• Title/Summary/Keyword: main control room

Search Result 211, Processing Time 0.024 seconds

Development of a Systematic Checklist for the Ergonomic Evaluation of the Critical Function Mornitoring System in the Main Control Room of a Nuclear Power Plant (원자력발전소 주제어실내 Critical function mornitoring system의 인간공학적 평가를 위한 체계적 checklist의 개발)

  • 홍상우;한성호;윤명환;곽지영;이용희
    • Proceedings of the ESK Conference
    • /
    • 1997.04a
    • /
    • pp.72-74
    • /
    • 1997
  • Integration and standardization of the related regulations and guidelines are necessary to evaluate a CFMS in a systematic manner. In this study, a hierachically categorized evaluation checklist was developed by collecting and structuring human factors issues listed in the various regulations, design requirements, and technical report. A PC-based database management system was developed to update and review the evaluation results. Standard interpretation examples, evaluation guidelines, and sample evaluation formats were also designed and integrated into the database system to reduce discrepancy in evaluation.

  • PDF

A Measurement of Electromagnetic Emission at Main Control Room in Nuclear Power Plant (원자력발전소 주제어실 전자기 방사성잡음 측정)

  • Goo, Cheol-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1950-1952
    • /
    • 2002
  • 원자력 발전소 방사성 잡음 규제기준을 설정하기 위하여 발전소 내의 전자파 잡음 환경을 측정하였다. 대상 발전소는 1000 MW급 울진 원자력발전소 3호기로 발전소 출력 0 %에서부터 100 %까지 10일간 주 제어실 및 전기설비실 주변을 대상으로 US NRC Reg. Guide 1.180 및 Mil-Std-462D를 측정기준으로 하여 전기장 10 kHz ${\sim}$ 7 GHz. 자기장 30 Hz ${\sim}$ 100 kHz의 방사성 잡음을 측정하였다. 측정결과를 최소자승법을 이용한 회귀분석으로 잡음 한계값을 유도하여 미국 EPRI 및 NRC 측정결과와 비교한 결과 자기장의 경우 낮은 한계값을 보였고 전기장의 경우는 20 dB 이상 높게 결정되었다.

  • PDF

Human-Sensitive Mot ion Interpretation of Emotional Robot "Rai" (감성 로봇 "라이"의 감성적 동작 구현)

  • 김연훈;이동연;김병수;곽윤근
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.327-332
    • /
    • 2002
  • We made a human-sensitive motion interpretation to the interactive emotional robot, "Rai" of which the mechanism design was carried out and completed. Kinematic system of this emotional robot mainly consists of a body and a head. The body contains the total control units , the communicat ion modules and also two wheels and motors for main driving which make kinds of motions 1 ike the inverted pendulum. This robot system is designed under the concept on the human-friendly mot ion and react ion wi th humans around living room and office environments. Therefore, various scenarios are constructed in order to enable the emotional expressions at those places. Especially, we interpreted technically-possible motions while accommodating to the scenarios constructed. And we performed some experiments to make sere of the possibility of the motion interpretation.

  • PDF

Data Transporting between Dynamic Model and Display Model of Power Plant Simulator (발전소 시뮬레이터의 다이나믹 모델과 디스플레이 모델간 데이터전송)

  • 김동욱
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1998.03a
    • /
    • pp.86-90
    • /
    • 1998
  • The safety and reliability of nuclear power plant operations relies heavily on the plant operators ability to respond to various emergency situations. It has become standard industry practice to utilize simulators to improve the safety and reliability of nuclear power plants operations. The simulators built for Younggwang#3,4, which is the basic model of the Korean Nuclear Power Plant design, has been developed precisely for this purpose. Dynamic Model and Display Model are developed under US3(UNIX Simulation Software Support System) environment in simulator for Younggwang#3,4. Since these two models are developed under each own operating system, it is necessary to develop a method for transporting data between these two systems. This paper descirves communication environment between Dynamic Model and Display Model, and addresses a file generation method for the Display Model, which will be necessary for designing MMI of MCR(Main Control Room) in the furture.

  • PDF

Causes and Measures of Flood Damage ('99.8) in Imjin River Basin (임진강 유역 대홍수 ('99,8)의 피해 원인과 대책)

  • 김현영;이용직
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.454-458
    • /
    • 1999
  • This study is to analyze the causes of flood damage in Imjin river basin inAugust , 1999. and to propose the measure to reudce such flood damage. The northern part of Kyonggin Province in the basin was severely damaged by flood due to the heavy rainfall for 4 days from 31 July to 3 August, whioch was recordedas 1,032mm. The heavy rainfall worth recording was one of main cuasese of such damage, but unsuitable river improvement and basin management were also important causes. The flood proptection works such as flood control reservoir and riverlevee were not contructed or sufficient in spite of the unflavorable geographical conditions of Imjin reiver. In case of irrigatiion faciliteis, 43 pumping stations in 3 FIAs were severely damaged due to inundation of the pump and switch boxes. The protection works for pump room should be improved to reduce the damage due to inundation.

  • PDF

Development of HVAC System to Lower the Conveyance Energy and Building Height

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.13 no.1
    • /
    • pp.31-43
    • /
    • 2005
  • The new HVAC system is developed to lower the conveyance energy and building height using IAV(Increasing Air Volume) technique. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy. size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 percentage.

A Study on the Temperature Controlled Performance of Thermal Reflective Exterior Finishes (열반사성 외장마감재의 온도조절 성능에 관한 연구)

  • Ryu, Hwa-Sung;Shin, Sang-Heon;Song, Sung-Yong;Kim, Deuck-Mo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.186-187
    • /
    • 2019
  • In modern times, due to the centralized urban structure, the interval between buildings is narrow and the increase of the heat island phenomenon due to the accumulation of the structure is becoming a social problem. In order to solve these problems, various materials for reducing the surface temperature of buildings are under study. Particularly, in the case of a wall part which is a part directly affected by the outside air of the building, it is a main structural part for determining the room temperature. The purpose of this study was to develop a material that can improve the thermal environment performance of the building by evaluating the temperature control performance of the exterior finishing material using the heat reflecting material as a method for controlling the temperature of the outer wall finishing material.

  • PDF

The Development of Full-Scope Replica Type Simulator for PWR Nuclear Power Plants (가압경수로 원자력 발전소의 전범위 복제형 시뮬레이터 개발)

  • 이중근
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.1
    • /
    • pp.85-96
    • /
    • 1997
  • Designing and constructing a proper simulator for real power plants requires extensive research in human engineering and computer science and integration of different fields of technologies such as system analysis, operational knowledge for nuclear plant, etc. A full scope replica type simulator for nuclear power plant is developed. The simulator has the same feature and operational functions as one in the main control room (MCR) of a reference power plant. The simulator provides the necessary training to recover or reduce damages from accidents that usually are unpredictable. This paper describes the configurations and characteristics for the simulator that is developed for Younggwang Nuclear Power Plant #3,4 which is the basic model of the Korean Nuclear Power Plant. The paper also describes technical aspects of Auto Code Generator that is used for developing the simulator. The successful development of the simulator will contribute to improve safety in operation of nuclear power plants.

  • PDF

A study on the space production special quality that in mass reflex media (대중영상매체 속에 나타난 공간연출 특성에 관한 연구)

  • 지홍근;김봉재;신홍경
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2002.04a
    • /
    • pp.121-124
    • /
    • 2002
  • Mass culture is product of media technology. We are absorbing and surround in optical image which reflex medium emits by night and day continually specially and live culture and information produced infinitely through mass media. People discharging in main living room now to remote control a television manufacture because carrying out move freely and is preoccupied with object of interest that have been spread in a television, and assimilate all image like sponge. Reflex medium contacted habitually every day whether do not want even if want can do that populace cultural personality is much stronger as subject that make actuality of processing.

  • PDF

Seismic Performance Evaluation for MCR of Nuclear Power Plant Isolated by FPS (FPS로 면진된 원전 주제어실의 내진 성능 평가)

  • 김대곤;김우범;서용표;문대식;김종엽
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2003.09a
    • /
    • pp.453-460
    • /
    • 2003
  • The objective of this study is to investigate the seismic performance for a seismically isolated main control room (MCR) of nuclear power plant. MCR was isolated by spherically shaped friction pendulum system (FPS). The FPS provided the simplest means of achieving long period in the isolation system under low gravity load. Some parametric studies were conducted with different properties of FPS. When the coefficient of friction in the sliding surface of FPS is low, the seismic performance of MCR was satisfactory However, the lateral displacement in the isolation level was rather large. To restrict this displacement into adequate range, a fluid viscous dampers were used.

  • PDF