• Title/Summary/Keyword: magnification

Search Result 689, Processing Time 0.021 seconds

Micro Sampling System for Highly Radioactive Specimen by Laser Ablation (Laser Ablation에 의한 고방사성시편의 미세영역 시료채취 장치개발)

  • Han Sun Ho;Ha Yeong Keong;Han Ki Chul;Park Yang Soon;Jee Kwang Yong;Kim Won Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • Shielded laser ablation system composed of laser system, image analyser, XYZ translator with motion controller, ablation chamber, manipulator and various optics was designed. Nd:YAG laser which can be tunable from 1064 nm to 266 m was selected as light source. CCD camera(< $\pm$200) was chosen to analyze a crater less than 50 un in diameter. XYZ translator was composed of three linear stage which can travel 50 w with a minimum movement of 1 um and motion controller. Before the performance test, each part of system was optically aligned. To perform the ablation test, the specimen was ablated by 50 um interval and observed by image analyser The shape of crater was almost round, indicating laser beam has homogeneous energy distribution. The resolution and magnification of image system were compatible with the design.

  • PDF

AN EXPERIMENTAL STUDY ON THE FITNESS OF THE CERVICAL MARGIN IN THE CERAMO-METAL CROWN ACCORDING TO THE ALLOY TYPES AND THE CURVATURE OF LABIO-CERVICAL MARGIN (도재소부전장금관용 합금과 순측치경부 변연만곡도에 따른 변연적합도에 관한 연구)

  • Jeon Young-Chan;Kim Jung-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.181-196
    • /
    • 1991
  • The Purpose of this study was to evaluate the marginal fit of ceramo-metal crown according to the different ceramo-metal alloy types and the curvature of labio-cervical margin. Degudent $G^{(R)}$ as precious and $Verabond^{(R)}$ as non-precious ceramo-metal alloy were used. The abutment was preparaed with two different curvature types : a normal curvature type and a pronounced curvature type. 20 crowns were farbricated using four different combinations and their marginal fits were measured at 3 consecutive stages (before degassing, after degassing, after glazing) using microscope under 200 magnification. The results were as follows: 1 . Marginal fitness before degassing. The groups of precious ceramo-metal exhibited better marginal fit than the groups of non-precious ceramo-metal with significant difference(P<0.05) . In the same ceramo-metal groups, the normal curvature group exhibited better marginal fit than the pronounced curvature group but without significant difference(P>0.05). 2. Marginal fitness after degassing. By degassing, the group of pronounced curvature and non-precious ceramo-metal was deformed the most, and the degree of margin fitness of each group was the same as before degassing. 3. Marginal fitness after glazing The group of normal curvature and precious ceramo-metal exhibited better marginal fit than the group of pronounced curvature and non-precious ceramo-metal with significant difference(P>0.05), and the degree of margin fitness of each group was the same as before degassing.

  • PDF

MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE

  • Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.1
    • /
    • pp.120-132
    • /
    • 1998
  • This stusy was to investigate the marginal fitness of porcelain-fused-to- metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento- enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing. body porcelain firing, and glazing, and measuring sites were 4. (midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus. Japan) was used under ${\times}250$ magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.

  • PDF

Advanced Treatment Planning Method for Gamma Knife Radiosurgery of Cerebral Arteriovenous Malformations (뇌동정맥기형의 감마나이프 방사선 수술 -치료 계획 방법의 개선을 중심으로-)

  • Jang Geon-Ho;Lim Young Jin;Hong Seong Eon;Leem Won
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.87-94
    • /
    • 1995
  • Since March 1992, total 200 patients who visited our hospital as functional or organic lesions of central nervous system were treated by gamma knife stereotactic radiosurgery for 27 months. Thirty-nine patients of total cases was diagnosed as cerebral arteriovenous malformation. The rate of magnification on X-ray film was reduced by cutting fixation adaptor from 1.0 to below 1.45 times. In order to treat the deep- and lateral-seated cerebral arteriovenous malformation, we slightly modified the angiographic indicator, the commercial Leksell system, by cutting each inner sides about 5mm, We performed the more distinction of the scales by adapting 0.5mm or 1mm copper filter to angiographic indicator. The center point of indicator(X=100mm, Y=100mm, Z=100mm) is corrected by adjusting scales of X-, Y-, Z-axis to each inner 100 and outer 100 point within 1-2mm by repeated exposure of X-ray on films in trial-and-errors. We have developed the 'GKANGIO' programed as the Fortran-77 in Microvax - 3100, which can save treatment planning time and perform accurate pretreatment planning using the theoretical target metrix center. The theoretical description of the simplified method is presented for the reduction of experimental and numerical errors in treatment planning of radiosurgery.

  • PDF

Image Downscaling Method Optimized for Future Magnification (확대에 최적화 된 영상 축소 방법)

  • Shin, Hyun-Joon;Wee, Young-Cheul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.1
    • /
    • pp.39-44
    • /
    • 2011
  • In this paper, we introduce a novel method to reduce image to a small size, such that the quality of the image is improved when it is up-scaled. Recent hardwares including cameras and display devices allow us to capture and display high-resolution images. However, it is not always realistic to store and transmit those high-resolution images due to limitation of storage and network bandwidth. Therefore, high-resolution images are often down-scaled to be stored and transmitted, and then up-scaled back for display. To improve final image quality in this scenario, we first formulate selected up-scale methods as linear transformations. The optimal reduction methods are obtained as its inverse transformation. Based on this basic idea, we develop down-scale kernel that is optimized for each up-scale method. In our experiment, the proposed method could improve the quality of the up-scaled image noticeable.

Fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro

  • Foek, Dave Lie Sam;Yetkiner, Enver;Ozcan, Mutlu
    • The korean journal of orthodontics
    • /
    • v.43 no.4
    • /
    • pp.186-192
    • /
    • 2013
  • Objective: To analyze the fatigue resistance, debonding force, and failure type of fiber-reinforced composite, polyethylene ribbon-reinforced, and braided stainless steel wire lingual retainers in vitro. Methods: Roots of human mandibular central incisors were covered with silicone, mimicking the periodontal ligament, and embedded in polymethylmethacrylate. The specimens (N = 50), with two teeth each, were randomly divided into five groups (n = 10/group) according to the retainer materials: (1) Interlig (E-glass), (2) everStick Ortho (E-glass), (3) DentaPreg Splint (S2-glass), (4) Ribbond (polyethylene), and (5) Quad Cat wire (stainless steel). After the recommended adhesive procedures, the retainers were bonded to the teeth by using flowable composite resin (Tetric Flow). The teeth were subjected to 10,00,000 cyclic loads (8 Hz, 3 - 100 N, $45^{\circ}$ angle, under $37{\pm}3^{\circ}C$ water) at their incisoproximal contact, and debonding forces were measured with a universal testing machine (1 mm/min crosshead speed). Failure sites were examined under a stereomicroscope (${\times}40$ magnification). Data were analyzed by one-way analysis of variance. Results: All the specimens survived the cyclic loading. Their mean debonding forces were not significantly different (p > 0.05). The DentaPreg Splint group (80%) showed the highest incidence of complete adhesive debonding, followed by the Interlig group (60%). The everStick Ortho group (80%) presented predominantly partial adhesive debonding. The Quad Cat wire group (50%) presented overlying composite detachment. Conclusions: Cyclic loading did not cause debonding. The retainers presented similar debonding forces but different failure types. Braided stainless steel wire retainers presented the most repairable failure type.

THE EFFECT OF SPRUE DESIGN ON THE MARGINAL REPRODUCIBILITY OF CAST TITANIUM CROWNS (주입선 형태가 티타늄 주조관의 변연재현성에 미치는 영향)

  • Park Jae-Kyoung;Jeong Chang-Mo;Jeon Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.4
    • /
    • pp.352-364
    • /
    • 2002
  • There has been a great interest in the use of titanium for fixed and removable prostheses in recent because of its excellent biocompatibility. However the high melting temperature and chemical reactivity of titanium necessitates casting systems different from those used in conventional casting. The current titanium casting systems are based on an electric-arc design for melting the metal in an argon atmosphere and its exclusive investment. Despite the new developments in Ti casting systems, inadequate mold filling and internal porosity are frequently observed casting defects. Therefore, the study on the fabrication technique including sprue design to solve these casting defects is still necessary. In this study to evaluate the effect of sprue design on the castability of simulated cast titanium crowns, 10 cylindrical cast crowns for each group with four different sprue design(Single group. Double group, Runner bar group. Reservoir group) were fabricated. An impression of the entire casting margin was made and cut at $90^{\circ}$ intervals, and the sections were photographed in a microscope at $100{\times}$ magnification to record marginal discrepancy. The internal porosities of the cast crowns were disclosed by radiographs. Within the limits of this study. the following conclusions were drawn. 1. The overall mean marginal discrepancies for each group were as follows: Double group, $43.65{\mu}m$; Reservoir group, $50.27{\mu}m$; Single group, $54.17{\mu}m$; Runner bar group, $58.90{\mu}m$ (p<0.05). 2. The mean of marginal discrepancies for wax patterns was $10.65{\mu}m$. 3 The numbers of internal porosity showed the most in Runner bar group followed by Single group, Reservoir group, and Double group.

A Comparative Study on the Marginal Fit between Castable Ceramic(Dicor) Crowns and Metal-Ceramic Crowns (주조도재관과 도재전장주조관의 치경부 변연적합도에 관한 비교 연구)

  • Kim, Jeong-Ho;Yang, Jae-Ho;Lee, Sun-Hyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 1988
  • The recently introduced castable glass ceramics incorporate properties characteristic of natural teeth and they are regarded as an ideal material to restore lost tooth structure. The purpose of this study was to compare the marginal fit of castable ceramic crown with that of the metal-ceramic crown in the process of heat treatment. Two master dies for castable ceramic crowns and metal-ceramic crowns were fabricated from being cast with the base metal. Each master die was duplicated with addition silicone and hard stone. Ten castable ceramic crowns were made on each hard stone die and their marginal openings were measured three times first, after casting; second, after ceramming; third, after shading. The other ten metal-ceramic crowns were made on each hard stone die and their marginal openings were measured three times : first, after casting; second, after degassing; third, after porcelain veneering. Each crown was seated on its master die with the constant force delivered by loading jig. And then, marginal openings were measured on four locations by optical projector at X50 magnification. The results were as follows: 1. The mean marginal openings of castable ceramic crowns were $31.1{\pm}12.7{\mu}m$ after casting; $44.6{\pm}12.8{\mu}m$ after ceramming; $51.2{\pm}16.8{\mu}m$ after shading. 2. The mean marginal openings of the metal-ceramic crowns were $26.2{\pm}13.8{\mu}m$ after casting; $29.8{\pm}10.3{\mu}m$ after degassing; $38.0{\pm}14.5{\mu}m$ after porcelain veneering. 3. There was significant increase in the marginal opening of castable ceramic crowns after ceramming, while metal-ceramic crowns sho(wed significant increase after porcelain veneering (p<0.05). 4. Marginal fit of metal-ceramic crown was better than that of castable ceramic crown (p<0.01).

  • PDF

A Simple Method to Determination the Rotation Angle Between an Image and its Diffraction Pattern with LACBED Patterns (LACBED 패턴으로부터 전자현미경 상에 대한 회절도형의 회전각을 측정하는 간단한 방법)

  • Kim, Hwang-Su;Kim, Jong-Pil
    • Applied Microscopy
    • /
    • v.33 no.3
    • /
    • pp.187-193
    • /
    • 2003
  • When electron microscope images and selected area diffraction patterns of crystalline materials are being compared, it is important to know for the rotation of the diffraction pattern with respect to the image caused by the magnetic lens in the Electron Microscope. A well-known method to determine this rotation is to use a test crystal of $MoO_3$. But this method of determination of the rotation angle contains an uncertainty of $180^{\circ}$. Thus one has to devise another way to eliminate this uncertainty. In this paper we present a new and simple method of determining this rotation without any complexity. The method involves a process of obtaining LACBED patterns of crystalline materials. For the J2010 electron microscope, the rotation is determined to be $180^{\circ}$ and this angle remains unchanged for changing of the magnification and the camera length.

Investigation of Micromorphological Characteristics of Acupuncture Needle Tip Sold in Europe (유럽에서 유통되는 일회용침 끝의 미세 형태에 대한 관찰)

  • Jang, In-Soo;Lee, Tae-Ho;Lee, Chang-Hyun;Park, Jong-Bae
    • Korean Journal of Acupuncture
    • /
    • v.21 no.4
    • /
    • pp.43-51
    • /
    • 2004
  • Objectives : In order to ensure safe acupuncture treatment, the quality of the needle tip is essential. But, there have not been so many studies about the quality of the acupuncture needle tip. For this reason we have been already reported about the quality of acupuncture needle tip in Korea using scanning electron microscope(SEM) in 2002, 2003. In order to compare than other society, we investigated the current condition of the tips of the acupuncture needles sold in Europe. Methods : We obtained the needles made by 7 companies, which are sold currently in Europe, and selected 50 pieces out of 100 pieces from each company by randomized methods. And then we observed the tip of each needle using a scanning electron microscope at ${\times}800$ magnification. Results and Discussion : We found that needles had several defects such as scratch marks on the surface, metallic scuff, lumps and irregularities of the needle tips, stubbed or malformed tips, tips of point off-center, peeled off coated tips, same as Korean needles. There was much difference on the quality of needles among the manufacturers, and some needles seem to need thorough quality control. Allowing for the high price, the quality of some needle in Europe generally are better than that of Korean needles. But some Korean needles hold a top position than European ones in quality. We want a good industrial standard to be made in acupuncture manufacturing fields in the near future, because the safety is not less valuable than the efficacy in medicine.

  • PDF