• 제목/요약/키워드: main control room alarm

검색결과 4건 처리시간 0.017초

원자력발전소 주제어실 다중 경보 패턴에 의한 경보/비정상 대응 체계 개발 (Development of Plant Abnormal Status Response System by Multi-Alarm Pattern in Main Control Room)

  • 최선영;정원대
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.129-135
    • /
    • 2014
  • The number of abnormal operation procedures (AOPs) for mitigating a plant abnormal status amounts to about one hundreds for the most of 1000MWe optimized power plant (OPR1000) and it is expected that the number of AOPs would be increased to cope with an abnormal status occurred newly. However, it is not well organized for operators to select a proper AOP from alarms occurred in main control room (MCR) during a plant abnormal status. It may be a burden to operators since the selection of AOP to respond an abnormal status is authorized by operators. When multiple alarms occur in MCR, it would take more time to respond them than a single alarm. To reduce the efforts, various MCR operation support systems have been developed. The purpose of this study was to develop a multi-alarm pattern card to select an appropriate AOP effectively when multiple alarms occurs in a single upper layout (UL) of MCR. It can be applied for an operation support tool as well as an education tool.

Intelligent Software System for the Advanced Control Room of a Nuclear Power Plant

  • Chang, Soon-Heung;Park, Seong-Soo;Park, Jin-Kyun;Gyunyoung Heo;Kim, Han-Gon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.443-448
    • /
    • 1997
  • The intelligent software system for nuclear power plants (NPPs) has been conceptually designed in this study. Its design goals are to operate NPPs in n improved manner and to support operators' cognitive tasks. It consists of six major modules such as "Information Processing," "Alarm Processing," "Procedure Tracking," "Performance Diagnosis," and "Event Diagnosis" modules for operators and "Malfunction Diagnosis" module for maintenance personnel. Most of the modules have been developed for several years and the others are under development. After the completion of development, they will be combined into one system that would be main parts of advanced control rooms in NPPs. that would be main parts of advanced control rooms in NPPs.

  • PDF

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구 (A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제46권4호
    • /
    • pp.25-30
    • /
    • 2009
  • 용광로는 외피 부분에 내부 내화물의 온도를 낮추기 위하여 냉각수를 공급하는 냉각판 또는 스테이브를 사용하고 있다. 주변 조업 조건의 열악으로 냉각수를 공급하는 배관의 부식으로 냉각수가 내화물에 침투하여 내화물의 수명을 떨어뜨리고, 노황을 악화시키는 원인이 되고 있다. 이에 본 연구는 용광로 냉각설비장치에 이상 현상이 발생하였을 때 위치를 정확히 확인함에 따라 신속하게 누수된 부위를 파악하여 대처할 수 있는 기능을 갖춘 냉각관 누수 자동감지장치를 개발하였다. 주된 연구는 전자제어 장치인 마이크로프로세서를 응용한 전자변 제어장치를 이용하여 냉각설비의 파손으로 발생되는 누수현상으로 인한 고열과 분진 일산화탄소 등의 산출로 작업환경의 재해를 자동방지 하고자 하였으며, 작업환경이 친환경적이며 작업의 가치를 재창출할 수 있는 방법들이 연구되고 있다. 용광로 분위기의 일산화탄소 자동 감지장치와 그에 따른 출력신호를 자동 전송하는 무선중계기 장치를 개발함으로 용광로 냉각설비 장치의 분위기 작업환경을 수동방식에서 무인자동화방식으로 개선하였다.