• Title/Summary/Keyword: macroscopic

Search Result 1,119, Processing Time 0.026 seconds

Impact analysis of composite plate by multiscale modeling (멀티스케일 모델링에 의한 복합재료 평판의 충격해석)

  • Ji Kuk Hyun;Paik Seung Hoon;Kim Seung Jo
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.67-70
    • /
    • 2004
  • An investigation was performed to study the impact damage of the laminated composite plates caused by a low- velocity foreign object with multi-scale modeling based on the concepts of Direct Numerical Simulation (DNS)[4]. In the micro-scale part, we discretize the composite plates through separate modeling of fiber and matrix for the local microscopic analysis. A micro-scalemodel was developed for predicting the initiation of the damage and the extent of the final damage as a function of material properties, laminate configuration and the impactor's mass, etc. Anda macro-scale model was developed for description of global dynamic behavior. The connection betweenmicroscopic and macroscopic is implemented by the tied interface constraints of LS-DYNA contact card. A transient dynamic finite element analysis was adopted for calculating the contact force history and the stresses and strains inside the composites during impact resulting from a point-nose impactor. The low-velocity impact events such as contact force, deformation, etc. are simulated in the macroscopic sense and the impact damages, fiber-breakage, matrix cracking and delamination etc. are examined in the microscopic sense.

  • PDF

Vibration-mode-based story damage and global damage of reinforced concrete frames

  • Guo, Xiang;He, Zheng
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.589-598
    • /
    • 2018
  • An attempt is conducted to explore the relationship between the macroscopic global damage and the local damage of shear-type RC frames. A story damage index, which can be expressed as multi-variate functions of modal parameters, is deduced based on the tridiagonal matrix of the shear-type frame. The global damage model is also originated from structural modal parameters. Due to the connection of modal damage indexes, the relationship between the macroscopic global damage and the local story damage is reasonably established. In order to validate the derivation, a case study is carried out via an 8-story shear-type frame. The sensitivities of modal damage indexes to the location and severity of local story damages are studied. The evolution of the global damage is investigated as well. Results show that the global damage is sensitive to the degree of story damage, but it's not sensitive to its location. As the number of the damaged stories increases, more and more modes will be involved. Meanwhile, the global damage evolution curve changes from the concave shape to the S-type and then finally transforms into the convex shape. Through the proposed story damage, modal damage and global damage model, a multi-level damage assessment method is established.

Spray and Combustion Characteristics of Diesel and JP-8 in a Heavy-Duty Diesel Engine Equipped with Common-Rail Fuel Injection System (커먼레일을 장착한 대형 디젤엔진에서 디젤과 JP-8의 분무 및 연소특성 평가)

  • Jeon, Jin-Woog;Lee, Jin-Woo;Park, Jung-Seo;Bae, Choong-Sik
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3019-3025
    • /
    • 2008
  • An experimental study was performed to assess the effect of diesel and JP-8 aviation fuel on the spray characteristics, performance and emissions in a single cylinder optical diesel engine. Both fuels were injected via an 8-hole solenoid-driven injector in a common-rail injection system. For better understanding of spray development, the macroscopic images were captured with high speed camera, offered evidences for the results of performance and emissions. From macroscopic spray images, the spray tip penetration of JP-8 shorter than that of diesel while spray angle of JP-8 was wider than that of diesel. It indicates that the vaporization of JP-8 is superior to that of diesel. The lower cetane number of JP-8 resulted in increased portion of premixed combustion. The IMEP with JP-8 is lower than that of diesel-fueled engine. Especially, using JP-8 has a potential for reducing soot.

  • PDF

Macroscopic and Microscopic Traffic Simulation Using the Discrete Event system Formalism (이산 사건 형식론을 이용한 거시적 및 미시적 교통류 시뮬레이션)

  • 이종근
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 1999.04a
    • /
    • pp.110-114
    • /
    • 1999
  • 본 연구는 Zeigler가 제안한 이산 사건 시스템 형식론(DEVS: Discrete Event System Specification)을 이용한 거시적 및 미시적 교통류 시뮬레이션 방법론의 개발을 주 목적으로 한다. 도로 교통망의 모델링 방법은 미시적(microscopic)방법과 거시적(macroscopic)방법으로 분류된다. 이러한 모델링 방법들은 그 목적에 따라 각기 표현되어 제각기 사용되어 왔으나, 시스템 이론적으로 이들은 독립적 모델이 아니며 오히려 이들은 서로 동질적 추상화 관계에 있어서, 통합 모델링 환경의 구축시 미시적 모델들로부터 추상화에 의한 거시적 모델의 자동생성 등 설계상의 효율뿐 아니라 모델간의 일관성을 통한 모델 유효성을 보장할 수 있는 장점이 제공될 수 있다. 따라서, 본 논문에서는 서로 다른 표현 방법(즉, 이산시간 형식론과 이산사건 형식론)간의 통합 표현을 기반으로 양자간의 추상화 관계를 도출하고, 이를 이용한 모델 추상화를 통해 거시적 및 미시적 교통류 시뮬레이션 방법론을 제안한다. 시스템 이론적 접근을 토대로 접근한 통합 교통류 시뮬레이션 환경은 미국 Berkeley 대학 교통 연구소에서 개발한 SHIFT 등과 같은 최첨단 교통류 시뮬레이션 도구에 비하여 SES/MB를 기반을 시스템 이론적이며 소프트웨어공학적인 접근을 통하여, 1) 기존 제어 방식의 검증 및 신뢰도 분석, 2) 각종 사건, 사고의 시간별 파급효과 분석, 3) 도로건설 계획안에 대한 타당성 검토, 4) 운전자 및 관리자를 위한 예측된 교통정보 등을 제공할 수 있을 것으로 기대된다.

  • PDF

A Study on the Spray Characteristics of CRDI System with Ambient Pressure (분위기압력에 따른 CRDI 분사계의 분무특성 연구)

  • Kim, Sang-Am;Wang, Woo-Gyeong
    • Journal of Power System Engineering
    • /
    • v.18 no.6
    • /
    • pp.21-28
    • /
    • 2014
  • The studies of the spray characteristics for a CRDI engine had been advancing by many researchers, because the performance and exhaust emission were significantly affected with the spray characteristics. But most experiments of the studies would be done at low ambient pressure conditions under 2MPa. In this study, injection rates were measured with Zeuch's method at various ambient pressures to 5MPa and a constant injection pressure of 130MPa. On the same conditions, non-evaporating spray images were taken with a high speed camera and analyzed carefully with Adobe Photoshop CS3. Macroscopic spray characteristics and breakup processes in the spray could be found from the examined and analyzed data. The initial injection rate, penetration, angle, velocity and breakup of the spray were practically affected with a variation of the ambient pressure, but the injection start time and injection period were scarcely affected. As the ambient pressure was higher, the breakup of a high density droplet region in the spray was happened slowly and the main position of breakup was shifted from a front of the spray to a upstream around a nozzle. The results and techniques of spray visualization and injection rate measurement in this study would be practically effective to study a high pressure diesel spray for a CRDI.

Optimum Chycle Time and Delay Caracteristics in Signalized Street Networks (계통교통신호체계에서의 지체특성과 최적신호주기에 관한 연구)

  • 이광훈
    • Journal of Korean Society of Transportation
    • /
    • v.10 no.3
    • /
    • pp.7-20
    • /
    • 1992
  • The common cycle time for the linded signals is usually determined for the critical intersecion, just because the cpacity of a signalized intersection depends on the cycle time. This may not be optimal since the interactions between the flow and the spatial structure of the route or the area are disregarded in this case. It is common to separate the total delay incurred at signals into two parts, a deterministic or uniform delay and a stochastic or random delay. The deterministic delays and the stochastic delays on the artery particularly related to signal cycle time. For this purpose a microscopic simulation technique is used to evaluate deterministic delays, and a macroscopic simulation technique based on the principles of Markov chains is used to evaluate stochastic delays with over flow queue. As a result of investigating the relations between deterministic delays and cycle time in the various circumstances of spacing of signals and traffic volume. As for stochastic delays the resalts of comparisons of the macroscopic simulation and Newell's approximation with the microscopic simulation indicate that the former is valid for the degree of saturation less than 0.95 and the latter is for that above 0.95. Newell's argument that the total stochastic delay on an arterial is dominated by that at or caused by critical intersection is certified by the simulation experiments. The comprehensive analyses of the values of optimal cycle time with various conditions lead to a model. The cycle time determined by this model shows to be approximately 70% of that calculated by Webster's.

  • PDF

Changes of colonic endocrine cells in trinitrobenzene sulfonic acid (TNBS)-induced rat colitis

  • Back, Young-Doo;Lee, Hyeung Sik;Chung, In-Kwon;Cheon, Woo-Hyun;Ku, Sae Kwang
    • Korean Journal of Veterinary Research
    • /
    • v.51 no.2
    • /
    • pp.83-91
    • /
    • 2011
  • In this study, immunohistochemistry was used to examine the changes in the density of colonic endocrine cells - argyrophil and argentaffin cells, chromogranin A (CGA), serotonin, somatostatin and glucagon-containing cells in trinitrobenzene sulfonic acid (TNBS)-induced rat colitis. Ulcerative colitis was induced by the instillation of 10 mg of TNBS into the colonic lumen through the anus. To confirm the inducement of ulcerative colitis, the macroscopic and microscopic scores as well as the colonic myeloperoxidase (MPO) activities were monitored for 8 days after TNBS instillation in the colonic lumens. In addition, the number of argyrophil and argentaffin cells, CGA, serotonin, somatostatin and glucagon-immunoreactive cells were counted in the colonic mucosa, respectively. After TNBS instillation into the lumen of the colon from the anus in rats, increases in macroscopic and microscopic scores in the colon tissues were observed along with increases in the colonic MPO activities. Therefore, ulcerative colitis was relatively well induced by the TNBS instillations. Marked decreases in the number of colonic endocrine cells were detected in the TNBS-treated animal compared to the sham control. These results suggest that colonic endocrine cells were also disrupted by TNBS-induced ulcerative colitis.

An Investigation on the Macroscopic Spray Behavior of Nonimpinging-type Injector through Optical Measurement Technique (광학계측기법에 의한 비충돌형 인젝터의 거시적 분무거동 고찰)

  • Kim, Jong-Hyun;Jung, Hun;Kim, Jeong-Soo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.143-148
    • /
    • 2012
  • This study is an investigation on macroscopic spray behavior of nonimpinging-type injector equipped on the hydrazine thruster under development. An electron microscope is employed for the acceptance examination of injector orifice. Initial performance characteristics and spray behavior of injector are observed through the instantaneous spray images which are captured by high speed camera and Schlieren method with varying injection pressures. The injector performance is scrutinized by the velocity along with penetration length of spray and categorized by dimensionless parameters. It is confirmed that there exist varying characteristics related to the spray breakup caused by fabrication errors of injector-orifices. Unexpected spray behavior, which needs to be reexamined, is grasped at specific pressure level, as well.

  • PDF

Study on failure mechanism of line contact structures of nuclear graphite

  • Jia, Shigang;Yi, Yanan;Wang, Lu;Liu, Guangyan;Ma, Qinwei;Sun, Libin;Shi, Li;Ma, Shaopeng
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2989-2998
    • /
    • 2022
  • Line contact structures, such as the contact between graphite brick and graphite tenon, widely exist in high-temperature gas-cooled reactors. Due to the stress concentration effect, the line contact area is one of the dangerous positions prone to failure in the nuclear reactor core. In this paper, the failure mechanism of line contact structures composed of IG11 nuclear graphite column and brick were investigated by means of experiment and finite element simulation. It was found that the failure process mainly includes three stages: firstly, the damage accumulation in nuclear graphite material led to the characteristic yielding of the line contact structure, but no macroscopic failure can be observed at this stage; secondly, the stresses near the contact area met Mohr failure criterion, and a crack initiated and propagated laterally in the contact zone, that is, local macroscopic failure occurred at this stage; finally, a second crack initiated in the contact area and developed in to a Y-shape, resulting in the final failure of the structure. This study lays a foundation for the structural design and safety assessment of high-temperature gas-cooled reactors.

Permeability prediction of plain woven fabric by using control volume finite element method (검사체적 방법을 이용한 평직의 투과율 계수 예측)

  • Y. S. Song;J. R. Youn
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.181-183
    • /
    • 2002
  • The accurate permeability for preform is critical to model and design the impregnation of fluid resin in the composite manufacturing process. In this study, the in-plane and transverse permeability for a woven fabric are predicted numerically through the coupled flow model which combines microscopic with macroscopic flow. The microscopic and macroscopic flow which are flows within the micro-unit and macro-unit cell, respectively, are calculated by using 3-D CVFEM(control volume finite element method). To avoid checker-board pressure field and improve the efficiency on numerical computation, A new interpolation function for velocity is proposed on the basis of analytic solutions. The permeability of plain woven fabric is measured through unidirectional flow experiment and compared with the permeability calculated numerically. Based on the good agreement of the results, the relationships between the permeability and the structures of preform such as the fiber volume fraction and stacking effect can be understood. The reverse and the simple stacking are taken in account. Unlike past literatures, this study is based on more realistic unit cell and the improved prediction of permeability can be achieved. It is observed that in-plane flow is more dominant than transverse flow in the real flow through preform and the stacking effect of multi-layered preform is negligible. Consequently, the proposed coupled flow model can be applied to modeling of real composite materials processing.

  • PDF