Study on Rod Position Indication System using Permanent Magnets with Shielding Plates for a Control Rod Drive Mechanism

  • Lee, Jae Seon;Cho, Sang Soon;Kim, Jong Wook
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.439-443
    • /
    • 2015
  • A control rod drive mechanism (CRDM) is an electromechanical equipment that provides linear movement for the control rods to control the nuclear reactivity in a nuclear reactor. A rod position indication system (RPIS) detects the control rod's position. To enhance the measurement accuracy of the system, a magnetostrictive type sensor with capability of generating operation limiting signals would be adapted instead of a conventional RPIS for a CRDM. An RPIS was modelled for a numerical analysis with the permanent magnets at the stationary limit positions and magnetic shielding plates with a moving permanent magnet. The performance analysis of the RPIS were conducted, and the results were discussed here.

Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

  • Hwang, S.M.;Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, K.;Lee, S.J.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권2호
    • /
    • pp.20-23
    • /
    • 2013
  • For sensitive measurements of micro-Tesla nuclear magnetic resonance (${\mu}T$-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 $fT/{\surd}Hz$, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise ${\mu}T$-NMR experiments.

고고도 전자기파(HEMP)차폐를 위한 전자파 차폐 콘크리트 벽체 개발에 관한 실험적 연구 (An Experimental Study on the Development of Electromagnetic Shielding Concrete Wall for Shielding High-altitude Electromagnetic Pulse (HEMP))

  • 최현준;김형철;임상우;이한승
    • 콘크리트학회논문집
    • /
    • 제29권2호
    • /
    • pp.169-177
    • /
    • 2017
  • 북한은 최근 핵무기의 일반적인 열, 폭풍, 방사능 피해가 아닌 전자 장비를 무력화시키기 위한 고고도 전자기파 탄을 개발 중인 것으로 예측되고 있다. 현재 군용 목적으로 사용되고 있는 HEMP 차폐 시설 중 차폐 판의 경우 전자파 차폐 효과가 뛰어난 금속 판이 사용되고 있으나 이러한 금속판들은 차폐 시설 제작 시 용접 부위에서의 전자파 유입 가능성 등 시공상의 어려움과 높은 비용이 문제시 되고 있는 실정이다. 이에 본 연구에서 차폐 시설을 따로 구축하지 않고 콘크리트 구조물 자체로써 전자파 차폐 효과를 확보하기 위하여 콘크리트 실험체에 전기전도성이 높은 재료를 혼입하였다. 또한, 실험체 중 가장 높은 차폐효과를 보인 2가지 수준과, 가장 낮은 차폐 효과를 보인 2가지 수준에 $100{\mu}m$ 아연-알루미늄 합금 금속용사 피막을 적용하였다. 실험 결과 전기전도성이 높은 재료를 혼입한 실험체는 MIL-STD-118-125-1 규격 최소 차폐 기준을 만족하지 못하였으나, 금속용사 피막을 적용한 실험체에서는 모두 최소 차폐 기준을 만족하였다. 결론적으로, $100{\mu}m$ 아연-알루미늄 합금 금속용사 피막이 HEMP 차폐에 높은 효율성을 가지고 있다고 판단된다.