• 제목/요약/키워드: m-Zirconia

검색결과 318건 처리시간 0.031초

Effect of Particle Size on Zirconia Gel-Casting Process

  • Kim, In-Woong;Lee, Sang-Jin
    • 한국세라믹학회지
    • /
    • 제52권6호
    • /
    • pp.449-454
    • /
    • 2015
  • The fabrication process of zirconia gel-casting was studied to obtain dense zirconia on a large scale or with complicated shapes. As an experimental parameter, two different particle sizes ($0.1{\mu}m$ and $0.7{\mu}m$) of zirconia powder were applied to the gel-casting process. The viscosity behavior of slurries incorporating 40 vol% of zirconia powder was examined as a function of the dispersant content and the solid load to determine the optimum dispersion conditions. In addition, the gelation time with an initiator, the de-binding behavior, and the main factors affecting densification were examined. The densification of the gel-casted zirconia green body depended on the mixing ratio between the monomer and the dimer and on the zirconia particle size. A green body with a small particle size of $0.1{\mu}m$ showed less densification, with a relative density of 93%. This may be due to the excess number of bubbles created through interactions between the larger particle surface and polymer additives during the ball-milling process.

Amperometric Glucose Biosensor Based on Sol-Gel-Derived Zirconia/Nafion Composite Film as Encapsulation Matrix

  • Kim, Hyun-Jung;Yoon, Sook-Hyun;Choi, Han-Nim;Lyu, Young-Ku;Lee, Won-Yong
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권1호
    • /
    • pp.65-70
    • /
    • 2006
  • An amperometric glucose biosensor has been developed based on the use of the nanoporous composite film of sol-gel-derived zirconia and perfluorosulfonated ionomer, Nafion, for the encapsulation of glucose oxidase (GOx) on a platinized glassy carbon electrode. Zirconium isopropoxide (ZrOPr) was used as a sol-gel precursor for the preparation of zirconia/Nafion composite film and the performance of the resulting glucose biosensor was tuned by controlling the water content in the acid-catalyzed hydrolysis of sol-gel stock solution. The presence of Nafion polymer in the sol-gel-derived zirconia in the biosensor resulted in faster response time and higher sensitivity compared to those obtained at the pure zirconia- and pure Nafion-based biosensors. Because of the nanoporous nature of the composite film, the glucose biosensor based on the zirconia/Nafion composite film can reach 95% of steady-state current less than 5 s. In addition, the biosensor responds to glucose linearly in the range of 0.03-15.08 mM with a sensitivity of 3.40 $\mu$A/mM and the detection limit of 0.037 mM (S/N = 3). Moreover, the biosensor exhibited good sensor-to-sensor reproducibility (~5%) and long-term stability (90% of its original activity retained after 4 weeks) when stored in 50 mM phosphate buffer at pH 7 at 4 ${^{\circ}C}$.

전부도재수복물을 위한 유색 및 무색 지르코니아 세라믹의 굴곡강도 (Flexure Strength of Various Colored and Uncolored Zirconia Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;이일권
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.119-130
    • /
    • 2007
  • Purpose: This investigation was designed to estimate the flexure strength, density, and microstructure of the colored and uncolored zirconia oxide ceramics for fixed partial denture. Material and Methods: LAVATM All Ceramic(3M-ESPE, USA), Cercon Smart Ceramic(Dentsply, USA), and Z-match Ceramic(DentAim, Korea) were used for this study. All specimen was fabricated by ASTM C1161. After preparing $25{\times}2{\times}1.5mm$ of rectangular column and sitting rectangular column on universal test machine (UTM), external supporting point distance is 20.0 mm, internal supporting point distance is 10.0 mm. Specimen was loaded with 0.2 mm/min of cross head speed until fracture and at the time of broken of specimen, measuring loading value with PC software. Results: The results were obtained as follows: 1. Flexure strength of uncolored zirconia was higher than that of colored zirconia. 2. In uncolored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics, and it showed statistical difference between LAVATM Ceramic and Cercon Smart Ceramic (P<0.05). 3. In colored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics too, but they did not show statistical difference (p>0.05). 4. In Weibull analysis, Characterastic strength was showed highest value to uncolored LAVATM Ceramic and lowest value to Z-match ceramic, and Weibull modulus(m) of uncolored zirconia was higher than that of colored zirconia. 5. In XRD analysis, all group except Z-match showed high peak of t-ZrO2 but they did not show m-ZrO2. Colored zirconia group showed lower peak of t-ZrO2 than that of uncolored zirconia group.

Comparative analysis of transmittance for different types of commercially available zirconia and lithium disilicate materials

  • Harianawala, Husain Hatim;Kheur, Mohit Gurunath;Apte, Sanjay Krishnaji;Kale, Bharat Bhanudas;Sethi, Tania Sanjeev;Kheur, Supriya Mohit
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권6호
    • /
    • pp.456-461
    • /
    • 2014
  • PURPOSE. Translucency and colour stability are two most important aspects for an aesthetic dental restoration. Glass ceramic restorations are popular amongst clinicians because of their superior aesthetic properties. In the last decade, zirconia has generated tremendous interest due to its favorable mechanical and biological properties. However, zirconia lacks the translucency that lithium disilicate materials possess and therefore has limitations in its use, especially in esthetically demanding situations. There has been a great thrust in research towards developing translucent zirconia materials for dental restorations. The objective of the study was to evaluate and compare the transmittance of a translucent variant of zirconia to lithium disilicate. MATERIALS AND METHODS. Two commercially available zirconia materials (conventional and high translucency) and 2 lithium disilicate materials (conventional and high translucency) with standardized dimensions were fabricated. Transmittance values were measured for all samples followed by a microstructural analysis using a finite element scanning electron microscope. One way analysis of variance combined with a Tukey-post hoc test was used to analyze the data obtained (P=.05). RESULTS. High translucency lithium disilicate showed highest transmittance of all materials studied, followed by conventional lithium disilicate, high translucency zirconia and conventional zirconia. The difference between all groups of materials was statistically significant. The transmittance of the different materials correlated to their microstructure analysis. CONCLUSION. Despite manufacturers' efforts to make zirconia significantly more translucent, the transmittance values of these materials still do not match conventional lithium disilicate. More research is required on zirconia towards making the material more translucent for its potential use as esthetic monolithic restoration.

Choice of resin cement shades for a high-translucency zirconia product to mask dark, discolored or metal substrates

  • Dai, Shiqi;Chen, Chen;Tang, Mo;Chen, Ying;Yang, Lu;He, Feng;Chen, Bingzhuo;Xie, Haifeng
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권5호
    • /
    • pp.286-296
    • /
    • 2019
  • PURPOSE. The aim was to study the masking ability of high-translucency monolithic zirconia and provide guidance in selecting resin luting cements in order to mask discolored substrates. MATERIALS AND METHODS. 160 high-translucency zirconia specimens were divided into 32 groups depending on their thickness and shades. Using five shades of try-in paste, the specimens were luted onto the substrates (Co-Cr, precious-metal, opaque porcelain-sintered Co-Cr, opaque porcelain-sintered precious-metal, and 5M3-shade zirconia). All CIELAB color parameters were measured and statistically analyzed. RESULTS. Zirconia shade and thickness and try-in paste shade affected CIELAB color parameters (P=.000) in different substrates groups, and there were interactions among these factors (P=.000). All five try-in paste shades can be chosen to achieve ${\Delta}E$ values of zirconia with 1.2 - 1.5 mm for masking dark-tooth-like 5M3-shade and zirconia with 1.5 mm for masking precious-metal groups < 2.6. Only suitable try-in paste shades were used, can ${\Delta}E$ values that less than 2.6 be achieved when applied translucent monolithic zirconia with 0.7-1.0 mm for masking dark-tooth-like 5M3-shade and zirconia with 0.7 - 1.2 mm for masking precious-metal groups. CONCLUSION. Choosing suitable resin cement shades is necessary for high-translucency monolithic zirconia to achieve ideal masking ability (${\Delta}E$ < 2.6) on the dark-tooth.

지르코니아 프라이머 종류에 따른 복합레진-지르코니아의 전단결합강도 (Effec of different zirconia primers on shear bond strengths of composite resin to bonded zirconia)

  • 석홍병;김태석;안재석;이정환
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.135-142
    • /
    • 2016
  • Purpose: The aim of this research was to evaluate the influence of different surface treatments on the shear bond strength of zirconia ceramic to composite resin. Methods: Seventy two cylinder-shape (diameter: 5 mm; height: 12 mm) blocks of experimental industrially manufactured Y-TZP ceramic were abraded with $125{\mu}m\;Al_2O_3$ particles and randomly divided into 4 groups. All the materials were categorized as group Gc(control group - composite resin veneering on zirconia surface), Gr - composite resin veneering after surface treatment of Rocatec system (3M ESPE, Seefeld, Germany) group; Gz - composite resin veneering after surface treatment of Zirconia primer (Z-primer, Bisco, U.S.A) group; Gm - composite resin veneering after surface treatment of zirconia primer (Monobond plus, ivoclar vivadent AG, Liechtenstein) group. Two different zirconia primers and Rocatec system were used to zirconia cylinders (n=16) onto the zirconia surface. Zirconia specimens, polished and roughened, were pretreated and composite bilayer cylinders bonded using conventional adhesive techniques. Results: Shear bond strengths were analyzed using single-factor ANOVA(p<0.05). Bond strength values achieved after airbone particle abrasion and zirconia surface pre-treatments(p<0.05). Conclusion: Shear bond strength tests denmonstrated that zirconia primer is a viable method to improved bond strength between zirconia ceramic core and veneering composites.

m-지르코니아와 Yag 졸로부터 지르코니아계 전해질 제조 및 물성 (Preparation and Properties of Zirconia-based Electrolytes from m-Zirconia and Yag Sol)

  • 강건택;임경란;남석우;김창삼;이영수;유한일
    • 한국세라믹학회지
    • /
    • 제38권9호
    • /
    • pp.834-838
    • /
    • 2001
  • 고체 전해질로 많이 사용되는 이트리아로 안정화된 입방정형(cubic) 지르코니아의 기계적 강도를 향상시키기 위하여, 단사형(monoclinic) 지르코니아(m-$ZrO_2$)를 원료로 지르코니아  안정화시키는 이트리아와 지르코니아의 낮은 기계적 강도를 향상시켜 주기 위한 알루미나를 Yag($Y_3Al_5O_{13}$)졸의 형태로 첨가하여, 졸 형태로 첨가된 이트리아와 알루미나가 입방정 지르코니아 소결체의 기계적, 전기적 특성에 미치는 영향을 조사하였다. 17.8 wt% Yag(6.3mol% $Y_2O_3$)가 첨가된 경우 파괴인성은 3.62MPa${\cdot}m^{1/2}$, 파괴강도는 447MPa로 8mol%의 이트리아로 안정화된 지르코니아(TZ8Y)의 1.44MPa${\cdot}m^{1/2}$, 270MPa에 비하여 기계적 특성이 현저히 향상되었으나, 950$^{\circ}$C, 공기분위기에서의 전기전도도는 0.057${\Omega}^{-1}cm^{-1}$로 TZ8Y에 비해 반 정도로 낮아졌으며, 21.6wt% Yag(8.0mol% $Y_2O_3$)가 첨가된 경우에는 파괴인성은 2.93MPa${\cdot}m^{1/2}$, 파괴강도는 388MPa로 TZ8Y에 비하여 향상되었고, 전기전도도는 0.076${\Omega}^{-1}cm^{-1}$을 나타내었다.

  • PDF

단일구조 지르코니아(zirconia) 전부도재관의 표면처리에 따른 전장도재와의 전단결합강도 (Effect of surface treatments on the shear bond strength of full-contour zirconia layered with porcelain)

  • 최병환;김임선
    • 대한치과기공학회지
    • /
    • 제35권2호
    • /
    • pp.121-126
    • /
    • 2013
  • Purpose: The aim of this research was to investigate difference in shear bond strengths of full-contour zirconia layered with porcelain. Methods: Disk-shaped (diameter: 12.0 mm; height: 3.0 mm) zirconia were randomly divided into six groups according to the surface conditioning method to be applied (N=90, n=15 per group): group 1-contol group(ZC); group 2-airborne particle abrasion with $50-{\mu}m\;Al_2O_3(5A)$; group $3-50-{\mu}m\;Al_2O_3$ + liner(5AL), group $4-110-{\mu}m\;Al_2O_3(1A)$; group $5-110-{\mu}m\;Al_2O_3$ + liner(1AL); group 6-liner(LC). On each block, zirconia porcelain was build up according to manufacturer's instructions. All samples were fixed with measuring jigs and shear bond strength were measured with Universal testing machine. Collected data were analyzed using SPSS(Statistical Package for Social Sciences) Win 12.0 statistics program. Results: LC showed the highest value($29.92{\pm}2.55$ MPa) and ZC showed the lowest value($13.22{\pm}1.37$ MPa). Zirconia liner and Alumina oxide groups was significantly higher shear bond strength than control(p<0.05). 5A (without liner $22.18{\pm}2.37$, with liner $22.84{\pm}1.74$ MPa) was higher shear bond strength than $110{\mu}m$ (without liner $20.18{\pm}2.38$, with $20.71{\pm}2.67$). Conclusion: Surface treatments may have advantage in bond strength improvement for full-contour zirconia layered with porcelain.

Comparison of bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and a universal adhesive

  • Lee, Ji-Yeon;Ahn, Jaechan;An, Sang In;Park, Jeong-won
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.7.1-7.7
    • /
    • 2018
  • Objectives: The aim of this study is to compare the shear bond strengths of ceramic brackets bonded to zirconia surfaces using different zirconia primers and universal adhesive. Materials and Methods: Fifty zirconia blocks ($15{\times}15{\times}10mm$, Zpex, Tosoh Corporation) were polished with 1,000 grit sand paper and air-abraded with $50{\mu}m$ $Al_2O_3$ for 10 seconds (40 psi). They were divided into 5 groups: control (CO), Metal/Zirconia primer (MZ, Ivoclar Vivadent), Z-PRIME Plus (ZP, Bisco), Zirconia Liner (ZL, Sun Medical), and Scotchbond Universal adhesive (SU, 3M ESPE). Transbond XT Primer (used for CO, MZ, ZP, and ZL) and Transbond XT Paste was used for bracket bonding (Gemini clear ceramic brackets, 3M Unitek). After 24 hours at $37^{\circ}C$ storage, specimens underwent 2,000 thermocycles, and then, shear bond strengths were measured (1 mm/min). An adhesive remnant index (ARI) score was calculated. The data were analyzed using one-way analysis of variance and the Bonferroni test (p = 0.05). Results: Surface treatment with primers resulted in increased shear bond strength. The SU group showed the highest shear bond strength followed by the ZP, ZL, MZ, and CO groups, in that order. The median ARI scores were as follows: CO = 0, MZ = 0, ZP = 0, ZL = 0, and SU = 3 (p < 0.05). Conclusions: Within this experiment, zirconia primer can increase the shear bond strength of bracket bonding. The highest shear bond strength is observed in SU group, even when no primer is used.

Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro (Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro)

  • 이태희;이하빈;김지환
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.