• Title/Summary/Keyword: magnetic field coil

Search Result 570, Processing Time 0.012 seconds

The Design and Analysis of Linear D.C Motor with double-Side Moving Permanent Magnets (양측식 영구자석 가동형 LDM의 설계 해석)

  • Baek, S.H.;Youn, S.Y.;Lee, J.Y.;Kim, M.S.;Kim, H.R.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.965-967
    • /
    • 1993
  • In this paper, Take two perment magnets and three iron bars and wind copper wire around one or the bars. This paper demonstrate that the method or calculation yields the right results with MAXWELL-2D program package for computing magnetic field, also indicate the value to which the current in the coil has to be limited to prevent saturation of the iron or the cores. The Finally procedures for design of LDM are discussed.

  • PDF

Thin Sheet Metal Forming Process Analysis and Formability Evaluation using Electromagnetic Force (전자기력을 이용한 박판 성형 공정 해석 및 성형성 평가)

  • Seo, Y.H.;Heo, S.C.;Ku, T.W.;Song, W.J.;Kim, J.;Kang, B.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.387-390
    • /
    • 2008
  • Electromagnetic forming (EMF) technology, which is one of the high speed forming methods, has been used for the forming process in various industry fields. Numerical approach by finite element simulation of the EMF process is presented in this study. The implicit code is used to obtain the numerical model of the time-varying currents that are discharged through the coil in order to obtain the transient magnetic forces. In addition, the body forces generated in the workpiece are used as the loading condition to analyze deformation of thin sheet metal workpiece using explicit code. Numerical approach for a dimpled shape by EMF process is carried out and the simulated results of the dimpled shape by EMF are reviewed in view of the deformed shape and formability evaluation.

  • PDF

Degradation Evaluation of Mechanical Property for Modified 9Cr-1Mo Steel by Reversible Permeability

  • Bong, Chung-Jong;Ryu, Kwon-Sang;Nahm, Seung-Hoon;Kim, Eun-Kyu
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.42-45
    • /
    • 2011
  • The present work studies a nondestructive evaluation of the degradation of modified 9Cr-1Mo steel using a magnetic method based on the existence of the peaks of reversible permeability (RP) in the differential magnetization around the coercive force. The apparatus is based on detection of the voltage induced in a coil using a lock-in amplifier tuned to the frequency of the AC perturbing field. Results obtained for the reversible permeability and Vickers hardness on the aged samples showed the peak interval of reversible permeability (PIRP) and Vickers hardness decrease as aging time increased. The correlation between Vickes hardness and the PIRP could be used to evaluate degradation of modified 9Cr-1Mo steel.

Experimental Research on Basic design and protection of High-$T_c$ Heater Triggered Switch in Liquid Helium

  • Kim, Young-Jae;Yang, Seong-Eun;Park, Dong-Keun;Chang, Ki-Sung;Na, Jin-Bae;Yoon, Yong-Soo;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.13-17
    • /
    • 2008
  • This paper presents experimental and characteristic analysis of hgh-$T_c$ eater-triggered witch using coated conductor (CC) in liquid and gas helium. The high temperature superconducting insert coil which can be installed in a low temperature superconducting (LTS) magnet has been proposed and researched to generate higher magnetic field for MR. Since CC could be an attractive option for HTS insert, it is important to research he characteristics of heater-triggered switch employing CC. We performed the heater test and constructed simulation model using finite element method (FEM.) We performed a protection test and observed normal zone propagation (NZP) signals to evaluate the witch with protection of magnet.

The Influence of $O_2$ Gas on the Etch Characteristics of FePt Thin Films in $CH_4/O_2/Ar$ gas

  • Lee, Il-Hoon;Lee, Tea-Young;Chung, Chee-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.408-408
    • /
    • 2012
  • It is well known that magnetic random access memory (MRAM) is nonvolatile memory devices using ferromagnetic materials. MRAM has the merits such as fast access time, unlimited read/write endurance and nonvolatility. Although DRAM has many advantages containing high storage density, fast access time and low power consumption, it becomes volatile when the power is turned off. Owing to the attractive advantages of MRAM, MRAM is being spotlighted as an alternative device in the future. MRAM consists of magnetic tunnel junction (MTJ) stack and complementary metal- oxide semiconductor (CMOS). MTJ stacks are composed of various magnetic materials. FePt thin films are used as a pinned layer of MTJ stack. Up to date, an inductively coupled plasma reactive ion etching (ICPRIE) method of MTJ stacks showed better results in terms of etch rate and etch profile than any other methods such as ion milling, chemical assisted ion etching (CAIE), reactive ion etching (RIE). In order to improve etch profiles without redepositon, a better etching process of MTJ stack needs to be developed by using different etch gases and etch parameters. In this research, influences of $O_2$ gas on the etching characteristics of FePt thin films were investigated. FePt thin films were etched using ICPRIE in $CH_4/O_2/Ar$ gas mix. The etch rate and the etch selectivity were investigated in various $O_2$ concentrations. The etch profiles were studied in varying etch parameters such as coil rf power, dc-bias voltage, and gas pressure. TiN was employed as a hard mask. For observation etch profiles, field emission scanning electron microscopy (FESEM) was used.

  • PDF

Image Denoising for Metal MRI Exploiting Sparsity and Low Rank Priors

  • Choi, Sangcheon;Park, Jun-Sik;Kim, Hahnsung;Park, Jaeseok
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.215-223
    • /
    • 2016
  • Purpose: The management of metal-induced field inhomogeneities is one of the major concerns of distortion-free magnetic resonance images near metallic implants. The recently proposed method called "Slice Encoding for Metal Artifact Correction (SEMAC)" is an effective spin echo pulse sequence of magnetic resonance imaging (MRI) near metallic implants. However, as SEMAC uses the noisy resolved data elements, SEMAC images can have a major problem for improving the signal-to-noise ratio (SNR) without compromising the correction of metal artifacts. To address that issue, this paper presents a novel reconstruction technique for providing an improvement of the SNR in SEMAC images without sacrificing the correction of metal artifacts. Materials and Methods: Low-rank approximation in each coil image is first performed to suppress the noise in the slice direction, because the signal is highly correlated between SEMAC-encoded slices. Secondly, SEMAC images are reconstructed by the best linear unbiased estimator (BLUE), also known as Gauss-Markov or weighted least squares. Noise levels and correlation in the receiver channels are considered for the sake of SNR optimization. To this end, since distorted excitation profiles are sparse, $l_1$ minimization performs well in recovering the sparse distorted excitation profiles and the sparse modeling of our approach offers excellent correction of metal-induced distortions. Results: Three images reconstructed using SEMAC, SEMAC with the conventional two-step noise reduction, and the proposed image denoising for metal MRI exploiting sparsity and low rank approximation algorithm were compared. The proposed algorithm outperformed two methods and produced 119% SNR better than SEMAC and 89% SNR better than SEMAC with the conventional two-step noise reduction. Conclusion: We successfully demonstrated that the proposed, novel algorithm for SEMAC, if compared with conventional de-noising methods, substantially improves SNR and reduces artifacts.

Design of a Moving Magnet Type Linear DC Motor (가동 자석형 선형 직류 전동기의 설계)

  • Jung, H.J.;Kim, Y.;Baek, S.H.;Yoon, S.Y.;Kim, P.S.;Kwon, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.224-227
    • /
    • 1998
  • Linear motors are increasingly employed as direct actuators replacing the more conventional systems composed by a rotating motor and a mechanical device. Linear DC motor is useful in a high speed and high accuracy positioning system with a feedback controller. Because of these advantages, linear DC motors have already been used as motors of pen recorders and magnetic disk storage devices, these are moving coil type linear DC motors as these movers are light. Moving magnet type linear DC motor has advantages at long stroke motors because its mover's feeding wires for driving is not necessary. This paper is concerned with the analysis of linear DC motor that is moving magnet type with unipolar. In order to analyze the dynamic behaviour a mathematical model based on a simplified field analysis developed. A two dimensional finite element field solution is employed in order to illustrate the effect of yoke saturation and motor performance. It is deduced the relation between the limit value of the thrust of the linear DC motor and the dimension of the yokes.

  • PDF

Development of an Electromagnetic Actuator for Probe-based Data using Si Storage by Process and Cu Electroplating (실리콘 공정 및 동 도금 기술을 이용한 탐침형 정보저장장치의 전자기력 미디어 구동기 제작)

  • 조진우;이경일;김성현;최영진
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.4
    • /
    • pp.225-230
    • /
    • 2004
  • An electromagnetic actuator has been designed and fabricated for Probe-based data storage applications. The actuator consists of permanent magnets(SmCo) housing and a media Platform which is connected to the Si frame by four couples of Si leaf springs. In order to generate electromagnetic force, Cu coils were electroplated under the media platform. The magnetic field distribution was calculated with 3D Finite Element Method of Maxwell 3D program. The field strength felt by Cu coils was estimated to be about 0.33T when the distance between the media platform and permanent magnets is $200\mu\textrm{m}$. The static and dynamic motions of the actuator were analyzed by FEM method with ANSYS 5.3. The measured displacements of the actuator were about $\pm$$92\mu\textrm{m}$ for input current of $\pm$40㎃ and the resonance frequency was 100Hz. The proposed electromagnetic actuator can be utilized for media driver of probe-based data storage system.

A STUDY OF EFFECT OF PULSED ELECTROMAGNETIC FIELDS ON OSTEOGENESIS IN RABBIT CRANIAL BONE DEFECT (가토 두개부 골결손에서 맥동전자기장이 골형성에 미치는 영향에 관한 연구)

  • Hwang, Kyung-Gyun;Lee, Jong-Hwan;Kim, Myung-Jin;Shim, Kwang-Sup;Kim, Jong-Won
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.264-273
    • /
    • 2002
  • Pulsed electromagnetic field (PEMF) was used first to induce osteogenesis in 1974. The appliance which was consisted of the Helmholtz coil configuration have used to osteogensis. The objective of this study was to determine whether PEMF, a frequency of 100 Hz and magnetic field strength of 38 gauss applied to the calvarial defect in rabbit, could affect the induction of osteogenesis and the healing of the graft bone. This field should not produce excitation of nerve or muscle and heating the tissue. To evaluate the effect of PEMF on osteogenesis, 16 rabbit under the same condition was divided into 8 experimental groups and 8 control groups. 10 mm calvarial bone defects were formed around sagittal suture. The defect of left side was left without graft while the defect of right side was grafted by bone harvested from left side. A pulsed electromagnetic field was applied for 8 hours per day. Each group was sacrificed after 1 week, 2 weeks, 4 weeks, 8 weeks. Microscopic specimens were obtained from the calvarial bone defects and surrounding tissue using Hematoxylin-Eosin staining method. The results were as follows. 1. In the group which pulsed electromagnetic field was applied, new bone formation filled up the defect was observed after 4 and 8 weeks effectively. 2. There are no difference in the healing period for the fusion between the bone and graft bone. According to the result, the PEMF with 38 Gauss, 100 Hz was very effective in the healing of bone defect and new bone formation. So The PEMF will be useful in clinical aspect for oseteogenesis.

ACQUISITION OF THE FLIGHT INFORMATION USING THE KSR-3 MAGNETOMETER (KSR-3 탑재 자력계를 이용한 비행정보 획득 연구)

  • Kim, Sun-Mi;Jang, Min-Hwan;Lee, Dong-Hun;Han, Young-Seok;Kim, Jun;Hwang, Seung-Hyun;Lee, Eun-Seok;Lee, Sun-Min;Kim, Hyo-Jin;Lee, Su-Jin
    • Journal of Astronomy and Space Sciences
    • /
    • v.20 no.1
    • /
    • pp.29-42
    • /
    • 2003
  • The KSR-3 magnetometers consist of the fluxgate magnetometer (MAG/AIM) for acquiring the rocket flight attitude information, and the search-coil magnetometer (MAG/SIM) for the observation of the Earth's magnetic fluctuations. The position (latitude, longitude, and height) and flight condition (the transformation angle) of the rocket is measured after the data based on these two magnetometers are compared with IGRF The gap in the vector of magnetic field between the position of the launching point and an impact point is taken into account in data reduction. Angular variation of pitch, yaw, and roll can be researched when the data is applied to the coordinate system of the rocket.