• Title/Summary/Keyword: lung volume

Search Result 581, Processing Time 0.023 seconds

Effects of Pilocarpine on Pressure-Volume Curve of the Excised Rabbit Lung and Pulmonary Surfactant (Pilocarpine투여(投與) 가토폐장(家免肺臟)의 압력(壓力)-용적곡선(容積曲線) 및 폐포표면활성물질(肺胞表面活性物質)에 관(關)하여)

  • Lee, Seung-Jung;Chae, Soo-Hi;Lee, Suck-Kang
    • The Korean Journal of Physiology
    • /
    • v.8 no.2
    • /
    • pp.49-53
    • /
    • 1974
  • A single dose of pilocarpine was subcutaneously injected into the rabbit in order to clarify the effects of cholinergic activities on the secretion of the pulmonary surfactant. The animal was sacrificed four hours after the injection, and the pressure-volume curve of the excised lung was obtained. The surfactant activities of the lung washings were also measured, and a comparison was made with the normal. The pressure-volume curve of the excised lung by the injection and ejection of air formed a loop (hysteresis) and the mean intra-alveolar pressure at 35 ml of air was 220 $mmH_20$ in the normal. The mean deflation curve of the pilocarpine treated rabbit lungs was shifted to the left compared with the normal. The surfactant activities were slightly increased than the normal. The above results suggest that pilocarpine stimulates the secretion of the pulmonary surfactant from the Type II alveolar epithelial cell.

  • PDF

The Lung Volumes of Korean Females (한국여성의 연령별 정상폐용적 측정)

  • Kim, J.H.;Lee, D.S.;Lee, S.J.;Choi, D.K.
    • The Korean Journal of Physiology
    • /
    • v.1 no.1
    • /
    • pp.77-82
    • /
    • 1967
  • The normal lung volumes were determined and subdivided under sitting position in 48 middle school girls, 49 high school girls and 44 house wives. All subjects were free of pulmonary and vascular diseases. The vital capacity was measured by Mckessons spirometer and the residual volume was determined by Rahn's three breathing method. 1. The lung volumes (BTPS) of middle school girls determined were: $RV\;0.59{\pm}0.11l\;FRC\;1.45{\pm}2.22l\;VC\;2.68{\pm}0.29l$ 2. The lung volumes (BTPS) of high school girls determined were: $RV\;0.83{\pm}0.19l\;FRC\;1.9{\pm}0.25l\;VC\;3.15{\pm}0.24l$ 3. The lung volumes (BTPS) of house wives determind were: $RV\;0.95{\pm}0.61{\ell}\;FRC\;2.1{\pm}0.25{\ell}\;VC\;3.06{\pm}0.29l$ 4. The calculated residual ratio $(RV/TLC{\times}100)$ were: $17.7{\pm}2.57%$ in middle school girls and $20.6{\pm}3.65%$ in high school girls and $24.0{\pm}2.31%$ in house wives 5. The functional residual ratio $(FRC/TLC{\times}100)$ were: $43.7{\pm}5.98%$ in middle school girls and $48.8{\pm}4.41%4 in high school girls and $52.6{\pm}5.38%$ in house wives. 6. The correlation coefficients between vital capacity and total lung capacity were r=0.96 in middle school girls and r=0.986 in high school girls and r=0.856 in house wives. 7. The regression equations were obtained follows: $TLC(l) =1.105{\times}VC+0.304$ (in middle school girls) $TLC(l) =1.551{\times}VC-0.902$ (in high school girls) $TLC(l) =0.999{\times}VC+0.954$ (in house wives)

  • PDF

Elevated Serum Neutrophil to Lymphocyte and Platelet to Lymphocyte Ratios Could be Useful in Lung Cancer Diagnosis

  • Kemal, Yasemin;Yucel, Idris;Ekiz, Kubilay;Demirag, Guzin;Yilmaz, Bahiddin;Teker, Fatih;Ozdemir, Meltem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.6
    • /
    • pp.2651-2654
    • /
    • 2014
  • Background: Lung cancer (LC) is still the primary cause of cancer deaths worldwide, and late diagnosis is a major obstacle to improving lung cancer outcomes. Recently, elevated preoperative or pretreatment neutrophil to lymphocyte ratio (NLR), platelet to lymphocyte ratio (PLR) and mean platelet volume (MPV) detected in peripheral blood were identified as independent prognostic factors associated with poor survival with various cancers, including colon cancer, esophageal cancer, gastric cancer and breast cancer. Objective: The aim of this study was to examine whether MPV, NLR and PLR could be useful inflammatory markers to differentiate lung cancer patients from healthy controls. An investigation was also made of the relationship between these markers and other prognostic factors and histopathological subgroups. Materials and Methods: Retrospectively eighty-one lung cancer patients and 81 age-sexes matched healthy subjects included into the study. Patients with hypertension, hematological and renal disease, heart failure, chronic infection, hepatic disorder and other cancer were excluded from the study. The preoperative or pretreatment blood count data was obtained from the recorded computerized database. Results: NLR and PLR values were significantly higher in the LC patients compared to the healthy subjects.( NLR: 4.42 vs 2.45 p=0.001, PLR: 245.1 vs 148.2 p=0.002) MPV values were similar in both groups (7.7 vs 7.8). No statistically significant relationship was determined between these markers (MPV, NLR and PLR) and histopathological subgroups and TNM stages. Conclusions: NLR and PLR can be useful biomarkers in LC patients before treatment. Larger prospective studies are required to confirm these findings.

The Studies on the Development of Radiation Pneumonitis and Its Related Factors (방사선폐렴의 발생과 촉진요인에 관한 고찰)

  • Suh, Hyun-Suk;Rhee, Chung-Sik
    • Radiation Oncology Journal
    • /
    • v.5 no.2
    • /
    • pp.119-129
    • /
    • 1987
  • With the introduction of X-rays of higher energy that have higher penetrability, it has become possible to treat the deep-seated tumor with increased local control rate. But at the same time it has incrased the damage to the deep seated organs, especially to the lung which is known to be the less radiotolerable tissue in the body. This study analyses the 66 patients who were exposed to the irradiation of the lung, and examines the development of radiation pneumonitis and its related factors. The results of the study are summarized as follows: 1, The 66 patients were consisted of 40 cases of lung cancer, 15 cases of breast cancer and 11 cases of mediastinal tumors. There were 37 males and 29 females with the male to female ratio 1.3: 1. A male to female ratio in the lung cancer was 3: 1. 2. Among 66 patients, 26 patients $(39\%)$ developed the radiographical changes of acute radiation pneumonitis and 13 out of 26 patients $(50\%)$ showed the clinical features of acute radiation pneumonitis. 3. The onest of acute radiation pneumonitis ranged from 10 days to 6 months after the completion of radiotherapy. 4. There was a statistically significant close relationship between the development of radiation pneumonitis and the radiation dose. 5. As the irradiated lung volume increased, the development of radiation pneumonitis increased. But the statistical significance was not strong. 6. The increased incidence of radiation pneumonitis was observed when the chemotherapy was given before or concomittantly with radiotherapy. 7 There was no significant correlation between the development of radiation pneumonitis and the age, smoking and the presence of underlying lung disease.

  • PDF

Dosimetric Analysis of Lung Stereotactic Body Radiotherapy Using Halcyon Linear Accelerator

  • Shinhaeng Cho;Ick Joon Cho;Yong Hyub Kim;Jea-Uk Jeong;Mee Sun Yoon;Taek-Keun Nam;Sung-Ja Ahn;Ju-Young Song
    • Progress in Medical Physics
    • /
    • v.34 no.4
    • /
    • pp.48-54
    • /
    • 2023
  • Purpose: In this study, the dosimetric characteristics of lung stereotactic body radiotherapy (SBRT) plans using the new Halcyon system were analyzed to assess its suitability. Methods: We compared the key dosimetric parameters calculated for the Halcyon SBRT plans with those of a conventional C-arm linear accelerator (LINAC) equipped with a high-definition multileaf collimator (HD-MLC)-Trilogy Tx. A total of 10 patients with non-small-cell lung cancer were selected, and all SBRT plans were generated using the RapidArc technique. Results: Trilogy Tx exhibited significant superiority over Halcyon in terms of target dose coverage (conformity index, homogeneity index, D0.1 cc, and D95%) and dose spillage (gradient). Trilogy Tx was more efficient than Halcyon in the lung SBRT beam delivery process in terms of the total number of monitor units, modulation factor, and beam-on time. However, it was feasible to achieve a dose distribution that met SBRT plan requirements using Halcyon, with no significant differences in satisfying organs at risk dose constraints between both plans. Conclusions: Results confirm that Halcyon is a viable alternative for performing lung SBRT in the absence of a LINAC equipped with HD-MLC. However, extra consideration should be taken in determining whether to use Halcyon when the planning target volume setting is enormous, as in the case of significant tumor motions.

The efficacy of continuous positive airway pressure (CPAP) for patient with left breast cancer (좌측 유방암 방사선치료에서 CPAP(Continuous Positive Airway Pressure)의 유용성 평가)

  • Jung, Il Hun;Ha, Jin Sook;Chang, Won Suk;Jeon, Mi Jin;Kim, Sei Joon;Jung, Jin Wook;Park, Byul Nim;Shin, Dong Bong;Lee, Ik Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.43-49
    • /
    • 2019
  • Purpose: This study examined changes in the position of the heat and lungs depending on the patient's breathing method during left breast cancer radiotherapy and used treatment plans to compare the resulting radiation dose. Materials and methods: The participants consisted of 10 patients with left breast cancer. A CT simulator(SIMENS SOMATOM AS, Germany) was used to obtain images when using three different breathing methods: free breathing(FB), deep inspiration breath hold(DIBH with Abches, DIBH), inspiration breath hold(IBH with CPAP, CPAP). A Ray Station(5.0.2.35, Sweden) was used for treatment planning, the treatment method was volumetric modulated arc therapy (VMAT) with one partial arc of the same angle, and the prescribed dose to the planning target volume (PTV) was a total dose of 50Gy(2Gy/day). In treatment plan analysis, the 95% dose (D95) to the PTV, the conformity index(CI), and the homogeneity index (HI) were compared. The lungs, heart, and left anterior descending artery (LAD) were selected as the organs at risk(OARs). Results: The mean volume of the ipsilateral lung for FB, DIBH, and CPAP was 1245.58±301.31㎤, 1790.09±362.43 ㎤, 1775.44±476.71 ㎤. The mean D95 for the PTV was 46.67±1.89Gy, 46.85±1.72Gy, 46.97±23.4Gy, and the mean CI and HI were 0.95±0.02, 0.96±0.02, 0.95±0.02 and 0.91±0.01, 0.90±0.01, 0.92±0.02. The V20 of Whole Lung was 10.74±4.50%, 8.29±3.14%, 9.12±3.29% and The V20 of the ipsilateral lung was 20.45±8.65%, 17.18±7.04%, 18.85±7.85%, the Dmean of the heart was 7.82±1.27Gy, 6.10±1.27Gy, 5.67±1.56Gy, and the Dmax of the LAD was 20.41±7.56Gy, 14.88±3.57Gy, 14.96±2.81Gy. The distance from the thoracic wall to the LAD was measured to be 11.33±4.70mm, 22.40±6.01mm, 20.14±6.23mm. Conclusion: During left breast cancer radiotherapy, the lung volume was 46.24% larger for DIBH than for FB, and 43.11% larger for CPAP than FB. The larger lung volume increases the distance between the thoracic wall and the heart. In this way, the LAD, which is one of the nearby OARs, can be more effectively protected while still satisfying the treatment plan. The lung volume was largest for DIBH, and the distance between the LAD and thoracic wall was also the greatest. However, when performing treatment with DIBH, the intra-fraction error cannot be ignored. Moreover, communication between the patient and the radiotherapist is also an important factor in DIBH treatment. When communication is problematic, or if the patient has difficulty holding their breath, we believe that CPAP could be used as an alternative to DIBH. In order to verify the clinical efficacy of CPAP, it will be necessary to perform long-term follow-up of a greater number of patients.

Feasibility and Efficacy of Adaptive Intensity Modulated Radiotherapy Planning according to Tumor Volume Change in Early Stage Non-small Cell Lung Cancer with Stereotactic Body Radiotherapy (폐암의 정위적체부방사선치료에서 육안적종양체적 변화에 따른 적응방사선치료의 효용성 및 가능성 연구)

  • Park, Jae Won;Kang, Min Kyu;Yea, Ji Woon
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.79-86
    • /
    • 2015
  • The purpose of this study is to evaluate efficacy and feasibility of adaptive radiotherapy according to tumor volume change (TVC) in early stage non-small cell lung cancer (NSCLC) using stereotactic body radiotherapy (SBRT). Twenty-two lesions previously treated with SBRT were selected. SBRT was usually performed with a total dose of 48 Gy or 60 Gy in four fractions with an interval of three to four days between treatments. For evaluation of TVC, gross tumor volume (GTV) was contoured on each cone-beam computed tomography (CBCT) image used for image guidance. Intensity modulated radiotherapy (IMRT) planning was performed in the first CBCT (CBCT1) using a baseline plan. For ART planning (ART), re-optimization was performed at $2^{nd}$, $3^{rd}$, and $4^{th}$ CBCTs (CBCT2, CBCT3, and CBCT4) using the same angle and constraint used for the baseline plan. The ART plan was compared with the non-ART plan, which generated copying of the baseline plan to other CBCTs. Average GTV volume was 10.7 cc. Average TVC was -1.5%, 7.3%, and -25.1% in CBCT2, CBCT3, and CBCT4 and the TVC after CBCT3 was significant (p<0.05). However, the nine lesions were increased GTV in CBCT2. In the ART plan, $V_{20\;Gy}$, $D_{1500\;cc}$, and $D_{1000\;cc}$ of lung were significantly decreased (p<0.05), and $V_{30\;Gy}$ and $V_{32\;Gy}$ of the chest wall were also decreased (p<0.05). While D min of planning target volume (PTV) decreased by 8.3% in the non-ART plan of CBCT2 compared with the baseline plan in lesions with increased tumor size (p=0.021), PTV coverage was not compromised in the ART plan. Based on this result, use of the ART plan may improve target coverage and OAR saving. Thus ART using CBCT should be considered in early stage NSCLC with SBRT.

Comparison of Anisotropic Analytic Algorithm Plan and Acuros XB Plan for Lung Stereotactic Ablative Radiotherapy Using Flattening Filter-Free Beams (비편평화여과기 빔을 이용한 폐 정위절제방사선치료를 위한 AAA와 Acuros XB 계산 알고리즘의 치료계획 비교)

  • Chung, Jin-Beom;Eom, Keun-Yong;Kim, In-Ah;Kim, Jae-Sung;Lee, Jeong-Woo;Hong, Semie;Kim, Yon-Lae;Park, Byung-Moon;Kang, Sang-Won;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.210-217
    • /
    • 2014
  • This study investigated the dosimetric effects of different dose calculation algorithm for lung stereotactic ablative radiotherapy (SABR) using flattening filter-free (FFF) beams. A total of 10 patients with lung cancer who were treated with SABR were evaluated. All treatment plans were created using an Acuros XB (AXB) of an Eclipse treatment planning system. An additional plans for comparison of different alagorithm recalcuated with anisotropic analytic algorithm (AAA) algorithm. To address both algorithms, the cumulative dose-volume histogram (DVH) was analyzed for the planning target volume (PTV) and organs at risk (OARs). Technical parameters, such as the computation times and total monitor units (MUs), were also evaluated. A comparison analysis of DVHs from these plans revealed the PTV for AXB estimated a higher maximum dose (5.2%) and lower minimum dose (4.2%) than that of the AAA. The highest dose difference observed 7.06% for the PTV $V_{105%}$. The maximum dose to the lung was also slightly larger in the AXB plans. The percentate volumes of the ipsilateral lung ($V_5$, $V_{10}$, $V_{20}$) receiving 5, 10, and 20 Gy were also larger in AXB plans than for AAA plans. However, these parameters were comparable between both AAA and AXB plans for the contralateral lung. The differences of the maximum dose for the spinal cord and heart were also small. The computation time of AXB plans was 13.7% shorter than that of AAA plans. The average MUs were 3.47% larger for AXB plans than for AAA plans. The results of this study suggest that AXB algorithm can provide advantages such as accurate dose calculations and reduced computation time in lung SABR plan using FFF beams, especially for volumetric modulated arc therapy technique.

Optimal dose and volume for postoperative radiotherapy in brain oligometastases from lung cancer: a retrospective study

  • Chung, Seung Yeun;Chang, Jong Hee;Kim, Hye Ryun;Cho, Byoung Chul;Lee, Chang Geol;Suh, Chang-Ok
    • Radiation Oncology Journal
    • /
    • v.35 no.2
    • /
    • pp.153-162
    • /
    • 2017
  • Purpose: To evaluate intracranial control after surgical resection according to the adjuvant treatment received in order to assess the optimal radiotherapy (RT) dose and volume. Materials and Methods: Between 2003 and 2015, a total of 53 patients with brain oligometastases from non-small cell lung cancer (NSCLC) underwent metastasectomy. The patients were divided into three groups according to the adjuvant treatment received: whole brain radiotherapy (WBRT) ${\pm}$ boost (WBRT ${\pm}$ boost group, n = 26), local RT/Gamma Knife surgery (local RT group, n = 14), and the observation group (n = 13). The most commonly used dose schedule was WBRT (25 Gy in 10 fractions, equivalent dose in 2 Gy fractions [EQD2] 26.04 Gy) with tumor bed boost (15 Gy in 5 fractions, EQD2 16.25 Gy). Results: The WBRT ${\pm}$ boost group showed the lowest 1-year intracranial recurrence rate of 30.4%, followed by the local RT and observation groups, at 66.7%, and 76.9%, respectively (p = 0.006). In the WBRT ${\pm}$ boost group, there was no significant increase in the 1-year new site recurrence rate of patients receiving a lower dose of WBRT (EQD2) <27 Gy compared to that in patients receiving a higher WBRT dose (p = 0.553). The 1-year initial tumor site recurrence rate was lower in patients receiving tumor bed dose (EQD2) of ${\geq}42.3Gy$ compared to those receiving <42.3 Gy, although the difference was not significant (p = 0.347). Conclusions: Adding WBRT after resection of brain oligometastases from NSCLC seems to enhance intracranial control. Furthermore, combining lower-dose WBRT with a tumor bed boost may be an attractive option.

Changes in Physiological Responses by the Pressure of Non-Elastic Corset (비신축성 코르셋의 의복압으로 인한 생리적 반응의 변화)

  • Na, Young-Joo;Kim, Yang-Hee
    • Fashion & Textile Research Journal
    • /
    • v.13 no.6
    • /
    • pp.943-951
    • /
    • 2011
  • The purpose of this study is to analyze the physiological effects of non-elastic corset on women's health and pain through measuring the clothing pressure, subjective pressure sensation, blood velocity and metabolism. 5 women in their twenties were picked as our subjects, their average size being 85cm at bust girth, 69 cm at waist girth. With the subjects each wearing a corset, we are testing in artificial environment with a treadmill according to the planned exercise procedures. The average pressure of the corset is 0.938 kPa (maximum 3.006 kPa at 45 degree front bowing), which is 10.2 times higher than the control group, averaging from 9.3 times higher at resting, 11.4 times at walking, 11.1 times at running. The effect of corset pressure on the physiological responses of the body is increased more when exercise than when resting. Clothing pressure increased in the order of the postures: sitting > standing with 45 degree bowing > standing. They experienced a high level of tighten discomfort of 5.6 in the scale of 1.0 to 7.0 due to the high pressure of the corset when resting, after intense exercise the level increased to 6.0, while without corset the level increased 1.7 to 2.2. With corset on, the blood circulation did not increase even though when the body exercised and blood flow became unbalanced making great gaps between both at the right and left finger tips. Perspiration of chest and back decreased 37.3% when wearing corset; 27.5% at resting, 56.7% at walking, 25.8% at running, and 39.0% at recovery. With corset on oxygen consume and metabolism increased 9.0%, 7.9%, respectively, which means the corset makes the body uncomfortable. Lung volume exchange VE decreased almost 4.1~7.3% with corset on and $VCO_2/VO_2$, RER and total volume in lung, VT also decreased too, which means the digestion of stomach and lung function are inhibited due to the high corset pressure.