• 제목/요약/키워드: main line

검색결과 2,237건 처리시간 0.035초

열차의 곡선주행능 해석에 관한 연구 (A Study on the Analysis of Curving Performance of Railway Vehicle)

  • 김도중;박삼진
    • 한국기계연구소 소보
    • /
    • 통권14호
    • /
    • pp.101-110
    • /
    • 1985
  • Kyung-p-1 main line is characterized by its curves radii of which are considerably small. It is essential for running time reduction of train to improve capabilities of curve negotiation. This improvement can be achieved by designing a bogie with flexible suspension system. The effect of the improvement is mainly concerned in the primary yaw stiffness of bogie suspension. This paper gives a linear analysis for the motion of railway vehicle on curved track and gives also computer simulation results for Semaul Train. The results introduce a conclusion that the primary yaw stiffness of Semaul train is too rigid to be self-steering on Kyung-pu main line curves.

  • PDF

주증기관 파단사고에 대한 원자로 용기의 가압열충격 해석 (Pressurized Thermal Shock Analyses of Reactor Pressure Vessel for Main Steam Line Break)

  • 정명조;박윤원;장창희;정일석
    • 한국전산구조공학회논문집
    • /
    • 제12권3호
    • /
    • pp.271-279
    • /
    • 1999
  • 본 연구에서는 국내에서 가장 취약할 것으로 예상되는 원자력 발전소에 가압열충격 사고를 유발할 수 있는 주증기관 파단사고를 가정하여 열수력 해석과 파괴역학 해석을 수행하였다. 원전수명관리연구의 일환으로 계통열수력 해석 및 혼합열유동 해석에 의하여 구한 냉각제의 온도와 압력의 이력 및 용기의 재질성분으로부터 용기의 응력확대계수와 파괴인성치를 계산하고 이들을 비교하여 균열의 진전여부를 판단하여 형상계수가 1/6인 표면균열이 견딜 수 있는 최대 기준무연성천이온도를 결정하였다.

  • PDF

ZCS 보조회로를 이용한 ZVT Boost 컨버터에 관한 연구 (A Study on ZVT Boost Converter Using a ZCS Auxiliary Circuit)

  • 류동균;이우석;최태영;서민성;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.129-132
    • /
    • 2001
  • Recently, a ZVT boost converter is embedded in a power factor correction system. The control circuit of the converter assures soft-switching for all the MOSFETs and load regulation. The PFC system contains additional control circuits which assure the input voltage in a sinusoidal form and feed-forward line voltage regulation. In this paper, a soft switching boost converter with zero-voltage transition(ZVT) main switch using zero-current switching(ZCS) auxiliary switch is proposed. Operating intervals of the converter are persented and analyzed. The proposed results show that the main switch maintains UT while auxiliary switch retains ZCS for the complete specified line and load conditions.

  • PDF

배전용 변전소 주변압기 중성점에 초전도 전류제한기 적용시 전류제한특성 분석 (Limiting Current Characteristics using Superconducting Fault Current Limiter on Neutral Line of Main Transformer in Distribution Substation)

  • 김진석;김명후;유일경;문종필;임성훈;김재철;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.14_15
    • /
    • 2009
  • In this paper, the effect of SFCL which was applied on neutral line of main transformer in distribution substation was analyzed in addition to the position of SFCL among some cases which are studied. The result about the limiting current was compared with the effect with SFCL applied on feeder. The limiting current characteristics are similar to the effect of SFCL on feeder. Therefore, this application of SFCL is required to protection coordination such as SFCL is applied on feeder.

  • PDF

양수발전소 발전-전동기 운전중 감시 시스템의 개발 (Development of On-Line Monitoring System for Pumped Storage Generator/Motor)

  • 김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

A Novel Boost PFC Converter Employing ZVS Based Compound Active Clamping Technique with EMI Filter

  • Mohan, P. Ram;Kumar, M. Vijaya;Reddy, O.V. Raghava
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권1호
    • /
    • pp.85-91
    • /
    • 2008
  • A Boost Power Factor Correction (PFC) Converter employing Zero Voltage Switching (ZVS) based Compound Active Clamping (CAC) technique is presented in this paper. An Electro Magnetic Interference (EMI) Filer is connected at the line side of the proposed converter to suppress Electro Magnetic Interference. The proposed converter can effectively reduce the losses caused by diode reverse recovery. Both the main switch and the auxiliary switch can achieve soft switching i.e. ZVS under certain condition. The parasitic oscillation caused by the parasitic capacitance of the boost diode is eliminated. The voltage on the main switch, the auxiliary switch and the boost diode are clamped. The principle of operation, design and simulation results are presented here. A prototype of the proposed converter is built and tested for low input voltage i.e. 15V AC supply and the experimental results are obtained. The power factor at the line side of the converter and the converter efficiency are improved using the proposed technique.

시선지령식 유도방법을 사용한 유도무기시스템의 오차해석 (Error analysis of a missile system with command to line-of-sight guidance law)

  • 이규택;이연석;이장규;장상근
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.389-394
    • /
    • 1991
  • The surface-to-air missile system using Command to Line-Of-Sight (CLOS) guidance law is represented by complex nonlinear differential equations with 6 degree-of-freedom. This paper presents the characterictics of missile system and the effect of various error sources by Monte-Carlo simulation method. By simulation the part of playing a main role in the surface-to-air missile system is radar. Therefore for the performance of missile system the development of the technique reducing the error of radar is required. And the effect of accelerometer error is a few large, too. But, because accelerometer costs cheap this problem is solved easily. And the main error source of missile system data is the thrust, which affects directly to acceleration. The result is the important information about designing and fabricating missile system. And this makes the missile system best because of sharing elaborate and expense effectively.

  • PDF

차세대 원자로 용기내 vessel 내면에서의 대류 열전달특성에 관한 수치해석적 연구 (A numerical study on convective heat transfer characteristics at the vessel surface of the Korean Next Generation Reactor)

  • 정삼두;김창녕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.228-233
    • /
    • 2000
  • The Korean Next Generation Reactor(KNGR) is a Pressurized Water Reactor adopting direct vessel injection(DVI) to optimize the performance of emergency core cooling system(ECCS). In a certain accident, however, pressurized thermal shock(PTS) of the vessel due to the sudden contact with the injected cold water is expected. In this paper, an accident of Main Steam Line Break(MSLB) has been numerically investigated with direct vessel injections and an increased volume flow rate in some cold legs. Using FLUENT code, temperature distributions of the fluid in the downcomer and of reactor vessel including the core region have been calculated, together with the distribution of convective heat transfer coefficient(CHTC) at the cladding surface of the reactor vessel. The result shows that some parts of the core region of the reactor vessel have higher temperature gradient expressing higher thermal stress.

  • PDF

마이크로컴퓨터를 이용한 온-라인 측정 시스템의 개발 (Development of microcomputer-based on-line measurement system.)

  • 정명균;이정운
    • 대한기계학회논문집
    • /
    • 제5권4호
    • /
    • pp.274-283
    • /
    • 1981
  • An inexpensive and very simple microcomputer-aided measurement system has been designed for on-line experiments, which perform simultaneously data acquisition, data recorditing, calculations with the data, and positioning of necessary sensors. Interfacting between the microcomputer and the data acquisition board which consists of A/D converter, analog multiplexer, and sample-and-holder, etc. has been done through IEEE-488 interface port and parallel user port both provided by the PET computer's main logic board. Data and control signals are transfered between devices without handshaking. By utilizing BASIC commands PEEK, POKE, SYS, USR which are offered by PET microcomputer, it is possible to link machine code subroutines into the main BASIC program. This facilitates ease of data transfer, programming, and speedy execution of the program. In addition, an X-Y scanning table has been concected to the system in order to automatically position measuring sensors along a pre-determined path of interest.

Numerical Simulation of Directional Spreading Characteristics in a Snake Type Wave Generator considering Side Wall Reflection

  • Lee, Jin-Ho;Hirayama, Tsugukiyo
    • Journal of Ship and Ocean Technology
    • /
    • 제4권1호
    • /
    • pp.28-36
    • /
    • 2000
  • Numerical simulation based on the superposition of ring waves generated by the linear periodic source distributions for the plunger type wave maker was accomplished. The characteristics of directional spreading function were investigated. Mirror images are also introduced to consider reflections of side-wall together with the reflection coefficient to account for the imperfect reflection from the real side wall in the long experimental towing tank. Unexpected spurious waves, resulting from the combined effect of finite breadth of segmented wave maker, wavelength and main wave maker, wavelength and main wave propagating direction, were observed in the line source method and also in the analysis of the directivity. The influence of spurious waves to the directional spreading function was also investigated.

  • PDF