• Title/Summary/Keyword: lumbar spinal fusion

Search Result 135, Processing Time 0.027 seconds

Survival Rates and Risk Factors for Cephalad and L5-S1 Adjacent Segment Degeneration after L5 Floating Lumbar Fusion : A Minimum 2-Year Follow-Up

  • Lee, Young-Seok;Kim, Young-Baeg;Park, Seung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.2
    • /
    • pp.108-113
    • /
    • 2015
  • Objective : Although the L5-S1 has distinct structural features in comparison with other lumbar spine segments, not much is known about adjacent segment degeneration (ASD) at the L5-S1 segment. The aim of study was to compare the incidence and character of ASD of the cephalad and L5-S1 segments after L5 floating lumbar fusion. Methods : From 2005 to 2010, 115 patients who underwent L5 floating lumber fusion were investigated. The mean follow-up period was 46.1 months. The incidence of radiological and clinical ASD of the cephalad and the L5-S1 segments was compared using survival analysis. Risk factors affecting ASD were analyzed using a log rank test and the Cox proportional hazard model. Results : Radiological ASD of the L5-S1 segment had a statistically significant higher survival rate than that of the cephalad segment (p=0.001). However, clinical ASD of the L5-S1 segment was significantly lower survival rates than that of the cephalad segment (p=0.038). Risk factor analysis showed that disc degeneration of the cephalad segment and preoperative spinal stenosis of the L5-S1 segment were risk factors. Conclusion : In L5 floating fusion, radiological ASD was more common in the cephalad segment and clinical ASD was more common in the L5-S1 segment. At the L5-S1 segment, the degree of spinal stenosis appears to be the most influential risk factor in ASD incidences, unlike the cephalad segment.

NFlex Dynamic Stabilization System : Two-Year Clinical Outcomes of Multi-Center Study

  • Coe, Jeffrey D.;Kitchel, Scott H.;Meisel, Hans Jorg;Wingo, Charles H.;Lee, Soo-Eon;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.51 no.6
    • /
    • pp.343-349
    • /
    • 2012
  • Objective : Pedicle-based dynamic stabilization systems, in which semi-rigid rods or cords are used to restrict or control spinal segmental motion, aim to reduce or eliminate the drawbacks associated with rigid fusion. In this study, we analyzed the two-year clinical outcomes of patients treated with the NFlex (Synthes Spine, Inc.), a pedicle-based dynamic stabilization system. Methods : Five sites participated in a retrospective study of 72 consecutive patients who underwent NFlex stabilization. Of these 72 patients, 65 were available for 2-year follow-up. Patients were included based on the presence of degenerative disc disease (29 patients), degenerative spondylolisthesis (16 patients), lumbar stenosis (9 patients), adjacent segment degeneration (6 patients), and degenerative lumbar scoliosis (5 patients). The clinical outcome measures at each assessment were Visual Analogue Scale (VAS) to measure back pain, and Oswestry Disability Index (ODI) to measure functional status. Radiographic assessments included evidence of instrumentation failure or screw loosening. Results : Sixty-five patients (26 men and 39 women) with a mean age of 54.5 years were included. Mean follow-up was 25.6 months. The mean VAS score improved from 8.1 preoperatively to 3.8 postoperatively, representing a 53% improvement, and the ODI score from 44.5 to 21.8, representing a 51% improvement. Improvements in pain and disability scores were statistically significant. Three implant-related complications were observed. Conclusion : Posterior pedicle-based dynamic stabilization using the NFlex system seems effective in improving pain and functional scores, with sustained clinical improvement after two years. With appropriate patient selection, it may be considered an effective alternative to rigid fusion.

Activin A/BMP2 Chimera (AB204) Exhibits Better Spinal Bone Fusion Properties than rhBMP2

  • Ryu, Dalsung;Yoon, Byung-Hak;Oh, Chang-Hyun;Kim, Moon-Hang;Kim, Ji-Yong;Yoon, Seung Hwan;Choe, Senyon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Objective : To compare the spinal bone fusion properties of activin A/BMP2 chimera (AB204) with recombinant human bone morphogenetic protein (rhBMP2) using a rat posterolateral spinal fusion model. Methods : The study was designed to compare the effects and property at different dosages of AB204 and rhBMP2 on spinal bone fusion. Sixty-one male Sprague-Dawley rats underwent posterolateral lumbar spinal fusion using one of nine treatments during the study, that is, sham; osteon only; $3.0{\mu}g$, $6.0{\mu}g$, or $10.0{\mu}g$ of rhBMP2 with osteon; and $1.0{\mu}g$, $3.0{\mu}g$, $6.0{\mu}g$, or $10.0{\mu}g$ of AB204 with osteon. The effects and property on spinal bone fusion was calculated at 4 and 8 weeks after treatment using the scores of physical palpation, simple radiograph, micro-computed tomography, and immunohistochemistry. Results : Bone fusion scores were significantly higher for $10.0{\mu}g$ AB204 and $10.0{\mu}g$ rhBMP2 than for osteon only or $1.0{\mu}g$ AB204. AB204 exhibited more prolonged osteoblastic activity than rhBMP2. Bone fusion properties of AB204 were similar with the properties of rhBMP2 at doses of 6.0 and $10.0{\mu}g$, but, the properties of AB204 at doses of $3.0{\mu}g$ exhibited better than the properties of rhBMP2 at doses of $3.0{\mu}g$. Conclusion : AB204 chimeras could to be more potent for treating spinal bone fusion than rhBMP2 substitutes with increased osteoblastic activity for over a longer period.

Direct Lateral Lumbar Interbody Fusion : Clinical and Radiological Outcomes

  • Lee, Young Seok;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.248-254
    • /
    • 2014
  • Objective : According to the recent development of minimally invasive spinal surgery, direct lumbar interbody fusion (DLIF) was introduced as an effective option to treat lumbar degenerative diseases. However, comprehensive results of DLIF have not been reported in Korea yet. The object of this study is to summarize radiological and clinical outcomes of our DLIF experience. Methods : We performed DLIF for 130 patients from May 2011 to June 2013. Among them, 90 patients, who could be followed up for more than 6 months, were analyzed retrospectively. Clinical outcomes were compared using visual analog scale (VAS) score and Oswestry Disability Index (ODI). Bilateral foramen areas, disc height, segmental coronal and sagittal angle, and regional sagittal angle were measured. Additionally, fusion rate was assessed. Results : A total of 90 patients, 116 levels, were underwent DLIF. The VAS and ODI improved statistically significant after surgery. All the approaches for DLIF were done on the left side. The left and right side foramen area changed from $99.5mm^2$ and $102.9mm^2$ to $159.2mm^2$ and $151.2mm^2$ postoperatively (p<0.001). Pre- and postoperative segmental coronal and sagittal angles changed statistically significant from $4.1^{\circ}$ and $9.9^{\circ}$ to $1.1^{\circ}$ and $11.1^{\circ}$. Fusion rates of 6 and 12 months were 60.9% and 87.8%. Complications occurred in 17 patients (18.9%). However, most of the complications were resolved within 2 months. Conclusion : DLIF is not only effective for indirect decompression and deformity correction but also shows satisfactory mechanical stability and fusion rate.

Biomechanical Analysis of Lumbar Interspinous Process Fixators and Design of Miniaturization and Advanced Flexibility (요추부 극돌기간 고정기구의 생체역학적 해석과 소형화 및 유연성 향상 설계)

  • Park, Jung-Hong;Heo, Soon;Lee, Sung-Jae;Son, Kwon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1509-1517
    • /
    • 2006
  • The intervertebral fusion was reported to increase the degeneration of the neighboring region. Recently, a new technique of inserting an interspinous process fixator has been introduced to minimize the degenerative change in the lumbar spine. This study analyzed biomechanical effects of the fixator in the lumbar spine, and designed a new prototype to improve flexibility of the fixator with a reduced size. The evaluation was based on the displacement, stiffness and von-Mises stress obtained from the mechanical test and finite element analysis. A finite element lumbar model of L1 to L5 was constructed. The finite element model was used to analyze intervertebral fusion, insertion of a commercial fixator and a new prototype. The range of motion of intervertebral segments and pressures at vertebral discs were calculated from FEA. The results showed that the stiffness of the prototype was reduced by 32.9% than that of the commercial one.

Perioperative Results and Complications after Posterior Lumbar Interbody Fusion for Spinal Stenosis in Geriatric Patients over than 70 Years Old

  • Choi, Jong Min;Choi, Man Kyu;Kim, Sung Bum
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.6
    • /
    • pp.684-690
    • /
    • 2017
  • Objective : As increasing the size of the geriatric population, the number of elderly patients, who need the surgery for painful degenerative spinal stenosis has been increasing. The geriatric population may be relatively high complications, because of age and age-associated medical conditions. However, there is a lack of studies addressing the perioperative complications and outcomes in elderly patients with posterior lumbar inter body fusion with screw augmentation (PLIF). Methods : We retrospectively reviewed the medical records and radiographic studies of geriatric patients who had spine surgery of PLIF due to spinal stenosis for 11 years. We divided into 2 groups (A; 70-75 years, B; over then 76 years) according to the age. Surgical level of each groups, hospital day and postoperative day, co-morbidities, complications, clinical outcomes were analyzed. Operative reports, hospital and outpatient clinic charts, and radiographic studies were reviewed. Results : Group A was composed of 80 patients, their mean age was 72.21 and female dominant (n=46), and their mean surgically fused level was 1.52 level. Group B was 36 patients, their mean age was 78.83 and female dominant (n=20), and their mean surgically fused level was 1.36 level. Comparing between two groups, complications, postoperative hospital stay were slightly increase in group B and co-morbidity was statistically high in group B, however clinical outcomes were similar between two groups. Conclusion : Increasing age might be an important risk factor for complications in patients undergoing PLIF, however, we would like to recommend that if the situation of spine of extreme geriatric patients need PLIF, it should be in the surgeon's consideration after careful selection and clinical judgement.

The Effect of Postoperative Use of Teriparatide Reducing Screw Loosening in Osteoporotic Patients

  • Kim, Jae Wook;Park, Seung Won;Kim, Young Baeg;Ko, Myeong Jin
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.494-502
    • /
    • 2018
  • Objective : The loosening of pedicle screws (PS) is one of the frequent problems of spinal surgery in the patients with osteoporosis. Previous studies had revealed that intermittent injection of teriparatide could reduce PS loosening by improving bone mass and quality when their patients took parathyroid hormone for a considerable duration before surgery. However, although the teriparatide is usually used after spine surgery in most clinical situations, there was no report on the efficacy of teriparatide treatment started after spine surgery. The purpose of this retrospective study was to examine the efficacy of teriparatide treatment started immediately after lumbar spinal surgery to prevent pedicle screw loosening in patients with osteoporosis. Methods : We included 84 patients with osteoporosis and degenerative lumbar disease who underwent transforaminal interbody fusion and PS fixation and received parathyroid hormone or bisphosphonate (BP) postoperatively. They were divided into teriparatide group (daily injection of $20{\mu}g$ of teriparatide for 6 months, 33 patients, 172 screws) and BP group (weekly oral administration of 35 mg of risedronate, 51 patients, 262 screws). Both groups received calcium (500 mg/day) and cholecalciferol (1000 IU/day) together. The screw loosening was evaluated with simple radiographic exams at 6 and 12 months after the surgery. We counted the number of patients with PS loosening and the number of loosened PS, and compared them between the two groups. Clinical outcomes were evaluated using visual analog scale (VAS) and Oswestry disability index (ODI) preoperatively, and at 12 months after surgery. Results : There was no significant difference in the age, sex, diabetes, smoking, bone mineral density, body mass index, and the number of fusion levels between the two groups. The number of PS loosening within 6 months after surgery did not show a significant difference between the teriparatide group (6.9%, 12/172) and the BP group (6.8%, 18/272). However, during 6-12 months after surgery, it was significantly lower in the teriparatide group (2.3%, 4/172) than the BP group (9.2%, 24/272) (p<0.05). There was no significant difference in the number of patients showing PS loosening between the teriparatide and BP groups. The teriparatide group showed a significantly higher degree of improvement of the bone mineral density (T-score) than that of BP group (p<0.05). There was no significant difference in the pre- and post-operative VAS and ODI between the groups. Conclusion : Our data suggest that the teriparatide treatment starting immediately after lumbar spinal fusion surgery could reduce PS loosening compared to BP.

Factors Affecting Discharge Delay in Lumbar Spinal Surgery Patients Who were Treated according to a Critical Pathway (표준진료지침을 적용한 요추 수술 환자의 퇴원 지연에 영향을 미치는 요인)

  • Kim, Jeoung Hee;Lee, Eun Ha;Kim, Su Ran;Kim, Sung Reul
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.1
    • /
    • pp.43-52
    • /
    • 2016
  • Purpose: The aim of this study was to identify demographic, clinical, physical, and psychosocial factors affecting discharge delay in lumbar spinal surgery patients who were treated according to a critical pathway. Methods: A sample of 170 patients with lumbar spinal surgery agreed to participate in the study, between April 1, 2014 and August 30, 2015. Data were analyzed by mean, standard deviation, t-test, ${\chi}^2$-test, ANCOVA, and logistic regression analysis using SPSS 22.0 program. Results: Approximately fifty-nine percent of the participants was delayed discharge. On logistic regression analysis, female gender (OR=2.63, 95% CI=1.40~4.94), age (OR=1.03, 95% CI=1.01~1.05), spondylolisthesis (OR=4.49, 95% CI=1.90~10.61), and spinal fusion operation (OR=4.14, 95% CI=1.89~9.05) were significant factors predicting discharge delay of the participants. However, discharge delay was not related with pain, physical function, depression, or family support. Conclusion: An analysis of discharge delay may assist in evaluating and revising critical pathway for optimal care. In addition, nurses need to understand the factors affecting discharge delay of the given population who were treated according to a critical pathway.

Clinical Significance of Radiological Stability in Reconstructed Thoracic and Lumbar Spine Following Vertebral Body Resection

  • Sung, Sang-Hyun;Chang, Ung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.4
    • /
    • pp.323-329
    • /
    • 2014
  • Objective : Vertebral body replacement following corpectomy in thoracic or lumbar spine is performed with titanium mesh cage (TMC) containing any grafts. Radiological changes often occur on follow-up. This study investigated the relationship between the radiological stability and clinical symptoms. Methods : The subjects of this study were 28 patients who underwent corpectomy on the thoracic or lumbar spine. Their medical records and radiological data were retrospectively analyzed. There were 23 cases of tumor, 2 cases of trauma, and 3 cases of infection. During operation, spinal reconstruction was done with TMC and additional screw fixation. We measured TMC settlement in sagittal plane and spinal angular change in coronal and sagittal plane at postoperative one month and last follow-up. Pain score was also checked. We investigated the correlation between radiologic change and pain status. Whether factors, such as the kind of graft material, surgical approach, and fusion can affect the radiological stability or not was analyzed as well. Results : Mean follow-up was 23.6 months. During follow-up, $2.08{\pm}1.65^{\circ}$ and $6.96{\pm}2.08^{\circ}$ of angular change was observed in coronal and sagittal plane, respectively. A mean of cage settlement was $4.02{\pm}2.83mm$. Pain aggravation was observed in 4 cases. However, no significant relationship was found between spinal angular change and pain status (p=0.518, 0.458). Cage settlement was seen not to be related with pain status, either (p=0.644). No factors were found to affect the radiological stability. Conclusion : TMC settlement and spinal angular change were often observed in reconstructed spine. However, these changes did not always cause postoperative axial pain.

Change in Kinematics of the Spine after Insertion of an Interspinous Spacer for the Treatment of the Lumbar Spinal Stenosis

  • Lee H. S.;Moon S. J.;Kwon S. Y.;Jung T. G.;Shin K. C.;Lee K. Y.;Lee S. J.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.3
    • /
    • pp.151-155
    • /
    • 2005
  • Interspinous spacers have been developed as an alternative surgical treatment for laminectomy or fusion with pedicle screws and rods for the treatment of lumbar spinal stenosis. However, its biomedical efficacies are well not known. In this study, we evaluated kinematic behaviors of the surgical and the adjacent levels before and after inserting interspinous spacers. Three porcine lumbar spines were prepared. On each specimen, an interspinous spacer was inserted at the L4-L5. Flexion-extension moments (0, 2.5, 5.0, 7.5, 10Nm) were applied. A stereophotogrammetric set-up with DLT algorithm was used to assess the three-dimensional motions of the specimen where three markers $({\square}0.8mm)$ were attached to each vertebra. Results showed that extension motion decreased by $15-24\%$ at the surgical level (L4-L5) after insertion of interspinous spacer. At the adjacent levels, the range of motion remained unchanged. In flexion, no significant changes in motion were observed regardless of levels. Therefore, our experimental results demonstrated the interspinous spacer is very effective in limiting the extension motion that may cause narrowing of the spinal canal and vertebral foramen while maintaining kinematic behaviors at the adjacent levels. Further, these results suggested that the use of interspinous spacer may be able to prevent lower back pain at the surgical level and to lower the incidence of degenerative changes at the adjacent levels.