• Title/Summary/Keyword: magnetic hysteresis curve

Search Result 54, Processing Time 0.037 seconds

Basic study on hysteresis modeling using micromagnetics for magnetic field analysis (미소자성체를 이용한 자기히스테리시스 모델 연구)

  • Cheon, Yeong-Jin;Kim, Jong-Tae;Wee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.83-85
    • /
    • 2007
  • In magnetic field analysis of electrical machines, hysteresis phenomena of B-H curves should be taken into account in order to obtain more accurate results. In this paper, the hysteresis modeling using the micromagnetics for the magnetic field analysis is investigated. In the micromagnetics, usually, it takes much CPU times. Therefore, the method for representing hysteresis phenomena by minimum modeling is investigated in order to applying it to the magnetic field analysis. First, the micromagnetics is described. Then, the method of minimum modeling is shown. Finally, the hysteresis curve obtained by the minimum modeling is demonstrated. The effect of parameters of micromagnetics on the shape of hysteresis curve is investigated.

  • PDF

Study of hysteresis model for magnetic hysteresis analysis (자화이력 해석을 위한 hysteresis 모델에 관한 연구)

  • Lee, Jeong-Jong;Song, Baik-Kee;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.871_872
    • /
    • 2009
  • This paper presents study of hysteresis model for magnetic hysteresis analysis by Preisach model. In ferromagnetic material, magnetization is non-linear and varies according to magnetic field which is called B-H curve. As hysteresis phenomenon affect on performance of motor, magnetic hysteresis analysis is essential and needed for designing motor that satisfies specification. Therefore, in this paper, methods for calculating magnetization are presented and discussed.

  • PDF

A Magnetic Hysteresis Curve Tracer for Rare Earth

  • Rhee, J.R.
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.94-100
    • /
    • 1996
  • A hysteresis loop tracer using a pulsed high magnetic field of 113.4 kOe, which is suitable for rare earth based permanent magnets, is constructed. The high pulsed magnetic field is generated by discharging a large capacitance charge (5 mF) with a voltage of 600 V into an air solenoid with the inner diameter of 14 mm, outer diameter of 36 mm and the lingth of 34 mm. A computer simulation method is used for the construction of an electromagnet to optimize the many parameters such as the discharge current, generated pulsed magnetic field intensity, thermal dissipation, capacitance, charged voltage, period of damping oscillation and solenoid geometry. By using the hysteresis loop tracer constructed in this work, we are able to measure hystersis loops of several rare earth based permanent magnets with large values of the remanent magnetization, coercvity and energy product.

  • PDF

Low-Voltage EM(Elasto-Magnetic) Sensing Technique for Tensile Force Management of PSC(Prestressed Concrete) Internal Tendon (PSC 내부 텐던의 긴장력 관리를 위한 저전압 EM 센싱 기법)

  • Park, Jihwan;Kim, Junkyeong;Eum, Ki-Young;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.2
    • /
    • pp.87-92
    • /
    • 2019
  • In this paper, we have verified a low-voltage EM(elasto-magnetic) sensing technique for tensile force management of PSC(prestressed concrete) internal tendon in order to apply the technique to actual construction sites where stable power supply is difficult. From observation of past domestic and overseas PSC structural accident cases, it was found that PS tension is very important to maintain structural stability. In this paper, we have tried to measure the tensile force from a magnetic hysteresis curve through EM sensors according to voltage value by using relation between magnetostriction and stress of ferromagnetic material based on elastic-magnetic theory. For this purpose, EM sensor of double cylindrical coil type was fabricated and tensile force test equipment for PS tendon using hydraulic tensioning device was constructed. The experiment was conducted to confirm relationship between changes of permeability and tensile force from the measurement results of the maximum / minimum voltage amount. The change of magnetic hysteresis curve with magnitude of tensile force was also measured by reducing amount of voltage step by step. As a result, the slope of estimation equation in accordance with magnitude of magnetic field decreases with the voltage reduction. But it was confirmed a similar pattern of change of magnetic permeability for the magnetic hysteresis loop. So, in this study, it is considered that it is possible to manage the tensions of PSC internal tendon using EM sensing technique in low-voltage state.

Magnetic Tunneling Effects in $Permalloy/Al_{2}O_{3}/Co$ Junction ($Permalloy/Al_{2}O_{3}/Co$ 접합의 자기터널 효과)

  • 이민숙;송현주;장현숙;김미양;이장로;이용호
    • Journal of the Korean Magnetics Society
    • /
    • v.3 no.1
    • /
    • pp.29-33
    • /
    • 1993
  • Magnetoresistance was studied for the ferromagnetic tunneling junction in $Permalloy/Al_{2}O_{3}/Co$ prepared by evaporation in a vacuum of $1{\times}10^{-6}$Torr. We measured voltage-current characteristic and magnetic valve effect of prepared ferromagnetic tunneling junction sample. We investigated field-dependency of tunnel resistance by Wheat-stone bridge method and measured magnetic hysteresis curve by vibrating sample magnetometer. The tunneling is confirmed by measuring voltage-current characteristic. The hysteresis curve of magnetoresistance corresponds well with that of magnetization. The magnetoresistance ratio ${\Delta}R/R$ is 0.6% at room temperature.

  • PDF

Meauring Method of Magnetic Particles' Coercivity Distribution and Its Applications (자성분말의 보자력 분포도 측정방법과 그 응용)

  • 홍양기;박상준;정홍식
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.3
    • /
    • pp.216-221
    • /
    • 1995
  • Both manufacturing parameters and particles' chemical composition controll coercivity and its distribution of magnetic particles. The coercivity and its distribution are important properties for high density magnetic recording, so these are used as tool for evaluation of reproducibility of magnetic particles. We report in this paper the applications of dM/dH versus H curve, which is derived from magnetic hysteresis loop, to the evaluation of coercivity distribution of magnetic particles and oxidation studies of recording metal particles. The coercivity distri-bution can be estimated from the full width half rnaximun (FWHM) and the peak shape of the dM/dH versus H curve. The peak shape of the curve depends upon distribution of particles' coercivity. The peak of dM/dH versus H curve becomes broad and lor is splitted into two or rmre peaks. It depends on uniformity of particles' coercivity. When the coercivity difference between Ba-Ferrite and ${\gamma}-Fe_{2}O_{3}$ is larger than 600 Oe, the peak becomes broad and is consequently splitted into two peaks. Ununiformly substituted Ba-Ferrite particles show broad peak. It is apparent that the analysis of the curve is one of sensitive measuring techniques for determination of coercivity distri-bution and studies on magnetic properties of substituted Ba-Ferrite and oxidation of magnetic recording metal particles.

  • PDF

The frequency and magnetic characteristics of YIG with the variation of $Al_2O_3$ additions ($Al_2O_3$조성변화에 따른 YIG의 주파수 및 자기특성)

  • 홍기원;김명호;장경욱;이준웅
    • Electrical & Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.787-794
    • /
    • 1995
  • To improvement the magnetic and frequency properties of YIG(Yttrium-Iron Garnet) in microwave region, it is investigated that the effect of $Al^{3+}$ ions on magnetic and frequency characteristics of YIG, using samples of basic YIG composition( $Y_{3}$F $e_{5}$ $O_{l2}$) added with A1$_{2}$ $O_{3}$ from 0 to 2.5 [mol%]. The measurment is conducted mainly for the structural properties and magnetical properties. The structural properties is measured using SEM(Scanning Electro Microscope), EDX(Energy-dispersive X-ray spectrometer) and XRD(X-ray diffraction equipment). The magnetical properties is measured with B-H curve tracer and impedance analyzer. As a result, it is confin-ned that the effect of eddy current loss is minimized while maintaining high saturation flux density of YIG, when YIG is added with 0.5 [mol%] of A1$_{2}$ $O_{3}$.>.>.

  • PDF

Magnetic Exchange Coupling at The Interface of MR/TbCo Thin Films (자기저항 헤드용 MR/TbCo 박막의 자기교환 결합)

  • 서정교;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • To simulate the characteristics of magnetic exchange coupling at the interface of MR/TbCo thin films, the directions of magnetizations were calculated by minimizing energy in the films. Newton method and Gauss-Seidel method were used. The width of M-H curve increased with TbCo anisotropy constant, and with the thickness of the transition region of TbCo layer. Hysteresis loop width became extremely narrow (less than 10 Oe of coercivity), when the TbCo transition region length was $400\;\AA$. Also the hysteresis loop of films with low interfacial exchange coupling constant was similiar to that of short transition region length. When interfacial exchange coupling constant was 1/100 of perfect coupling, hysteresis loop showed a coercivity of less than 10 Oe. Comparing the measured hysteresis loop of a fabricated sample with that of simulated one, exchange coupling con¬stant could be estimated.

  • PDF