SLS 공정에서 최적 공정 조건 도출을 위한 실험적 연구 (An Experimental Study for Drawing of Optimal Process Condition in the SLS Process)

  • 배성우;유성연;김동수
    • 한국생산제조학회지
    • /
    • 제21권3호
    • /
    • pp.516-524
    • /
    • 2012
  • Selective Laser Sintering(SLS) system consists of various element technologies. Main components of the system include a position control system, a speed control system of the roller, and nitrogen atmosphere furtherance for the powdered sintering. Other systems which make the core of the SLS system are build room and the feed room for powder epitaxial, a temperature control system, and a scan path generator for the laser. The powder material for laser sintering is necessary to produce prototypes in Solid Freeform Fabrication(SFF) based on SLS process. This powder material is sintered in powder room using $CO_2$ laser after spreading evenly using roller to reproduce mold via SFF. This study addresses an SFF system by using the SLS process which applies single laser system to enable manufacturing of 3D shape. And to evaluate applicability of the single laser system, experiments were conducted with optimal fabricating process.

Electrical fire simulation in control room of an AGN reactor

  • Jyung, Jae-Min;Chang, Yoon-Suk
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.466-473
    • /
    • 2021
  • Fire protection is one of important issues to ensure safety and reduce risks of nuclear power plants (NPPs). While robust programs to shut down commercial reactors in any fires have been successfully maintained, the concept and associated regulatory requirements are constantly changing or strengthening by lessons learned from operating experiences and information all over the world. As part of this context, it is necessary not only to establish specific fire hazard assessment methods reflecting the characteristics of research reactors and educational reactors but also to make decisions based on advancement encompassing numerical analyses and experiments. The objectives of this study are to address fire simulation in the control room of an educational reactor and to discuss integrity of digital console in charge of main operation as well as analysis results through comparison. Three electrical fire scenarios were postulated and twenty-four thermal analyses were carried out taking into account two turbulence models, two cable materials and two ventilation conditions. Twelve supplementary thermal analyses and six subsequent structural analyses were also conducted for further examination on the temperature and heat flux of cable and von Mises stress of digital console, respectively. As consequences, effects of each parameter were quantified in detail and future applicability was briefly discussed. On the whole, higher profiles were obtained when Deardorff turbulence model was employed or polyvinyl chloride material and larger ventilation condition were considered. All the maximum values considered in this study met the allowable criteria so that safety action seems available by sustained integrity of the cable linked to digital console within operators' reaction time of 300 s.

KSTAR 전류전송제어시스템의 원격운전을 위한 EPICS 기반 제어계 구축 (Implementation of EPICS based control system for KSTAR Current Lead System)

  • 김명규;백설희;김국희;박미경
    • 한국진공학회지
    • /
    • 제17권1호
    • /
    • pp.58-66
    • /
    • 2008
  • KSTAR 전류전송제어시스템은 네트워크기반의 실시간 분산제어시스템으로 EPICS (Experimental Physics and Industrial Control System)를 미들웨어로 채용하여 구축하였다. 전류전송제어시스템은 초전도자석시스템에 전류를 전송하기 위한 시스템으로서 전류전송과 동시에 초전도자석이 초전도상태를 유지하기 위한 냉매의 전송도 담당하고 있다. 주제어실에서의 원격운전을 위하여 EPICS IOC(Input Output Controller) 서버를 현장에 설치하였고 이를 통하여 전류전송제어시스템은 고유의 이름(PV)에 적절한 조작 및 감시 명령을 부여하여 주제어실의 운전화면을 통하여 시스템의 감시 및 조작이 가능하도록 하였다. EPICS와 PLC의 통신을 위하여 ether-ip 드라이버를 이용하여 EPICS IOC를 구축하였으며, 시험 결과 안정성 및 운용성 측면에서 만족할 만한 결과를 획득하였다.

차량 엔진룸 냉각용 후드 개발을 위한 수치해석 (Numerical analysis for development of vehicle engine room cooling hood)

  • 이석영
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.92-97
    • /
    • 2018
  • 본 연구는 자동차 엔진룸 내부에서 엔진과 연계된 부품의 냉각효과를 높이기 위해 후드 개발을 위한 수치해석을 다루고 있다. 급격한 온도편차에서 유발되는 엔진룸내 부품 온도를 저감시키면 부품에 대한 내구성 저하를 최소화 할 수 있다. 따라서, 본 연구에서는 차량 엔진룸 주요 부품 중에서도 온도제어가 비교적 용이한 발전기, 배터리, ECU 및 파워스틸 오일 등 4가지 부품을 목표로 엔진룸 냉각용 후드 개발을 위한 수치해석을 수행하였다. 그리고 수치해석을 검증하기 위하여 수치해석에서 가정하였던 동일한 조건으로 실험을 수행하여 비교하였다.

A Study on the Automatic Sensing Device for Gas Leakage of Cooling Plate Using the Microprocessor System

  • Wang, Jee-Seok;Yoon, Hee-Jong;Kang, Ki-Seong;Kim, Jong-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권3호
    • /
    • pp.329-334
    • /
    • 2011
  • The cooling water circulation plates had been used to drop the temperature of refractory outside shell of common cooling system by using cooling plate or stave type. When they are attacked by surrounding gas, they are corroded and the water flows in the refractory due to leakage of water. So, the life of refractory material is shortened and changed due to the worse conditions of cooling system. The automatic sensing device for water leakage of cooling plate is developed to check the position of trouble by using the microprocessor system when cooling water leak and gas are flowed into the cooling plate through the leakage position. The flowed gas is detected in the micro-process system which delivers the detected position of cooling plate or stave to main control room through the wireless-radio relay station. This system can be possible to detect the position of cooling plate or stave against the water leakage part immediately and then deliver the signal to main control room by using the microprocessor system and wireless-radio relay station. This system will be developed in changing the working condition from manual system to unmanned auto alarm system.

실험적 방법을 이용한 고압증기 시스템의 방음설계 및 검증에 관한 연구 (A Study on Noise Control and Verification of High Pressure Steam System Using Experimental Method)

  • 석호일;이도경;정태석;허주호
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.112-116
    • /
    • 2011
  • The noise analysis is usually carried out in the early structure design stage for the main areas in a vessel such as an accommodation, an engine room, HVAC System and etc. If the analysis results are higher than the noise limits based on guideline, appropriate countermeasures are established to reduce noise levels and applied to the vessel. But excessive noise induced the main or auxiliary equipment and high pressure steam system is very difficult to check in the initial design stage, and local noise problems frequently appear in actual vessels. This paper deals with excessive noise of the engine control room on LNG carrier. It includes the cause analysis of excessive noise, the countermeasure, and verification. Also, it proves suitability of the countermeasure through the on-board test.

  • PDF

화재 후 운전원수동조치(OMA) 정량화를 위한 화재 인간신뢰도분석 (HRA) 요소에 대한 고찰 (An Investigation of Fire Human Reliability Analysis (HRA) Factors for Quantification of Post-fire Operator Manual Actions (OMA))

  • 최선영;강대일;정용훈
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.72-78
    • /
    • 2023
  • The purpose of this paper is to derive a quantified approach for Operator Manual Actions (OMAs) based on the existing fire Human Reliability Analysis (HRA) methodology developed by the Korea Atomic Energy Research Institute (KAERI). The existing fire HRA method was reviewed, and supplementary considerations for OMA quantification were established through a comparative analysis with NUREG-1852 criteria and the review of the existing literature. The OMA quantification approach involves a timeline that considers the occurrence of Multiple Spurious Operations (MSOs) during a Main Control Room Abandonment (MCRA) determination and movement towards the Remote Shutdown Panel (RSP) in the event of a Main Control Room (MCR) fire. The derived failure probability of an OMA from the approach proposed in this paper is expected to enhance the understanding of its reliability. Therefore, it allows moving beyond the deterministic classification of "reliable" or "unreliable" in NUREG-1852. Also, in the event of a nuclear power plant fire where multiple OMAs are required within a critical time range, it is anticipated that the OMA failure probability could serve as a criterion for prioritizing OMAs and determining their order of importance.

냉각재(冷却材) 상실사고시(喪失事故時) 1300 MWe 급(級) PWR원전(原電) 주제어실(主制御室)의 선량평가(線量評價) (A Control Room Dose Assessment for a 1300 MWe PWR Following a Loss of Coolant Accident)

  • 장시영;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.34-45
    • /
    • 1989
  • 프랑스의 1300 MWe 급(級) 표준(標準) P'4형 PWR 원전(原電)의 일차냉각재상실사고(一次冷却材喪失事故)(LOCA)시(時) 원전(原電) 주제어가내(主制御家內) 운전원(運轉員)에 대한 고사선(故射線) 피습선량(被濕線量)을 계산하여 주제어실(主制御室)의 체류안전성(滯留安全性)을 평가(評價)하였다. 본(本) 평가(評價)에서 사용(使用)된 제가정(諸假定)은 프랑스의 표준안전성분석보고서(漂準安全性分析報告書)에 따랐다. 본(本) 평가(評價)를 위하여 LOCA 사고시(事故時) 원자로건물외(原子爐建物外)로 방출(放出)되는 방사핵종(放射核種)의 방사능(放射能), 주제어실(主制御室)에서의 체적인자(體積因子) 및 제어실내(制御室內) 운전원(運轉員)의 전신(全身) 및 갑상선(甲狀膳) 피폭선량(被爆線量)을 사고발생후(事故發生後) 30일까지 전산(電算)할 수 있는 간단한 전산(電算)프로그램, COREX를 개발(開發)하였다. 본(本) 연구(硏究)에서 얻어진 계산결과(計算結果)는 대체적으로 프랑스의 EDF(불란서 전력주식회사(電力株式會社) 에서 제안(提案)한 결과(結果)와 대체적으로 잘 일치(一致)하였으나, 전신외부피폭선량(全身外部被爆線量)의 값은 일부(一部) 체적인자(體積因子) 값의 차이로 인(因)하여 일부 편차(偏差)를 보였다.

  • PDF

데이터센터의 합리적인 환경제어를 위한 공기분배 시스템에 대한 연구 (A Study on Air-distribution method for the Thermal Environmental Control in the Data Center)

  • 조진균;차지형;홍민호;연창근
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.487-492
    • /
    • 2008
  • The cooling of data centers has emerged as a significant challenge as the density of IT server increases. Server installations, along with the shrinking physical size of servers and storage systems, has resulted in high power density and high heat density. The introduction of high density enclosures into a data center creates the potential for "hot spots" within the room that the cooling system may not be able to address, since traditional designs assume relatively uniform cooling patterns within a data center. The cooling system for data center consists of a CRAC or CRAH unit and the associated air distribution system. It is the configuration of the distribution system that primarily distinguishes the different types of data center cooling systems, this is the main subject of this paper.

  • PDF