• Title/Summary/Keyword: magnetic measurements

Search Result 777, Processing Time 0.032 seconds

Gravity and Magnetic Surverys for Volcanic Rocks in Yeoncheon Area, kyonggi-do (경기도 인천지역 분포하는 화산암류에 대한 중력 및 자력 탐사 연구)

  • 박혁진
    • Economic and Environmental Geology
    • /
    • v.32 no.6
    • /
    • pp.645-651
    • /
    • 1999
  • The gravity and magnetic measurements have been obtained from 34 stations with 50m intervals along the survey line positioned between Jangtanri and sindapri for studying subsurface geology and structures of the volcanic rocks in Yeoncheon area. The Bouguer gravity and magnetic anomaly values were evaluated from the reduction of the field observation, and then interpreted by Nettleton's method and maximum-pepth rules, are approximately 160m based on magnetic data and 135m based on gravity data. High Bouguer gravity anomaly zone between 0m in Jangtanri and 900m along the survery line, is caused by thick and high density, older dasalt which is positioned beneath jijangbong tuff breccia, and this result corresponds to the interpretation result based on magnetic anomly. Lower gravity and magnetic anomaly zones ariund 900m are caused by between 1300m and 1550m are caused by high density of Quarternary basalt exposed in the surface, and lower gravity and magnetic anomalies at 200m and 1250m are caused by faults.

  • PDF

The Effect of Roll and Pitch Motion on Ship Magnetic Signature

  • Birsan, Marius;Tan, Reinier
    • Journal of Magnetics
    • /
    • v.21 no.4
    • /
    • pp.503-508
    • /
    • 2016
  • The roll- and pitch-induced eddy currents create a magnetic field that contributes to the total magnetic signature of naval vessels. The magnetic signature is of concern, as it exposes the ship to the threat of modern influence mines. It is estimated that the eddy current is the second most important source contributing to a ship's underwater magnetic field following the ferromagnetic effect. In the present paper, the finite element (FE) method is used to predict the eddy current signature of a real ship. The FE model is validated using the measurements of the Canadian research vessel CFAV QUEST at the Earth's Field Simulator (EFS) in Schirnau, Germany. Modeling and validation of the eddy current magnetic signature for a real ship represents a novelty in the field. It is shown that the characteristics of this signature depend on frequency. Based on these results, a ship's degaussing system could be improved to cancel both the ferromagnetic and the eddy current contribution to the magnetic signature simultaneously, reducing the susceptibility to sea mines.

Performance Enhancement and Countermeasure for GPS Failure of GPS/INS Navigation System of UAV Through Integration of 3D Magnetic Vector

  • No, Heekwon;Song, Junesol;Kim, Jungbeom;Bae, Yonghwan;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.7 no.3
    • /
    • pp.155-163
    • /
    • 2018
  • This study examined methods to enhance navigation performance and reduce the divergence of navigation solutions that may occur in the event of global positioning system (GPS) failure by integrating the GPS/inertial navigation system (INS) with the three-dimensional (3D) magnetic vector measurements of a magnetometer. A magnetic heading aiding method that employs a magnetometer has been widely used to enhance the heading performance in low-cost GPS/INS navigation systems with insufficient observability. However, in the case of GPS failure, wrong heading information may further accelerate the divergence of the navigation solution. In this study, a method of integrating the 3D magnetic vector measurements of a magnetometer is proposed as a countermeasure for the case where the GPS fails. As the proposed method does not require attitude information for integration unlike the existing magnetic heading aiding method, it is applicable even in case of GPS failure. In addition, the existing magnetic heading aiding method utilizes only one-dimensional information in the heading direction, whereas the proposed method uses the two-dimensional attitude information of the magnetic vector, thus improving the observability of the system. To confirm the effect of the proposed method, simulation was performed for the normal operation and failure situation of GPS. The result confirmed that the proposed method improved the accuracy of the navigation solution and reduced the divergence speed of the navigation solution in the case of GPS failure, as compared with that of the existing method.

Analysis and reduction of thermal magnetic noise in liquid-He dewar for sensitive low-field nuclear magnetic resonance measurements

  • Hwang, S.M.;Yu, K.K.;Lee, Y.H.;Kang, C.S.;Kim, K.;Lee, S.J.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.20-23
    • /
    • 2013
  • For sensitive measurements of micro-Tesla nuclear magnetic resonance (${\mu}T$-NMR) signal, a low-noise superconducting quantum interference device (SQUID) system is needed. We have fabricated a liquid He dewar for an SQUID having a large diameter for the pickup coil. The initial test of the SQUID system showed much higher low-frequency magnetic noise caused by the thermal magnetic noise of the aluminum plates used for the vapor-cooled thermal shield material. The frequency dependence of the noise spectrum showed that the noise increases with the decrease of frequency. This behavior could be explained from a two-layer model; one generating the thermal noise and the other one shielding the thermal noise by eddy-current shielding. And the eddy-current shielding effect is strongly dependent on the frequency through the skin-depth. To minimize the loop size for the fluctuating thermal noise current, we changed the thermal shield material into insulated thin Cu mesh. The magnetic noise of the SQUID system became flat down to 0.1 Hz with a white noise of 0.3 $fT/{\surd}Hz$, including the other noise contributions such as SQUID electronics and magnetically shielded room, etc, which is acceptable for low-noise ${\mu}T$-NMR experiments.

Electronic and Magnetic Properties of Ti1-xMxO2-δ (M=Co and Fe) Thin Films Grown by Sol-gel Method

  • Kim, Kwang-Joo;Park, Young-Ran;Ahn, Geun-Young;Kim, Chul-Sung;Park, Jae-Yun
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.109-112
    • /
    • 2005
  • Electronic and magnetic properties of $Ti_{1-x}M_xO_{2-\delta}$ (M=Co and Fe) thin films grown by sol-gel method have been investigated. Anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films were successfully grown on $Al_2O_3$ (0001) substrates and exhibited p-type electrical conductivity while the undoped films n-type conductivity. Room temperature vibrating sample magnetometry measurements on the anatase and rutile $Ti_{1-x}Co_xO_{2-\delta}$ films with same x ($=4.8 at.{\%}$) showed quite similar magnetic hysteresis curves with the saturation magnetic moment of $\~4 {\mu}_B$ per Co ion despite their differences in structural and electronic properties. Such giant magnetic moment is attributable to the unquenched orbital moment of the $Co^{2+}$ ions substituting the octahedral $Ti^{4+}$ sites. Similar ferromagnetic behavior was observed for $Ti_{1-x}Fe_xO_{2-\delta}$ films that are highly resistive compared to the Co doped samples. Saturation magnetic moment was found to decrease for higher x, i.e., $\~2$ and $\~1.5 {\mu}_B$ per Fe ion for x=2.4 and 5.8 at. $\%$, respectively. Conversion electron $M\ddot{o}ssbauer$ spectroscopy measurements predicted the coexistence of $Fe^{2+}$ and $Fe^{3+}$ ions at the octahedral sites of $Ti_{1-x}Fe_xO_{2-\delta}$.

Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

Nuclear Magnetic Resonance of a Layered Organic-Inorganic Hybrid System (C8H17NH3)2SnCl6

  • Lee, Kyu Won;Lee, Cheol Eui
    • Journal of Magnetics
    • /
    • v.9 no.1
    • /
    • pp.1-4
    • /
    • 2004
  • Three successive phase transitions in bis-n-octhylammonium hexachlorostannate, $(n-C_8H_{17}NH_3)_2SnCl_6$, were studied by means of the ^1H nuclear magnetic resonance linewidth and spin-lattice relaxation measurements. Unlike the compounds with longer hydrocarbon chains, the order-disorder and conformational nature were found to coexist in the phase transitions.

A METHOD FOR DETERMINING MAGNETIC HELICITY OF SOLAR ACTIVE REGIONS FROM SOHO/MDI MAGNETO GRAMS

  • CHAE JONGCHUL;JEONG HYEWON
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.295-298
    • /
    • 2005
  • Recently a big progress has been made on the measurements of magnetic helicity of solar active regions based on photospheric magnetograms . In this paper, we present the details of Chae's method of determining the rate of helicity transfer using line-of-sight magnetograms such as taken by SORO /MDI. The method is specifically applied to full-disk magnetograms that are routinely taken at 96-minute cadence.

EFFECT OF THE MICROSTRUCTURE ON MAGNETIC PROPERTIES OF $Nd_{2}(Fe,Co)_{14}B_{1}Ga$-BASED ALLOYS DURING HDDR PROCESS

  • Jeung, W.Y.;Lee, S.H.;Vintaikin, B.E.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.408-411
    • /
    • 1995
  • Microstructure and magnetic properties of $Fe-Nd_{13.5}-Co_{15}-B_{6-8}Ga_{0-1}-Zr_{0.2-1}$ alloys during HDDR process were studied. $ZrB_{2}$ phase was detected and identified by X-Ray diffraction. Influence of Ga, Zr and Ga+Zr additions on phase relations at different stages of HDDR process was studied by X-ray diffraction and magnetic measurements.

  • PDF

ESR and Magnetization Study of $La_0.7Ca_0.3MnO_3$

  • Joh, Keon Woo;Lee, Chang Hoon;Lee, Cheol Eui;Jeong, Yoon Hee
    • Journal of Magnetics
    • /
    • v.5 no.1
    • /
    • pp.9-12
    • /
    • 2000
  • Electron spin resonance and magnetization measurements were carried out on $La_0.7Ca_0.3MnO_3$ in the ferromagnetic as well as paramagnetic phases. Evidence of an inhomogeneous magnetic structure, consisting of ferro-magnetic microregions embedded in an antiferromagnetic matrix near $T_c$, as well as similar local magnetic structures above and below $T_c$, were found.

  • PDF