• 제목/요약/키워드: magnetic intensity

검색결과 891건 처리시간 0.031초

자성유체의 자기적 거동특성을 이용한 광 스위치에 관한 연구 (A study on the optical switch using magnetic behavior of magnetic fluids)

  • 최범규;오재근;김도형;송관민
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.16-21
    • /
    • 2005
  • This paper presents the development of the optical switch using magnetic behavior of magnetic fluids, which is expected to be used broadly in high-speed information communication. The magnetic fluids for switching an incident light, have the magnetic characteristics of magnetic materials and fluidity of liquids, simultaneously. The relations are derived between the intensity of magnetic field and the angle of optical fiber which is bent by a behavior of magnetic fluid when the magnetic field is applied. When optical switch is implemented by the movement of liquid using magnetic fluid, the existing problem of durability for optical switch will be improved. Thus, this study shows the feasibility of the application for the optical switches using magnetic fluids.

초전도 자기 검출소자 (Magnetic Field Sensor by Using Superconductor)

  • 이상헌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.86-88
    • /
    • 2002
  • The relationship between electrical properties of superconductor and externally allied magnetic field was studied to develop a magnetic field polarity sensor. The behavior was related to the magnetic flux trapped in the superconductor, which penetrates through the material by the external magnetic field. Electrical characteristics of the superconductor with trapped magnetic flux were extremely sensitive ta the external magnetic field and showed different responses depending on the direction of the magnetic field. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

  • PDF

자성유체 스피커의 음질 성능 및 향상에 관한 실험적 연구 (Experimental study of the sound quality performance and improvement of magnetic fluid speaker)

  • 이무연
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.6993-6997
    • /
    • 2014
  • 본 연구의 목적은 자성유체 스피커의 보이스 코일 방열 및 음질 저하 문제를 극복하기 위하여 무향실내에서 자성유체 스피커의 음 왜곡률, 음압레벨 및 주파수 특성과 같은 음질 성능 특성을 고찰하는 것이다. 이를 위하여 자성유체 스피커에서 자성유체 주입량 및 영구자석 자력을 변화시켜가면서 음압 성능을 측정하였다. 그리고 스피커의 음 왜곡률, 음압레벨 및 주파수 특성은 음향시스템 측정 프로그램인 Smarrt를 이용하여 측정하였다. 결과적으로, 자성유체의 주입량은 2.4 ml로 결정되었고, 자성유체를 주입할 경우 음 왜곡률 및 음압레벨은 향상되었다. 자성유체 스피커에서 영구자석의 자력을 8.06 mT에서 9.10 mT로 증가시킬 경우 주파수 특성 및 음압레벨은 더욱 향상되었다. 또한, 자성유체 스피커의 음 왜곡률은 일반 스피커에 비하여 약 0.01% 감소하였다.

Effects of Magnetic Field Intensities for Various Lengths of Time on Orientation of Fowl Spermatozoa

  • Pham, Du Ngoc;Shinjo, Akihisa;Sunagawa, Katsunori
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제14권10호
    • /
    • pp.1367-1373
    • /
    • 2001
  • This study used fowl sperm from three White Leghom rooster reared at our laboratory. Semen samples were exposed to the magnetic field strengths of from 650 to 5700 Gauss for one. two, or three days to investigate the influence of magnetic field on the orientation of fowl spermatozoa. Fowl spermatozoa were found to orient with their long axis of heads perpendicular to the magnetic field direction. The fowl spermatozoa were initially influenced when magnetic field intensities were from 650 to 5700 Gauss and the highest values (70.67, 72.49 and 71.79%) were found in the 5700 Gauss treatment at one, two, and three days exposure, respectively. Although percentages of the perpendicular oriented fowl spermatozoa increased along with the enhancement of the magnetic field intensity, the degree of orientation was only significantly higher in the treatments having the magnetic field strength from 1500 to 5700 Gauss than that in the control treatment at all exposure time. In addition, the experimental results also showed that the percentages of all orientational types of fowl spermatozoa (perpendicular category including upward perpendicular and downward perpendicular and parallel type consisting of leftward parallel and rightward parallel) in all treatments tended to be stable during exposure time. From the results of this study. it is suggested that (1) the diamagnetic anisotropy of the inside structural components of fowl spermatozoa induce them to orient perpendicular to the magnetic field direction, (2) the degree of orientation increased according to the enhancement of magnetic field strengths, (3) fowl spermatozoa had not an high sensitivity to the magnetic field, and the level of perpendicular orientation of fowl spermatozoa in this study is nearly similar to that of cattle sperm in the study of Suga et al. (2000).

BiPbSrCaCuO 초전도 자기검출소자 (Magnetic Field Sensor using BiPbSrCaCuO Superconductor)

  • 이상헌;이성갑;이영희
    • 한국전기전자재료학회논문지
    • /
    • 제16권5호
    • /
    • pp.429-434
    • /
    • 2003
  • The magnetic field sensor was fabricated with superconducting ceramics of BiPbSrCaCuO system. The sensor at liquid nitrogen temperature showed the increase of electrical resistance by applying magnetic field. Actually, the voltage drop across the sensor was changed from zero to a value more than 100 $\mu\textrm{V}$ by the applied magnetic field. The change of electrical resistance depended on magnetic field. The sensitivity of this sensor was 2.9 $\Omega$/T. The sensing limit was about 1.5${\times}$10$\^$-5/ T. The increase of electrical resistance by the magnetic field was ascribed to a modification of the Josephson junctions due to the penetrating magnetic flux into the superconducting material. Considering the observed properties of the superconductor with trapped magnetic flux, a magnetic sensor was fabricated to detect simultaneously both the intensity and the direction of the magnetic field.

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • 제16권3호
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

The Potential of Diffusion-Weighted Magnetic Resonance Imaging for Predicting the Outcomes of Chronic Subdural Hematomas

  • Lee, Seung-Hwan;Choi, Jong-Il;Lim, Dong-Jun;Ha, Sung-Kon;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권1호
    • /
    • pp.97-104
    • /
    • 2018
  • Objective : Diffusion-weighted magnetic resonance imaging (DW-MRI) has proven useful in the study of the natural history of ischemic stroke. However, the potential of DW-MRI for the evaluation of chronic subdural hematoma (CSDH) has not been established. In this study, we investigated DW-MRI findings of CSDH and evaluated the impact of the image findings on postoperative outcomes of CSDH. Methods : We studied 131 CSDH patients who had undergone single burr hole drainage surgery. The images of the subdural hematomas on preoperative DW-MRI and computed tomography (CT) were divided into three groups based on their signal intensity and density : 1) homogeneous (iso or low) density on CT and homogeneous low signal intensity on DW-MRI; 2) homogeneous (iso or low) density on CT and mixed signal intensity on DW-MRI; and 3) heterogeneous density on CT and mixed signal intensity on DW-MRI. On the basis of postoperative CT, we also divided the patients into 3 groups of surgical outcomes according to residual hematoma and mass effect. Results : Analysis showed statistically significant differences in surgical (A to B : p<0.001, A to C : p<0.001, B to C : p=0.129) and functional (A to B : p=0.039, A to C : p<0.001, B to C : p=0.108) outcomes and treatment failure rates (A to B : p=0.037, A to C : p=0.03, B to C : p=1) between the study groups. In particular, group B and group C showed worse outcomes and higher treatment failure rates than group A. Conclusion : CSDH with homogeneous density on CT was characterized by signal intensity on DW-MRI. In CSDH patients, performing DW-MRI as well as CT helps to predict postoperative treatment failure or complications.

Intra-Rater and Inter-Rater Reliability of Brain Surface Intensity Model (BSIM)-Based Cortical Thickness Analysis Using 3T MRI

  • Jeon, Ji Young;Moon, Won-Jin;Moon, Yeon-Sil;Han, Seol-Heui
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권3호
    • /
    • pp.168-177
    • /
    • 2015
  • Purpose: Brain surface intensity model (BSIM)-based cortical thickness analysis does not require complicated 3D segmentation of brain gray/white matters. Instead, this technique uses the local intensity profile to compute cortical thickness. The aim of the present study was to evaluate intra-rater and inter-rater reliability of BSIM-based cortical thickness analysis using images from elderly participants. Materials and Methods: Fifteen healthy elderly participants (ages, 55-84 years) were included in this study. High-resolution 3D T1-spoiled gradient recalled-echo (SPGR) images were obtained using 3T MRI. BSIM-based processing steps included an inhomogeneity correction, intensity normalization, skull stripping, atlas registration, extraction of intensity profiles, and calculation of cortical thickness. Processing steps were automatic, with the exception of semiautomatic skull stripping. Individual cortical thicknesses were compared to a database indicating mean cortical thickness of healthy adults, in order to produce Z-score thinning maps. Intra-class correlation coefficients (ICCs) were calculated in order to evaluate inter-rater and intra-rater reliabilities. Results: ICCs for intra-rater reliability were excellent, ranging from 0.751-0.940 in brain regions except the right occipital, left anterior cingulate, and left and right cerebellum (ICCs = 0.65-0.741). Although ICCs for inter-rater reliability were fair to excellent in most regions, poor inter-rater correlations were observed for the cingulate and occipital regions. Processing time, including manual skull stripping, was $17.07{\pm}3.43min$. Z-score maps for all participants indicated that cortical thicknesses were not significantly different from those in the comparison databases of healthy adults. Conclusion: BSIM-based cortical thickness measurements provide acceptable intra-rater and inter-rater reliability. We therefore suggest BSIM-based cortical thickness analysis as an adjunct clinical tool to detect cortical atrophy.

A study on the novel linear actuator using MR fluid

  • Song, Joo-Young;Ahn, Kyoung-Kwan;Ahn, Young-Kong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.296-300
    • /
    • 2004
  • A new MR cylinder with built-in valves using MR fluid (MR valve) is proposed for fluid power control systems. The MR or Magneto-Rheololgical fluid is a newly developed functional fluid whose obvious viscosity is controlled by the applied magnetic field intensity. The MR cylinder is composed of cylinder with small clearance and piston with electromagnet. The differential pressure is controlled by the applied magnetic field intensity. It has the characteristics of simple, compact and reliable structure. The size of MR cylinder and piston has ${\varphi}$60mm${\times}$259mm and ${\varphi}$58mm${\times}$136.5mm in face size respectively and 0.8mm in gap length. Through experiments on the static characteristics, it is found that the differential pressure is controlled by the applied magnetic field intensity under little influence of the flow rate, which corresponds to a pressure control valve. Effectiveness of the MR cylinder is demonstrated through the position control of one link MR manipulator.

  • PDF

Characteristics of temporomandibular joint structures after mandibular condyle fractures revealed by magnetic resonance imaging

  • Kim, Bong Chul;Lee, Yoon Chang;Cha, Hyung Seok;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.24.1-24.7
    • /
    • 2016
  • Background: This study aimed to evaluate the structural changes of temporomandibular joint immediately after condylar fractures with magnetic resonance imaging (MRI). Method: We evaluated 34 subjects of condylar fractures with MRI. The position, shape, and signal intensity of the condyle, disc, and retrodiscal tissue were analyzed with MR images. Results: Immediately after trauma, the disc was displaced with the fractured segment in almost all cases. And, the changes of signal intensity at the retrodiscal tissue were found but less related to the degree of fracture displacement. And, the high signals were observed almost at all fractured joint spaces and even at some contralateral joints. Conclusions: The displaced disc as well as the increased signal intensity of the joint space, condylar head, and retrodiscal tissue demands more attention to prevent the possible sequela of joint.