• Title/Summary/Keyword: mAs test

Search Result 8,481, Processing Time 0.046 seconds

Application of Indigenous Benthic Amphipods as Sediment Toxicity Testing Organisms

  • Lee, Jung-Suk;Lee, Kyu-Tae;Kim, Dong-Hoon;Kim, Chao-Kook;Lee, Jong-Hyeon;Park, Kun-Ho
    • Ocean Science Journal
    • /
    • v.40 no.1
    • /
    • pp.17-24
    • /
    • 2005
  • A series of experiments were conducted to develop standard test organisms and test protocols for measuring sediment toxicity using candidate amphipods such as Mandibulophoxus mai, Monocorophium acherusicum, Haustorioides indivisus, and Haustorioides koreanus, which are indigenous to Korea. The relevant association of test species with sediment substrates was one of the important factors in sediment bioassay. The indigenous amphipods M mai and M. acherusicum were well associated with test sediments when they were exposed to various sediment substrates from sand to mud. The tolerant limits to various physico-chemical factors affecting bioassay results such as temperature, salinity and ammonia, as well as sensitivities to reference toxicant and contaminated sediments, were investigated using M. mai and M. acherusicum in the present study. These amphipods were tolerant to relatively wide ranges of salinity $(10{\sim}30\;psu)$ and ammonia (<50 ppm), and displayed relevant sensitivity to temperature as well. They are more sensitive to Cd, the reference toxicant, when compared to the standard test species used in other countries. Field-sediment toxicity tests revealed that M. mai would be more sensitive to sediment-associated pollutants than M. acherusicum, while the sensitivity of M. acherusicum was comparable to that of Leptocheirus plumulosus, which has been used as a standard test species in the United States of America. Overall results of this first attempt to develop an amphipod sediment toxicity test protocol in Korea indicated that M. mai and M. acherusicum would be applicable in the toxicity assessment of contaminated sediments, following the further evaluation encompassing various ecological and toxicological studies in addition to test method standardization.

SERO-EPIDEMIOLOGICAL STUDY OF BRUCELLOSIS AMONG GOATS AND SHEEP AT PESHAWAR DISTRICT

  • Ghani, M.;Siraj, M.;Zeb, A.;Naeem, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.5
    • /
    • pp.489-494
    • /
    • 1995
  • Sero-epidemiological study was carried out to observe the prevalence of brucellosis in 500 slaughtered as well as in 500 healthy animals in Peshawar district of N.W.F.P. All serum samples were subjected to four serological tests i.e. Standard Plate Test (SPT), Standard Tube Test (STT), Rivanol Test (RV) and 2, Mercapto-Ethanol Test (2, ME). The incidence of disease in 500 healthy animals tested by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test, was 2.8%, 1.8%, 1.6% and 1.2% respectively. While the incidence of brucellosis in 500 slaughter animals from Peshawar abattoir was 3.0%, 2.2%, 2.00% and 1.2% by standard plate test, standard tube test, rivanol test and 2, Mercapto-ethanol test The disease prevalence was higher in slaughtered animals as compared to healthy animals. The disease was more common in goats than sheep, also more prevalence in aged female than younger stocks. The efficacy of SPT was found more effective as compared to STT, RV, and 2, ME tests both in slaughtered as well as apparently healthy animals at Peshawar district. Standard Plate test detected 2.9%, Standard Tube test 2.0%, Rivanol test 1.8% and 2, Mercapto-ethanol test detected 1.2% positive cases in slaughtered as well as in healthy animals. So the Standard Plate Test was found to be more reliable, sensitive, and easy to performed.

Investigation About Quality Control of General X-ray System

  • Kang, Byung-Sam;Son, Jin-Hyun;Dong, Kyung-Rae
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.4
    • /
    • pp.157-164
    • /
    • 2011
  • This test is for checking investigation about quality control of general X-ray system in clinic and hospital. We compared general X-ray system of clinic and hospital which are selected freely in the metropolitan area using PMX-III and carried out quality control. Carried out Kilovoltage test, mR/mAs output test, Light filed/Beam alignment test, Half value layer test. Most of test result are appeared that failure rates of clinic is higher than hospital one. Therefore, we should lower failure rates through regular quality control and make environment which can get high quality image.

  • PDF

Perception and Practices on Screening and Vaccination for Carcinoma Cervix among Female Healthcare Professional in Tertiary Care Hospitals in Bangalore, India

  • Swapnajaswanth, M.;Suman, G.;Suryanarayana, S.P.;Murthy, N.S.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.15
    • /
    • pp.6095-6098
    • /
    • 2014
  • Background:Cervical cancer is potentially the most preventable and treatable cancer. Despite the known efficacy of cervical screening, a significant number of women do not avail themselves of the procedure due to lack of awareness. Objectives: This study was conducted to elicit information on the knowledge, attitude and practice (KAP) regarding screening (Pap test) and vaccination for carcinoma cervix among female doctors and nurses in a tertiary care hospital in Bangalore and to assess barriers to acceptance of the Pap test. Materials and Methods: A cross-sectional, descriptive study was conducted with semi-structured, self-administered questionnaire among female health professionals. The study subjects were interviewed for KAP regarding risk factors for cancer cervix, Pap test and HPV vaccination for protection against carcinoma cervix. Results: Higher proportion of doctors 45 (78.9%) had very good knowledge as compared to only 13 (13.3%) of the nurses, about risk factors for cancer cervix and Pap test (p=0.001). As many as 138(89.6%) of the study subjects had favorable attitude towards Pap test and vaccination, but 114 (73.6%) of the study subjects never had a Pap test and the most common reason 35 (31%) for not practicing was absence of disease symptoms. Conclusions: In spite of good knowledge and attitudes towards cancer cervix and Pap test being good, practice remained low among the study subjects and most common reasons for not undergoing Pap test was absence of disease symptoms. The independent predictors of ever having a Pap test done was found to be the occupation and duration of married life above 9yrs. Hence there is a strong need to improve uptake of Pap test by health professionals by demystifying the barriers.

Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test (전해부식시험을 이용한 니켈-크롬도금강판 및 아연도금강판의 내식성 비교평가시험)

  • Lee, Jae-Bong;Kim, Kyung-Wook;Park, Min-Woo;Song, Tae-Jun;Lee, Chae-Seung;Lee, Eui-Jong;Kim, Sang-Yeol
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.56-64
    • /
    • 2013
  • An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of $Fe+5{\mu}m$ $Ni+0.5{\mu}m$ Cr and $Fe+20{\mu}m$ $Ni+0.5{\mu}m$ Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of $Fe+20g/m^2$ Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS.

Evaluation of the Corrosion Resistance of Plated Ni and Ni-Cr Layers on Fe Substrate by Using Salt Spray, CASS and EC Tests (철소지 위에 형성된 니켈 및 니켈-크롬 도금층의 염수분무, 캐스, 전해부식시험법을 이용한 내식성평가)

  • 신재호;이동훈;이재봉;신성호
    • Journal of Surface Science and Engineering
    • /
    • v.36 no.4
    • /
    • pp.307-316
    • /
    • 2003
  • Salt spray, CASS(copper accelerated acetic salt spray) and EC(electrolytic corrosion) tests were performed in order to evaluate the corrosion resistance of plated Ni and Ni-Cr layers on Fe substrate. Compared with the conventional methods such as salt spray and CASS, the electrochemical method such as EC test may be beneficial in terms of test time span and quantitative accuracy. Furthermore, EC test can also become the alternative method to evaluate the resistance to corrosion of coatings by measuring the corrosion potentials of the coated layers in the electrolyte during the off-time of EC cycles. Compared with the corrosion potentials of pure iron, nickel, chromium, those potentials of coated layers can be used to anticipate the extent of corrosion. Results showed that in terms of the test time span, EC test gave 14 times and 21 times faster results than the salt spray test in cases of $5\mu\textrm{m}$ Ni and $20\mu\textrm{m}$ Ni plated layers, respectively. In addition, EC test also offered the shorter test time span than CASS test in cases of $5 \mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr, and $20\mu\textrm{m}$ Ni + $0.5\mu\textrm{m}$ Cr on Fe substrate by 78 times and 182 times, respectively. Therefore, EC test can be regarded as the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as salt spray and CASS.

Fabrication of Test Socket from BeCu Metal Sheet (BeCu 금속박판을 이용한 테스트 소켓 제작)

  • Kim, Bong-Hwan
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-38
    • /
    • 2012
  • We have developed a cost effective test socket for ball grid array(BGA) integrated circuit(IC) packages using BeCu metal sheet as a test probe. The BeCu furnishes the best combination of electrical conductivity and corrosion resistance. The probe of the test socket was designed with a BeCu cantilever. The cantilever was designed with a length of 450 ${\mu}m$, a width of 200 ${\mu}m$, a thickness of 10 ${\mu}m$, and a pitch of 650 ${\mu}m$ for $11{\times}11$ BGA. The fabrication of the test socket used techniques such as through-silicon-via filling, bonding silicon wafer and BeCu metal sheet with dry film resist(DFR). The test socket is applicable for BGA IC chip.

A Study on the Marginal Fit of Dental Prosthesis According to the W/P Ratio of Investment (매몰재의 혼수비가 치관 보철물 변연의 적합성에 미치는 영향에 관한 연구)

  • Hwang, Kyung-Sook
    • Journal of Technologic Dentistry
    • /
    • v.18 no.1
    • /
    • pp.67-72
    • /
    • 1996
  • This test is verifying for influence of W/P ratio of investment upon dental prosthesis Firstly we made 40 MOD die and divide 4 groups, each group take 0.2 different w/p ratio grade such as 0.35, 0.37, 0.39 and 0.41. The method of data analysis applied were by ANOVA, Tukey test and Mann-Whiney and Kruskal Wallis test. The finding of this study were as follows : 1. The 0.37 w/p ratio group showed most accurte margin due to $15.8{\mu}m$ gap between margin and die which keep up with manufacture's instruction and 0.35 w/p ratio group was followed as second accuracy group o 새 $48.3{\mu}m$ gap between margin and die, 0.39 w/p ratio group showed $101{\mu}m$ gap and 0.41 w/p ratio group showed $129.8{\mu}m$ gap. 2. As to the relationship of the margin accuracy between 4 different grade of w/p ratio groups, each group was statistically significant(P<0.01). Also the all groups were statistically significant except between 0.35 and 0.37 groups between 0.39 and 0.41 groups, and between 0.35 and 0.39 groups. 3. A consequence of Mann-Whitney & Kruskal-Wallis test for marginal accuracy between 4 different grade of w/p ratio was statistically significant as same as above ANOVA test result. Also Tukey test for verifying similarity from each group showed same as above.

  • PDF

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).