• 제목/요약/키워드: magnetic probe

검색결과 259건 처리시간 0.036초

축 방향 자장이 인가된 용량 결합형 라디오 주파수 플라즈마의 특성 연구 (A study on the characteristics of axially magnetized capacitively coupled radio frequency plasma)

  • 이호준;이동영;태흥식;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1066-1068
    • /
    • 1999
  • Magnetic field is commonly used in low temperature processing plasmas in order to obtain high density. E $\times$ B magnetron or surface multipole configuration were most popular. However, the properties of capacitively coupled rf plasma confined by axially applied static magnetic fields have rarely been studied. In this paper, the effects of magnetic field on the characteristics of 13.56MHz/40KHz argon plasma will be reported. Ion saturation current, electron temperature and plasma potential were measured by Langmuir probe and omissive probe. At low pressure region ($\sim$10mTorr), ion current was increased by a factor of 3 - 4 due to reduction of diffusion loss of charged particles to the wall. It was observed that magnetic field induces large time variation of the plasma potential. The experimental result was compared with particle-in-cell simulation. It was also observed that electron temperature tend to decrease with increasing magnetic induction level for 40KHz discharge.

  • PDF

IC 표면 전류 분포 측정을 위한 초소형 자기장 프로브 설계 (Design of Miniaturized Magnetic Field Probe for Measurement of IC Surface Current Distribution)

  • 이승배;전영현;김병성
    • 대한전자공학회논문지TC
    • /
    • 제46권5호
    • /
    • pp.154-161
    • /
    • 2009
  • 최근 들어 작은 면적에 고속으로 동작하는 여러 기능 블록이 집적됨에 따라, 고속 직접회로는 인접회로의 오동작을 유발하고, 무선 수신기의 감도를 떨어뜨리는 중요한 전자파 간섭원으로 부각되고 있다. 따라서 집적회로 내부에서 가장 주요한 전자파 방해원을 파악하기 위한 좀 더 정밀한 분석 도구가 필요하게 되었다. 이러한 필요성에 따라 본 논문에서는 직접회로의 표면에 흐르는 전류세기의 분포를 측정할 수 있는 고해상도 자기장 프로브를 반도체 공정을 이용하여 설계 및 제작하였다. 3층 금속 배선이 가능한 반도체 공정을 이용함으로써 프로브 두께를 기존 작업보다 약 10%정도로 감소시킬 수 있었다. 정자기 해석과 전자기 모의실험을 통해 프로브의 공간분해능 및 비자기장 성분에 의한 영향을 분석하였으며, 실제 직접회로의 표면 전류를 측정한 결과, $210{\mu}m$의 공간해 상도를 얻을 수 있음을 확인하였다.

동축 프로브 급전구조에 대한 FDTD 전원 모델들의 상호 관계에 관한 비교 연구 (A Comparative Study on Interrelation between FDTD Source Models for Coaxial-Probe Feeding Structures)

  • 현승엽
    • 한국전자파학회논문지
    • /
    • 제25권1호
    • /
    • pp.114-122
    • /
    • 2014
  • RF 및 마이크로파 대역에서 동축 프로브 급전구조에 대한 효율적인 유한 차분 시간 영역(FDTD: Finite-Difference Time-Domain) 해석을 위한 등가 전원 모델링 기법들의 상호 관계를 연구하였다. 기존에는 델타 갭(delta-gap) 또는 자기 프릴(magnetic-frill) 개념을 FDTD에 도입한 등가 전원 모델들이 여러 연구진에 의해서 개발되었다. 이러한 등가 전원 모델들의 FDTD 구현 방법과 모의 계산의 정확성은 서로 조금 다르다는 정도로만 잘 알려져 있었다. 본 논문에서는 준정적 근사(quasi-static approximation)하에서 동축-프로브 급전 구조에 대한 FDTD 등가 전원 모델들의 상호 관계를 제시하였다. FDTD 등가 전원 모델들의 적용방법에 따라 동축 급전된 원추형 모노폴 안테나의 시간영역과 주파수영역 응답을 수치계산하였다. 또한, FDTD 모의계산의 정확성과 효율성에 대한 비교 결과를 제시하였다.

핵자기공명 영상법과 핵자기공명 분광법을 위한 뒤집음-탐침의 개발에 대한 연구 (Development of inside-out probes for both Nuclear Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy)

  • 이동훈;고락길;정은기
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.309-316
    • /
    • 1995
  • 핵자기공명(Nuclear Magnetic Resonance)에서 신호 획득 시에 가장 중요한 부분중의 하나인 rf-탐침(radio-frequency-probe)은 실험대상이 되는 시료의 기하학적 모양과 획득하고자 하는 정보 등에 따라서 적절히 설계 및 제작되어야 최적의 신호를 얻을 수 있다. 일반적으로, rf-탐침은 시료를 둘러싸는 형태와 시료 표면에 위치하는 형태 등 두 가지로 제작된다. 그러나, 시료나 인체 부위가 관모양을 하고 있으며 관 모양 주위로부터의 신호를 관측하는 경우, 앞에서 기술한 두가지 형태의 탐침을 이용해서는 신호대 잡음비의 저하로 인해 만족할 만한 신호 획득이 어려워진다. 이때, 탐침을 관 모양의 시료 내부에 위치시키고, 관찰하고자 하는 부위에 최대로 가까이하며 탐침의 품격인자를 높이는 것이 최적의 신호획득에 중요한 조건이 되게 된다. 본 논문에서는 탐침을 시료 내부에 넣고 탐침 외부로부터 신호를 얻는 뒤집음-탐침을 역-솔레노이드 saddle 및 이중표면코일 등의 세가지 형태로 제작하고 최적신호의 획득에 대한 시도를 해보았고, 컴퓨터를 이용한 계산을 통하여 기하학적인 모양의 차이에 따른 rf-자기장 발생 상태를 알아보았다. 아울러, 시험시료로부터 발생되는 영상신호를 얻고 영상 영역 내에서 신호대잡음비를 측정하여 탐침들의 성능을 비교 분석했다. 본 연구에서 제작된 뒤집음-탐침의 경우, 어떠한 상품화된 탐침과 비교할 때, 뛰어난 신호대잡음비와 탐침 주위에서 매우 높은 균일성이 유지되었다. 또한, 제작된 형태의 뒤집음-탐침을 이용한 인체 진단에의 응용성은 매우 높을 것으로 예상된다.

  • PDF

Dynamic Spin Switching of Magnetic Films and Tunnel Junctions

  • Miyazaki, T.;Ando, Y.;Kubota, H.;Mizukami, Y.;Nakamura, H.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2003년도 하계학술연구발표회 및 한.일 공동심포지엄
    • /
    • pp.272-273
    • /
    • 2003
  • Spin dynamics has been investigated intensively in various kinds of fields. Most popular one is an initial permeability at high frequency. Also, magnetic after-effect such as thermal fluctuation of fine magnetic particles and disaccommodation in soft magnetic materials were extensively studied in the past. When we apply an external farce with the same frequency as that of the system being examined, the system absorbs the external energy and the precession enhances. It is called resonance in general. Among the various resonances, ferromagnetic resonance (FMR) has been used as a good tool to evaluate material constants such as saturation manetization or spin damping parameter by analyzing a resonance curve. In this talk first instinctive understanding of Gilbert spin damping and spin pumping will be explained. Then, experimental data for enhancement of Gilbert damping parameter (G) evaluated from FMR spectrum and spin precession measured by a time resolved pump-probe method for Permalloy thin film will be introduced. Finally, magnetization reversal observed by air-coplanar probe will be given.

  • PDF

Prototype Milli Gauss Meter Using Giant Magnetoimpedance Effect in Self Biased Amorphous Ribbon

  • Kollu, Pratap;Yoon, Seok-Soo;Kim, Gun-Woo;Angani, C.S.;Kim, Cheol-Gi
    • Journal of Magnetics
    • /
    • 제15권4호
    • /
    • pp.194-198
    • /
    • 2010
  • In our present work, we developed a GMI (giant magnetoimpedance) sensor system to detect magnetic fields in the milli gauss range based on the asymmetric magnetoimpedance (AGMI) effect in Co-based amorphous ribbon with self bias field produced by field-annealing in open air. The system comprises magnetoimpedance sensor probe, signal conditioning circuits, A/D converter, USB controller, notebook computer, and program for measurement and display. Sensor probe was constructed by wire-bonding the cobalt based amorphous ribbon with dimensions $10\;mm\;{\times}\;1\;mm\;{\times}\;20\;{\mu}m$ on a printed circuit board. Negative feedback was used to remove the hysteresis and temperature dependence and to increase the linearity of the system. Sensitivity of the milli gauss meter was 0.3 V/Oe and the magnetic field resolution and environmental noise level were less than 0.01 Oe and 2 mOe, respectively, in an unshielded room.

자장감쇠법을 이용한 $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag 초전도선재의 접합저항 측정 (Measurement of Joint Resistance of $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag Superconducting Tape by Field decay Technique)

  • 김정호;이승묵;주진호
    • Progress in Superconductivity
    • /
    • 제14권1호
    • /
    • pp.1-10
    • /
    • 2012
  • We fabricated a closed coils by using resistive-joint method and the joint resistance of the coils were estimated by field decay technique in liquid nitrogen. We used the Runge-kutta method for the numerical analysis to calculate the decay properties. The closed coil was wound by $(Bi,Pb)_2Sr_2Ca_2Cu_3O_x$/Ag tape. Both ends the tape were overlapped and soldered to each other. The current was induced in a closed coils by external magnetic flux density. Its decay characteristic was observed by means of measuring the magnetic flux density generated by induced current at the center of the closed coil with hall sensor. The joint resistance was calculated as the ratio of the inductance of the loop to the time constants. The joint resistances were evaluated as a function of critical current of loop, contact length, sweep time, and external magnetic flux density in a contact length of 7 cm. It was observed that joint resistance was dependent on contact length of a closed coil, but independent of critical current, sweep time, and external magnetic flux density. The joint resistance was measured to be higher for a standard four-probe method, compared with that for the field decay technique. This implies that noise of measurement in a standard four-probe method is larger than that of field decay technique. It was estimated that joint resistance was $8.0{\times}10^{-9}{\Omega}$ to $11.4{\times}10^{-9}{\Omega}$ for coils of contact length for 7 cm. It was found that 40Pb/60Sn solder are unsuitable for persistent mode.

Oblate Spheroidal 좌표계를 이용한 자기 편형요크내의 자장 해석에 관한 연구 (A Study on the Analysis of Magnetic Field in Magnetic Deflection Yoke Based on the Oblate Spheroidal coordinates)

  • 서정두;유형선
    • 한국정밀공학회지
    • /
    • 제10권3호
    • /
    • pp.117-124
    • /
    • 1993
  • This paper presents the study on the magnetic field analysis of magnetid deflection yoke using integral equation method. An integral equation method is developed for the computer modeling of the magnetic fields produced by color CRT and T.V. deflection yoke. Deflection of electron beams using magnetic fields is applied in a variety of display instruments such as te.evision receivers, electron probe instruments, etc. The magnetic field is solved by dividing these into the finite elements in the whole domain : the saddle coil which deflects the electron heam horizontally, the toroidal coil which deflects it vertically, magnetic core which enhances the magnetid fields genterated by the both coils. Using oblate spheroidal coordinates, this paper has had an easier access to the shape of magnetic deflection yoke chasing the boundaries than other coordinates.

  • PDF

Combline 공진기 내의 결합구조 (Coupling Structures in Combline Resonators)

  • 김병욱;김영수
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2002년도 종합학술발표회 논문집 Vol.12 No.1
    • /
    • pp.361-365
    • /
    • 2002
  • Three types of the coupling structures in combline resonators are presented: magnetic, electric, and mixed coupling structures. The magnetic coupling structure is provided by the window, and the electric coupling is provided by the electric probe. The mixed coupling structure which is the superposition of the magnetic and electric coupling structures, is proposed for the electric coupling in combline resonators with easy tuning capability. The responses of each coupling structure are shown. A 4-pole combline filter is designed and fabricated as an application of those coupling structures, and shows good filter responses.

  • PDF