• Title/Summary/Keyword: magnetic signal

Search Result 1,364, Processing Time 0.027 seconds

Interictal rCBF SPECT, MRI and Surgical Outcome of Intractable Temporal Lobe Epilepsy (난치성 측두엽간질의 발작간 뇌혈류 SPECT, MRI와 수술성과 비교)

  • Zeon, Seok-Kil;Joo, Yang-Goo;Lee, Sang-Doe;Son, Eun-Ik;Lee, Young-Hwan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.307-312
    • /
    • 1994
  • Interictal single photon emission computed tomography of regional cerebral blood flow (rCBF SPECT) in 18 intractable temporal lobe epilepsy patients(8 male and 10 female patients: average 23.5 years old) were compared with 2.0 T magnetic resonance imaging (MRI). And surgical outcome was analysed with the findings, symptom duration and lateralization of temporal lobe. Preoperatively rCBF SPECT was done in all 18 patients with intravenous injection of 740 MBq 99mTc-HMPAO. MRI was also done preoperatively in 13 patients. Surgical outcome was classified by Engel's outcome classification(four-part classification recommended at the first Palm Desert conference). rCBF SPECT detected correctly lateralising abnormality of temporal lobe hypoperfusion in 13/18(72.2%), contralateral temporal lobe hypoperfusion in 2/18(11.1%) and showed no def-inite abnormality in 3/18(16.7%). The positive predictive value of unilateral temporal lobe hypoperfusion was 87%. MRI detected correct localising abnormality in 8/13(61.5%), such as hippocampal atrophy(7/13), asymmetric temporal horn(6/13), anterior temporal lobe atrophy(1/13), increased signal intensity from hippocampus(1/13) and calcific density(1/13), and no abnormal finding was noted in 5/13(38.5%). There was no false positive findings and the positive predictive value of MRI was 100%. Only 2 cases showed same lateralization findings in rCBF SPECT and MRI. There was no significant correlation between symptom duration and no abnormal findings on SPECT or MRI. Surgical outcome showed class I in 15/18(83.3%), and class II in 2/18(11.1%). One case of no abnormal finding in both SPECT and MRI showed class III surgical outcome. No class IV surgical outcome was noted. Surgical outcome, lateralization of epileptic focus in temporal lobe and abnormal findings in rCBR SPECT or MRI were not significantly correlated.

  • PDF

Neural responses to sonic branding : an fMRI study (소닉 브랜딩에 대한 신경 반응 : fMRI 연구)

  • Sung, Young-Shin;Choi, Min-Jo;Chung, Sun-Joo;Kim, Chai-Youn
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.93-100
    • /
    • 2011
  • Sonic branding is defined as creation and management of brand value by using sounds. Among various methods of sonic branding, sonic logo, i.e., brand’s acoustic identification element, is the most widely used form and usually combined with visual logo. Although sonic branding has become an increasingly important tool for marketers, little academic research has been done on this topic. The current study investigates neural responses to sonic branding using functional Magnetic Resonance Imaging (fMRI). Brain activity of 15 right-handed participants was monitored with 3T MRI machine, while they viewed sequentially presented pictures of brand logos (20 visual logos usually accompanied by sonic logos and 20 visual logos unaccompanied by sonic logos) without sound. Results showed that brain areas known to be associated with auditory imagery (including superior temporal gyrus, STG), showed greater activation for the visual logos usually accompanied by sonic logos compared to visual logos unaccompanied by sonic logos, although actual sound was not presented during scanning. The degree of familiarity participants have with the brand and its advertisements was correlated positively with signal strength in these areas.

  • PDF

Isolation and Purification of Berberine in Cortex Phellodendri by Centrifugal Partition Chromatography (Centrifugal Partition Chromatography에 의한 황백으로부터 Berberine의 분리 및 정제)

  • Kim, Jung-Bae;Bang, Byung-Ho
    • The Korean Journal of Food And Nutrition
    • /
    • v.27 no.3
    • /
    • pp.532-537
    • /
    • 2014
  • Cortex Phellodendri (CP) is derived from the dried bark of Phellodendron amurense. It has been widely used as a drug in traditional Korea medicine for treating diarrhea, jaundice, swelling pains in the knees and feet, urinary tract infections, and infections of the body surface. Many analytical methods have been used to study oriental herbal medicines, such as thin-layer chromatography, column liquid chromatography, and high performance liquid chromatography (HPLC). In this study, preparative centrifugal partition chromatography (CPC) was successfully carried out in order to separate pure compounds from a CP methanol extract. The optimum two-phase CPC solvent system was composed of n-butanol: acetic acid: water (4:1:5 v/v/v). The flow rate of the mobile phase was 3 mL/min in ascending mode with rotation at 1,000 rpm. The CPC-separated fraction and purification procedures were carried out by preparatory HPLC. The $^1H$ NMR spectrum revealed that the resonances at ${\delta}$ 4.10 and 4.20 ppm corresponded to three protons ($-OCH_3$), whereas those at ${\delta}$ 6.10 ppm corresponded to two protons ($-OCH_2O-$). Further, two aromatic protons (H-11 and H-12) conveys a doublet-doublet pattern. The H-11 doublet and H-12 doublet appear at ${\delta}$ 7.98 and 8.11, respectively. The $^{13}C$ NMR. spectrum showed a tetrasubstituted with a methylenedioxy group at C2 and C3, and two methoxy groups at C9 and C10. The chemical structure of the berberine was identified by $^1H$, $^{13}C$-nuclear magnetic resonance and electrospray ionization-mass spectroscopy spectral data analysis.

A study on the crustal structure of the continental margin in the East Sea along the Korea Peninsula using potential data (포텐셜자료를 이용한 한반도 동해 대륙주변부의 지각구조에 관한 연구)

  • Kim, Chang-Hwan;Yoo, Lee-Sun;Park, Chan-Hong;Suk, Dong-Woo
    • Journal of the Korean Geophysical Society
    • /
    • v.10 no.1
    • /
    • pp.13-25
    • /
    • 2007
  • We investigated the undulation of Moho depth and the crustal structure of the continental margin in the East Sea along the Korea Peninsula from inversion and modelling using potential data and previous seismic results. Free-air gravity anomalies generally reflect topography effect. Bouguer gravity anomalies increase toward the Ulleung Basin, indicating that Moho depth is shallower under the Ulleung Basin. Positive magnetic anomalies exist along the continental margin and decrease toward the Ulleung Basin. In analytic signal, the small anomaly in the Hupo Bank infers that the Hupo Bank is uplifted by igneous intrusion and the strong anomaly on the continental slope denotes existence of SDR(seaward dipping reflectors), which are in accordance with the location of SDR detected in previous seismic studies. The inversion result of Bouguer gravity anomaly and the 2-dimensional gravity modelling indicate that the undulation of Moho depth shallows from the continental shelf toward the Ulleung Basin. This is in good agreement with the Moho depth calculated by the previous seismic velocity model using ocean bottom seismometer(OBS). The 2-dimensional gravity modelling infers magmatic underplating zone under the lower continental crust on the continental margin of the East Sea, indicating the possible rifiting of the continental margin.

  • PDF

A Study on Coupling Coefficient Between Rail and Reinforcing Bars in Concrete Slab Track (콘크리트 슬래브궤도에서 레일과 철근 사이의 결합계수에 대한 연구)

  • Kim, Min-Seok;Lee, Sang-Hyeok;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.3
    • /
    • pp.405-411
    • /
    • 2009
  • Railway signaling system in a rapid transit using the ATC system the approved a speed limit to a train and a part of signaling system in a metro approved a distance which is possible to move. Referring to the way of transmitting train control information, there are the one transmitting it to the on-board system of a train using the direct track, the another transmitting it establishing an instrument, and the other transmitting an instrument by a railway track. The one is the method using the direct track as a conductor for composing the part of the track and attaining the information controlling a train by transmitting a signal to the track. It is used for the high-speed railway and the subway. The method using the track attains information by transmitting it to returned information, and the on-board system of a train attains it by magnetic coupling. Because many reinforcing bars on the concrete slab track are used, interaction between a rail and a reinforcing bar that is not produced on ballast track is made. Due to the interaction, the electric characteristic of rail is changed. In the current paper, we numerically computed the coupling coefficient between the rail and the reinforcing bar based on the concrete slab track throughout the model related to the rail and the reinforcing bar using the concrete slab track that is used in the second interval of the Gyeongbu high-speed railway, and we defined the coupling coefficient not changed in the electric characteristic of rail in the condition that there is no interaction between the rail and the reinforcing bar.

The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy (단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발)

  • Paik, Moon-Young;Lee, Hyun-Yong;Shin, Oun-Jae;Eun, Choong-Ki;Mu, Chi-Woong
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.39 no.5
    • /
    • pp.544-555
    • /
    • 2002
  • The aim of this study is to develop the $^1H$-MRS data postprocessing software for both single-voxel and multi-voxel technique, which plays and important role as a diagnostic tool in clinical field. This software is based on graphical user interface(GUI) under windows operating system of personal computer(PC). In case of single-voxel MRS, both of raw data in time-domain and spectrum data in frequency-domain are simultaneously displayed in a screen. Several functions such as DC correction, zero filling, line broadening, Lorentz-Gauss filtering and phase correction, etc. are included to increase the quality of spectrum data. In case of multi-voxel analysis, spectroscopic image reconstructed by 3-D FFT was displayed as a spectral grid and overlapped over previously obtained T1- or T2-weighted image for the spectra to be spatially registered with the image. The analysis of MRS peaks were performed by obtaining the ratio of peak area. In single-voxel method, statistically processed peak-area ratios of MRS data obtained from normal human brain are presented. Using multi-voxel method, MR spectroscopic image and metabolite image acquired from brain tumor are demonstrated.

Quadratic Sigmoid Neural Equalizer (이차 시그모이드 신경망 등화기)

  • Choi, Soo-Yong;Ong, Sung-Hwan;You, Cheol-Woo;Hong, Dae-Sik
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.36S no.1
    • /
    • pp.123-132
    • /
    • 1999
  • In this paper, a quadratic sigmoid neural equalizer(QSNE) is proposed to improve the performance of conventional neural equalizer in terms of bit error probability by using a quadratic sigmoid function as the activation function of neural networks. Conventional neural equalizers which have been used to compensate for nonlinear distortions adopt the sigmoid function. In the case of sigmoid neural equalizer, each neuron has one linear decision boundary. So many neurons are required when the neural equalizer has to separate complicated structure. But in case of the proposed QSNF and quadratic sigmoid neural decision feedback equalizer(QSNDFE), each neuron separates decision region with two parallel lines. Therefore, QSNE and QSNDFE have better performance and simpler structure than the conventional neural equalizers in terms of bit error probability. When the proposed QSNDFE is applied to communication systems and digital magnetic recording systems, it is an improvement of approximately 1.5dB~8.3dB in signal to moise ratio(SNR) over the conventional decision feedback equalizer(DEF) and neural decision feedback equalizer(NDFE). As intersymbol interference(ISI) and nonlinear distortions become severer, QSNDFE shows astounding SNR shows astounding SNR performance gain over the conventional equalizers in the same bit error probability.

  • PDF

Development of the EM wave Absorber for Improving the Performance of Hi-Pass System in ITS (ITS에 있어서 Hi-Pass 시스템의 성능 개선을 위한 전파흡수체의 개발)

  • Kim, Dong Il;Kim, Jeong Chang;Joo, Yang Ick
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1505-1510
    • /
    • 2014
  • High-Pass (ETC ; Electronic Toll Collection) system is one of the basic elements, which adopts a wireless communication method using 5.8 GHz and can realize a part of ITS (Intelligent Traffic System). On the other hand, communication errors occur frequently in Hi-Pass system due to signal erros, multi-path reflection, and/or system-to-system interferences. To solve these problems, an EM (Electro-Magnetic) wave absorber can be used. To solve these Problems, we fabricated some samples in the different composition ratios of Carbon, Sendust, and CPE, and it was confirmed that the optimum composition ratio of Carbon : Sendust : CPE is 10 : 40 : 50 wt.%. The complex relative permittivity and complex relative permeability were derived by using the measured data. In addition, the optimum design parameters for the absorber were determined by simulation. Then the absorption abilities were calculated by changing the thickness of the EM wave absorbers. As a result, the optimum thickness of the developed EM wave absorber was 2.85 mm with absorption ability over 22.4 dB at 5.8 GHz. Futhermore, the EM wave absorber was fabricated based on the simulated and designed values. The measured values agreed well with the simulated ones. Therefore, it was clearly shown that the developed EM wave absorber in this paper is to be applied in actual situations.

Design and Performance Evaluation of SSD (Simultaneous Single Band Duplex) System with HPA Nonlinearity (HPA 비선형 특성을 고려한 SSD(Simultaneous Single Band Duplex) 시스템의 설계와 성능 분석)

  • Keum, Hong-Sik;An, Changyoung;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • In this paper, we design a SSD(simultaneous single band duplex) system using RF cancellation and digital cancellation. And then, we analyze performance of the SSD system using pre-distorter with HPA non-linearity. Also, we analyze digital cancellation performance of the SSD system using pre-distorter with HPA non-linearity. Additionally, digital cancellation cancels residual self-interference. In linear conditions, digital cancellation can cancel self-interference of 40dB. Therefore, the SSD system has good BER performance because most of self-interference is canceled. But, in HPA non-linearity conditions, digital cancellation cancels residual self-interference of 25dB. In this conditions, self-interference is greater than desired signal. Therefore, bit informations of distant station can not be received. But, we confirm that if the proposed system uses pre-distorter then bit information of distant station can be received by HPA non-linearity compensation. Also, we confirm that even though the proposed system uses pre-distorter, if HPA non-linearity increases then digital cancellation performance is degraded by imperfect compensation of HPA non-linerity.

Medical Image Compression Using JPEG International Standard (JPEG 표준안을 이용한 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yoen
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.504-506
    • /
    • 1993
  • The Joint Photographic Experts Group (JPEG) standard was proposed by the International Standardization Organization (ISO/SC 29/WG 10) and the CCITT SG VIII as an international standard for digital continuous-tone still image compression. The JPEG standard has been widely accepted in electronic imaging, computer graphics, and multi-media applications, however, due to the lossy character of the JPEG compression its application in the field of medical imaging has been limited. In this paper, the JPEG standard was applied to a series of head sections of magnetic resonance (MR) images (256 gray levels, $256{\times}256$ size) and its performance was investigated. For this purpose, DCT-based sequential mode of the JPEG standard was implemented using the CL550 compression chip and progressive and lossless coding was implemented by software without additional hardware. From the experiment, it appears that the compression ratio of about 10 to 20 was obtained for the MR images without noticeable distortion. It is also noted that the error signal between the reconstructed image by the JPEG and the original image was nearly random noise without causing any special-pattern-related artifact. Although the coding efficiency of the progressive and hierarchical coding is identical to that of the sequential coding in compression ratio and SNR, it has useful features In fast search of patient Image from huge image data base and in remote diagnosis through slow public communication channel.

  • PDF