• Title/Summary/Keyword: m-Health

Search Result 8,195, Processing Time 0.036 seconds

The Effect of Taping on the Range of Motion and Proprioception at the Ankle Joint (테이핑이 발목의 관절가동범위와 고유수용성감각에 미치는 영향)

  • Kim, Chang-In;Kwon, Oh-Yun;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.8 no.3
    • /
    • pp.43-52
    • /
    • 2001
  • This study was designed to determine the effect of ankle taping and short period of walking on the treadmill on the range of motion (ROM) and proprioception at the ankle joint. Twenty healthy male subjects (mean age=24.2 yr) participated in this study. Goniometry and videotape replaying method were used to measure the ankle ROM. Passive sagittal and frontal plane motions were measured. The difference in degree between the stimulus point and the reproduced point was defined as an angular error. The measurements were performed at four different phases: pre-taping (PRT), post-taping immediately (POT), post-5 minute walking with taping (P5M), and post-10 minute walking with taping (P10M). The ankle of dominant limb was taped by a certified athletic trainer using a closed basket weave technique. Participants walked on the treadmill at 2.5 mph. The results showed that the mean of the sagittal plane motion at PRT, POT, P5M, and P10M was 53.0, 30.5, 36.2, and 40.2 degrees, respectively. The frontal plane motion at PRT, POT, P5M, and P10M was 33.6, 13.9, 15.7, and 18.6 degrees, respectively. The angular error at PRT, POT, P5M, and P10M was 5.5, 1.6, 1.8, and 1.9 degrees, respectively. After 10 minutes of walking, the sagittal plane motion and frontal plane motion was increased by 9.7 and 4.7 degrees compared with POT, respectively. The proprioception was significantly improved after the application of ankle taping. Both the restriction of frontal plane motion and proprioception improvement at the ankle joint may contribute to ankle stability during walking.

  • PDF

Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique

  • Kang, Seen-Young;Park, Jung-Hyun;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.354-360
    • /
    • 2018
  • PURPOSE. To compare and analyze trueness and precision of provisional crowns made using stereolithography apparatus and subtractive technology. MATERIALS AND METHODS. Digital impressions were made using a master model and an intraoral scanner and the crowns were designed with CAD software; in total, 22 crowns were produced. After superimposing CAD design data and scan data using a 3D program, quantitative and qualitative data were obtained for analysis of trueness and precision. Statistical analysis was performed using normality test combined with Levene test for equal variance analysis and independent sample t-test. Type 1 error was set at 0.05. RESULTS. Trueness for the outer and inner surfaces of the SLA crown (SLAC) were $49.6{\pm}9.3{\mu}m$ and $22.5{\pm}5.1{\mu}m$, respectively, and those of the subtractive crown (SUBC) were $31.8{\pm}7.5{\mu}m$ and $14.6{\pm}1.2{\mu}m$, respectively. Precision values for the outer and inner surfaces of the SLAC were $18.7{\pm}6.2{\mu}m$ and $26.9{\pm}8.5{\mu}m$, and those of the SUBC were $25.4{\pm}3.1{\mu}m$ and $13.8{\pm}0.6{\mu}m$, respectively. Trueness values for the outer and inner surfaces of the SLAC and SUBC showed statistically significant differences (P<.001). Precision for the inner surface showed significance (P<.03), whereas that for the outer surface showed no significance (P<.58). CONCLUSION. The study demonstrates that provisional crowns produced by subtractive technology are superior to crowns fabricated by stereolithography in terms of accuracy.

Effects of Reactive Oxygen Species on DNA Stability in Humnn Spermatozoa

  • Kang, Hee-Gyoo;Kim, Tai-Jeon;Bae, Hyung-Joon;Moon, Hi-Joo;Kim, Myo-Kyung;Kim, Dong-Hoon;Sungwon-Han;Lee, Ho-Joon;Yang, Hye-Young
    • Biomedical Science Letters
    • /
    • v.7 no.4
    • /
    • pp.181-190
    • /
    • 2001
  • This study was designed to investigate the effects of reactive oxygen species (ROS) on DNA stability in human spermatozoa. To verify human spermatozoa were incubated with xanthine-xanthine oxidase (X 100$\mu$M-XO 50 mlU ~ 400 mIU), $H_2O_2$ (125 $\mu$M ~ 1 mM), sodium nitroprusside (SNP 0.1 $\mu$M ~ 100 $\mu$M) or lymphocyte. Otherwise, spermatozoa were incubated under low $O_2$ (5%) condition. Damage of sperm DNA was analyzed by single cell electrophoresis (Comet assay) and flow cytometry after acridine orange staining. In the presence of ROS, there was increase in DNA damage. The rate of DNA single strand breakage (9.0$\pm$1.0% ~ 46.0$\pm$4.6%) and DNA fragmentation (7.51$\pm$1.0% ~ 29.5$\pm$4.6%) were similar regardless of the kinds of ROS and exposure time. DNA damage in the lower $O_2$ condition (5%) was lower than ambient $O_2$ condition (20%). Taken together, it suggested that sperm DNA might be damaged by ROS. In the presence of ROS, increase in DNA damage and chromatin instability was obvious in spite of short exposure. Although present study reconfirmed that sperm incubation in the low concentration of ROS have the benefit m the induction of capacitation and Ah, the increase in DNA damage by ROS and possible genetic problem should be considered before the human trials.

  • PDF

A STUDY ON THE EFFECTS OF SCATTERING DOSE ON EYES AND THYROID FOR PANORAMAGRAPHY (Focus on TLD and PLD)

  • Jung, Yeun;Dong, Kyung-Rae;Kweon, Dae-Cheol;Dieter, Kevin;Goo, Eun-Hoe;Ahn, Se-Youn;Chung, Jae-Eun
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.1-5
    • /
    • 2010
  • This study concerning the surface dose of eye and thyroid from panoramagraphy used thermoluminescent dosimeter (TLD) and photoluminescent dosimeter (PLD) to take measurements at ten hospitals in the Gwangju metropolitan area. The recommendations from ICRP 60 and ICRP 73 on the allowance standard for eye are 15 mSv and for thyroid is 1 mSv. The left eye TLD and PLD values are 0.19 mSv and 0.24 mSv respectively. The right eye TLD and PLD values are 0.23 mSv and 0.25 mSv respectively. Thyroid TLD and PLD values are 0.08 mSv and 0.25 mSv respectively and did not exceed the allowance standards(p<0.001). Also comparisons are made between TLD and PLD for each organ and PLD has higher dose measurements than TLD. There are statistically significant differences in left eye measurements and thyroid measurements (p<0.01). There is no significant difference in measurements for the right eye (p>0.05). The TLD and PLD measured dose from panoramagraphy instruments on eyes and thyroid from each hospital did not exceed the recommended dose from ICRP 60 for surface dose measurements. However, due to the probability of influence, consideration should be made for all levels of dose.

A Case Report of an Intervention Strategy that Applied an ICF Tool to Improve the Walking Ability of Stroke Patients (뇌졸중 환자의 보행능력 증진을 위한 ICF(International Classification of Functioning, Disability and Health) Tool을 적용한 중재전략의 증례)

  • Bang, Dae-Hyouk;Song, Myung-Soo;Jeong, Wang-Mo;Bong, Soon-Nyung
    • PNF and Movement
    • /
    • v.12 no.2
    • /
    • pp.107-113
    • /
    • 2014
  • Purpose: The objective of this study was to identify functional problems, including walking ability, of patients with strokes using the International Classification of Functioning, Disability, and Health (ICF) and to present a method that could solve functional problems, thereby determining the applicability of the ICF to increase the quality of evaluation and intervention in clinical fields in the future. Methods: Information on stroke patients who were admitted and treated in a hospital was collected. The authors conducted evaluations, interventions, and measurements of the results of the ICF tool in order to improve gait abilities of patients. The subjects were trained using proprioceptive neuromuscular facilitation (PNF) one hour a day and five times a week for four weeks. The result measurement variables were a six-minute gait test, 10 m velocity test, gait instability test, and measurements using the ICF sheet. Results: In the six-minute gait test, gait distance increased by 48 m, from 102 m to 150 m. The gait velocity test result showed an improvement from 0.36m/s to 0.44m/s. The subjects performed a gait instabilitytestwithacupfilledwith50mmwater. In the gait instability test, the amount of water was 38 mm before the intervention; however, it was 50 mm after the intervention. The gait velocity with a cup filled with water improved from 0.25m/s to 0.31m/s. Conclusion: An evaluation and intervention were designed with the ICF tool for stroke patients. Gait abilities improved when the PNF technique was used. The IFC method can be used for evaluation and intervention, and it could help improve gait abilities of stroke patients.

Laccase-Catalyzed Transformation of Chlorophene (Laccase를 이용한 Chlorophene 산화전이에 관한 연구)

  • Kim, Jong-Oh;Kim, Young-Jin
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.63-67
    • /
    • 2007
  • Laccase catalyzes the oxidation and polymerization of aromatic compounds in the presence of molecular oxygen. The oxidative transformation of chlorophene with laccase was conducted in a closed, temperature controlled system. The optimal pH for transformation of chlorophene was proven to be about 5-6. As the temperature rose up to $55^{\circ}C$, the transformation of chlorophene increased. The chlorophene transformation was not enhanced in the presence of soluble polymers. The toxicity of the reaction mixture was increased two times than that of initial reaction mixture after the enzymatic treatment. ABTS has enhanced chlorophene transformation at 0.1 mM and showed negative linear relationship with residual chlorophene by the reaction.

A Study on the Relational Analysis of Human Errors in Railway Accidents

  • Byeoung-Soo YUM;Tae-Yoon KIM;Jong-Uk WON;Chi-Nyon KIM;Won-Mo GAL
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.7 no.1
    • /
    • pp.35-41
    • /
    • 2024
  • Purpose: This study examines the persistent occurrence of railway accidents despite numerous safety devices, highlighting the multifaceted nature of these incidents. Research design, data and methodology: Utilizing the 4M analysis method, the research investigates a decade's worth of accident reported from the Aviation and Railway Accident Investigation Board to identify risk factors and suggest mitigation measures. Results: The analysis reveals that 57% of railway accidents are attributed to human factors, followed by mechanical (28%), environmental (7%), and management (8%) factors. Conclusions: The study underscores the necessity of prioritizing safety and establishing a unified organizational approach to prevent human error accidents. It calls for an alignment of risk perception between headquarters and field operations, advocating for educational and perceptual changes, as well as systematic improvements to achieve safety goals.

Risk Assessment of Aldehydes in Some Residential Indoor Air Included Atopy Patient's Homes (실내 공기 중 일부 알데하이드류에 대한 위해도 평가 - 일부 주택 및 아토피 환자 주택을 대상으로)

  • Moon Kyong Whan;Byeon Sang Hoon;Choi Dal Woong;Lee Eun Il;Oh Eun Ha;Kim Young Whan
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.1 s.88
    • /
    • pp.19-26
    • /
    • 2006
  • This study was undertaken to determine the concentrations of 15 aldehydes in air samples collected from 21 households including 9 atopy patient's homes and to assess the extent of exposure and risk for an individual due to inhalation. Of all the aldehydes identified in both indoor and outdoor environment, formaldehyde and acetaldehyde were the most abundant aldehydes, which were occupied $60\%\;and\;17\%$ of total amount, respectively. The geometric mean concentration of formaldehyde and acetaldehyde in indoor air were $170.5\pm1.9\;{\mu}g/m^3\;and\;47.3\pm1.5\;{\mu}g/m^3$, respectively. There existed a strong correlation between formaldehyde, acetaldehyde and other aldehydes. And the ratio of indoor and outdoor concentrations (I/O) exceeded 1.0 for almost every measured aldehydes except m-tolualdehyde... No associations were found between the level of aldehydes and either housing characteristics or living habits in most of the samples with only a few exception. And the concentrations of all aldehydes indoor air between atopy patient's homes and control homes were not significant(p>0.05). Formaldehyde and acetaldehyde exposures and risks were estimated by using the inhalation unit risk, mean concentrations and the 95th percentiles, and which were $2.6\times10^{-3}\;and\;1.1\times10^{-4}$, respectively. The mean and the 95th percentile risk estimates were 25 times higher for formaldehyde than for acetaldehyde in homes.

A Study on the Floor Plan Type and the Spatial Composition of Standard Mental Health Centers in Seoul (서울시 기초정신건강증진센터의 평면유형 및 소요공간구성에 관한 연구)

  • Lim, Yen Jung;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.1
    • /
    • pp.45-55
    • /
    • 2014
  • Purpose: The purpose of this study is to provide data on the basis for architectural planning of floor plan type and spatial composition by analysing standard mental health centers in Seoul. Methods: Data were collected through literature research, field surveys, and expert interviews to 22 standard mental health centers in Seoul. Results: The results of this study could be summarized as follows; Firstly, Mental Health Center is divided into five types according to the location. Location types of mental health center were 'Director type', 'Health center connection type', 'Public facilities connection type', 'Complex center connection type' and 'Commercial Facilities connection type'. Secondly, Depending on the type of management a mental health center is divided into two types. Types are 'Complex type' and 'Independent type'. Average area of 'Complex type' is $192.99m^2$ and 'Independent type' is $266.87m^2$. This difference affects the various spaces. Implications: It is necessary to give and architectural suggestion of mental health center in response to the proposal of the system.