• Title/Summary/Keyword: magnetic separation.

Search Result 408, Processing Time 0.028 seconds

Analysis of metabolomic patterns in thoroughbreds before and after exercise

  • Jang, Hyun-Jun;Kim, Duk-Moon;Kim, Kyu-Bong;Park, Jeong-Woong;Choi, Jae-Young;Oh, Jin Hyeog;Song, Ki-Duk;Kim, Suhkmann;Cho, Byung-Wook
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.11
    • /
    • pp.1633-1642
    • /
    • 2017
  • Objective: Evaluation of exercise effects in racehorses is important in horseracing industry and animal health care. In this study, we compared metabolic patterns between before and after exercise to screen metabolic biomarkers for exercise effects in thoroughbreds. Methods: The concentration of metabolites in muscle, plasma, and urine was measured by $^1H$ nuclear magnetic resonance (NMR) spectroscopy analysis and the relative metabolite levels in the three samples were compared between before and after exercise. Subsequently, multivariate data analysis based on the metabolic profiles was performed using orthogonal partial least square discriminant analysis (OPLS-DA) and variable important plots and t-test was used for basic statistical analysis. Results: From $^1H$ NMR spectroscopy analysis, 35, 25, and 34 metabolites were detected in the muscle, plasma, and urine. Aspartate, betaine, choline, cysteine, ethanol, and threonine were increased over 2-fold in the muscle; propionate and trimethylamine were increased over 2-fold in the plasma; and alanine, glycerol, inosine, lactate, and pyruvate were increased over 2-fold whereas acetoacetate, arginine, citrulline, creatine, glutamine, glutarate, hippurate, lysine, methionine, phenylacetylglycine, taurine, trigonelline, trimethylamine, and trimethylamine N-oxide were decreased below 0.5-fold in the urine. The OPLS-DA showed clear separation of the metabolic patterns before and after exercise in the muscle, plasma, and urine. Statistical analysis showed that after exercise, acetoacetate, arginine, glutamine, hippurate, phenylacetylglycine trimethylamine, trimethylamine N-oxide, and trigonelline were significantly decreased and alanine, glycerol, inosine, lactate, and pyruvate were significantly increased in the urine (p<0.05). Conclusion: In conclusion, we analyzed integrated metabolic patterns in the muscle, plasma, and urine before and after exercise in racehorses. We found changed patterns of metabolites in the muscle, plasma, and urine of racehorses before and after exercise.

Correlation between Changes in Microbial/Physicochemical Properties and Persistence of Human Norovirus during Cabbage Kimchi Fermentation

  • Lee, Hee-Min;Lee, Ji-Hyun;Kim, Sung Hyun;Yoon, So-Ra;Lee, Jae Yong;Ha, Ji-Hyoung
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.11
    • /
    • pp.2019-2027
    • /
    • 2017
  • Recently, cabbage kimchi has occasionally been associated with the foodborne diseases of enteric viruses such as human norovirus (HuNoV). This study aimed to evaluate the correlation between microbial/physicochemical properties and persistence of HuNoV in experimentally contaminated cabbage kimchi fermented and stored at $4^{\circ}C$ or $10^{\circ}C$ for 28 days. Changes in organic acid content, lactic acid bacteria (LAB), acidity, pH, and salinity were analyzed. The recovery of structurally intact HuNoV was examined for up to 28 days post-inoculation, using a NoV GII.4 monoclonal antibody-conjugated immuno-magnetic separation method combined with quantitative real-time reverse transcription polymerase chain reaction. On day 0, LAB loads were $4.70log_{10}$ colony forming units/g and HuNoV GII.4 titers were $2.57log_{10}\;genomic\;copies/{\mu}l$, at both temperatures. After 28 days, intact HuNoV titers decreased to 1.58 ($4^{\circ}C$) and $1.04(10^{\circ}C)log_{10}\;genomic\;copies/{\mu}l$, whereas the LAB density increased. This correlated with a gradual increase in lactic acid and acetic acid at both temperatures. Our findings support a statistical correlation between changes in physicochemical properties and the recovery of structurally intact HuNoV GII.4. Moreover, we determined that the production of organic acid and low pH could affect HuNoV GII.4 titers in cabbage kimchi during fermentation. However, HuNoV GII.4 was not completely eliminated by microbial/physicochemical factors during fermentation, although HuNoV GII.4 was reduced. Based on this, we speculate that the persistence of HuNoV GII.4 may be affected by the continually changing conditions during kimchi fermentation.

The study of Rolled Steel Process Wastewater by Superconducting High Gradient Magnetic Separation (초전도 마그네트를 이용한 고구배 자기분리 열연강판 폐수처리에 관한 연구)

  • Kim, Tea-Hyung;Ha, Dong-Woo;Oh, Sang-Soo;Kim, Ho-Sup;Ko, Rock-Kil;Kwon, Jun-Mo;Lee, Nam-Jin;Kim, Young-Hun;Kang, Chae-Hun;Ha, Tae-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.11-11
    • /
    • 2009
  • 종래의 산업폐수 처리기술로는 중금속 함유 폐수에 수용성의 금속염을 첨가하여 가성소다 혹은 소석회를 이용하여 pH를 조정하고 고분자 응집제를 첨가하여 금속의 수산화물을 생성시켜 이를 부상 혹은 침전시켜 Sludge화하여 제거하는 방법이 주로 사용되고 있다. 그 외 질소, 인, 유기물이 함유된 폐수의 경우에는 Biological Oxidation Techniques, 활성탄 흡착방식이 주로 채택되고 있다.[1-3] 이러한 폐수처리기술은 화학약품 사용량이 과다하고 이는 Sludge 생성량을 증대하고 2차 폐수처리가 필요로 하는 경우가 많고, 처리장이 면적이 넓어야 하고 대용량의 Sludge 제거창치가 필요하여 고비용의 처리공정으로 문제점을 가지고 있다.[2-3] 이에 본 연구에서는 이러한 기존 기술의 문제점을 보완할 수 있고 기존 기술로는 완벽하게 처리하기 곤란한 악성 폐수들에 대한 새로운 고도처리기술로 초전도 마그네트를 이용한 고구배 자기분리기술에 대한 기초연구를 하였다. 본 연구에서 사용한 고구배 자기분리 시스템은 무헬륨 전도냉각방식으로 자기분리를 위해 사용한 필터는 SUS 430 재질의 메쉬 형태로 제작하여 실험하였다. 또한, 자기분리 처리를 위한 전처리 공정으로는 응집제를 첨가하여 자기분리 효율을 높이고자 하였다. 자기분리 처리대상수로는 포항제철에 압연 강판에 사용되는 냉각수를 대상으로 자기분리 처리에 대한 효과를 실험하였다. 또한, 자기분리에 대한 특성을 평가하기 위해 강자성의 $Fe_3O_4$ 미세자성분말을 첨가하여 처리수내의 들어있는 유기물질에 대해 자기분리 자장 및 유속에 대한 처리효율을 미치는 영향을 조사하였다. 자기분리 처리는 1~6 Tesla에서 자기필터는 디스크 형태로 다층으로 연속적으로 적층하였으며, 처리유속은 1~4 l/min으로 하였다. 고농도인 처리폐수를 자가분리 인가 자장에 따라 처리하여 고농도에서는 70%, 저농도에서는 98 %까지 처리되었다. 또한, 자기분리용 필터는 SUS 430 재질의 mesh 망을 사용하였으며 인가자장 및 유속변화에 대한 실험 결과 탁도 및 농도는 필터 크기의 영향은 거의 차이가 없었으며 단지 인가자장 및 유속에 따라서 지수적으로 감소하였다. 자기분리된 용액 내 $Fe_3O_4$ 입도 분석 결과 자기분리 이전에 분포하던 $10\sim20\;{\mu}m$의 입자는 거의 제거되었으며 2 ${\mu}m$ 이하의 입자들은 실험 횟수에 따라 점점 직경이 작은 쪽으로 분포가 좁아졌으며, 마그네타이트의 자화율을 분석한 결과 약 0.8 Tesla에서 포화 되었으며 처리수의 탁도 및 농도가 자장에 따라 감소하는 것으 알 수 있었다.

  • PDF

Detection of Undeclared Betamethasone Derivatives in Cosmetic Products Labeled to Contain Zinc Pyrithione as the Active Ingredient (아연피리치온을 유효성분으로 표기한 화장품류에서 미표기 성분인 베타메타손 유도체의 검출)

  • Lee, Jeong-Pyo;Park, Sung-Hwan;Yang, Seong-Jun;Kim, Sun-Mi;Son, Kyung-Hun;Yun, Mi-Ok;Choi, Sang-Sook
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2009
  • Betamethasone propionate, an anti-inflammatory glucocorticosteroid, was detected in cosmetics with no indication on the label of this compound as an ingredient. The product was formulated as a topical spray or shampoo and labeled to contain zinc pyrithione as the active ingredient. A thin-layer chromatographic analysis was carried out on silica gel plates to provide a first indication about the presence of a compound with steroid structure and reactivity; then high-performance liquid chromatography (HPLC) separation allowed the identification of the corticosteroid agent and its quantification. To identify the corticosteroid agent from these commercial samples we collected the fractions suspected to have ketol steroids by prep HPLC and identified the compound as betamethasone propionate by NMR and MS spectrometry. Then we synthesized the standard for the betamethasone 17-propionate and 21-propionate and quantitate the corticosteroids from the sample by HPLC with that standards. By this method we identified the corticosteroid compounds from some commercial cosmetics such as zinc pyrithione sprays. The finding of betamethasone propionate in the products was shown by comparison to an authenticated standard of betamethasone propionate by retention time on reverse-phase HPLC. Two of the tested products contained betamethasone propionate at the levels of 0.005 ${\sim}$ 0.02% and the others were free of betamethasone propionate.

The Characteristic of Te Recovery in Gold Concentrate Using Electrolysis (전기분해법을 이용한 금정광내 Te 회수 특성)

  • Kim, Bong-Ju;Cho, Kang-Hee;Jo, Ji-Yu;Choi, Nag-Choul;Park, Cheon-Young
    • Economic and Environmental Geology
    • /
    • v.47 no.6
    • /
    • pp.645-655
    • /
    • 2014
  • In order to obtain pure metallic Te from gold concentrate, roasting treatment, hypochlorite leaching, Fe removal and electrolysis experiments were carried out. The contents of Au, Ag and Te from the concentrate sample and roasted sample were much more soluble in the hypochlorite solution than in aqua regia digestion, whereas the metals Pb, Zn, Fe and Cu were easier to leach with the aqua regia than the hypochlorite. With the addition of NaOH in the hypochlorite leaching solution prior to electrolysis, the Fe removal rate achieved was only 96% in the concentrate sample, while it reached 98% in the roasted sample. The results of electrolysis for 240 min, 98% of the metallic copper was recovered from the concentrate sample, while 99% was obtained from the roasted sample due to the removal of S by roasting. The amount of anode slime was also greater in the electrolytic solution with the roasted sample than with the concentrate sample. The results on the anode slime after the magnetic separation process showed the amount of metallic pure native tellurium recovered was greater in the roasted sample than in the concentrate sample.

Structural Analysis of Volatile Matters and Heavy Oil Fractions from Pyrolysis Fuel Oil by the Heat Treatment Temperature (열처리 온도에 따른 열분해 연료유 내 휘발유분 및 잔류 중질유분의 구조 분석)

  • An, Donghae;Kim, Kyung Hoon;Kim, Jong Gu;Lee, Young-Seak
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.297-302
    • /
    • 2019
  • In order to investigate structural changes of the pyrolysis fuel oil (PFO), the volatile matters and heavy oil fractions were separated from PFO by heat treatment temperature. As a result of $^1H-NMR$ analysis of volatile matters, 1~2 ring aromatic compounds contained in the petroleum residue were mostly removed at a temperature before $340^{\circ}C$. Moreover, new peaks corresponding to aliphatic hydrocarbons were detected at the chemical shift of 2.0~2.4 ppm. It is attributed that the aliphatic hydrocarbon sidechain was cracked from the aromatic compound by the cracking reaction occurred at $320^{\circ}C$. The C/H mole ratio and aromaticity increased with increasing the heat treatment temperature. Therefore, from the structural analysis results of heavy oil fractions and volatile matters from PFO, the decomposition of the aliphatic sidechain by cracking reaction and the separation of volatile matters by boiling point of components were mostly affected structure changes of the PFO.

A Novel Therapeutic Effect of a New Variant of CTLA4-Ig with Four Antennas That Are Terminally Capped with Sialic Acid in the CTLA4 Region

  • Piao, Yongwei;Yun, So Yoon;Kim, Hee Soo;Park, Bo Kyung;Ha, Hae Chan;Fu, Zhicheng;Jang, Ji Min;Back, Moon Jung;Shin, In Chul;Won, Jong Hoon;Kim, Dae Kyong
    • Biomolecules & Therapeutics
    • /
    • v.30 no.6
    • /
    • pp.529-539
    • /
    • 2022
  • Rheumatoid arthritis (RA) is a multifactorial immune-mediated disease, the pathogenesis of which involves different cell types. T-cell activation plays an important role in RA. Therefore, inhibiting T-cell activation is one of the current therapeutic strategies. Cytotoxic T-lymphocyte antigen 4-immunoglobulin (CTLA4-Ig), also known as abatacept, reduces cytokine secretion by inhibiting T-cell activation. To achieve a homeostatic therapeutic effect, CTLA4-Ig has to be administered repeatedly over several weeks, which limits its applicability in RA treatment. To overcome this limitation, we increased the number of sialic acid-capped antennas by genetically engineering the CTLA4 region to increase the therapeutic effect of CTLA4-Ig. N-acetylglucosaminyltransferase (GnT) and α2,6-sialyltransferase (α2,6-ST) were co-overexpressed in Chinese hamster ovary (CHO) cells to generate a highly sialylated CTLA4-Ig fusion protein, named ST6. The therapeutic and immunogenic effects of ST6 and CTLA4-Ig were compared. ST6 dose-dependently decreased paw edema in a mouse model of collagen-induced arthritis and reduced cytokine levels in a co-culture cell assay in a similar manner to CTLA4-Ig. ST6- and CTLA4-Ig-induced T cell-derived cytokines were examined in CD4 T cells isolated from peripheral blood mononuclear cells after cell killing through irradiation followed by flow- and magnetic-bead-assisted separation. Interestingly, compared to CTLA4-Ig, ST6 was substantially less immunogenic and more stable and durable. Our data suggest that ST6 can serve as a novel, less immunogenic therapeutic strategy for patients with RA.

Preoperative Meniscus: Pitfalls and Traps to Avoid (수술 전 반월연골: 피해야 할 함정들)

  • Hye Jin Yoo;Kyung Nam Ryu;Ji Seon Park;Wook Jin;So Young Park;Hye Jin Kang;Hyun Soo Kim;Gene Hyuk, Kwon
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.582-596
    • /
    • 2022
  • To accurately interpret knee MRI, it is important not only to know the basic meniscal anatomy but also to distinguish it from that under pathological conditions. Thus, it would be helpful to know the normal meniscus variants (false positives) that could be mistaken for meniscal tears, and tears that could easily be missed and incorrectly diagnosed as normal (false negatives). False positives include synovial recesses, meniscal flounce, the relationship between the popliteus tendon and lateral meniscus, transverse ligament, the anterior root of the meniscus, and meniscofemoral ligament. False negatives include focal radial tears, flap tears, posterior root tears, meniscocapsular separation, and discoid meniscal tears. In this pictorial essay, we reviewed the imaging data obtained in the aforementioned cases.

Recovery of $\alpha$-iron from converter dust in a steelmaking factory (제철소 전노 dust로부터 철분강 회수에 관한 연구)

  • 김미성;김미성;오재현;김태동
    • Resources Recycling
    • /
    • v.2 no.2
    • /
    • pp.27-38
    • /
    • 1993
  • In this study, we investigated the grinding and sedimentation(elutriation) process of the dusts for the effective separation of high purity iron and iron oxides. For characterization of the dust, particle size distribution and chemical composition, were examined. The results obtained in this study may be summarized as follows : 1. The converter CF(clarifier) dust of the Pohang 1st, 2nd steel making factory and EC(Evaporation Cooler), EP(Eltrostatic precititator) dust of the Kwangyang 2nd steel making factory are composed $\alpha$-Fe(21~50%), FeO(wustite)$Fe_3$$O_4$(magnetite), $Fe_2$$O_3$, CaO, $Al_2$$O_3$, $SiO_2$, and etc. 2. Pure iron has ductile characteristic in nature, particle size of the pure iron increase by increasing the grinding time. On the other hand, it is conformed that bo고 particles of hematite and magnetite become less than 325 mesh after 10 minutes grinding. 3. By applying the elutriation technique for the EC dust of the Kwangyang 2nd steel making factory, the iron powder of high content more than 99.17% of pure Fe was recovered with 37.8% yield at grinding time for 40 minutes. 4. By applying the elutriation technique for the CF dust of the Pohang 2nd steel making factory, the iron powder of high content more than 98.38% of pure Fe was recovered with 44.42% yield at grinding time for 40 minutes. 5. When magnetic separation was performed using plastic bonding magnet of 70 gauss, more than 98% Fe grade of iron powder was recovered in the size range +65 -200 mesh but the recovery of it was low.

  • PDF

Stand-alone Real-time Healthcare Monitoring Driven by Integration of Both Triboelectric and Electro-magnetic Effects (실시간 헬스케어 모니터링의 독립 구동을 위한 접촉대전 발전과 전자기 발전 원리의 융합)

  • Cho, Sumin;Joung, Yoonsu;Kim, Hyeonsu;Park, Minseok;Lee, Donghan;Kam, Dongik;Jang, Sunmin;Ra, Yoonsang;Cha, Kyoung Je;Kim, Hyung Woo;Seo, Kyoung Duck;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.86-92
    • /
    • 2022
  • Recently, the bio-healthcare market is enlarging worldwide due to various reasons such as the COVID-19 pandemic. Among them, biometric measurement and analysis technology are expected to bring about future technological innovation and socio-economic ripple effect. Existing systems require a large-capacity battery to drive signal processing, wireless transmission part, and an operating system in the process. However, due to the limitation of the battery capacity, it causes a spatio-temporal limitation on the use of the device. This limitation can act as a cause for the disconnection of data required for the user's health care monitoring, so it is one of the major obstacles of the health care device. In this study, we report the concept of a standalone healthcare monitoring module, which is based on both triboelectric effects and electromagnetic effects, by converting biomechanical energy into suitable electric energy. The proposed system can be operated independently without an external power source. In particular, the wireless foot pressure measurement monitoring system, which is rationally designed triboelectric sensor (TES), can recognize the user's walking habits through foot pressure measurement. By applying the triboelectric effects to the contact-separation behavior that occurs during walking, an effective foot pressure sensor was made, the performance of the sensor was verified through an electrical output signal according to the pressure, and its dynamic behavior is measured through a signal processing circuit using a capacitor. In addition, the biomechanical energy dissipated during walking is harvested as electrical energy by using the electromagnetic induction effect to be used as a power source for wireless transmission and signal processing. Therefore, the proposed system has a great potential to reduce the inconvenience of charging caused by limited battery capacity and to overcome the problem of data disconnection.