A Study on The Filtration Characteristics of Magnetic Fibrous Polymeric Filter with Packing Density Profile as a New Oil Filter (윤활시스템용 오일필터로서 충전밀도 변화에 따른 자성폴리머 필터의 여과특성 연구)

  • 최기영;안병길;최웅수;권숙인;권오관
    • Tribology and Lubricants
    • /
    • v.11 no.2
    • /
    • pp.8-14
    • /
    • 1995
  • The filtration of the magnetic fibrous polymeric filter with packing density profile made of a self-bonded, nonwoven structure comprising a thermoplastic polymer and a magnetic substance was investigated using an oil filter tester, a particle quantifier and an image analyzer system. The magnetic fibrous polymeric filter showed excellent filtration efficiency compared with conventional paper filter. From the experimental results, It is deduced that the filtration mechanism of conventional paper filter is only the function of physical porosity by surface filteration. On the other hand, the newly magnetic fibrous polymeric filter is designed with a new concept in filtration mechanism. That is, it has a dual function of depth and magnetic filters by physical porosity and magnetic attraction. The newly magnetic fibrous polymeric filter has been shown to be a highly effective oil filter for lubrication systems.

Theoretical Study on Magnetic Field Application for Fine Particle Capture

  • Huang, Shan;Park, Haewoo;Jo, Youngmin
    • Particle and aerosol research
    • /
    • v.10 no.2
    • /
    • pp.45-51
    • /
    • 2014
  • Fine particle capture is facing a challenge since traditional filtration which relies on the combination of impaction, interception, diffusion has a limited efficiency for fine particle capture particularly in size from 0.1 to $0.5{\mu}m$. This paper reviewed the collection efficiency of above mechanisms, as well as magnetic mechanisms for ferromagnetic particles, and mainly studied the influencing factors of magnetic filtration. Filtration velocity, magnetic field intensity and fiber size were found to be the most important parameters for magnetic filtration.

Filtration Characteristics of Magnetic Fibrous Polymeric Filter Elements for Industrial Lub-systems (산업용 자성폴리머 필터소재의 여과특성 연구)

  • 안병길;최웅수;이용훈;정용진;권오관
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.39-47
    • /
    • 1996
  • The magnetic fibrous polymeric oil filter elements for industrial lub-systems were obtained by pneumoextrusion processing prepared from thermoplastic pqlymer (polyamide) containing a magnetic particulate filler (Ba ferrite), and treated subsequently in a magnetic fields. Using the standard laboratory oil filtration test rig, metallic particle quantifier and image analyser system, the dependence of filtration charateristics of the magnetic filter media on the parameters of porosity and magnetic properties was investigated. The pressure drops and efficiencies of lubricating filter elements were measured on the packing density and magnetised filler content of filter element. Also, the industrial lub-systems such as lubricant filters for gear test rig and electric discharge processing machine were used for testing the flitrational characteristics of tl, c magnetised filter elements. The magnetic fibrous polymeric filter material was shown to possess a highly filtration efficiency in filtering the fine ferrous particles with increasing the magnetic force of filter element. Therefore, it is expected that the magnetic fibrous polymeric filter material should be used for effective oil filrers on the industrial lub-systems.

Application of magnetic field to iron contained dust capture

  • Huang, Shan;Park, Hae-Woo;Jo, Young-Min;Park, Young-Koo;Kim, Youn-Che
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.59-65
    • /
    • 2014
  • Indoor air quality including metro subway is of recent interests in large cities. Inflow air to the inside of the train and circulating air flow through MVAC of stations contain large amount of iron based fine particles. This paper evaluated the collection of such a dust by magnetic filters as comparing to conventional particle capturing mechanisms such as inertia, direct impaction and diffusion. It was found that filtration velocity, magnetic field intensity, and fiber size were the most important parameters for magnetic filtration. Application of magnetic force obviously enhances the collection efficiency particularly in fine modes smaller than 10 mm. However, its effect was found greater in 2.5 mm than submicron particles.

The Filtrational Characteristics of Magnetic Fibrous Polymeric Filter as an Oil Filter for Automotive (자동차용 자성폴리머 오일필터의 여과특성 연구)

  • 안병길;최웅수;권오관;문탁진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.5
    • /
    • pp.179-186
    • /
    • 1996
  • The magnetic fibrous polymeric oil filter for automotive was obtained by pneumoextrusion processing prepared from thermoplastic polymer(polyamide) containing magnetic particulate filer (Ba ferrite), and treated subsequently in a magnetic fields. Using an oil filter tester and particle quantifier, the dependence of filtrational characteristics of the magnetic oil filter on the parameters of mean pore sizes and magnetic properties were analyzed. Also experimental engine-bed test of oil filters was investigated. The magnetic fibrous polymeric filter was shown to possess a highly filtration efficiency in filtering the fine metal particles with increasing the magnetic force of filter element. In this study, we knew that efficiency of magnetic fibrous polymeric filter was dependent on the magnetic strength of the filter elements.

  • PDF

Study of Magnetic Filtration for Subway MVAC Dust (지하철 공조실 미세먼지에 대한 자성포집연구)

  • Park, Hae Woo;Chung, Sang Gui;Jo, Young Min
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.37-46
    • /
    • 2015
  • Dust particles, which inflow to the subway mechanical ventilation and air conditioning(MVAC) chamber, contain a fair amount of iron compounds, approximately 25.2w/w%. This work attempted to capture those iron containing dust using magnetic filters. Average magnetization value of the test MVAC dust was 0.012 emu on 5,000 Oe, which could correspond sufficiently with the magnetic interaction. External permanent magnets provided with magnetization of iron mesh screen showing high gradient magnetic field(HGM). It resulted in the capture efficiency with 84.0 ~ 99.7% and 81.2 ~ 99.8% for $PM_{10}$ and $PM_{2.5}$ respectively. Magnetic capture was found to be closely associated with the magnetic intensity, mesh opening size and flow velocity.

Magnetic withdrawal of particles for multiple purposes in nuclear power plants

  • Kam, Dong Hoon;Jeong, Yong Hoon;Choi, Sung-Min;Yun, Jong-Il
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3979-3989
    • /
    • 2021
  • Several parametric effects on the magnetic collection have been evaluated considering dimension, strength of external magnetic field, injected velocity and particle concentration in the working fluid. Besides, accidental environments, expected in the containment of nuclear power plants, have also been addressed for the capture efficiency. The capture efficiency is especially enhanced with magnetic particle size and magnetic field strength through increased magnetic force; the non-magnetic coating thickness and fluid velocity hinder the magnetic collection. Based on the assessment, the magnetic withdrawal system can effectively capture magnetic particles even under accidental environments. Withdrawal of multifunctional magnetic particles or filtering of magnetic impurities can be effectively realized through the system.

Experimental investigation of organic fouling mitigation in membrane filtration and removal by magnetic iron oxide particles

  • Jung, Jaehyun;Sibag, Mark;Shind, Bora;Cho, Jinwoo
    • Membrane and Water Treatment
    • /
    • v.11 no.3
    • /
    • pp.223-229
    • /
    • 2020
  • Here magnetic iron oxide particles (MIOPs) were synthesized under atmospheric air and which size was controlled by regulating the flow rate of alkali addition and used for efficient removal of bovine serum albumin (BSA) from water. The MIOPs were characterized using field-emission scanning electron microscopy (FE-SEM), Fourier transformation-Infrared spectroscopy (FT-IR) and vibrating sample magnetometer (VSM). The results revealed a successful preparation of the MIOPs. The removal efficiency for BSA using MIOPs was found to be about 100% at lower concentrations (≥ 10 mg/L). The maximum adsorption of 64.7 mg/g for BSA was achieved as per the Langmuir adsorption model. In addition, microfiltration membrane for removal of BSA as model protein organic foulant is also studied. The effect of various MIOPs adsorbent sizes of 210, 680 and 1130 nm on the absorption capacity of BSA was investigated. Water permeability of the BSA integrated with the smallest size MIOPs membrane was increased by approximately 22% compared by the neat BSA membrane during dead-end filtration. Furthermore, the presence of small size MIOPs were also effective in increasing the permeate flux.

Membrane fouling control in low pressure membranes: A review on pretreatment techniques for fouling abatement

  • Arhin, Samuel Gyebi;Banadda, Noble;Komakech, Allan John;Kabenge, Isa;Wanyama, Joshua
    • Environmental Engineering Research
    • /
    • v.21 no.2
    • /
    • pp.109-120
    • /
    • 2016
  • Conventional treatment techniques cannot meet the stringent modern water quality regulations emanating from the need to provide high quality drinking water. Therefore, a number of studies have suggested low pressure membrane filtration as a worthwhile alternative. However, a major constraint to the extensive use of this technology in low and middle income countries is the high operating and maintenance costs caused by the inherent predisposition to membrane fouling. Notwithstanding, pretreatment of feed water using techniques such as coagulation, adsorption, oxidation and bio-filtration is believed to control fouling. In this review paper, the existing scientific knowledge on membrane fouling and pretreatment techniques for controlling fouling in low pressure membranes is analyzed with the aim of providing new and valuable insights into such techniques, as well as unveiling crucial issues noteworthy for further studies. Among the techniques reviewed, coagulation was observed to be the most cost-effective and will remain the most dominant in the coming years. Although oxidants and magnetic ion exchange resins can also control fouling, the propensity of oxidants to form health treating precursors and the high economic implications of magnetic ion exchange resins will hinder their adoption in developing countries.