• Title/Summary/Keyword: magnetic impact

Search Result 222, Processing Time 0.025 seconds

Influence of Inorganic Ions and pH on the Photodegradation of 1-Methylimidazole-2-thiol with TiO2 Photocatalyst Based on Magnetic Multi-walled Carbon Nanotubes

  • Jiang, Yinhua;Luo, Yingying;Lu, Ziyang;Huo, Pengwei;Xing, Weinan;He, Ming;Li, Jiqin;Yan, Yongsheng
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.1
    • /
    • pp.76-82
    • /
    • 2014
  • 1-Methylimidazole-2-thiol, as a kind of mercaptans, is a typical organic pollutant which has not been efficiently removed. In this study, titanium dioxide ($TiO_2$) photocatalyst based on magnetic multi-walled carbon nanotubes (MWCNTs) was synthesized via hydrothermal and sol-gel methods. The as-prepared photocatalyst was extensively characterized by X-ray diffraction (XRD), X-ray energy diffraction spectrum (EDS), transmission electron microscope (TEM), Fourier transform infrared (FT-IR) spectra, UV-Vis diffuse reflectance spectra (UV-vis DRS) and vibrating sample magnetometer (VSM). This photocatalyst of $TiO_2$/$Fe_3O_4$/MWCNTs was proved to exhibit high photocatalytic efficiency and the photodegradation rate could reach nearly 82.7% for the degradation of 1-methylimidazole-2-thiol under ultraviolet irradiation. In addition, the results demonstrated that inorganic ions had a negative impact on photodegradation of 1-methylimidazole-2-thiol to varying degrees. Moreover, pH had a great and complex effect on photocatalytic degradation of 1-methylimidazole-2-thiol under ultraviolet irradiation.

Pseudoglandular Formation in Hepatocellular Carcinoma Determines Apparent Diffusion Coefficient in Diffusion-Weighted MRI

  • Park, In Kyung;Yu, Jeong-Sik;Cho, Eun-Suk;Kim, Joo Hee;Chung, Jae-Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.79-85
    • /
    • 2018
  • Purpose: To determine the impact of pseudoglandular formation on apparent diffusion coefficient (ADC) values of hepatocellular carcinoma (HCC) in diffusion-weighted imaging (DWI), and to validate the results using histopathological grades. Materials and Methods: We assessed 182 HCCs surgically resected from 169 consecutive patients. Each type of tumor pseudoglandular formation was categorized into "non-," "mixed-," or "pure-," based on official histopathology reports. The ADC for each tumor was independently measured, using the largest region of interest on the ADC map. Data were assessed using the analysis of variance test, with Bonferroni correction for post hoc analysis to stratify the relationship of ADCs with pseudoglandular formation, followed by subgroup analysis according to the histopathological tumor grades. Results: The mean ADC was significantly higher in pure pseudoglandular lesions (n = 5, $1.29{\pm}0.08{\times}10^{-3}mm^2/s$) than in non-pseudoglandular lesions (n = 132, $1.08{\pm}0.17{\times}10^{-3}mm^2/s$; P = 0.003) or mixed-pseudoglandular lesions (n = 45, $1.16{\pm}0.24{\times}10^{-3}mm^2/s$; P = 0.034). The ADC values and pseudoglandular formation were significantly correlated in moderately differentiated HCCs (n = 103; r = 0.307, P = 0.007), while well- (n = 19) and poorly-differentiated HCCs (n = 60) did not show significant correlation (r = 0.105 and 0.068, respectively; P = 0.600 and 0.685, respectively). Conclusion: The degree of pseudoglandular formation could be one of the determinants of ADC in DWI of HCCs-especially moderately differentiated HCCs-while its influence does not appear to be significant in well- or poorly differentiated HCCs.

Safety Verification of Mounting Flight Video and Data Recorder in the Military Aircraft (군용항공기 내 비행 영상 및 데이터 녹화기 장착에 관한 안전성 검증)

  • Jung-Hyuk Kwon;Gyeong-Nam Kim;Won-Hwa Hwang;Wang-Sang Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.5
    • /
    • pp.42-57
    • /
    • 2023
  • In this paper, to increase the research capability of flight missions and maintenance in operating military aircraft, we studied the requirements for additional mounting of flight video and data recorders and safety verification methods. The verification process of the recorder equipment itself, structural safety in the aircraft system, power and electrical safety, electromagnetic compatibility, and impact of airworthiness are described in accordance with military standards and operating environment requirements. In addition, through ground/flight tests, the results of functional operation suitable for the influence and demand of interference between the flight video and data recorder and other systems are also presented.

Cardiovascular Magnetic Resonance Versus Histopathologic Study for Diagnosis of Benign and Malignant Cardiac Tumours: A Systematic Review and Meta-Analysis

  • Sandra Nobrega;Catarina Martins da Costa;Ana Filipa Amador;Sofia Justo;Elisabete Martins
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.159-168
    • /
    • 2023
  • BACKGROUND: The gold standard for diagnosis of cardiac tumours is histopathological examination. Cardiovascular magnetic resonance (CMR) is a valuable non-invasive, radiation-free tool for identifying and characterizing cardiac tumours. Our aim is to understand CMR diagnosis of cardiac tumours by distinguishing benign vs. malignant tumours compared to the gold standard. METHODS: A systematic search was performed in the PubMed, Web of Science, and Scopus databases up to December 2022, and the results were reviewed by 2 independent investigators. Studies reporting CMR diagnosis were included in a meta-analysis, and pooled measures were obtained. The risk of bias was assessed using the Quality Assessment Tools from the National Institutes of Health. RESULTS: A total of 2,321 results was obtained; 10 studies were eligible, including one identified by citation search. Eight studies were included in the meta-analysis, which presented a pooled sensitivity of 93% and specificity of 94%, a diagnostic odds ratio of 185, and an area under the curve of 0.98 for CMR diagnosis of benign vs. malignant tumours. Additionally, 4 studies evaluated whether CMR diagnosis of cardiac tumours matched specific histopathological subtypes, with 73.6% achieving the correct diagnosis. CONCLUSIONS: To the best of our knowledge, this is the first published systematic review on CMR diagnosis of cardiac tumours. Compared to histopathological results, the ability to discriminate benign from malignant tumours was good but not outstanding. However, significant heterogeneity may have had an impact on our findings.

Characteristics for Heavy Metal Pollution in Road Dust from Daebul Industrial Complex: Classification by Particle Size and Magnetic Separation (대불산업단지 도로먼지 내 중금속류 오염 특성: 입도와 자성에 따른 구분)

  • Jeong, Hyeryeong;Choi, Jin Young;Ra, Kongtae
    • Journal of Environmental Impact Assessment
    • /
    • v.29 no.4
    • /
    • pp.252-271
    • /
    • 2020
  • In this study, we investigated physical and chemical properties such as grain size, heavy metal pollution, magnetic properties, and their environmental impacts of road dusts (RD) collected from 14 sampling points in Daebul industrial Complex. Heavy metal concentrations in RD were in the order of Fe>Zn>Cu>Pb>Cr>Ni>As>Cd>Hg, and this pollution pattern was related to major industries and traffic activities in this area. The results of the correlation analysis between heavy metal elements and particle size in RD showed that Fe and all of analyzed heavy metals had a significant correlation with each other and metal concentrations had a significantly negative correlation (p<0.05). However, due to the input of large metal particles some heavy metal concentrations in the particle fraction of >1000 ㎛ were highest. Pollution load per unit area of this fraction was the highest among the grain size fractions. Cr, Ni, Cu, Zn, Cd, Pb levels in RD decreased and the levels of Cr, Ni, Cu, Zn, Cd, and Pb were reduced to 85 (As) -22 (Ni)% of the whole after removal of MFs fraction from RD. The mean heavy metal levels in the study area did not exceed the soil contamination guide value of Korea, indicating that heavy metal levels in RD were not a concern. However, at some sampling points, Zn concentrations were exceeded the soil contamination guide value for the 3rd areas of Korea and this result indicated that further studies of the impact of RD on the surrounding environment through re-suspension or non-point pollution, and of effective management methods are required.

The Technology Impact & Problems of Superconductivity Applied Components on Future Power System in Korea (전력계통 관점에서의 초전도 전력기기 적응효과와 기술상의 과제)

  • Hong, W.P.;Sea, J.Y.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.386-392
    • /
    • 1991
  • If we rely only on the conventional technology, It may be difficult to meet the recent requirments to electric power system such as further improvement of the quality of electric power supply, technology problems environmental compatibility and so on. Nowadays, power engineers much interest in applying new technology to power system industry. It is confirmed the technology of superconductivity applied components plays an important role in solving the problems of power system, because superconductors, used in suitable applications, can make electric power equipment smaller, lighter, more efficient and perhaps with better dynamic response. Two specific applications are considered here : electric machinery (Generators, Superconducting Magnetic Energy Storage, Transformer, Current limitter) and transmission line. The paper addresses the limitation of conventional technology, the technology impact & problems of superconductivity applied components to future power system from qualitative and some quantitative viewponts. The paper close with questions posed to simulate thinking on how superonductivity might be applied to power systems on a holistic basis.

  • PDF

SIMS glancing anlge을 적용한 tunnel oxide 내 Nitorgen 깊이 분해능 향상 연구

  • Lee, Jong-Pil;Choe, Geun-Yeong;Kim, Gyeong-Won;Kim, Ho-Jeong;Han, O-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.41-41
    • /
    • 2011
  • Flash memory에서 tunnel oxide film은 electron tunnelling 현상을 이용하여 gate에 전하를 전달하는 통로로 사용되고 있다. 특히, tunnel oxide film 내부의 charge trap 현상과 불순물이 소자 특성에 직접적인 영향을 주고 있어, 후속 N2O/NO 열처리 공정에서 SiO2/Si 계면에 nitrogen을 주입하여 tunnel oxide film 특성을 개선하고 있다. 따라서 N2O/NO 열처리 공정 최적화를 위해서는 tunnel oxide film 내 N 농도와 분포에 대한 정확한 평가가 필수적이다[1]. 본 실험에서는 low energy magnetic SIMS를 이용하여 N2O로 열처리된 tunnel oxide film 내의 N농도를 보다 정확하게 평가하고자 하였다. 사용된 시료는 Si substrate에 oxidation 이후 N2O 열처리를 진행하여 tunnel oxide를 형성시켰으며, 분석 impact energy는 surface effect최소화와 최상의 depth resolution 확보를 위해 250eV를 사용하였으며, matrix effect와 mass interference를 방지하기 위해 MCs+ cluster mode[2]로 CsN signal를 검출하였다. 실험 결과, 특정 primary beam 입사각도에서 nitrogen depth resolution 저하 현상이 발생하였고, SIMS crater 표면이 매우 거칠게 나타났다. 이에, Depth resolution 저하 현상을 개선하기 위해 극한의 glancing 입사각 조건으로 secondary extraction voltage 변화를 통해 depth resolution이 개선되는 최적의 impact energy와 primary beam 입사각 조건을 확보하였다. 그 결과 nitrogen의 depth resolution은 1.6nm의 depth resolution을 확보하였으며, 보다 정확한 N 농도와 분포를 평가할 수 있게 되었다.

  • PDF

Construction of sports hall flooring with excellent properties by nanocomposites

  • Xianfang Zhang
    • Advances in nano research
    • /
    • v.16 no.2
    • /
    • pp.155-164
    • /
    • 2024
  • The rapid evolution of intelligent sports equipment and gadgets has led to the transformation of smartphones into personalized coaching devices. This transformative role is central in today's technologically advanced landscape, addressing the needs of individuals with contemporary lifestyles. The development of intelligent sports gadgets is geared towards elevating overall quality of life by facilitating sports activities, workouts, and promoting health preservation. This categorization yields two primary types of devices: smart sports devices for exercise and smart health control devices, which encompass functionalities such as blood pressure monitoring and muscle volume measurement. Illustrative examples include smart headbands, smart socks, smart wristbands, and smart shoe soles. Significantly, the global market for smart sports devices has garnered substantial popularity among enthusiasts. Moreover, the integration of sensors within these devices has instigated a revolution in group and professional sports, facilitating the calculation of impact intensity and ball speed. The utilization of various types of smart sports equipment has proliferated, encompassing applications in both sports' performance and health monitoring across diverse demographics. This article conducts an assessment of the application of nanotechnology in the continuous modeling of the magnetic electromechanical sensor integrated within smart shoe soles, with a specific emphasis on its implementation in soccer training. The exploration delves into the nuanced intersection of nanotechnology and sports equipment, elucidating the intricate mechanisms that underlie the transformative impact of these advancements.

Digital Time-Domain Simulation of Ferroresonance of Potential Transformer in the 154 kV GAS Insulated Substation

  • Shim, Eung-Bo;Woo, Jung-Wook;Han, Sang-Ok
    • KIEE International Transactions on Power Engineering
    • /
    • v.11A no.4
    • /
    • pp.9-14
    • /
    • 2001
  • This paper reports a set of digital time-domain simulation studies conducted on 154 kV wound Potential Transformer(PT) int he 154 kV Gas Insulated Substation(GIS). The Electro-Magnetic Transient Program(EMTP) is used to develop the PT model and conduct the transient studies. The accuracy of the PT model is verified through comparison of the EMTP simulation results with those obtained from the field test results. The investigations shows that the developed model can accurately predict PT transient resonance, especially, the phenomenon of ferroresonance. The model is developed not only to determine impact of transients on PT response but also to design ferroresonance suppressor devices of PT. And it can also be used to predict PT transient response on power system monitoring and protection scheme.

  • PDF

A Study Development of the Powder Metallurgy Method Using 400 Series Ferrite Stainless Steel ABS Sensor Ring (분말야금법을 이용한 400계열 페라이트 스테인레스강 ABS 센서 링 개발에 관한 연구)

  • 양현수
    • Journal of the Korea Safety Management & Science
    • /
    • v.2 no.4
    • /
    • pp.197-208
    • /
    • 2000
  • ABS sensor ring has been manufactured by powder metallurgy (P/M) method using 400 series ferrite stainless steel. The results are following. It is supposedly sufficient to use for control computer due to good experimental results of magnetic characteristics. Compared with sensor ring made by iron, 400 series ferrite stainless steel has shown a good corrosion resistance without an addition surface treatment. Thus the decreasing production process has been obtained. As a result mechanical characteristics of hardness and tensile test, 400 series ferrite stainless steel shown a good endurance when it is combined to constant velocity joint(C/V), and has a good hardness properties endurable to sand and pebble impact. The products before sintering are much more corrodible in the condition of spray test of salt water and ammonia than humidity and nitrogen condition.

  • PDF