• 제목/요약/키워드: magnetic resonance image

검색결과 949건 처리시간 0.034초

성도 자기공명 영상과 음향정보(F1/F2)를 이용한 한국어 단모음 [이, 에, 아, 오, 우, 으] 판별 (A Vowel Discrimination of Korean Monophthongs [i, e, a, o, u, ${\omega}$] Using Vocal Tract Magnetic Resonance Image and F1/F2)

  • 성철재;박종원;김귀룡
    • 대한음성학회지:말소리
    • /
    • 제56호
    • /
    • pp.103-125
    • /
    • 2005
  • We present a new method of measuring the volume and cross-sectional area of the vocal tract from magnetic resonance images. The vocal tract was divided by the 2 constriction points on the horizontal and vertical planes. The ratios of the volumes of the segment vocal tracts to that of the entire vocal tract play a crucial role in discriminating Korean monophthongs in that vowels were successfully discriminated by the ratios. The discriminant analysis also demonstrated that the acoustic parameters F1 and F2, in addition to the segment volumes, serve as significant parameters in discriminating Korean monophthongs.

  • PDF

대칭적 에코 배치 및 필터링을 통한 Fast Spin Echo 영상에서의 Gibb's 현상 개선 (Improvement of Gibb's Phenomena in Fast Spin Echo Imaging Using Symmetric Echo Arrangement and Filtering)

  • 안창범;김치영;오창현;신진교
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.79-85
    • /
    • 1997
  • Fast spin echo imaging utilizes multiple spin echoes to encode multiple k-space lines instead of multiple $T_2-weighted$ images. As results, intensities in k-space data are varying according to T2 decay, which generates Gibb's artifact in the reconstructed image. The echo time for e encoding dc block determines contrast, as is specified by the effective echo time, however, all location of other echoes to different k-space frequency blocks in fast spin echo imaging is not f fully investigated. In this study, symmetric arrangement of multiple echoes in k-space is investigated to reduce Gibb's artifact. Design of filters based on the measurement of multiple e echo intensities is also proposed in two stage manner, i.e., equalization and filtering. From s simulation and experiment, it was observed that Gibb's phenomena were substantially reduced b by the proposed methods.

  • PDF

MR PC 영상을 이용한 유체 흐름 분석 (Measurement of Flow Velocity and Flow Visualization with MR PC Image)

  • 김수정;이동혁;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.127-130
    • /
    • 1997
  • Phase-contrast(PC) methods have been used for quantitative measurements of velocity and volume flow rate. In addition, phase contrast cine magnetic resonance imaging (MRI) combines the flow dependent contrast of PC MRI with the ability of cardiac cine imaging to produce images throughout the cardiac cycle. In this method, the through-plane velocity has been encoded generally. However, the accuracy of the flow data can be reduced by the effect of flow direction, finite slice thickness, resolution, pulsatile flow pattern, and so on. In this study we calculated the error caused by misalignment of tomographic plane and flow directon. To reduce this error and encode the velocity for more complex flow, we suggested 3 directional velocity encoding method.

  • PDF

MR조영제와 분자영상 (MR Contrast Agents and Molecular Imaging)

  • 문우경
    • 대한핵의학회지
    • /
    • 제38권2호
    • /
    • pp.205-208
    • /
    • 2004
  • The two major classes of magnetic resonance (MR) contrast agents are paramagnetic contrast agents, usually based on chelates of gadolinium generating T1 positive signal enhancement, and super-paramagnetic contrast agents that use mono- or polycrystalline iron oxide to generate strong T2 negative contrast in MR images. These paramagnetic or super-paramagnetic complexes are used to develop new contrast agents that can target the specific molecular marker of the cells or tan be activated to report on the physiological status or metabolic activity of biological systems. In molecular imaging science, MR imaging has emerged as a leading technique because it provides high-resolution three-dimension maps of the living subject. The future of molecular MR imaging is promising as advancements in hardware, contrast agents, and image acquisition methods coalesce to bring high resolution in vivo imaging to the biochemical sciences and to patient care.

자기 공명 영상장치를 이용한 악관절 기능 장애에 관한 연구 (A STUDY ON TEMPOROMANDIBULAR JOINT DYSFUNCTION WITH MAGNETIC RESONANCE IMAGING AND ARTHROGRAM)

  • 김재덕
    • 치과방사선
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 1993
  • The Internal derangement of temporomandibular joint disc was evaluated by using magnetic resonance imaging and arthrogram in 5 patients having reciprocal clicking or locking and in 5 normal subjects. Parasagittal multisections on both closed and open mouth were serially obtained by using a 1.5 Tesla MR system and surface coil with CSMEMP, MPGR. MR images obtained were analized by correlating with images of arthrograms. The obtained results were as follows: 1. Displaced meniscus was clearly delineated as dark structure on MR images other than on arthrograms of closed mouth view of patient having clicking or locking. 2. The deltoid white images of synovial fluid were identified in the glenoid fossa and on the posterior surface of condyle on open mouth view and partly depicted on closed mouth view, of parasagittal sections by MPGR. 3. The greyish image of joint fluid was identified on the posterior surface of condyle on the open mouth view of parasagittal sections by CSMEMP. 4. The structural relationship among condyle, meniscus, and fluid showed the variety of images on each parasagitta1 view.

  • PDF

Primary Angiosarcoma of the Breast: MRI Findings

  • Lee, Kanghun;Seo, Kyung Jin;Whang, In Yong
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권3호
    • /
    • pp.194-199
    • /
    • 2018
  • We present image findings, especially rare MRI of a primary breast angiosarcoma with its histopathology, and also analyze the relevant medical literature reports in terms of the MRI findings. As our patient had unique features of a primary breast angiosarcoma, this case could be very helpful for future diagnosis of this rare breast malignancy by MRI.

소형견에서 섬유연골 색전성 척수증 2례 (Fibrocartilaginous Embolic Myelopathy in Two Small Breed Dogs)

  • 임지혜;정창수;변예은;김완희;이영원;권오경
    • 한국임상수의학회지
    • /
    • 제23권2호
    • /
    • pp.218-221
    • /
    • 2006
  • This report described clinical findings and Magnetic resonance image (MRI) results in two small breed dogs with fibrocartilaginous embolism (FCE). They were admitted with asymmetric acute-onset tetra/paraparesis with superficial pain sensation. In addition, there were no back pain and no progression of clinical signs. Cerebrospinal fluid and laboratory findings were evaluated. MRI revealed a similar focal intramedullary lesion of hyperintensive signals on T2-weighted images. Based on these findings, it was diagnosed as fibrocartilaginous embolic myelopathy in those two dogs.

Imaging findings in a case of Gorlin-Goltz syndrome: a survey using advanced modalities

  • Bronoosh, Pegah;Shakibafar, Ali Reza;Houshyar, Maneli;Nafarzade, Shima
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.171-175
    • /
    • 2011
  • Gorlin-Goltz syndrome is an infrequent multi-systemic disease which is characterized by multiple keratocysts in the jaws, calcification of falx cerebri, and basal cell carcinomas. We report a case of Gorlin-Goltz syndrome in a 23-year-old man with emphasis on image findings of keratocyctic odontogenic tumors (KCOTs) on panoramic radiograph, computed tomography, magnetic resonance (MR) imaging, and Ultrasonography (US). In this case, pericoronal lesions were mostly orthokeratinized odontogenic cyst (OOC) concerning the MR and US study, which tended to recur less. The aim of this report was to clarify the characteristic imaging features of the syndrome-related keratocysts that can be used to differentiate KCOT from OOC. Also, our findings suggested that the recurrence rate of KCOTs might be predicted based on their association to teeth.

Development of Quadrature Detection Surface Coil: for Functional Magnetic Resonance Imaging at 3T MRI System

  • Chu, Myung-Ja;Choe, Bo-Young;Kim, Kyung-Nam;Chung, Sung-Taek;Oh, Chang-Hyun;Lee, Hyoung-Koo;Suh, Tae-Suk
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.77-77
    • /
    • 2002
  • 목적: We has proposed a surface coil which has improved SNR compared with the standard head coil. Usually, a cylindrical head coil provide good homogeneity but less SNR than surface coil. A surface coil has better SNR at the expense of image homogeneity. In this paper, a surface coil of transmit-receive mode offers a better SNR as compared with a head coil.

  • PDF

An Unusual Case of Japanese Encephalitis Involving Unilateral Deep Gray Matter and Temporal Lobe on Diffusion-Weighted MRI

  • Seok, Hee Young;Lee, Dong Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.250-253
    • /
    • 2016
  • Acute Japanese encephalitis (JE) is an endemic viral infectious disease in various parts of Far East and Southeast Asian countries including Korea. Bilateral thalami are the most common involving sites in JE. Other areas including the basal ganglia, substantia nigra, red nucleus, pons, cerebral cortex and cerebellum may be also involved. We report an extremely unusual brain diffusion-weighted MR imaging (DWI) findings in a 53-year-old man with serologically proven JE involving unilateral deep gray matter and temporal lobe, which shows multifocal high signal intensities in left thalamus, left substantia nigra, left caudate nucleus and left medial temporal cortex on T2-weighted image and DWI with iso-intensity on apparent diffusion coefficient (ADC) map.