• Title/Summary/Keyword: magnetic field communication

Search Result 188, Processing Time 0.031 seconds

Complex Permeability of 0-3 Polymer Magnetic Composites for Near-Field Communication (근역장 통신용 0-3형 고분자 자성 복합소재의 복소투자율 변화)

  • Nam, Joong-Hee;Lim, Choong Hyuck;Yun, Ji Sun;Jeong, Young-Hun;Cho, Jeong-Ho;Paik, Jong Hoo;Kim, Hyo Tae;Kim, Jong-Hee
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.6
    • /
    • pp.216-220
    • /
    • 2012
  • Magnetic properties of composite materials consisting of polymer filled with ferromagnetic powders (MnZn ferrite, Fe-Si alloy) were investigated in this study. The volume fraction of magnetic powders as fillers was varied from 70 % to 95 %. This paper presents the fabrication method of polymer magnetic composites in an effort to produce the 0-3 types of MnZn ferrite and FeSi as fillers with a proper complex permeability through the optimization of some experimental parameters. The polymer matrix composites were prepared by mixing the crushed ferrites and flaky FeSi powders homogenously with low-density resins (EPDM, epoxy). The relationships among the manufacturing technology of these materials, their filler volume fraction, as well as their complex permeability were measured and analyzed.

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

A Study on the Disk Type MHD Generator Using a Shock Tube (충격파관을 이용한 DISK형 MHD발전기에 관한 연구)

  • 배철오;신명철;김윤식;길경석
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.447-453
    • /
    • 1999
  • In MHD power generation system, enthalpy of the working gas is convened to electric power directly through expansion in generator channel. It means that electric power can be generated without a moving mechanical linkage such as turbine blades. The principle of MHD generation is based on Faraday'law of induction that eletromotive force(u$\times$B) is generated when the working gas of velocity u flows a channel in which magnetic field of strength(B) exists. In this paper, helium gas seeded with cesium is used as working gas. There are two types of generator in MHD generation; linear type faraday and disk type hall generator. Rogowski coils having the bandwidth of the 100(Hz) ~ 20(kHz) were used for measuring current flowing MHD disk channel. Optimum load resistor value of the MHD generator studied was 2.5[$\Omega$]. Disk type hall generator's generation performance is the main target of this paper, which superiors to linear type Faraday generator in many points. Isentropic efficiency and enthalpy extraction rate of disk type shock tube driven hall generator is discussed here.

  • PDF

Detecting User Activities with the Accelerometer on Android Smartphones

  • Wang, Xingfeng;Kim, Heecheol
    • Journal of Multimedia Information System
    • /
    • v.2 no.2
    • /
    • pp.233-240
    • /
    • 2015
  • Mobile devices are becoming increasingly sophisticated and the latest generation of smartphones now incorporates many diverse and powerful sensors. These sensors include acceleration sensor, magnetic field sensor, light sensor, proximity sensor, gyroscope sensor, pressure sensor, rotation vector sensor, gravity sensor and orientation sensor. The availability of these sensors in mass-marketed communication devices creates exciting new opportunities for data mining and data mining applications. In this paper, we describe and evaluate a system that uses phone-based accelerometers to perform activity recognition, a task which involves identifying the physical activity that a user is performing. To implement our system, we collected labeled accelerometer data from 10 users as they performed daily activities such as "phone detached", "idle", "walking", "running", and "jumping", and then aggregated this time series data into examples that summarize the user activity 5-minute intervals. We then used the resulting training data to induce a predictive model for activity recognition. This work is significant because the activity recognition model permits us to gain useful knowledge about the habits of millions of users-just by having them carry cell phones in their pockets.

Leveraging the Smart device for waterworks manhole management (상수도맨홀 관리를 위한 스마트 관리장치의 활용)

  • Chun, Haebok;Kim, Yeongkwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.2
    • /
    • pp.141-148
    • /
    • 2017
  • The waterworks company is in charge of managing water facilities buried underground, and the management has been centered on manholes. However, since there is no standard management manual, it has been impossible to introduce and operate a systemized managing tool by water service providers and managers, and manhole management has been carried out by individual data recording personnel for each water service provider. When the management is carried out individually, the data to be shared by other waterworks managers tend to be privatized, and consequently, it may become a big obstacle to proceed with many civil works such as emergency leak repair, road excavation, replacement of old buildings. This report introduces RFID (Radio Frequency Identification) system which is based on the magnetic field capable of IOT. It also describes the necessity of leveraging the system for smart managing of pipe management record that has been done by hand writing. The RFID system includes RFID marker, data reader, portable computer operating program, and data base server operating program. In this system, the data is managed with a single communication device, and it would be possible to share the information on the underground facilities and water treatment facilities. This RFID technology is expected to provide water service providers with opportunities to develop more scientific and modernized underground facilities information systems.

A comparison of calculated and measured values for the electric and magnetic field of 765 kV overhead transmission line (765kV 송전선로 전자계 예측계산 및 실측치 비교)

  • Maeng, JongHo;Lee, HoKwon;Lee, HyunJoong;Ahn, HunHeeSung
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1259-1260
    • /
    • 2015
  • 한국의 송전선로는 154kV, 345kV, 765kV로 분류할 수 있으며, 이 중 765kV급 송전선로는 2000년대 초반 도입된 이래 대규모 발전단지와 부하밀집 지역을 잇는 주요한 설비로 자리잡아 현재까지 안정적으로 운용되고 있다. 그러나 최근 건강을 중요시 여기는 사회적 트렌드와 전자계에 대한 일반 대중들의 관심 증가로 밀양 765kV 송전선로의 건설이 지연되어 적기 건설 및 운영에 어려움을 겪고 있다. 이러한 문제를 해소하기 위해 송 변전설비 주변지역의 보상 및 지원에 관한 법률이 2014년 7월 29일부로 시행되어 전력설비 인근 지역에 거주하는 주민들의 보상을 법으로 보장하고, 원활한 관련 문제 해소를 위해 다양한 Risk Communication 방안이 검토되고 있다. 또한 송전선로에서 주로 이슈가 되는 전기환경영향에 대해 장기 전기환경 측정시스템을 구축하여 상용선로에서 1년 이상의 전기환경 DB를 집록할 예정이다. 전력설비의 전기환경은 크게 전파장해, 소음, 전자계로 구분할 수 있으며 참고 데이터로 기상요소를 측정하는데 장기 전기환경 측정시스템에서는 이 모든 전기환경 데이터를 취득할 수 있는 설비를 갖추고 있으며, 본 논문에서는 구축된 설비를 간다하게 설명하고 해당 부지에서의 전자계 값을 모의하고 실측한 결과를 수록하였다.

  • PDF

Experimental Verification of Induction Phenomenon on Telecommunication Lines by Applying Its Occurrence Mechanisms Using an Artificial ELF Source Generator

  • Lee, Sang-Mu;Gimm, Yoon-Myoung;Eun, Chang-Soo
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.276-281
    • /
    • 2010
  • In this paper, an electromagnetic induction on a telecommunication line by the distribution line of a power provision system or a feeder line of an electrified railway system has been verified through experiments. The basic cause of induction occurrence by these practical power provision systems is the returning current through the earth. This principle has been confirmed by the experiments documented in this paper which implemented these mechanisms to incur an induction. Experimental methods were used to produce the returning current through the earth. The experiment to find a relationship between inducing strength and the distance between the two phase lines in a power provision line has also been included to confirm that, when the distance is enlarged, the induction effect increases as the cross-nullification effect of magnetic fluxes decreases. An experiment for the existence of a shielding effect by another conduction length material has been addedas a protection measure against the induction.

Nonuniformity Correction Scheme Based on 3-dimensional Visualization of MRI Images (MRI 영상의 3차원 가시화를 통한 영상 불균일성 보정 기법)

  • Kim, Hyoung-Jin;Seo, Kwang-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.4
    • /
    • pp.948-958
    • /
    • 2010
  • Human body signals collected by the MRI system are very weak, such that they may be easily affected by either external noise or system instability while being imaged. Therefore, this paper analyzes the nonuniformity caused by a design of the RF receiving coil in a low-magnetic-field MRI system, and proposes an efficient method to improve the image uniformity. In this paper, a method for acquiring 3D bias volume data by using phantom data among various methods for correcting such nonuniformity in MRI image is proposed, such that it is possible to correct various-sized images. It is shown by simulations that images obtained by various imaging methods can be effectively corrected using single bias data.

Design of Intelligent system with Fuzzy Logic for MR Sensor in destortion (Fuzzy Logic을 이용한 센서의 왜곡 현상의 지능형 추론 시스템 설계)

  • Kim, Young-Gu;Bak, Chang-Gui
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.10
    • /
    • pp.1986-1991
    • /
    • 2007
  • In this paper, we discussed, intelligent soft filter for MR(magnetoresistive) sensor. Most navigation systems today use some type of compass to determine heading direction. Using the earth's magnetic field, electronic compass based on MR(magnetoresistive) sensors can electrically resolve better then 0.1 degree rotation. Intelligent methode for soft building a one degree compass using MR(magnetoresistive) sensors will also be discussed. Compensation techniques are shown to correct for compass tilt angels and nearby ferrous material disturbances. we proved the fuzzy logic that based on the way the ham deals with inexact information is useful for MR sensors.

Influences of Operation Frequency and Excitation Current on Output Signal of Orthogonal Fluxgate Sensor Fabricated with an Amorphous Wire (아몰퍼스와이어를 이용하여 제작한 직교 플럭스게이트 센서의 출력에 미치는 구동 주파수와 여자 전류의 영향)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.1
    • /
    • pp.17-21
    • /
    • 2009
  • In this study, we have investigated that the excitation current and operation frequency dependences of the output properties of the orthogonal fluxgate sensor which was fabricated with a Co base amorphous wire and a pick-up coil. The output signal increased linearly with increase of the excitation current below 0.3 A, and decreased with increase of the excitation current over 0.6 A. It was also found that the output increased sensitively with increase of operation frequency below 1.3MHz. The output was 3.8 V at the frequency of 1.3MHz while 1.32 V at 1MHz.