• 제목/요약/키워드: lumbar spinal fusion

검색결과 135건 처리시간 0.027초

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권5호
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.

척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가 (Biomechanical Evaluation of SMA Dynamic Stabilization for Spinal fusion)

  • 김윤혁;박원만;김경수;박형균;주증우;박경우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.517-518
    • /
    • 2006
  • In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, low FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.

  • PDF

Diagnostic Value of Early Inflammatory Reaction in Postoperative Infection of the Lumbar Spine

  • Mun, Ji-Hun;Kim, Dong-Hyun;Ryu, Kyeong-Sik;Park, Chun-Kun;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제38권3호
    • /
    • pp.206-210
    • /
    • 2005
  • Objective : Our aim is to evaluate the early changes of biologic markers such as white blood cell[WBC] count, erythrocyte sedimentation rate[ESR] and C-reactive protein[CRP] in early diagnosis of postoperative infection and to differentiate infection from inflammatory reaction in lumbar spine surgery. Methods : We reviewed 330patients who had undergone spinal operations between May 1999 and October 2001. For this study, the patients were classified into two groups, which include a group that underwent spinal decompressive surgery without instrumentation[SD], and the other group that underwent fusion surgery with spinal instrumentation[SI]. And each group was also subdivided into two groups respectively, one with infection and the other without infection. We retrospectively analyzed the WBC count, ESR and CRP preoperatively and postoperatively, according to their operation type and postoperative infection history. Results : Inflammatory indices were physiologically affected by instrumentation itself. But ESR and CRP elevations were more prolonged and sustained under infection. In SD patients without infection, ESR and CRP were stabilized 5 days after surgery. In SI patients without infection, CRP was stabilized about 7days after surgery, but ESR showed sustained and variously elevated. In both SD and SI groups, the stabilization of CRP was the most reliable behavior of surgery without infection. Conclusion : C-reactive protein is most sensitive parameter for postoperative spine infection. The knowledge of the inflammatory indices and their relatively uniform patterns with or without infection offers surgeons the ability to infer the state of surgical wound.

후방경유 요추 융합수술시 척추후관절낭 손상의 운동역학적 영향 (Biomechanical Effects of Facet Capsule Injuries in Posterior Lumbar Fusion Operations)

  • 박승원;김영백;황성남;최덕영;권정택;민병국;석종식
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권3호
    • /
    • pp.358-365
    • /
    • 2001
  • Objectives : Although posterior lumbar fusion operations had been reported to accelerate spinal degeneration, there have been only a few studies for their biomechanical effects. We have studied the change of motion range at the vertebral joint one level above the fusion(UVJ) in pedicle screw fixation group(PSF)(n=13) where facet capsule was destroyed and in posterior lumbar interbody fusion group(PLIF)(n=8) where it was spared. Patients and Methods : The patients were divided into early(3 to 6 months) and late(over 12 months) according to postoperative follow-up period. The flexion, extension and flexion-extension angles(FA, EA, FEA) were measured at the UVJ with pre-operative, early and late post-operative films. Results : Mean age and male to female ratio were $52.7{\pm}9.3$ and 1 : 3.2. Mean follow-up periods were $144.1{\pm}30.0$ and $528.8{\pm}160.3$ days in early and late groups, respectively. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than pre-operative angles($7.8{\pm}3.9$, $5.1{\pm}3.7$)(p<0.01, p<0.05). All angles in the PLIF showed no significant changes with time. The FEA and FA in the late PSF($11.8{\pm}3.1$, $8.5{\pm}2.9$) were significantly greater than those of the late PLIF($7.6{\pm}2.3$, $3.4{\pm}2.0$)(p<0.01, p<0.001). All angles at early follow-up period were similar between PSF and PLIF. The EA showed no significant change in relation with follow-up period or fusion method. Conclusion : As a result, the facet capsule injury in pedicle screw fixation seems to be related with increased flexion angle or degeneration of the adjacent joint above the fused vertebra in the late phase.

  • PDF

The Effects of Spinopelvic Parameters and Paraspinal Muscle Degeneration on S1 Screw Loosening

  • Kim, Jin-Bum;Park, Seung-Won;Lee, Young-Seok;Nam, Taek-Kyun;Park, Yong-Sook;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권4호
    • /
    • pp.357-362
    • /
    • 2015
  • Objective : To investigate risk factors for S1 screw loosening after lumbosacral fusion, including spinopelvic parameters and paraspinal muscles. Methods : We studied with 156 patients with degenerative lumbar disease who underwent lumbosacral interbody fusion and pedicle screw fixation including the level of L5-S1 between 2005 and 2012. The patients were divided into loosening and non-loosening groups. Screw loosening was defined as a halo sign larger than 1 mm around a screw. We checked cross sectional area of paraspinal muscles, mean signal intensity of the muscles on T2 weight MRI as a degree of fatty degeneration, spinopelvic parameters, bone mineral density, number of fusion level, and the characteristic of S1 screw. Results : Twenty seven patients showed S1 screw loosening, which is 24.4% of total. The mean duration for S1 screw loosening was $7.3{\pm}4.1$ months after surgery. Statistically significant risk factors were increased age, poor BMD, 3 or more fusion levels (p<0.05). Among spinopelvic parameters, a high pelvic incidence (p<0.01), a greater difference between pelvic incidence and lumbar lordotic angle preoperatively (p<0.01) and postoperatively (p<0.05). Smaller cross-sectional area and high T2 signal intensity in both multifidus and erector spinae muscles were also significant muscular risk factors (p<0.05). Small converging angle (p<0.001) and short intraosseous length (p<0.05) of S1 screw were significant screw related risk factors (p<0.05). Conclusion : In addition to well known risk factors, spinopelvic parameters and the degeneration of paraspinal muscles also showed significant effects on the S1 screw loosening.

The Effect of Body Mass Index on Intra-Abdominal Pressure and Blood Loss in Lumbar Spine Surgery

  • Han, In-Ho;Son, Dong-Wuk;Nam, Kyoung-Hyup;Choi, Byung-Kwan;Song, Geun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권2호
    • /
    • pp.81-85
    • /
    • 2012
  • Objective : The purpose of this prospective study was to evaluate the effects of body mass index (BMI) on intra-abdominal pressure (IAP) and intraoperative blood loss (IBL) during lumbar spinal surgery. Methods : Thirty patients scheduled for single level posterior lumbar interbody fusion were allocated equally to a normal group (Group 1, BMI;$18.5-22.9kg/m^2$), an overweight group (Group 2, BMI; $23-24.9kg/m^2$), and an obese group (Group 3, BMI; $25.0-29.9kg/m^2$) according to BMI. IAP was measured using a urinary bladder catheter; 1) supine after anesthesia induction, 2) prone at skin incision, 3) prone at the end of surgery. In addition, IBL was also measured in the three groups. Results : IAP in the supine position was not significantly different in groups 1, 2, and 3 (2.7 mm Hg, 3.0 mm Hg, and 4.2 mm Hg, respectively) ($p$=0.258), and IAP in the prone position at incision increased to 7.8 mm Hg, 8.2 mm Hg, and 10.4 mm Hg, respectively, in the three groups, and these intergroup differences were significant, especially for Group 3 ($p$=0.000). IAP at the end of surgery was slightly lower (7.0 mm Hg, 7.7 mm Hg, and 9.2 mm Hg, respectively). IBLs were not significantly different between the three groups. However, IBLs were found to increase with IAP in the prone position ($p$=0.022) and BMI ($p$<0.05). Conclusion : These results show that BMI affects IAP in the prone position more than in the supine position during lumbar spinal surgery. In addition, IBLs were found to increase with IAP in the prone position and with BMI. Thus, IBLs can be expected to be higher in morbidly obese patients due to an increased IAP.

The Change of Adjacent Segment and Sagittal Balance after Thoracolumbar Spine Surgery

  • Kim, Kang-San;Hwang, Hyung-Sik;Jeong, Je-Hoon;Moon, Seung-Myung;Choi, Sun-Kil;Kim, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권5호
    • /
    • pp.437-442
    • /
    • 2009
  • Objective : To characterize perioperative biomechanical changes after thoracic spine surgery. Methods : Fifty-eight patients underwent spinal instrumented fusions and simple laminectomies on the thoracolumbar spine from April 2003 to October 2008. Patients were allocated to three groups; namely, the laminectomy without fusion group (group I, n = 17), the thoracolumbar fusion group (group II, n = 27), and the thoracic spine fusion group (group III, n = 14). Sagittal (ADS) and coronal (ADC) angles for adjacent segments were measured from two disc spaces above lesions at the upper margins, to two disc spaces below lesions at the lower margins. Sagittal (TLS) and coronal (TLC) angles of the thoracolumbar junction were measured from the lower margin of the 11th thoracic vertebra body to the upper margin of the 2nd lumbar vertebra body on plane radiographs. Adjacent segment disc heights and disc signal changes were determined using simple spinal examinations and by magnetic resonance imaging. Clinical outcome indices were determined using a visual analog scale. Results : The three groups demonstrated statistically significant differences in terms of angle changes by ANOVA (p<0.05). All angles in group I showed significantly smaller angles changes than in groups II and III by Turkey's multiple comparison analysis. Coronal Cobb's angles of the thoracolumbar spine (TLC) were not significantly different in the three groups. Conclusion : Postoperative sagittal balance is expected to change in the adjacent and thoracolumbar areas after thoracic spine fusion. However, its prevalence seems to be higher when the thoracolumbar spine is included in instrumented fusion.

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • 제7권3호
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.

Polymethylmethacrylate-Augmented Screw Fixation for Stabilization of the Osteoporotic Spine : A Three-Year Follow-Up of 37 Patients

  • Moon, Bong-Ju;Cho, Bo-Young;Choi, Eun-Young;Zhang, Ho-Yeol
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권4호
    • /
    • pp.305-311
    • /
    • 2009
  • Objective : The purpose of this study was to determine the efficacy, radiological findings, clinical outcomes and complications in patients with lumbar stenosis and osteoporosis after the use of polymethylmethacrylate (PMMA) augmentation of a cannulated pedicle screw. Methods : Thirty-seven patients with degenerative spinal stenosis and osteoporosis (T-score < -2.5) underwent lumbar fusion using the Dream Technology Pedicle Screw ($DTPS^{TM}$, Dream Spine Total Solutions, Dream STS, Seoul. Korea) between 2005 and 2007. The clinical outcomes were evaluated by using the visual analog scale (VAS) and the Prolo scale. Radiologic findings were documented through computed tomography (CT) and plain films. Results : Thirty-seven patients were evaluated and included, 2 males and 35 females with an average bone mineral density (BMD) of $0.47g/cm^2$. The average age of the patients was 68.7 (range, 57-88). The preoperative VAS for low back and leg pain ($7.87{\pm}0.95$ and $8.82{\pm}0.83$) were higher as compared with postoperative VAS ($2.30{\pm}1.61$ and $1.42{\pm}0.73$) with statistical significance (p = 0.006, p = 0.003). According to the Prolo scale, 11, 22, one and three patients were in excellent, good, fair and poor conditions, respectively. The average amount of the injected cement per one cannulated screw was $1.83{\pm}0.11\;mL$. Conclusion : The results show favorable outcome both clinically and radiographically for 37 patients who underwent lumbar fusion using $DTPS^{TM}$ and PMMA. Based on the results, the use of this surgical method can be a safe and effective option for the operation on the osteoporotic spine.

Trends and Costs of External Electrical Bone Stimulators and Grafting Materials in Anterior Lumbar Interbody Fusion

  • D'Oro, Anthony;Buser, Zorica;Brodke, Darrel Scott;Park, Jong-Beom;Yoon, Sangwook Tim;Youssef, Jim Aimen;Meisel, Hans-Joerg;Radcliff, Kristen Emmanuel;Hsieh, Patrick;Wang, Jeffrey Chun
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.973-980
    • /
    • 2018
  • Study Design: Retrospective review. Purpose: To identify the trends in stimulator use, pair those trends with various grafting materials, and determine the influence of stimulators on the risk of revision surgery. Overview of Literature: A large number of studies has reported beneficial effects of electromagnetic energy in healing long bone fractures. However, there are few clinical studies regarding the use of electrical stimulators in spinal fusion. Methods: We used insurance billing codes to identify patients with lumbar disc degeneration who underwent anterior lumbar interbody fusion (ALIF). Comparisons between patients who did and did not receive electrical stimulators following surgery were performed using logistic regression analysis, chi-square test, and odds ratio (OR) analysis. Results: Approximately 19% of the patients (495/2,613) received external stimulators following ALIF surgery. There was a slight increase in stimulator use from 2008 to 2014 (multi-level $R^2=0.08$, single-level $R^2=0.05$). Patients who underwent multi-level procedures were more likely to receive stimulators than patients who underwent single-level procedures (p<0.05; OR, 3.72; 95% confidence interval, 3.02-4.57). Grafting options associated with most frequent stimulator use were bone marrow aspirates (BMA) plus autograft or allograft for single-level and allograft alone for multi-level procedures. In both cohorts, patients treated with bone morphogenetic proteins were least likely to receive electrical stimulators (p<0.05). Patients who received stimulation generally had higher reimbursements. Concurrent posterior lumbar fusion (PLF) (ALIF+PLF) increased the likelihood of receiving stimulators (p<0.05). Patients who received electrical stimulators had similar revision rates as those who did not receive stimulation (p>0.05), except those in the multilevel ALIF+PLF cohort, wherein the patients who underwent stimulation had higher rates of revision surgery. Conclusions: Concurrent PLF or multi-level procedures increased patients' likelihood of receiving stimulators, however, the presence of comorbidities did not. Patients who received BMA plus autograft or allograft were more likely to receive stimulation. Patients with and without bone stimulators had similar rates of revision surgery.