• 제목/요약/키워드: m-Health

검색결과 8,195건 처리시간 0.035초

IN VITRO AND IN VIVO EVALUATION OF THE GENOTOXIC EFFECT OF 2-BROMOPROPANE BY THE ALKALINE SINGLE-CELL GEL ELECTROPHORESIS(COMET) ASSAY

  • Kim, Soo-Jin;Yu, Il-Je;Lee, Yong-Mook;Chung, Ho-Keun;Maeng, Seung-Hee
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2002년도 Molecular and Cellular Response to Toxic Substances
    • /
    • pp.146-146
    • /
    • 2002
  • The alkaline single cell gel electrophoresis (comet) assay was used to clarify in vitro and in vivo genotoxicity of 2-bromopropane (2-BP). For in vitro studies, fresh medium containing 2-BP (2.50, 1.00, 0.50, 0.25, 0.10, 0.05, 0.01 mM, and vehicle control) were added in human lymphocytes.(omitted)

  • PDF

황사시와 비황사시 대기 입자상 탄소성분의 농도 특성 (Concentration Characteristics of Elemental and Organic Carbons During Asian Dust Episode and Non-Episode)

  • 황경철;조기철;신은상
    • 환경위생공학
    • /
    • 제24권4호
    • /
    • pp.102-111
    • /
    • 2009
  • In this study, Particulate carbon were determined from 1990 to 1995. The annual variation were investigated. The sampling was carried out using high volume air sampler. Average concentrations of EC and OC during the yellow sand event were $25.70{\mu}g/m^3$ and $13.91{\mu}g/m^3$, respectively, $22.10{\mu}g/m^3$ and $10.33{\mu}g/m^3$ during the non-yellow sand event. TC concentration of TSP were 10.7% during the yellow sand event and 20.6% during the non-yellow sand event. Average concentration rate of EC and OC of TC were 64.9% and 35.1%, respectively during the yellow sand event, 67.6% and 32.4% during the non-yellow sand event.

STUDIES ON THE HEPATOTOXICITY PRODUCED BY INTERACTION OF SEVERAL DRUGS CONTAINING AMINO GROUPS AND NITRITE

  • Moon, Hwa-Hwey;Kim, Pu-Young;Park, Han-Soo;Choi, Cheol-Hee
    • Toxicological Research
    • /
    • 제3권2호
    • /
    • pp.81-88
    • /
    • 1987
  • Hepatotoxicity study of the nitrosamine produced by interaction between drugs containing amino groups and soduim nitrite was conducted. In the in vitro study, interaction of 32mM Promethazine HCL or Oxomemazine HCL with 200mM Sodium nitrite produced N-nitroso dimetylamine (NDMA) at 0.4% or 0.03%, respectively. When sodium nitrite was administered with Promethazine HCL or Oxomemazine HCL, trace of NDMA was detected from the gastric contents. After three days of consecutive administration of sodium nitrite with Promethazine HCL or Oxomemazine HCL, the levels of GOT, GPT and SDH in the serum of treated groups were significant higher than that of control group.

  • PDF

중량당 섬유수가 다른 국내산 석면이 폐 기능과 폐 조직에 미치는 영향 평가 (Effect of Fiber Number Per Mass Concentration in Korean Produced Asbestos on Lung Function and Pathology)

  • 정용현;한정희;강민구;김종규;양정선
    • 한국산업보건학회지
    • /
    • 제22권4호
    • /
    • pp.301-308
    • /
    • 2012
  • Objectives: To evaluate the pulmonary toxicity of 2 Korea asbestos(chrysotile, anthophyllite), Sprague-Dawely rats were exposed to 2 mg domestic asbestos by intratracheal instillation(IT). Methods: Lung function of rats was analyzed by pressure transducer(MAX1320, Buxco Electronics, USA). The effects of 2 mg asbestos(chrysotile ; $8,814,244{\times}10^{6}$ fibers/mg, average diameter 0.08 ${\mu}m$, average length 4.39 ${\mu}m$, anthophyllite ; $5,182{\times}10^{6}$ fibers/mg, average diameter 0.95 ${\mu}m$, average length 7.29 ${\mu}m$) on pulmonary function and pathological changes were evaluated at after a single IT. Lung function and histopathological evaluation were assessed in 5 animals from each group at each time point. Results: Due to differences in fiber numbers, chrysotile induce marked lung pathology and lung function change than anthophyllite at the same mass dose. Chrysotile showed notable thickening of interstitial areas surrounding the alveolar ducts and terminal bronchioles. Conclusions: On a mass dose basis, chrysotile that have 1,700 times numbers of fibers per unit weight than anthophyllite produced a greater persistent lung injury than anthophllite for at least 4 weeks after exposure.

국내산 백석면과 안소필라이트의 물리화학적 특성과 호흡기계 내 변화 연구 (Physicochemical Property Changes on Respiratory System of Rats After Intratracheal Instillation Exposure to Korea Chrysotile and Anthophyllite)

  • 정용현;한정희;강민구;김종규;양정선
    • 한국산업보건학회지
    • /
    • 제22권3호
    • /
    • pp.224-234
    • /
    • 2012
  • Objectives: To assess the hazard of Korea chrysotile and anthophylite, fibers were analyzed for their physicochemical properties by transmission electron microscope equipped with energy dispersive X-ray spectrometer (TEM-EDS). Methods: To evaluate the biopersistence of 2 domestic asbestos, Sprague-Dawely rats were exposed to 2 mg asbestos by intratracheal instillation. Each asbestos (chrysotile ; $8,814,244{\times}10^6$ fibers/mg, average size $0.08{\mu}m{\times}4.39{\mu}m$, anthophyllite ; $5,182{\times}10^6$ fibers/mg, average size $0.95{\mu}m{\times}7.29{\mu}m$) were evaluated after a single intratracheal instillation. At times from 1 week to 4 weeks after exposure, the numbers of asbestos fivers in the bronchoalveolar lavage fluid and in the lung were calculated. Results: Anthophyllite fivers continuously have retained for 4 weeks but chrysotile fivers were rarely found at 4 weeks after exposure in the bronchoalveolar lavage fluid. Chrysotile fivers at 4 weeks after treatment were not observed but anthophyllite was easily observed in the lung with phase contrast microscopy. According to electron microscopic observation of asbestos in the lung, within 1 week after the administration of chrysotile fivers were decreased rapidly but anthophyllite fivers were very little change for 4 weeks. When chrysotile fivers have been lost Fe in 1 week, there were no significant changes in anthophyllite fivers in the lung. Conclusions: These findings indicate that after a long time exposure to chrysotile, asbestos bodies can not be found in the bronchoalveolar lavage fluid.

Infectious Status on Monogenetic Trematodes of Sebastes spp. (Family : Scorpaenidae) Including Microcotyle sebastis, Megalocotyle trituba an Trochopus australis in Newport Fish Market

  • Chun, Kae-Shik
    • 한국환경보건학회지
    • /
    • 제29권4호
    • /
    • pp.55-57
    • /
    • 2003
  • Nine (34.6%) of the 26 rockfishes taken from Newport fish market, Oregon in July 2003 had a total of 135 monogenetic trematodes attached the gills. Microcotyle sebastis, Megalocotyle trituba and Trochopus australis were encountered, occurring in rockfishes examined. In the monogenetic trematodes in Sebastes spp, the prevalence were found to be between 30.8 and 40.0%. Prevalence of M. sebastis was 37.5%, 40.0% on M. trituba and 30.8% on T. australis. Nine of Sebastes spp. were infected with one or two species of monogenetic trematodes. Intensities of infection for M. sebastis, M. trituba and T. australis were recorded as 2.0 (2-12), 22.0 (48-62) and 1.0 (1-3), respectively. It may be that the intensities of infection for M. trituba should be high, and M. sebastis and T. australis little low.

Effects of Natural Extracts on COX-1 and COX-2 mRNA Expression on UVB-induced Skin Inflammation in C57BL/6 Mouse

  • Ahn, Ryoung-Me
    • 한국환경보건학회지
    • /
    • 제32권6호
    • /
    • pp.566-570
    • /
    • 2006
  • Exposure to ultraviolet B(UVB) radiation causes skin inflammation such as pigmentation and the induction of cyclooxygenase-2(COX-2) gene expression. In this study, we investigated the effect of natural extracts from Tea, EGb 761 and Korean red ginseng(KRG), on the pigmentation and expression of COX-1 and COX-2 mRNA in UVB-irradiated C57BL/6 mice. Before UVB irradiation, the skin color was significantly showed the lightening effect by topical application of natural compounds (p<.05). In the case of UVB irradiated mice, we observed a decrease in pigmentation by compounds (p<.05). In irradiated skin, COX-1 mRNA expression is not changed following UVB irradiation, but COX-2 gene increases. Also, natural compounds lowered mRNA levels of COX-2. Therefore, these results suggest that COX-2 mRNA increases by UVB irradiation. Also, Tea, EGb 761 and KRG as a topical application may inhibit skin pigmentation and modulate COX-2 mRNA level.

지게차 운전원의 블랙카본(black carbon, BC) 노출에 영향을 미치는 직업적 요인 (Occupational Factors Influencing the Forklift Operators' Exposure to Black Carbon)

  • 이혜민;이승희;류승훈;박지훈;박동욱
    • 한국산업보건학회지
    • /
    • 제27권4호
    • /
    • pp.313-323
    • /
    • 2017
  • Objectives: This study aimed to assess exposure to black carbon(BC) among forklift operators and to identify environmental and occupational factors influencing their BC exposure. Methods: We studied a total of 23 forklift operators from six workplaces manufacturing paper boxes. A daily BC exposure assessment was conducted during working hours from January to April 2017. A micro-aethalometer was used to monitor daily BC exposure, and information on work activities was also obtained through a time-activity diary(TAD) and interviews. BC exposure records were classified into four categories influencing BC exposure level: working environment, workplace, forklift operation, and job characteristics. Analysis of variance(ANOVA) was used to compare average BC exposure levels among the four categories and the relationships between potential factors and BC exposure were analyzed using a multiple linear regression model. Results: The operators' daily exposure was $12.9{\mu}g/m^3$(N=9,148, $GM=7.5{\mu}g/m^3$) with a range: $0.001-811.4{\mu}g/m^3$. The operators were exposed to significantly higher levels when they operate a forklift in a room ${\leq}20,000m^3$($AM=12.3{\mu}g/m^3$), in indoor workplaces($AM=16.3{\mu}g/m^3$), when they operate a forklift manufactured before 2006 ($AM=13.2{\mu}g/m^3$), a forklift with a loading limit of four-tons($AM=27.1{\mu}g/m^3$), with a roll and bale type clamp($AM=17.1{\mu}g/m^3$), and with no particulate filter($AM=15.7{\mu}g/m^3$). Conclusions: Occupational factors including temperature, smoking, season, daytime, room volume($m^3$), location of operating, and manufacturing era and model of forklift influenced the BC exposure of forklift operators. The results of this study can be used to minimize the BC exposure of forklift operators.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • 한국환경과학회지
    • /
    • 제18권5호
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

흡입챔버 내 didecyldimethylammonium chloride(DDAC) 에어로졸의 분석 (Analysis of didecydimethylammonium chloride (DDAC) aerosol in inhalation chamber)

  • 양정선;최성봉;박상용;이성배
    • 분석과학
    • /
    • 제25권5호
    • /
    • pp.307-312
    • /
    • 2012
  • 4급 암모늄 계열의 대표적인 살균제인 didecyldimethylammonium chloride(DDAC)는 흡입 경로에 의해 폐 섬유화 등의 폐질환을 일으킬 가능성이 높은 물질로, 흡입독성시험을 위하여 전신 흡입노출 챔버 내에 에어로졸 형태로 분무된 DDAC의 포집 및 분석방법을 검토하였다. DDAC의 포집 회수율은 아세토니트릴을 사용하여 탈착한 XAD 흡착제의 회수율이 87.8%로 실리카겔의 경우보다 우수한 것으로 나타났다. 이온크로마토그라프-전기전도도 검출기로 분석한 DDAC의 검출한계(MDL, method detection limit)는 0.18 ${\mu}g/mL$이었으며, 정량한계(LOQ, limit of quantitation)는 0.54 ${\mu}g/mL$였다. 공기 포집량 240 L를 기준으로 챔버 내 공기 중 농도로 환산하면 MDL이 2.97 ${\mu}g/m^3$, LOQ가 8.92 ${\mu}g/m^3$로, 챔버 내 발생 농도인 70~900 ${\mu}g/m^3$ 농도 수준의 모니터링에 적절하였다. 분석의 재현성은 0~20 ${\mu}g/mL$ 농도범위에서 상대오차 7.8% 내외였으며 시료 분석에 소요되는 시간은 5분 이내였다. 따라서 XAD를 사용한 DDAC의 포집 및 이온크로마토그라피를 이용한 분석방법은 실험동물을 사용한 전신 흡입노출 챔버 내 DDAC 농도의 신속하고 편리한 모니터링에 적절한 것으로 나타났다.