• Title/Summary/Keyword: main control room alarm

Search Result 4, Processing Time 0.016 seconds

Development of Plant Abnormal Status Response System by Multi-Alarm Pattern in Main Control Room (원자력발전소 주제어실 다중 경보 패턴에 의한 경보/비정상 대응 체계 개발)

  • Choi, Sun Yeong;Jung, Wondea
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.129-135
    • /
    • 2014
  • The number of abnormal operation procedures (AOPs) for mitigating a plant abnormal status amounts to about one hundreds for the most of 1000MWe optimized power plant (OPR1000) and it is expected that the number of AOPs would be increased to cope with an abnormal status occurred newly. However, it is not well organized for operators to select a proper AOP from alarms occurred in main control room (MCR) during a plant abnormal status. It may be a burden to operators since the selection of AOP to respond an abnormal status is authorized by operators. When multiple alarms occur in MCR, it would take more time to respond them than a single alarm. To reduce the efforts, various MCR operation support systems have been developed. The purpose of this study was to develop a multi-alarm pattern card to select an appropriate AOP effectively when multiple alarms occurs in a single upper layout (UL) of MCR. It can be applied for an operation support tool as well as an education tool.

Intelligent Software System for the Advanced Control Room of a Nuclear Power Plant

  • Chang, Soon-Heung;Park, Seong-Soo;Park, Jin-Kyun;Gyunyoung Heo;Kim, Han-Gon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.443-448
    • /
    • 1997
  • The intelligent software system for nuclear power plants (NPPs) has been conceptually designed in this study. Its design goals are to operate NPPs in n improved manner and to support operators' cognitive tasks. It consists of six major modules such as "Information Processing," "Alarm Processing," "Procedure Tracking," "Performance Diagnosis," and "Event Diagnosis" modules for operators and "Malfunction Diagnosis" module for maintenance personnel. Most of the modules have been developed for several years and the others are under development. After the completion of development, they will be combined into one system that would be main parts of advanced control rooms in NPPs. that would be main parts of advanced control rooms in NPPs.

  • PDF

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.3
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System (전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구)

  • Kang, Chang-Soo;Kang, Ki-Seong
    • 전자공학회논문지 IE
    • /
    • v.46 no.4
    • /
    • pp.25-30
    • /
    • 2009
  • The cooling water circulation pipes had been used to drop the temperature of refractory outside shell of blast furnace by cooling plate or stave type. They were attacked by surrounding CO gas and it was the cause that they were corroded and the water inflow in the refractory due to leakage of water. So, the life of refractory material was shorten and changed for the worse the conditions of blast furnace. The automatic sensing device for water leakage of cooling pipe was developed to check the position of trouble by use the micro-process system when cooling water leak and then CO gas will be inflowed into the cooling pipe at the leakage position. The inflowed CO gas will be detected in the micro-process system and delivered the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave the water leakage part immediately and then deliver the signal to main control room by use the micro-process system and wireless-radio relay station. This system will develop the working condition from manual system to unmanned auto alarm system.