검색결과 568건 처리시간 0.032초

전자기력을 이용한 박판 성형 공정 해석 및 성형성 평가 (Thin Sheet Metal Forming Process Analysis and Formability Evaluation using Electromagnetic Force)

  • 서영호;허성찬;구태완;송우진;김정;강범수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2008년도 춘계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2008
  • Electromagnetic forming (EMF) technology, which is one of the high speed forming methods, has been used for the forming process in various industry fields. Numerical approach by finite element simulation of the EMF process is presented in this study. The implicit code is used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. In addition, the body forces generated in the workpiece are used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit code. Numerical approach for a dimpled shape by EMF process is carried out and the simulated results of the dimpled shape by EMF are reviewed in view of the deformed shape and formability evaluation.

  • PDF

Degradation Evaluation of Mechanical Property for Modified 9Cr-1Mo Steel by Reversible Permeability

  • Bong, Chung-Jong;Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Eun-Kyu
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.42-45
    • /
    • 2011
  • The present work studies a nondestructive evaluation of the degradation of modified 9Cr-1Mo steel using a magnetic method based on the existence of the peaks of reversible permeability (RP) in the differential magnetization around the coercive force. The apparatus is based on detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the AC perturbing field. Results obtained for the reversible permeability and Vickers hardness on the aged samples showed the peak interval of reversible permeability (PIRP) and Vickers hardness decrease as aging time increased. The correlation between Vickes hardness and the PIRP could be used to evaluate degradation of modified 9Cr-1Mo steel.

Experimental Research on Basic design and protection of High-$T_c$ Heater Triggered Switch in Liquid Helium

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Chang, Ki-Sung;Na, Jin-Bae;Yoon, Yong-Soo;Ko, Tae-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권4호
    • /
    • pp.13-17
    • /
    • 2008
  • This paper presents experimental and characteristic analysis of hgh-$T_c$ eater-triggered witch using coated conductor (CC) in liquid and gas helium. The high temperature superconducting insert coil which can be installed in a low temperature superconducting (LTS) magnet has been proposed and researched to generate higher magnetic field for MR. Since CC could be an attractive option for HTS insert, it is important to research he characteristics of heater-triggered switch employing CC. We performed the heater test and constructed simulation model using finite element method (FEM.) We performed a protection test and observed normal zone propagation (NZP) signals to evaluate the witch with protection of magnet.

The Influence of $O_2$ Gas on the Etch Characteristics of FePt Thin Films in $CH_4/O_2/Ar$ gas

  • Lee, Il-Hoon;Lee, Tea-Young;Chung, Chee-Won
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.408-408
    • /
    • 2012
  • It is well known that magnetic random access memory (MRAM) is nonvolatile memory devices using ferromagnetic materials. MRAM has the merits such as fast access time, unlimited read/write endurance and nonvolatility. Although DRAM has many advantages containing high storage density, fast access time and low power consumption, it becomes volatile when the power is turned off. Owing to the attractive advantages of MRAM, MRAM is being spotlighted as an alternative device in the future. MRAM consists of magnetic tunnel junction (MTJ) stack and complementary metal- oxide semiconductor (CMOS). MTJ stacks are composed of various magnetic materials. FePt thin films are used as a pinned layer of MTJ stack. Up to date, an inductively coupled plasma reactive ion etching (ICPRIE) method of MTJ stacks showed better results in terms of etch rate and etch profile than any other methods such as ion milling, chemical assisted ion etching (CAIE), reactive ion etching (RIE). In order to improve etch profiles without redepositon, a better etching process of MTJ stack needs to be developed by using different etch gases and etch parameters. In this research, influences of $O_2$ gas on the etching characteristics of FePt thin films were investigated. FePt thin films were etched using ICPRIE in $CH_4/O_2/Ar$ gas mix. The etch rate and the etch selectivity were investigated in various $O_2$ concentrations. The etch profiles were studied in varying etch parameters such as coil rf power, dc-bias voltage, and gas pressure. TiN was employed as a hard mask. For observation etch profiles, field emission scanning electron microscopy (FESEM) was used.

  • PDF

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권4호
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

가동 자석형 선형 직류 전동기의 설계 (Design of a Moving Magnet Type Linear DC Motor)

  • 정헌준;김용;백수현;윤신용;김필수;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.224-227
    • /
    • 1998
  • Linear motors are increasingly employed as direct actuators replacing the more conventional systems composed by a rotating motor and a mechanical device. Linear DC motor is useful in a high speed and high accuracy positioning system with a feedback controller. Because of these advantages, linear DC motors have already been used as motors of pen recorders and magnetic disk storage devices, these are moving coil type linear DC motors as these movers are light. Moving magnet type linear DC motor has advantages at long stroke motors because its mover's feeding wires for driving is not necessary. This paper is concerned with the analysis of linear DC motor that is moving magnet type with unipolar. In order to analyze the dynamic behaviour a mathematical model based on a simplified field analysis developed. A two dimensional finite element field solution is employed in order to illustrate the effect of yoke saturation and motor performance. It is deduced the relation between the limit value of the thrust of the linear DC motor and the dimension of the yokes.

  • PDF

실리콘 공정 및 동 도금 기술을 이용한 탐침형 정보저장장치의 전자기력 미디어 구동기 제작 (Development of an Electromagnetic Actuator for Probe-based Data using Si Storage by Process and Cu Electroplating)

  • 조진우;이경일;김성현;최영진
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권4호
    • /
    • pp.225-230
    • /
    • 2004
  • An electromagnetic actuator has been designed and fabricated for Probe-based data storage applications. The actuator consists of permanent magnets(SmCo) housing and a media Platform which is connected to the Si frame by four couples of Si leaf springs. In order to generate electromagnetic force, Cu coils were electroplated under the media platform. The magnetic field distribution was calculated with 3D Finite Element Method of Maxwell 3D program. The field strength felt by Cu coils was estimated to be about 0.33T when the distance between the media platform and permanent magnets is $200\mu\textrm{m}$. The static and dynamic motions of the actuator were analyzed by FEM method with ANSYS 5.3. The measured displacements of the actuator were about $\pm$$92\mu\textrm{m}$ for input current of $\pm$40㎃ and the resonance frequency was 100Hz. The proposed electromagnetic actuator can be utilized for media driver of probe-based data storage system.

가토 두개부 골결손에서 맥동전자기장이 골형성에 미치는 영향에 관한 연구 (A STUDY OF EFFECT OF PULSED ELECTROMAGNETIC FIELDS ON OSTEOGENESIS IN RABBIT CRANIAL BONE DEFECT)

  • 황경균;이종환;김명진;심광섭;김종원
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.264-273
    • /
    • 2002
  • Pulsed electromagnetic field (PEMF) was used first to induce osteogenesis in 1974. The appliance which was consisted of the Helmholtz coil configuration have used to osteogensis. The objective of this study was to determine whether PEMF, a frequency of 100 Hz and magnetic field strength of 38 gauss applied to the calvarial defect in rabbit, could affect the induction of osteogenesis and the healing of the graft bone. This field should not produce excitation of nerve or muscle and heating the tissue. To evaluate the effect of PEMF on osteogenesis, 16 rabbit under the same condition was divided into 8 experimental groups and 8 control groups. 10 mm calvarial bone defects were formed around sagittal suture. The defect of left side was left without graft while the defect of right side was grafted by bone harvested from left side. A pulsed electromagnetic field was applied for 8 hours per day. Each group was sacrificed after 1 week, 2 weeks, 4 weeks, 8 weeks. Microscopic specimens were obtained from the calvarial bone defects and surrounding tissue using Hematoxylin-Eosin staining method. The results were as follows. 1. In the group which pulsed electromagnetic field was applied, new bone formation filled up the defect was observed after 4 and 8 weeks effectively. 2. There are no difference in the healing period for the fusion between the bone and graft bone. According to the result, the PEMF with 38 Gauss, 100 Hz was very effective in the healing of bone defect and new bone formation. So The PEMF will be useful in clinical aspect for oseteogenesis.

KSR-3 탑재 자력계를 이용한 비행정보 획득 연구 (ACQUISITION OF THE FLIGHT INFORMATION USING THE KSR-3 MAGNETOMETER)

  • 김선미;장민환;이동훈;한영석;김준;황승현;이은석;이선민;김효진;이수진
    • Journal of Astronomy and Space Sciences
    • /
    • 제20권1호
    • /
    • pp.29-42
    • /
    • 2003
  • 2002년 11월에 발사된 과학로켓 KSR-111에 자세제어를 위한 정보 획득용 3축 Fluxgate 자력계 (AIM: Attitude Information Magnetometer)와 지구 자기장 섭동 측정용 Search-Coil 자력계(SIM: Scientific Investigation Magnetometer)가 탑재되었다. SIM은 지구 자기장 중 약 10~1,000Ha주파수 대의 섭동 현상을 관측한다. AIM을 통해 측정한 지구 자기장의 DC 벡터 성분을 지구 자기장의 기준 모델인 IGRF(International Geomagnetic Reference Field)와 비교하여 로켓의 위치와 비행 상태를 파악하는 프로그램 1과 KSR-Ⅲ에서 측정된 실제 데이터를 이용해 시간에 따른 회전 각의 변화를 알아보는 프로그램 2를 개발하였다. 알고리즘 개발시 자세제어의 요소로서 데이터 처리 속도, 로켓의 비행역학 등을 고려하였고, 이로 인한 오차를 감안하기 위해 최소자승법을 사용하였다. 프로그램 2를 실행하여 얻은 값으로(항우연 자료 비교분석한 결과 내용), 자력계를 로켓의 자세 제 어용으로는 부적합하나 붐(boom)이 장착된 로켓에 탑재할 경우 지구 상충의 자기장을 측정하여 분석할 수 있다. 또한 발사 전 로켓 몸체와 마운트의 자기장을 측정하여 로켓의 자기장'분포를 미리 모델링화 할 경우 자료 처리가 훨씬 용이하다.

PSC 내부 텐던의 긴장력 관리를 위한 저전압 EM 센싱 기법 (Low-Voltage EM(Elasto-Magnetic) Sensing Technique for Tensile Force Management of PSC(Prestressed Concrete) Internal Tendon)

  • 박지환;김준경;엄기영;박승희
    • 한국전산구조공학회논문집
    • /
    • 제32권2호
    • /
    • pp.87-92
    • /
    • 2019
  • 본 논문에서는 안정적인 전력공급이 어려운 실제 현장에 적용하기 위해서 PSC 내부 텐던의 긴장력 관리를 위한 저전압 EM센싱기법을 검증하였다. 지난 국내외 PSC 구조물 사고 사례를 볼 수 있듯이, 공용간 구조적 안정성을 확보하기 위해서는 PS텐던의 긴장력 관리가 매우 중요함을 알 수 있었다. 이에 본 논문에서는 EM센서를 통해 탄성-자기이론을 기반한 강자성체의 자기변형과 응력의 관계를 이용하여 전압 크기에 따른 긴장력에 대한 자기이력곡선을 계측하고자 하였다. 이를 위해 이중 원통코일형태의 EM센서를 제작하고 유압식 인장기를 이용한 PS텐던 인장 실험 장비를 구성하였다. 실험은 단계적으로 전압을 감소시켜 긴장력 크기에 따른 자기이력곡선의 변화를 계측하면서 최대/최소 전압값에 대한 계측결과에 따른 투자율의 변화와 긴장력의 관계를 비교 분석하였다. 그 결과, 전압이 감소하여 자기장의 크기가 작아짐에 따라 추정식에 대한 상수는 상이하지만 유사한 형태의 자기이력곡선 투자율의 변화를 확인할 수 있었다. 이를 통해 본 연구에서는 저전압 상태에서 EM센싱기법을 이용한 PSC 내부 텐던에 대한 긴장력 관리가 가능할 것으로 판단된다.