설치간격이 50 m인 경우에는 $405^{\circ}C$로 나타났으며, 제트팬 가동 여부에 따른 해석결과, 방음터널 내 발생하는 최대 온도는 제트팬 미가동시에는 $549^{\circ}C$인 반면, 가동시에는 $86^{\circ}C$로 나타나 화재시 피난환경과 방음자재보호에 있어 매우 유리한 환경을 조성할 것으로 예상되며, 향후 다양한 목적을 가진 터널을 대상으로도 이러한 기초연구의 활성화가 필요할 것으로 사료된다.

지반조건과 지진파를 고려한 해저철도 터널의 동적 수치 모델링 (Dynamic Numerical Modeling of Subsea Railway Tunnel Based on Geotechnical Conditions and Seismic Waves)

  • 곽창원;유민택
    • 한국지반공학회논문집
    • /
    • 제38권11호
    • /
    • pp.69-86
    • /
    • 2022
  • 철도는 정시성과 수송능력을 갖춘 여객 및 물류 운송 수단으로서 널리 사용되고 있다. 근래의 급격한 건설기술의 발전으로 철도는 대륙과 대륙, 대륙과 섬을 잇는 다양한 해저철도의 건설이 계획되고 있으며 국내에는 보령 해저터널(2021), 가덕 해저터널(2010) 등 유사 설계 및 시공 경험이 축적되고 있다. 그러나 최근 국내외적으로 다양한 규모의 지진이 빈번하게 발생함에 따라 지진위험에 대한 인식이 증대되고 있으며, 국내 지진의 발생빈도 또한 증가하고 있다. 해저터널에 대한 지진의 영향은 매우 복잡하나 주로 지반조건, 지진하중 등에 의하여 큰 차이를 보일 수 있다. 본 연구에서는 외부수압이 작용하는 가상의 해저철도 쉴드터널에 대하여 지반구성과 지진파 의한 영향을 파악하기 위하여 토사, 암반, 복합지반 및 파쇄대로 구성된 4 가지 지반조건을 반영한 3차원 수치해석 모델을 구축하였다. 각 해석 모델에 대하여 장주기, 단주기, 그리고 장단주기 특성을 모두 가지는 인공지진파를 각각 적용하여 유한차분해석법에 의한 동적해석을 수행하여 변위 및 터널 부재력 응답을 검토하였다. 그 결과 터널 변위는 토사지반에서 터널 진행방향에 연직방향 지진하중이 작용 시 장주기파의 영향이 우세하고 암반지반에서는 단주기파의 영향이 우세한 결과를 얻었다. 또한 국부적 취약구간인 파쇄대에서는 인공지진파의 영향이 우세하였다. 터널 세그먼트의 부재력 검토 결과 지반 및 세그먼트의 구속효과로 인하여 지진하중이 변위보다 부재력에 미치는 영향이 크게 나타남을 확인하였다. 

유도파를 이용한 시간-주파수 영역 해석을 통한 록볼트 건전도 실험의 경암지반 현장 적용성 평가 (Rock Bolt Integrity Assessment in Time-Frequency Domain : In-situ Application at Hard Rock Site)

  • 이인모;한신인;민복기;이종섭
    • 한국지반공학회논문집
    • /
    • 제25권12호
    • /
    • pp.5-12
    • /
    • 2009
  • 록볼트는 터널과 지하공간 구조물의 시공에 있어서 주요 지보재 중 하나이며, 이러한 록볼트의 건전도가 전체 구조물의 안정성에 큰 영향을 미치게 되었다. 본 연구의 목적은 실제 현장에서 투과법을 적용하여 록볼트를 따라 전파되는 유도파를 통해 록볼트의 건전도를 평가하는 것이다. 비파괴 실험의 각기 다른 결함비율을 가진 록볼트 시험체를 제작하여 콘크리트 블록 및 실제현장에 매설한 후, 피에조 디스크 엘리먼트로 유도파를 발생시키고 AE(acoustic emission) 센서를 이용하여 신호를 측정하였다. 수집된 신호는 가버 웨이브렛을 사용한 웨이브렛 변환을 이용하여 시간-주파수 영역에서 분석하였다. 시간-주파수 영역에서의 각 파군별 최대 에너지가 나타나는 지점의 시간차는 각 반사파군 간의 이동 시간차를 나타내며, 이를 통해 계산된 유도파의 에너지 속도는 록볼트의 결함비율이 증가함에 따라 증가하는 것으로 나타났다. 실험에 적합한 양생기간을 제안하였으며 그에 따른 두 번의 현장 실험을 통해 록볼트 건전도 실험의 현장 적용성을 검토하였고, 제안된 실험방법이 록볼트의 건전도 평가에 있어서 유용한 평가방안임을 확인하였다.

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

군말뚝 기초 하부 병렬터널 굴착 시 전단변형 거동 특성 (Shear strain behaviour due to twin tunnelling adjacent to pile group)

  • 김수빈;오영석;이용주
    • 한국터널지하공간학회 논문집
    • /
    • 제26권1호
    • /
    • pp.59-78
    • /
    • 2024
  • 현재 터널 시공 시 인접 구조물 및 지반의 침하를 기준으로 안정성을 평가하고 있지만, 지반의 전단변형은 터널 굴착 및 작용하중 변화에 따른 지반의 파괴메커니즘을 결정짓는 주요 인자로서 터널 굴착 시 안정성 검토 및 보강영역 산정에 활용할 수 있다. 본 연구에서는, 실내모형시험을 통해 도심지 연약지반에 병렬터널 굴착을 모사하여 병렬터널 굴착이 인접한 군말뚝 기초 및 인접 지반에 미치는 거동에 대해 분석하였다. 실내모형시험 시 근거리 사진계측을 활용하여 지중의 변위 및 지반의 전단변형을 구하고, 이를 바탕으로 2차원 유한요소 수치해석을 수행하였다. 역해석 결과 병렬터널의 필라부 수평이격거리 및 군말뚝 기초 선단부와 터널 천단부 사이 수직이격거리가 증가할수록 최대전단변형률이 감소하는 경향을 보였다. 필라부 수평이격거리가 증가할수록 두 번째 터널에 의해 첫 번째 터널 및 군말뚝 기초에 미치는 영향이 줄어들었다. 또한, 필라부 수평이격거리보다 군말뚝 기초 선단부와 터널 천단부 사이 수직이격거리가 지반의 전단변형률 결과에 미치는 영향이 상대적으로 더 큰 것으로 나타났다. 근거리사진계측과 수치해석 결과 인접 군말뚝 및 인접 지반의 침하는 설계 기준 이내로 측정되었으나, 지반의 전단변형률은 모든 Case에서 미소변형 범위를 벗어나 보강이 필요한 것으로 판단된다.